44 resultados para Variable sample size X- control chart
Resumo:
Objective: To evaluate the determinants of total plasma homocysteine levels and their relations with nutritional parameters, inflammatory status, and traditional risk factors for cardiovascular disease in renal failure patients on dialysis treatment. Design: The study was conducted on 70 clinically stable patients, 50 of them on hemodialysis (70% men; 55.3 +/- 14.5 years) and 20 on peritoneal dialysis (50% men; 62 +/- 13.7 years). Patients were analyzed in terms of biochemical parameters (serum lipids, creatinine, homocysteine [Hcy], creatine-kinase [Ck], folic acid, and vitamin B(12)), anthropometric data, markers of inflammatory status (tumor necrosis factor-alpha, C-reactive protein, interleukin-6), and adapted subjective global assessment. Results: The total prevalence of hyperhomocysteinemia (>15 mu mol/L) was 85.7%. Plasma folic acid and plasma vitamin B(12) were within the normal range. Multiple regression analysis (r(2) - 0.20) revealed that the determinants of total Hcy were type of dialysis, creatinine, Ck, folic acid, and total cholesterol. Hcy was positively correlated with albumin and creatinine and negatively correlated with total cholesterol, high density lipoprotein cholesterol, folic acid, and vitamin B(12). Conclusions: The determinants of total Hcy in the study sample were type of dialysis, creatinine, Ck, folic acid, and total cholesterol. Evidently, the small sample size might have had an effect on the statistical analyses and further studies are needed. However, Hcy in patients on dialysis treatment may not have the same effect as observed in the general population. In this respect, the association between malnutrition and inflammation may be a confounding factor in the determination of the true relationship between Hcy, nutritional status, and cardiovascular risk factors in this group. (C) 2011 by the National Kidney Foundation, Inc. All rights reserved.
Resumo:
Aims: To estimate the prevalence of symptoms of temporomandibular disorders (TMD) as a function of age and gender, in a representative urban sample from the Brazilian population. Methods: A total of 1,230 inhabitants (51.5% women) aged 15 to 65 years were interviewed by a validated phone survey. Sample size had been previously calculated. TMD symptoms were assessed through five questions, as recommended by the American Academy of Orofacial Pain, in an attempt to identify possible TMD. Data were derived by age and gender. Prevalence of each TMD symptom, and of combination of symptoms, was calculated. Results: At least one TMD symptom was reported by 39.2% of the individuals. Pain related to TMD was noted by 25.6% of the population. Temporomandibular joint (TMJ) sound was the most common symptom of TMD, followed by TMJ pain and masticatory muscle pain. All symptoms were more prevalent in women than in men. With men used as the reference, a relative risk (RR) of at least one TMD symptom in women was 1.31 (95% confidence interval [CI] = 1.14 to 1.52). When at least two symptoms were present, the RR was 1.93 (95% CI = 1.49 to 2.51). For three or more TMD symptoms, the RR was 2.49 (95% CI = 1.67 to 3.71). Women were also more likely than men to have TMD pain (RR = 1.78; 9% CI = 1.45 to 2.18). Conclusion: Individual symptoms, as well as a combination of TMD symptoms, are prevalent in the Brazilian urban population and are more frequent in women than in men. Additional studies should focus on risk factors for and relevance of TMD for the sufferers. J OROFAC PAIN 2010;24:270-278
Resumo:
PURPOSE. To assess the safety of transcorneal electrical stimulation (TES) and explore its efficacy in various subjective and objective parameters of visual function in patients with retinitis pigmentosa (RP). METHODS. Twenty-four patients in this prospective, randomized, partially blinded, good-clinical-practice study underwent TES (5-ms biphasic pulses; 20 Hz; DTL electrodes) 30 minutes per week for 6 consecutive weeks. The patients were randomly assigned to one of three groups: sham, 66%, or 150% of individual electrical phosphene threshold (EPT). Visual acuity (VA), visual field (VF; kinetic, static), electroretinography (Ganzfeld, multifocal), dark-adaptation (DA), color discrimination, and EPTs were assessed at all visits or four times, according to the study plan. RESULTS. TES using DTL electrodes was tolerated well; all patients finished the study. Two adverse (foreign body sensation), but no serious adverse events were encountered. There was a tendency for most functional parameters to improve (8/18) or to remain constant (8/18) in the 150% group. VF area and scotopic b-wave amplitude reached statistical significance (P < 0.027 and P < 0.001, respectively). Only desaturated color discrimination and VF mean sensitivity decreased. There was no obvious trend in the 66% group. CONCLUSIONS. TES was found to be safe in RP patients. Positive trends were discovered, but due to the small sample size of this exploratory study, statistical significance was reached only for VF area and scotopic b-wave amplitude. Further studies with larger sample sizes and longer duration are needed to confirm the findings and to define optimal stimulation parameters. (ClinicalTrials.gov number, NCT00804102.) (Invest Ophthalmol Vis Sci. 2011;52:4485-4496) DOI:10.1167/iovs.10-6932
Resumo:
Current visceral leishmaniasis (VL) control programs in Brazil include the infected dog elimination but, despite this strategy, the incidence of human VL is still increasing. One of the reasons is the long delay between sample collection, analysis, control implementation and the low sensitivity of diagnostic tests. Due to the high prevalence of asymptomatic dogs, the diagnosis of these animals is important considering their vector infection capacity. Hence, a rapid and accurate diagnosis of canine visceral leishmaniasis is essential for an efficient surveillance program. In this study we evaluated the performance of rK39 antigen in an immunochromatographic format to detect symptomatic and asymptomatic Leishmania chagasi infection in dogs and compared the results with those using a crude antigen ELISA. The sensitivity of rK39 dipstick and ELISA were 83% vs. 95%, respectively, while the specificity was both 100%. Our results also demonstrated that the dipstick test was able to detect infected dogs presenting different clinical forms. (C) 2008 Elsevier B.V. All rights reserved.
Evaluation of pH and Calcium Ion Release of Calcium Hydroxide Pastes Containing Different Substances
Resumo:
Introduction: The objective of this study was to evaluate the pH and calcium ion release of calcium hydroxide pastes associated with different substances. Methods: Forty acrylic teeth with simulated root canals were divided into 4 groups according to the substance associated to the calcium hydroxide paste: chlorhexidine (CHX) in 2 formulations (1% solution and 2% gel), Casearia sylvestris Sw extract, and propylene glycol (control). The teeth with pastes and sealed coronal accesses were immersed in 10 mL deionized water. After 10 minutes, 24 hours, 48 hours, and 7, 15, and 30 days, the teeth were removed to another container, and the liquid was analyzed. Calcium ion release was measured by atomic absorption spectrophotometry, and pH readings were made with a pH meter. Data were analyzed statistically by analysis of variance and Tukey test (alpha = 0.05). Results: Calcium analysis revealed significant differences (P < .05) for 1% CHX solution and 2% CHX gel at 10 minutes. After 24 hours, 2% CHX gel x Control and 2% CHX gel x 1% CHX solution differed significantly (P < .05). After 48 hours, there were significant differences (P < .05) for 2% CHX gel x Control and Extract x Control. No differences (P > .05) were observed among groups in the other periods. Regarding the pH, there were significant differences (P < .05) for 2% CHX gel x Control and 2% CHX gel x 1% CHX solution after 48 hours and for 2% CHX gel x Control after 15 days. In the other periods, no differences (P > .05) were observed among groups. Conclusions: All pastes behaved similarly in terms of pH and calcium ion release in the studied periods. (J Endod 2009;35:1274-1277)
Resumo:
Project: Serum samples may not be appropriate to assess lead (Pb) concentrations because they may contain artificially higher Pb concentrations compared with those measured in plasma samples. Here, we compared Pb concentrations in serum versus heparin plasma separated from blood collected with or without vacuum. We have also examined the effects of sample standing time on Pb concentrations measured in serum, heparin plasma, and EDTA plasma. Procedure: We studied plasma and serum samples from twelve healthy subjects. Blood samples were collected via venous drainage phlebotomy with and without vacuum into trace metal free tubes containing no anticoagulants (serum), or lithium heparin, or EDTA (to obtain plasma). Variable sample standing times (0, 5, and 30 min) prior to centrifugation were allowed. Plasma and serum Pb and iron concentrations were determined by inductively coupled plasma mass spectrometry. Plasma and serum cell-free hemoglobin concentrations were measured. Results: Pb concentrations in serum and in heparin plasma from blood samples collected with or without vacuum were similar and not associated with significant changes in iron or hemoglobin concentrations. The sample standing time (up to 30 min) did not affect Pb concentrations in serum or in heparin plasma, which were approximately 50% lower than those found in EDTA plasma. Conclusions: Serum or heparin plasma separated from blood samples collected via venous phlebotomy with or without vacuum are appropriate medium to assess Pb concentrations, independently of the sample standing time. (C) 2010 Elsevier GmbH. All rights reserved.
Resumo:
Peponapis bees are considered specialized pollinators of Cucurbita flowers, a genus that presents several species of economic value (squashes and pumpkins). Both genera originated in the Americas, and their diversity dispersion center is in Mexico. Ten species of Peponapis and ten species of Cucurbita (only non-domesticated species) were analyzed considering the similarity of their ecological niche characteristics with respect to climatic conditions of their occurrence areas (abiotic variables) and interactions between species (biotic variables). The similarity of climatic conditions (temperature and precipitation) was estimated through cluster analyses. The areas of potential occurrence of the most similar species were obtained through ecological niche modeling and summed with geographic information system tools. Three main clusters were obtained: one with species that shared potential occurrence areas mainly in deserts (P. pruinosa, P. timberlakei, C. digitata, C. palmata, C. foetidissima), another in moist forests (P. limitaris, P. atrata, C. lundelliana, C. o. martinezii) and a third mainly in dry forests (C. a. sororia, C. radicans, C. pedatifolia, P. azteca, P. smithi, P. crassidentata, P. utahensis). Some species with similar ecological niche presented potential shared areas that are also similar to their geographical distribution, like those occurring predominantly on deserts. However, some clustered species presented larger geographical areas, such as P. pruinosa and C. foetidissima suggesting other drivers than climatic conditions to shape their distributions. The domestication of Cucurbita and also the natural history of both genera were considered also as important factors. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In this paper, we proposed a new two-parameter lifetime distribution with increasing failure rate, the complementary exponential geometric distribution, which is complementary to the exponential geometric model proposed by Adamidis and Loukas (1998). The new distribution arises on a latent complementary risks scenario, in which the lifetime associated with a particular risk is not observable; rather, we observe only the maximum lifetime value among all risks. The properties of the proposed distribution are discussed, including a formal proof of its probability density function and explicit algebraic formulas for its reliability and failure rate functions, moments, including the mean and variance, variation coefficient, and modal value. The parameter estimation is based on the usual maximum likelihood approach. We report the results of a misspecification simulation study performed in order to assess the extent of misspecification errors when testing the exponential geometric distribution against our complementary one in the presence of different sample size and censoring percentage. The methodology is illustrated on four real datasets; we also make a comparison between both modeling approaches. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
This paper presents the use of a multiprocessor architecture for the performance improvement of tomographic image reconstruction. Image reconstruction in computed tomography (CT) is an intensive task for single-processor systems. We investigate the filtered image reconstruction suitability based on DSPs organized for parallel processing and its comparison with the Message Passing Interface (MPI) library. The experimental results show that the speedups observed for both platforms were increased in the same direction of the image resolution. In addition, the execution time to communication time ratios (Rt/Rc) as a function of the sample size have shown a narrow variation for the DSP platform in comparison with the MPI platform, which indicates its better performance for parallel image reconstruction.
Resumo:
The class of symmetric linear regression models has the normal linear regression model as a special case and includes several models that assume that the errors follow a symmetric distribution with longer-than-normal tails. An important member of this class is the t linear regression model, which is commonly used as an alternative to the usual normal regression model when the data contain extreme or outlying observations. In this article, we develop second-order asymptotic theory for score tests in this class of models. We obtain Bartlett-corrected score statistics for testing hypotheses on the regression and the dispersion parameters. The corrected statistics have chi-squared distributions with errors of order O(n(-3/2)), n being the sample size. The corrections represent an improvement over the corresponding original Rao`s score statistics, which are chi-squared distributed up to errors of order O(n(-1)). Simulation results show that the corrected score tests perform much better than their uncorrected counterparts in samples of small or moderate size.
Resumo:
The Birnbaum-Saunders regression model is commonly used in reliability studies. We address the issue of performing inference in this class of models when the number of observations is small. Our simulation results suggest that the likelihood ratio test tends to be liberal when the sample size is small. We obtain a correction factor which reduces the size distortion of the test. Also, we consider a parametric bootstrap scheme to obtain improved critical values and improved p-values for the likelihood ratio test. The numerical results show that the modified tests are more reliable in finite samples than the usual likelihood ratio test. We also present an empirical application. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
In this article, we give an asymptotic formula of order n(-1/2), where n is the sample size, for the skewness of the distributions of the maximum likelihood estimates of the parameters in exponencial family nonlinear models. We generalize the result by Cordeiro and Cordeiro ( 2001). The formula is given in matrix notation and is very suitable for computer implementation and to obtain closed form expressions for a great variety of models. Some special cases and two applications are discussed.
Resumo:
Classical hypothesis testing focuses on testing whether treatments have differential effects on outcome. However, sometimes clinicians may be more interested in determining whether treatments are equivalent or whether one has noninferior outcomes. We review the hypotheses for these noninferiority and equivalence research questions, consider power and sample size issues, and discuss how to perform such a test for both binary and survival outcomes. The methods are illustrated on 2 recent studies in hematopoietic cell transplantation.
Resumo:
The family of distributions proposed by Birnbaum and Saunders (1969) can be used to model lifetime data and it is widely applicable to model failure times of fatiguing materials. We give a simple matrix formula of order n(-1/2), where n is the sample size, for the skewness of the distributions of the maximum likelihood estimates of the parameters in Birnbaum-Saunders nonlinear regression models, recently introduced by Lemonte and Cordeiro (2009). The formula is quite suitable for computer implementation, since it involves only simple operations on matrices and vectors, in order to obtain closed-form skewness in a wide range of nonlinear regression models. Empirical and real applications are analyzed and discussed. (C) 2010 Elsevier B.V. All rights reserved.