66 resultados para broadband pulsed beam
Resumo:
A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Background: The presence of coronary artery calcium (CAC) is an independent marker of increased risk of cardiovascular disease (CVD) events and mortality. However, the predictive value of thoracic aorta calcification (TAC), which can be additionally identified without further scanning during assessment of CAC, is unknown. Methods: We followed a cohort of 8401 asymptomatic individuals (mean age: 53 +/- 10 years, 69% men) undergoing cardiac risk factor evaluation and TAC and CAC testing with electron beam computed tomography. Multivariable Cox proportional hazards models were developed to predict all-cause mortality based on the presence of TAC. Results: During a median follow-up period of 5 years, 124 (1.5%) deaths were observed. Overall survival was 96.9% and 98.9% for those with and without detectable TAC, respectively (p < 0.0001). Compared to those with no TAC, the hazard ratio for mortality in the presence of TAC was 3.25 (95% CI: 2.28-4.65, p < 0.0001) in unadjusted analysis. After adjusting for age, gender, hypertension, dyslipidemia, diabetes mellitus, smoking and family history of premature coronary artery disease, and presence of CAC the relationship remained robust (HR 1.61, 95% CI: 1.10-2.27, p = 0.015). Likelihood ratio chi(2) statistics demonstrated that the addition of TAC contributed significantly in predicting mortality to traditional risk factors alone (chi(2) = 13.62, p = 0.002) as well as risk factors + CAC (chi(2) = 5.84, p = 0.02) models. Conclusion: In conclusion, the presence of TAC was associated with all-cause mortality in our study; this relationship was independent of conventional CVD risk factors as well as the presence of CAC. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background and purpose: To evaluate biochemical control and treatment related toxicity of patients with localized adenocarcinoma of the prostate treated with high dose-rate brachytherapy (HDRB) combined with conventional 2D or 3D-conformal external beam irradiation (EBI). Material and methods: Four-hundred and three patients treated between December 2000 and March 2004. HDRB was delivered with three fractions of 5.5-7 Gy with a single implant, followed by 45 Gy delivered with 2D or 3D conformal EBI. Results: The median follow-up was 48.4 months. Biochemical failure (BF) occurred in 9.6% according to both ASTRO and Phoenix consensus criteria. Mean time to relapse was 13 and 26 months, respectively. The 5-year BF free survival using the ASTRO criteria was 94.3%, 86.9% and 86.6% for the low, intermediate and high risk groups, respectively; using Phoenix criteria, 92.4%, 88.0% and 85.3%, respectively. The only predictive factor of BF in the multivariate analysis by both ASTRO and Phoenix criteria was the presence of prostate nodules detected by digital palpation, and patients younger than 60 years presented a higher chance of failure using Phoenix criteria only. Conclusions: Treatment scheme is feasible and safe with good efficacy. (C) 2011 Elsevier Ireland Ltd All rights reserved. Radiotherapy and Oncology 98 (2011) 169-174
Resumo:
To determine reference values for tissue Doppler imaging (TDI) and pulsed Doppler echocardiography for left ventricular diastolic function analysis in a healthy Brazilian adult population. Observations were based on a randomly selected healthy population from the city of Vitoria, Espirito Santo, Brazil. Healthy volunteers (n = 275, 61.7% women) without prior histories of cardiovascular disease underwent transthoracic echocardiography. We analyzed 175 individuals by TDI and evaluated mitral annulus E`- and A`-waves from the septum (S) and lateral wall (L) to calculate E`/A` ratios. Using pulsed Doppler echocardiography, we further analyzed the mitral E- and A-waves, E/A ratios, isovolumetric relaxation times (IRTs), and deceleration times (DTs) of 275 individuals. Pulsed Doppler mitral inflow mean values for men were as follows: E-wave: 71 +/- 16 cm/sec, A-wave: 68 +/- 15 cm/sec, IRT: 74.8 +/- 9.2 ms, DT: 206 +/- 32.3 ms, E/A ratio: 1.1 +/- 0.3. Pulsed Doppler mitral inflow mean values for women were as follows: E-wave: 76 +/- 17, A-wave: 69 +/- 14 cm/sec, IRT: 71.2 +/- 10.5 ms, DT: 197 +/- 33.3 ms, E/A ratio: 1.1 +/- 0.3. IRT and DT values were higher in men than in women (P = 0.04 and P = 0.007, respectively). TDI values in men were as follows: E`S: 11 +/- 3 cm/sec, A`S: 13 +/- 2 cm/sec, E`S/A`S: 0.89 +/- 0.2, E`L: 14 +/- 3 cm/sec, A`L: 14 +/- 2 cm/sec, E`L/A`L: 1.1 +/- 0.4. E-wave/ E`S ratio: 6.9 +/- 2.2; E-wave / E`L ratio: 4.9 +/- 1.7. In this study, we determined pulsed Doppler and TDI derived parameters for left ventricular diastolic function in a large sample of healthy Brazilian adults. (Echocardiography 2010;27:777-782).
Resumo:
OBJECTIVES To describe the use of pulsed fluoroscopic guidance, to perform endoscopic procedures in pregnant women, by inverting the fluoroscope`s c-arm using a lead thyroid collar to shield the fetus from the direct X-ray beam. The use of radiation during treatment of pregnant patients with urolithiasis remains a recurring dilemma. METHODS Between May 2006 and December 2008, endoscopic treatment due to ureteral stones was attempted in 8 pregnant women. In all cases, we use an inverted fluoroscope`s c-arm during endoscopic treatment associated with 2 lead neck thyroid collars to shield the uterus, protecting the fetus from direct radiation. Indication for treatment was symptomatic ureteral stones unresponsive to medical treatment in 7 and persistent fever in 1. RESULTS Mean ureteral stone size was 8.1 +/- 4.8 mm, located in the left ureter in 5 (62.5%) cases. Three (37.5%) patients had stone located in the upper ureter, 2 (25%) in the middle ureter, and 3 (37.5) in the distal ureter. In 6 cases, ureteral stones were treated using the semi-rigid ureteroscope, whereas in 1 case a flexible ureteroscope was needed. One woman was treated with insertion of a double-J stent due to associated urinary infection. No women has early delivery related to the endoscopic procedure, and all neonates were perfectly normal. CONCLUSIONS We present a technique for endoscopic procedures in pregnant women inverting the fluoroscope`s c-arm and protecting the fetus from the direct X-ray beam. This practical approach should be specially considered when no portable ultrasound and radiologic assistance in available in the operating room. UROLOGY 75: 1505-1508, 2010. (c) 2010 Published by Elsevier Inc.
Resumo:
STUDY DESIGN: Controlled laboratory study. OBJECTIVE: To evaluate the effect of low-intensity therapeutic ultrasound on the murine calcaneus tendon healing process. BACKGROUND: Therapeutic ultrasound promotes formation and maturation of scar tissue. METHODS: Calcaneus tendon tenotomy and tenorrhaphy was performed on 28 Wistar rats. After the procedure, the animals were randomly divided into 2 groups. The animals in the experimental group received a 5-minute ultrasound application, once a day, at a frequency of 1 MHz, a spatial average temporal average intensity of 0.1 W/cm(2), and a spatial average intensity of 0.52 W/cm(2) at a 16-Hz frequency pulse mode (duty cycle, 20%). Data for the injured side were normalized in relation to the data from the contralateral healthy calcaneus tendon (relative values). The animals in the control group received sham treatment. After a 28-day treatment period, the animals were sacrificed and their tendons surgically removed and subjected to mechanical stress testing. The parameters analyzed were cross-sectional area (mm(2)), ultimate load (N), tensile strength (MPa), and energy absorption (mJ). RESULTS: A significant difference between groups was found for the relative values of ultimate load and tensile strength. The mean +/- SD ultimate load of the control group was -3.5% +/- 32.2% compared to 33.3% +/- 26.8% for the experimental group (P = .005). The mean tensile strength of the control group was -47.7% +/- 19.5% compared to -28.1% +/- 24.1% for the experimental group (P = .019). No significant difference was found in cross-sectional area and energy absorption. CONCLUSION: Low-intensity pulsed ultrasound produced by a conventional therapeutic ultrasound unit can positively influence the calcaneus tendon healing process in rats. J Ort hop Sports Phys Ther 2011;41(7):526-531, Epub 2 February 2011. doi:10.2519/jospt.2011.3468
Resumo:
Ultrasonometry seems to have a future for the evaluation of fracture healing. Ultrasound propagation velocity (USPV) significantly decreases at the same time that bone diameter decreases as healing takes place, thus approaching normal values. In this investigation, both USPV and broadband ultrasound attenuation (BUA) were measured using a model of a transverse mid-diaphyseal osteotomy of sheep tibiae. Twenty-one sheep were operated and divided into three groups of seven, according to the follow-up period of 30, 60, and 90 days, respectively. The progress of healing of the osteotomy was checked with monthly conventional radiographs. The animals were killed at the end of the period of observation of each group, both operated-upon and intact tibiae being resected and submitted to the measurement of underwater transverse and direct contact transverse and longitudinal USPV and BUA at the osteotomy site. The intact left tibia of the 21 animals was used for control, being examined on a symmetrical diaphyseal segment. USPV increased while BUA decreased with the progression of healing, with significant differences between the operated and untouched tibiae and between the periods of observation, for most of the comparisons. There was a strong negative correlation between USPV and BUA. Both USPV and BUA directly reflect and can help predict the healing of fractures, but USPV alone can be used as a fundamental parameter. Ultrasonometry may be of use in clinical application to humans provided adequate adaptations can be developed. (C) 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:444-451, 2011
Resumo:
Studies have shown that autologous hematopoietic SCT (HSCT) can be used as an intensive immunosuppressive therapy to treat refractory patients and to prevent the progression of multiple sclerosis (MS). This is a prospective multicentric Brazilian MS trial comparing two conditioning regimens: BEAM/horse ATG and CY/rabbit ATG. Most (80.4%) of the 41 subjects in the study had the secondary progressive MS subtype and the mean age was 42 years. The baseline EDSS score in 58.5% of the subjects was 6.5 and 78% had a score of 6.0 or higher, respectively. The complication rate during the intra-transplantation period was 56% for all patients: 71.4% of the patients in the BEAM/hATG group and 40% in the CY/rATG group (P = 0.04). Three subjects (7.5%) died of cardiac toxicity, sepsis and alveolar hemorrhage, all of them in the BEAM/ATG group. EFS was 58.54% for a ll patients: 47% in the BEAM/hATG group and 70% in the CY/rATG group (P = 0.288). In conclusion, the CY/rATG regimen seems to be associated with similar outcome results, but presented less toxicity when compared with the BEAM/hATG regimen. Long-term follow-up would be required to fully assess the differences in therapeutic effectiveness between the two regimens. Bone Marrow Transplantation (2010) 45, 239-248; doi:10.1038/bmt.2009.127; published online 6 July 2009
Resumo:
The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatment verification method and its applicability as a part of a quality assurance program in radiotherapy. (c) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Introduction: The aim of the present study was to test the accuracy of small-volume cone-beam computed tomography (CBCT) scanning in the detection of horizontal root fractures and to assess the influence of a metallic post. Methods: Forty teeth were divided into four groups based on the presence of metallic posts and horizontal root fracture. The teeth were examined by small-volume CBCT scanning at 0.2-mm voxel resolution. Three observers analyzed the samples for the presence of a horizontal root fracture. Sensitivity and specificity were calculated. Results: High values for accuracy (73%-88%) were obtained in the groups without a metallic post, and statistically significant differences were found when the group with a metallic post has been observed (55%-70%). Intraobserver agreement also showed statistically significant differences in the groups with a metallic post. Conclusions: Small-volume CBCT scanning showed high accuracy in detecting horizontal root fracture without a metallic post. However, the presence of a metallic post significantly reduced the specificity and sensitivity of this examination. (J Endod 2011;37:1456-1459)
Resumo:
The calcifying cystic odontogenic tumour (CCOT) is a rare benign cystic neoplasm not infrequently associated with odontoma. This report documents a case of CCOT associated with compound odontoma arising in the anterior maxilla in a 25-year-old woman. Conventional radiographs showed a large calcified mass with poorly visualized radiolucent margins. The extent and condition of the internal structure of the CCOT associated with odontoma was able to be determined based on radiographic findings from cone beam computed tomography. This advanced image technique proved to be extremely useful in the radiographic assessment of this particular neoplasm of the jawbones.
Resumo:
The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p > 0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p > 0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.
Resumo:
Objective. The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. Study design. The study population consisted of 15 dry human skulls that were submitted to CBCT, and 3-dimensional (3D) images were generated. Linear and angular measurements based on conventional craniometric anatomical landmarks, and were identified in 3D-CBCT images by 2 radiologists twice each independently. Subsequently, physical measurements were made by a third examiner using a digital caliper and a digital goniometer. Results. The results demonstrated no statistically significant difference between inter-and intra-examiner analysis. Regarding accuracy test, no statistically significant differences were found of the comparison between the physical and CBCT-based linear and angular measurements for both examiners (P = .968 and .915, P = .844 and .700, respectively). Conclusions. 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 430-436)
Resumo:
The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 249-257)
Resumo:
Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865