32 resultados para STANDARD MODEL
Resumo:
Purpose: The aim of this study was to investigate the impact of acute PaCO(2) temporal variation on the standard base excess (SBE) value in critically ill patients. Methods: A total of 265 patients were prospectively observed; 158 were allocated to the modeling group, and 107 were allocated to the validation group. Two models were developed in the modeling group (one including and one excluding PaCO(2) as a variable determinant of SBE), and both were tested in the validation group. Results: In the modeling group, the mathematical model including SIDai, SIG, L-lactate, albumin, phosphate, and PaCO(2) had a predictive superiority in comparison with the model without PaCO(2) (R(2) = 0.978 and 0.916, respectively). In the validation group, the results were confirmed with significant F change statistics (R(2) change = 0.059, P < .001) between the model with and without PaCO(2). A high correlation (R = 0.99, P < .001) and agreement (bias = -0.25 mEq/L, limits of agreement 95% = -0.72 to 0.22 mEq/L) were found between the model-predicted SBE value and the SBE calculated using the Van Slyke equation. Conclusions: Acute PaCO(2), temporal variation is related to SBE changes in critically ill patients. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
There seems to be controversy on the anorectal sphincter presentation and anatomical division, as well as on its functional representation. Evaluation of the anorectal sphincter musculature has been achieved through several methods, including anorectal manometry and computerized tomography, but to date there is no experimental model allowing a detailed manometric study of this muscle complex. In this work, we have developed such a model, which should enable the manometric and radiographic study of the anatomical features and functional mechanisms of sphincteric injuries, as well as the assessment of drug effects on the anorectal musculature upon incontinence and constipation. Twenty-two piglets (aged 25-30 days, weighing 5-7 kg) were studied by anorectal manometry (rectoanal inhibitory reflex and vector volume) and computerized tomography (anorectal angle and anal canal length). The data obtained for the rectoanal inhibitory reflex, represented here as the average and standard deviation, were the following: relaxation duration = 14.75 +/- 3.62 s, sphincter basal pressure = 41.58 +/- 8.20 mmHg, relaxation index = 87.26 +/- 11.52%, speed of relaxation = 5.90 +/- 2.10 mm/s, and speed of relaxation recovery = 4.03 +/- 1.78 mm/s. As for the vector volume, results were as follows: vector volume = 2692.32 +/- 1298.12 mmHg(2) cm, sphincter length = 11.82 +/- 2.74 mm, high pressure zone length = 5.09 +/- 1.34 mm, maximum pressure = 61.50 +/- 20.58 mmHg, and asymmetry index = 43.50 +/- 10.03%. Radiographic evaluation led to the following results: anal canal length = 9.61 +/- 2.14 mm and anorectal angle = 137.91 +/- 7.75 degrees. The experimental model designed here allows both anorectal manometry and computerized tomography to be carried out in the same way it is performed in human beings, as long as animal sedation is strictly controlled.