115 resultados para Sample Preparation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sensitive and reproducible method by microextraction packed sorbent and liquid chromatography with UV detection (MEPS/LC-UV) is described for the determination of new generation antidepressants (sertraline, mirtazapine, fluoxetine, citalopram and paroxetine) in human plasma samples. The MEPS variables, such as sample volume, pH, number of extraction cycles (draw-eject), and desorption conditions (solvent and solvent volume of elution) influenced the MEPS/LC efficiency significantly. Important factors in the optimization of MEPS efficiency, as well as washing steps and carryover effect are discussed. The analyses were carried out using small sample volumes (400 mu L.), and in a short time period (3 min for the entire sample preparation step). The MEPS/LC-UV method was shown to be linear at concentrations ranging from the limit of quantification (LOQ) to 1000 ng mL(-1). The LOQ values ranged from 10 to 25 ng mL(-1). The inter-day precision of the method presented coefficient of the variation ranging from 1.3% to 8.7%. On the basis of analytical validation, it is shown that the MEPS/LC-UV methodology is adequate for antidepressant analysis, from therapeutic to toxic levels. In order to evaluate the proposed method for clinical use, the MEPS/LC-UV method was applied to analysis of plasma samples from elderly depressed patients. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The uptake of hexavalent chromium in free living floating aquatic macrophytes Eicchornia crassipes cultivated in non-toxic chromium-doped hydroponic solutions is presented. A Cr-uptake bioaccumulation experiment was carried out using healthy macrophytes grown in a temperature controlled greenhouse. Six samples of nutrient media and plants were collected during the 23 day experiment. Roots and leaves were acid digested with the addition of an internal Gallium standard, for thin film sample preparation and quantitative Cr analysis by PIXE method. The Cr(6+) mass uptake by the macrophytes reached up to 70% of the initial concentration, comparable to former results and literature data. The Cr-uptake data were described using a non-structural first order kinetic model. Due to low cost and high removal efficiency, living aquatic macrophytes E. crassipes are a viable biosorbent in an artificial wetland of a water effluent treatment plant. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The production of volatile organic compounds (VOC) by plants is well known. However, few scientific groups have studied VOC produced by green, brown and red algae. Headspace collection of volatiles and solid phase microextraction, as well as the traditional extraction by hydrodistillation combined with analytical chromatographic techniques (i.e., GC-MS), have significantly improved the investigation of VOC from plants and algae. The major volatile compounds found in seaweeds are hydrocarbons, terpenes, phenols, alcohols, aldehydes, ketones, esters, fatty acids and halogen or sulfur-containing compounds. This article presents an overview of VOC isolated from and identified in marine macro-algae. Focus is given to non-halogenated and non-sulfur volatile compounds, as well as strategies to analyze and identify algal VOC by GC-MS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sulfated-beta-cyclodextrin (s-beta-CD) modified reduced flow micellar electrokinetic chromatography (RF-MEKC) method was developed and validated for the determination of catechins in green tea. The optimal electrolyte consisted of 0.2% triethylamine, 50 mmol/L SDS and 0.8% s-beta-CD (pH = 2.9), allowing baseline separation of five catechins in 4 min. The samples and standards were injected at 0.6 psi for 5 s under constant voltage of -30 kV. Sample preparation simply involved extraction of 2 g of tea with 200 mL water at 95 C under constant stirring for 5 min. The method demonstrated excellent performance, with limits of detection (LOD) and quantification (LOQ) of 0.02-0.1 and 0.1-0.5 mu g/mL, respectively, and recovery percentages of 94-101%. The method was applied to six samples of Brazilian green tea infusions. Epigallocatechin gallate (23.4-112.4 mu g/mL) was the major component, followed by epigallocatechin (18.4-78.9 mu g/mL), epicatechin gallate (5.6-29.6 mu g/mL), epicatechin (4.6-14.5 mu g/mL) and catechin (3.2-8.2 mu g/mL). (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A capillary electrophoresis method for organic acids in wine was developed and validated. The optimal electrolyte consisted of 10 mmol/L 3,5-dinitrobenzoic acid (DNB) at pH 3.6 containing 0.2 mmol/L cetyltrimethylammonium bromide as flow reverser. DNB was chosen because it has an effective mobility similar to the organic acids under investigation, good buffering capacity at pH 3.6, and good chromophoric characteristics for indirect UV-absorbance detection at 254 nm. Sample preparation involved dilution and filtration. The method showed good performance characteristics: Linearity at 6 to 285 mg/L (r > 0.99); detection and quantification limits of 0.64 to 1.55 and 2.12 to 5.15 mg/L, respectively; separation time of less than 5.5 min. Coefficients of variation for ten injections were less than 5% and recoveries varied from 95% to 102%. Application to 23 samples of Brazilian wine confirmed good repeatability and demonstrated wide variation in the organic acid concentrations. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Direct analysis, with minimal sample pretreatment, of antidepressant drugs, fluoxetine, imipramine, desipramine, amitriptyline, and nortriptyline in biofluids was developed with a total run time of 8 min. The setup consists of two HPLC pumps, injection valve, capillary RAM-ADS-C18 pre-column and a capillary analytical C 18 column connected by means of a six-port valve in backflush mode. Detection was performed with ESI-MS/MS and only 1 mu m of sample was injected. Validation was adequately carried out using FLU-d(5) as internal standard. Calibration curves were constructed under a linear range of 1-250 ng mL(-1) in plasma, being the limit of quantification (LOQ), determined as 1 ng mL(-1), for all the analytes. With the described approach it was possible to reach a quantified mass sensitivity of 0.3 pg for each analyte (equivalent to 1.1-1.3 fmol), translating to a lower sample consumption (in the order of 103 less sample than using conventional methods). (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present work demonstrates the successful application of automated biocompatible in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC) for determination of interferon alpha(2a) (IFN alpha(2a)) in plasma samples for therapeutic drug monitoring. A restricted access material (RAM, protein-coated silica) was employed for preparation of a lab-made biocompatible in-tube SPME capillary that enables the direct injection of biological fluids as well as the simultaneous exclusion of macromolecules by chemical diffusion barrier and drug pre-concentration. The in-tube SPME variables, such as sample volume, draw/eject volume, number of draw-eject cycles, and desorption mode were optimized, to improve the sensitivity of the proposed method. The IFN alpha(2a) analyses in plasma sample were carried out within 25 min (sample preparation and LC analyses). The response of the proposed method was linear over a dynamic range, from 0.06 to 3.0 MIU mL(-1), with correlation coefficient equal to 0.998. The interday precision of the method presented coefficient of variation lower than 8%. The proposed automated method has adequate analytical sensitivity and selectivity for determination of IFN alpha(2a) in plasma samples for therapeutic drug monitoring. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A column switching LC method is presented for the analysis of fluoxetine (FLU) and norfluoxetine (NFLU) by direct injection of human plasma using a lab-made restricted access media (RAM) column. A RAM-BSA-octadecyl silica (C-18) column (40 min x 4.6 mm, 10 mu m) is evaluated in both backflush and foreflush elution modes and coupled with a C-18 lab-made (50 mm x 4.6 mm, 3 pm) analytical column in order to perform online sample preparation. Direct injection of 100 mu L, of plasma samples is possible with the developed approach. In addition, reduction of sample handling is obtained when compared with traditional liquid-liquid extraction (LLE) and SPE. The total analysis time is around 20 min. A LOQ of 15 ng/mL is achieved in a concentration range of 15-500 ng/mL, allowing the therapeutic drug monitoring of clinical samples. The precision values achieved are lower than 15% for all the evaluated points with adequate recovery and accuracy. Furthermore, no matrix interferences are found in the analysis and the proposed method shows to be an adequate alternative for analysis of FLU in plasma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conjugated linoleic acids (CLAs) are a group of linoleic acid isomers that are naturally found in food products originating from ruminants (meat and dairy). These acids have received special attention in recent years due to their potential human health benefits. Research efforts have been proposed to increase the CLA content in beef to improve public health. However, because there are more than 30 million beef cattle used each year by the American food industry, it will be necessary to ensure their content in a large number of samples. Therefore, it is important to have an inexpensive and rapid analytical method to measure CLA content in food products. Because gas chromatography (GC), a current popular method for measuring CLAs, is slow, this paper describes a nuclear magnetic resonance spectroscopy ((1)H NMR) method that is potentially >10 times faster than the GC method. Analyses show a correlation coefficient of 0.97, indicating the capacity of NMR to quantify the CLA content in beef samples. Furthermore, the method proposed herein is simple and does not require sophisticated sample preparation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Microwave-assisted sample preparation using diluted nitric acid solutions is an alternative procedure for digesting organic samples. The efficiency of this procedure depends on the chemical properties of the samples and in this work it was evaluated by the determination of crude protein amount. fat and original carbon. Soybeans grains, bovine blood. bovine muscle and bovine viscera were digested in a cavity-microwave oven using oxidant mixtures in different acid concentrations. The digestion efficiency was evaluated based on the determination of residual carbon content and element recoveries using inductively coupled plasma optical emission spectrometry (ICP OES). In order to determine the main residual organic compounds, the digests were characterized by nuclear magnetic resonance (1 H NMR). Subsequently, studies concerning separation of nitrobenzoic acid isomers were performed by ion pair reversed phase liquid chromatography using a C18 stationary phase, water:acetonitrile:methanol (75:20:5, v/v/v) +0.05% (v/v) TFA as mobile phase and ultraviolet detection at 254 nm. Sample preparation based on diluted acids proved to be feasible and a recommendable alternative for organic sample digestion, reducing both the reagent volumes and the variability of the residues as a result of the process of decomposition. It was shown that biological matt-ices containing amino acids, proteins and lipids in their composition produced nitrobenzoic acid isomers and other organic compounds after cleavage of chemical bonds. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the root canal preparation in flat-oval canals treated with either rotary or self-adjusting file (SAF) by using micro-tomography analysis. Methods: Forty mandibular incisors were scanned before and after root canal instrumentation with rotary instruments (n = 20) or SAF (n = 20). Changes in canal volume, surface area, and cross-sectional geometry were compared with preoperative values. Data were compared by independent sample t test and chi(2) test between groups and paired sample t test within the group (alpha = 0.05). Results: Overall, area, perimeter, roundness, and major and minor diameters revealed no statistical difference between groups (P > .05). In the coronal third, percentage of prepared root canal walls and mean increases of volume and area were significantly higher with SAF (92.0%, 1.44 +/- 0.49 mm(3), 0.40 +/- 0.14 mm(2), respectively) than rotary instrumentation (62.0%, 0.81 +/- 0.45 mm(3), 0.23 +/- 0.15 mm2, respectively) (P < .05). SAF removed dentin layer from all around the canal, whereas rotary instrumentation showed substantial untouched areas. Conclusions: In the coronal third, mean increases of area and volume of the canal as well as the percentage of prepared walls were significantly higher with SAF than with rotary instrumentation. By using SAF instruments, flat-oval canals were homogenously and circumferentially prepared. The size of the SAF preparation in the apical third of the canal was equivalent to those prepared with #40 rotary file with a 0.02 taper. (J Endod 2011;37:1002-1007)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes the evaluation of several parameters for the preparation of a tuna fish candidate as a reference material (RM) in order to measure the total As mass fraction by slurry sampling graphite furnace atomic absorption spectrometry (SLS-GF AAS) and slurry sampling hydride generation atomic absorption spectrometry (SLS-HG AAS). The main parameters investigated were the homogeneity, analyte segregation and composition during material production. For candidate RM preparation, tuna fish was collected at a local market, cleaned, freeze-dried and treated using different procedures as follows: (1) ground in a cutting mill and separated in different particle sizes (2) ground in cryogenic mill. The mass fraction of As in the cryogenically ground sample was (4.77 +/- A 0.19) mu g g(-1) for SLS-GF AAS and (4.61 +/- A 0.34) mu g g(-1) for SLS-HG AAS. The accuracy of the procedures was checked with tuna fish certified reference material (BCR 627) with recoveries of 102 and 94% for SLS-GF AAS and SLS-HG AAS, respectively. The homogeneity factor was calculated for different pretreatment procedures and for particle sizes in the range of 500-150 mu g, indicating good homogeneity, except for raw fish. There was no observed analyte segregation and no losses, no contamination and no changes in the microdistribution of material during preparation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polycarbonate membranes (PCM) of various pores sizes (400, 200, 100 and 50 nm) were used as templates for gold deposition. The electrodeposition from gold ions resulted in the formation of gold nanotubes when large pores size PCMs (400 and 200 nm) were used. On the other hand, gold nanowires were predominant for the PCMs with smaller pores size (100 and 50 nm). Surface-enhanced Raman scattering (SERS) from the probe molecule 4-mercaptopyridine (4-MPy) was obtained from all these nanostructures. The SERS efficiency of the substrates produced using the PC M templates were compared to two commonly used SERS platforms: a roughened gold electrode and gold nanostructures electrodeposited through organized polystyrene spheres (PSS). The SERS signal of the probe molecule increased as the pore diameter of the PCM template decreased. Moreover, the SERS efficiency from the nanostructures produced using 50 nm PCM templates was four and two times better than the signal from the roughened gold electrode and the PSS template, respectively. The SERS substrates prepared using PCM templates were more homogenous over a larger area (ca. 1 cm(2)), presented better spatial and sample to sample reproducibility than the other substrates. These results show that SERS substrates prepared using PCM templates are promising for the fabrication of planar SERS platforms for analytical/bioanalytical applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Composite electrodes were prepared using graphite powder and silicone rubber in different compositions. The use of such hydrophopic materials interned to diminish the swallowing observed in other cases when the electrodes are used in aqueous solutions for a long time. The composite was characterized for the response reproducibility, ohmic resistance, thermal behavior and active area. The voltammetric response in relation to analytes with known voltammetric behavior was also evaluated, always in comparison with the glassy carbon. The 70% (graphite, w/w) composite electrode was used in the quantitative determination of hydroquinone (HQ) in a DPV procedure in which a detection limit of 5.1 x 10(-8) mol L-1 was observed. HQ was determined in a photographic developer sample with errors lower then 1% in relation to the label value. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article addresses diagnostic parameters that should be assessed in the treatment of extraction sockets with dental implant placement by presenting three case reports that emphasize the relevance of the amount of remaining bone walls. Diagnosis was based on the analysis of clinical and radiographic parameters (e.g.: bone defect morphology, remaining bone volume, presence of infections on the receptor site). Case 1 presents a 5-wall defect in the maxillary right central incisor region with severe root resorption, which was treated with immediate implant placement. Cases 2 and 3 present, respectively, two- and three-wall bone defects that did not have indication for immediate implants. These cases were first submitted to a guided bone regeneration (GBR) procedure with bone graft biomaterial and membrane barriers, and the implants were installed in a second surgical procedure. The analysis of the preoperative periodontal condition of the adjacent teeth and bone defect morphology is extremely important because these factors determine the choice between immediate implant or GBR treatment followed by implant installation in a subsequent intervention.