71 resultados para Photothermal transparent transducer
Resumo:
Particle-image velocimetry (PIV) was used to visualize the flow within an optically transparent pediatric ventricular assist device (PVAD) under development in our laboratory The device studied is a diaphragm type pulsatile pump with an ejection volume of 30 ml per beating cycle intended for temporary cardiac assistance as a bridge to transplantation or recovery in children. Of particular interest was the identification of flow patterns, including regions of stagnation and/or strong turbulence that often promote thrombus formation and hemolysis, which can degrade the usefulness of such devices. For this purpose, phase-locked PIV measurements were performed in planes parallel to the diaphram that drives the flow in the device. The test fluid was seeded with 10 Am polystyrene spheres, and the motion of these particles was used to determine the instantaneous flow velocity distribution in the illumination plane. These measurements revealed that flow velocities up to 1.0 m/s can occur within the PVAD. Phase-averaged velocity fields revealed the fixed vortices that drive the bulk flow within the device, though significant cycle-to-cycle variability was also quite apparent in the instantaneous velocity distributions, most notably during the filling phase. This cycle-to-cycle variability can generate strong turbulence that may contribute to greater hemolysis. Stagnation regions have also been observed between the input and output branches of the prototype, which can increase the likelihood of thrombus formation. [DOI: 10.1115/1.4001252]
Resumo:
Hydrodynamic studies were conducted in a semi-cylindrical spouted bed column of diameter 150 mm, height 1000 mm, conical base included angle of 60 degrees and inlet orifice diameter 25 mm. Pressure transducers at several axial positions were used to obtain pressure fluctuation time series with 1.2 and 2.4 mm glass beads at U/U-ms from 0.3 to 1.6, and static bed depths from 150 to 600 mm. The conditions covered several flow regimes (fixed bed, incipient spouting, stable spouting, pulsating spouting, slugging, bubble spouting and fluidization). Images of the system dynamics were also acquired through the transparent walls with a digital camera. The data were analyzed via statistical, mutual information theory, spectral and Hurst`s Rescaled Range methods to assess the potential of these methods to characterize the spouting quality. The results indicate that these methods have potential for monitoring spouted bed operation.
Resumo:
ArtinM is a D-mannose binding lectin that has been arousing increasing interest because of its biomedical properties, especially those involving the stimulation of Th1 immune response, which confers protection against intracellular pathogens The potential pharmaceutical applications of ArtinM have motivated the production of its recombinant form (rArtinM) so that it is important to compare the sugar-binding properties of jArtinM and rArtinM in order to take better advantage of the potential applications of the recombinant lectin. In this work, a biosensor framework based on a Quartz Crystal Microbalance was established with the purpose of making a comparative study of the activity of native and recombinant ArtinM protein The QCM transducer was strategically functionalized to use a simple model of protein binding kinetics. This approach allowed for the determination of the binding/dissociation kinetics rate and affinity equilibrium constant of both forms of ArtinM with horseradish peroxidase glycoprotein (HRP), a N-glycosylated protein that contains the trimannoside Man alpha 1-3[Man alpha 1-6]Man, which is a known ligand for jArtinM (Jeyaprakash et al, 2004). Monitoring of the real-time binding of rArtinM shows that it was able to bind HRP, leading to an analytical curve similar to that of jArtinM, with statistically equivalent kinetic rates and affinity equilibrium constants for both forms of ArtinM The lower reactivity of rArtinM with HRP than jArtinM was considered to be due to a difference in the number of Carbohydrate Recognition Domains (CRDs) per molecule of each lectin form rather than to a difference in the energy of binding per CRD of each lectin form. (C) 2010 Elsevier B V. All rights reserved
Resumo:
Laponite-derived materials represent promising materials for optical applications. In this work, Eu(3+)- or Er(3+)-doped laponite xerogels and films were prepared from colloidal dispersion. Homogeneous, crack-free and transparent single layers were deposited on soda-lime substrates with a thickness of 10 mu m. Structural and spectroscopic properties were analyzed by thermal analyses, X-ray diffractometry, transmission electron microscopy, infrared spectroscopy, and luminescence spectroscopy. The addition of a rare earth ion to the laponite does not promote any changes in thermal stability or phase transition. Laponite clay was identified after annealing up to 500 degrees C, with a decrease in basal spacing when the annealing temperature is changed from 100 degrees C to 500 degrees C. Enstatite polymorphs and amorphous silicate phases were observed after heat treatment at 700 degrees C and 900 degrees C. Stationary and time-dependent luminescence spectra in the visible region for Eu(3+), and (5)D(0) lifetime are discussed in terms of thermal treatment and structural evolution. In the layered host, the Eu(3+) ions are distributed in many different local environments. However, Eu(3+) ions were found to occupy at least two symmetry sites, and the ions are preferentially incorporated into the crystalline enstatite for the materials annealed at 700 degrees C and 900 degrees C. A (5)D(0) lifetime of 1.3 ms and 3.1 ms was obtained for Eu(3+) ions in an amorphous silicate and crystalline MgSiO(3) local environment, respectively. Strong Er(3+) emission at the 1550 nm region was observed for the materials annealed at 900 degrees C, with a bandwidth of 44 nm. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Introduction. We describe a series of 10 children with intracranial hypertension complicating fulminant hepatic failure submitted to intracranial pressure (ICP) monitoring for intensive care an transplantation management. Patients and methods. Information from pediatrics patients acute liver failure admitted to our hospital was collected in a standard protocol form. We analyzed data from 10 patients, medium age 5.2 years old. In this period we studied aspects as ICP transducer used, number of days with ICP monitoring and complications of ICP monitoring. Results. Hepatitis A was diagnosed in five patients and hepatitis B in two cases. The initial ICP were 2 to 24 mmHg in transducer Seven patients died, four due to intracranial hypertension, included the patient operated for subdural hematoma, and three with transplantation failure. Only, a case of hematoma was verified. Conclusions. The application of ICP monitoring allows intensive care for aggressive ICP management. It can be used in children without adaptations. [REV NEUROL 2009: 48: 134-6]
Resumo:
BACKGROUND: Retention of airway secretions is a common and serious problem in ventilated patients. Treating or avoiding secretion retention with mucus thinning, patient-positioning, airway suctioning, or chest or airway vibration or percussion may provide short-term benefit. METHODS: In a series of laboratory experiments with a test-lung system we examined the role of ventilator settings and lung-impedance on secretion retention and expulsion. Known quantities of a synthetic dye-stained mucus simulant with clinically relevant properties were injected into a transparent tube the diameter of an adult trachea and exposed to various mechanical-ventilation conditions. Mucus-simulant movement was measured with a photodensitometric technique and examined with image-analysis software. We tested 2 mucus-simulant viscosities and various peak flows, inspiratory/ expiratory flow ratios, intrinsic positive end-expiratory pressures, ventilation waveforms, and impedance values. RESULTS: Ventilator settings that produced flow bias had a major effect on mucus movement. Expiratory How bias associated with intrinsic positive end-expiratory pressure generated by elevated minute ventilation moved mucus toward the airway opening, whereas intrinsic positive end-expiratory pressure generated by increased airway resistance moved the mucus toward the lungs. Inter-lung transfer of mucus simulant occurred rapidly across the ""carinal divider"" between interconnected test lungs set to radically different compliances; the mucus moved out of the low-compliance lung and into the high-compliance lung. CONCLUSIONS: The movement of mucus simulant was influenced by the ventilation pattern and lung impedance. Flow bias obtained with ventilator settings may clear or embed mucus during mechanical ventilation.
Resumo:
Objectives. The aim of this study was to assess the relationship between variables of physical assessment - muscular strength, flexibility and dynamic balance - with pain, pain threshold, and fibromyalgia symptoms (FM). Methods. Our sample consists of 55 women, with age ranging from 30 to 55 years (mean of 46.5, (standard deviation, SD=6.6)), mean body mass index (BMI) of 28.7(3.8) and diagnosed for FM according to the American College of Rheumatology criteria. Pain intensity was measured using a visual analogue scale (VAS) and pain threshold (PT) using Fisher`s dolorimeter. FM symptoms were assessed by the Fibromyalgia Impact Questionnaire (FIQ); flexibility by the third finger to floor test (3FF); the muscular strength index (MSI) by the maximum volunteer isometric contraction at flexion and extension of right knee and elbow using a force transducer, dynamic balance by the time to get up and go (TUG) test and the functional reach test (FRT). Data were analysed using Pearson`s correlation, as well as simple and multivariate regression tests, with significance level of 5%. Results. PT and FIQ were weakly but significantly correlated with the TUG, MSI and 3FF as well as VAS with the TUG and MSI (p<0.05). VAS, PT and FIQ was not correlated with FRT. Simple regression suggests that, alone, TUG, FR, MSI and 3FF are low predictors of VAS, PT and FIQ. For the VAS, the best predictive model includes TUG and MSI, explaining 12.6% of pain. variability. For TP and total symptoms, as obtained by the FIQ, most predictive model includes 3FF and MSI, which respectively respond by 30% and 21% of the variability. Conclusion. Muscular strength, flexibility and balance are associated with pain, pain threshold, and symptoms in FM patients.
Resumo:
Background: GH insensitivity (GHI) syndrome caused by STAT5B mutations was recently reported, and it is characterized by extreme short stature and immune dysfunction. Treatment with recombinant human IGF1 (rhIGF1) is approved for patients with GHI, but the growth response to this therapy in patients with STAT5B mutations has not been reported. Objectives: To report the clinical features, molecular findings, and the short-term growth response to rhIGF1 therapy in patients with STAT5B mutation. Subjects and methods: Hormonal and immunological evaluations were performed in two male siblings with GHI associated with atopic eczema, interstitial lung disease, and thrombocytopenic purpura. STAT5B genes were directly sequenced. The younger sibling was treated with rhIGF1 at a dose of 110 mu g/kg BID. Results: Both siblings had laboratory findings compatible with GHI associated with hyperprolactinemia. Lymphopenia and reduced number of natural killer cells without immunoglobulin abnormalities were observed. STAT5B sequence revealed a homozygous frameshift mutation (p.L142fsX161) in both siblings. The younger sibling (9.9 years of age) was treated with rhIGF1 at appropriate dosage, and he did not present any significant change in his growth velocity (from 2.3 to 3.0 cm/year after 1.5 years of therapy). The presence of a chronic illness could possibly be responsible for the poor result of rhIGF1 treatment. Further studies in patients with STAT5B defects are necessary to define the response to rhIGF1 treatment in this disorder. Conclusion: GHI associated with immune dysfunction, especially interstitial lung disease, and hyperprolactinemia is strongly suggestive of a mutation in STAT5B in both sexes.
Resumo:
Objective. The purpose of this series was to determine the frequency of abductor mechanism avulsion by sonography after total hip arthroplasty with the Hardinge approach (J Bone Joint Surg Br 1982; 64:17-19) and its relationship to the presence of insufficiency of this musculature in the postoperative period. Methods. Thirty-four consecutive patients were prospectively accessed in the postoperative period of hip arthroplasty by the Trendelenburg test, hip sonography, and abductor muscle electromyography. In patients who were found to have clinical insufficiency of the abductor musculature, we also measured the femoral offset in the preoperative and postoperative radiographs. Hip sonography was performed by an experienced musculoskeletal radiologist blinded to the other tests, and the tendons of the gluteus medius and gluteus minimus were visualized on longitudinal and transverse sections with a 7- to 10-MHz linear transducer. Results. Eight patients presented clinical insufficiency of the abductor musculature as detected by the Trendelenburg test. Four of these 8 patients with abductor insufficiency presented tendinous avulsion detected by sonography. One of the 4 patients with abductor insufficiency and normal sonographic findings had a decrease in the femoral offset caused by the arthroplasty itself. Two patients presented electromyographic changes of the abductor musculature, with no tendinous avulsion detected by sonography and no abductor insufficiency. Conclusions. We concluded that in patients undergoing total hip arthroplasty by the Hardinge approach in whom insufficiency of the abductor musculature develops, sonography is an interesting method of investigation because it identified the cause of this problem in most of our patients.
Resumo:
Background: There is only limited knowledge on how the quantification of valvular regurgitation by color Doppler is affected by changing blood viscosity. This study was designed to evaluate the effect of changing blood viscosity on the vena contracta width using an in vitro model of valvular insufficiency capable of providing ample variation in the rate and stroke volume. Methods: We constructed a pulsatile flow model filled with human blood at varying hematocrit (15%, 35%, and 55%) and corresponding blood viscosity (blood/water viscosity: 2.6, 4.8, 9.1) levels in which jets were driven through a known orifice (7 mm(2)) into a 110 mL compliant receiving chamber (compliance: 2.2 mL/mmHg) by a pulsatile pump. In addition, we used variable pump stroke volumes (5, 7.5, and 10 mL) and rates (40, 60, and 80 ppm). Vena contracta region was imaged using a 3.5 MHz transducer. Pressure and volume in the flow model were kept constant during each experimental condition, as well as ultrasound settings. Results: Blood viscosity variation in the experimental range did not induce significant changes in vena contracta dimensions. Also, vena contracta width did not change from normal to low hematocrit and viscosity levels. A very modest increase only in vena contracta dimension was observed at very high level of blood viscosity when hematocrit was set to 55% . Pump rate, in the evaluated range, did not influence vena contracta width. These results in controlled experimental settings suggest that the vena contracta is an accurate quantitative method for quantifying valvular regurgitation even when this condition is associated with anemia, a frequent finding in patients with valvular heart disease.
Resumo:
In the present study, we used the electronic version of the von Frey test to investigate the role of cytokines (TNF-alpha and IL-1 beta) and chemokines (KC/CXCL-1) in the genesis of mechanical hypernociception during antigen-induced inflammation in mice. The nociceptive test consisted of evoking a hindpaw flexion reflex with a hand-held force transducer (electronic anesthesiometer) adapted with a 0.5 mm(2) polypropylene tip. The intraplantar administration of methylated bovine serum albumin (mBSA) in previously immunized (IM), but not in sham-immunized (SI) mice, induced mechanical hypernociception in a dose-dependant manner. Hypernociception induced by antigen was reduced in animals pretreated with IL-lra and reparixin (a non-competitive allosteric inhibitor of CXCR2), and in TNF receptor type 1 deficient (TNFR1-/-) mice. Consistently, antigen challenge induced a time-dependent release of TNF-alpha, IL-1 beta and KC/CXCL-1 in IM, but not in SI, mice. Consistently, antigen challenge induced a time-dependent release of TNF-alpha, IL-1 beta and KC/CXCL-1 in IM, but not in SI, mice. The increase in TNF-alpha levels preceded the increase in IL-1 beta and KC/CXCL1. Antigen-induced release of IL-1 beta and KC/CXCL1 was reduced in TNFR1-/- mice, and TNF-alpha induced hypernociception was inhibited by IL-lra and reparixin. Hypernociception induced by IL-1 beta in immunized mice was inhibited by indomethacin, whereas KC/CXCL1-induced hypernociception was inhibited by indomethacin and guanethidine, Antigen-induced hypernociception was reduced by indomethacin and guanethidine and abolished by the two drugs combined. Together, these results suggest that inflammation associated with an adaptive immune response induces hypernociception that is mediated by an initial release of TNF-alpha, which triggers that subsequent release of IL-1 beta and KC/CXCL1. The latter cytokines in turn stimulate the release of the direct-acting final mediator, prostanoids and sympathetic amines. (C) 2008 European Federation of Chapters of the International Association for the Study of Pain. Published by Elsevier Ltd. All rights reserved.
Resumo:
Leptin resistance and desensitization of hypophagia during prolonged inflammatory challenge. Am J Physiol Endocrinol Metab 300: E858-E869, 2011. First published February 22, 2011; doi: 10.1152/ajpendo.00558.2010.-Acute exposure to bacterial lipopolysaccharide (LPS) is a potent inducer of immune response as well as hypophagia. Nevertheless, desensitization of responses to LPS occurs during long-term exposure to endotoxin. We induced endotoxin tolerance, injecting repeated (6LPS) LPS doses compared with single (1LPS) treatment. 1LPS, but not 6LPS group, showed decreased food intake and body weight, which was associated with an increased plasma leptin and higher mRNA expression of OB-Rb, MC4R, and SOCS3 in the hypothalamus. Hypophagia induced by 1LPS was associated with lower levels of 2-arachidonoylglycerol (2-AG), increased number of p-STAT3 neurons, and decreased AMP-activated protein kinase (AMPK) activity. Desensitization of hypophagia in the 6LPS group was related to high 2-AG, with no changes in p-STAT3 or increased p-AMPK. Leptin decreased food intake, body weight, 2-AG levels, and AMPK activity and enhanced p-STAT3 in control rats. However, leptin had no effects on 2-AG, p-STAT3, or p-AMPK in the 1LPS and 6LPS groups. Rats treated with HFD to induce leptin resistance showed neither hypophagia nor changes in p-STAT3 after 1LPS, suggesting that leptin and LPS recruit a common signaling pathway in the hypothalamus to modulate food intake reduction. Desensitization of hypophagia in response to repeated exposure to endotoxin is related to an inability of leptin to inhibit AMPK phosphorylation and 2-AG production and activate STAT3. SOCS3 is unlikely to underlie this resistance to leptin signaling in the endotoxin tolerance. The present model of prolonged inflammatory challenge may contribute to further investigations on mechanisms of leptin resistance.
Resumo:
Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.
Resumo:
The present study aimed investigate the age and gender influence on maximal molar bite force and at outlining the criteria for normal masticatory muscle development in a sample of 177 Brazilian Caucasian dentate individuals aged 7-80 years divided into five age groups: I(7-12 years), II (13-20 years), III (21-40 years), IV (41-60 years), and V (61-80 years). Except for Group V, which comprised nine women and eight men, all groups were equally divided in respect to gender (20 M/20 F). Bite force was recorded with a mouth-adapted 1000 N dynamometer and the highest out of three records was regarded as the maximal bite force. The data were submitted to multivariate statistical analysis (SPSS 17.0 p < 0.05). Effects of group and gender were found, but no interactions between them. The ANOVA showed significant differences between groups bilaterally. Bonferroni`s test showed that group I had significantly lower bite force means at both sides as compared to all groups, except group V. No differences were found between the left and right sides. In all the groups, gender was found to be a significant factor associated with maximal bite force. A global comparison including all the subjects and measures showed that the means of men were approximately 30% higher than those of women, within-group comparisons yielded similar results in all groups. Muscle thickness was measured with a SonoSite Titan ultrasound tool using a high-resolution real-time 56 mm/10 MHz linear-array transducer. Three ultrasound images were obtained from the bilateral masseter and temporal muscles at rest and at maximal voluntary contraction. The means of the three measures in each clinical condition were analyzed with multivariate statistical analysis (SPSS 17.0 p < 0.05). A gradual increase in thickness of the masseter and temporal muscles was found both at rest and maximal voluntary contraction for groups I to IV, whereas a decrease in muscle thickness was observed in group V. Multivariate analysis showed that in both conditions there was an effect of group and gender. The study of the development of the stomatognathic system in relation to age and gender can provide useful data for the identification of normal and impaired functioning patterns. The results of this study indicate that age and gender are associated with structural and functional alterations in the muscles of the stomatognathic system. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Described in this article is a novel device that facilitates study of the cross-sectional anatomy of the human head. In designing our device, we aimed to protect sections of the head from the destructive action of handling during anatomy laboratory while also ensuring excellent visualization of the anatomic structures. We used an electric saw to create 15-mm sections of three cadaver heads in the three traditional anatomic planes and inserted each section into a thin, perforated display box made of transparent acrylic material. The thin display boxes with head sections are kept in anatomical order in a larger transparent acrylic storage box containing formaldehyde solution, which preserves the specimens but also permits direct observation of the structures and their anatomic relationships to each other. This box-within-box design allows students to easily view sections of a head in its anatomical position as well as to examine internal structures by manipulating individual display boxes without altering the integrity of the preparations. This methodology for demonstrating cross-section anatomy allows efficient use of cadaveric material and technician time while also giving learners the best possible handling and visualization of complex anatomic structures. Our approach to teaching cross-sectional anatomy of the head can be applied to any part of human body, and the value of our device design will only increase as more complicated understandings of cross-sectional anatomy are required by advances and proliferation of imaging technology. Anat Sci Educ 3: 141-143, 2010. (C) 2010 American Association of Anatomists.