40 resultados para On-line Measurement


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new procedure for spectrofluorimetric determination of free and total glycerol in biodiesel samples is presented. It is based on the oxidation of glycerol by periodate, forming formaldehyde, which reacts with acetylacetone, producing the luminescent 3,5-diacetyl-1,4-dihydrolutidine. A flow system with solenoid micro-pumps is proposed for solution handling. Free glycerol was extracted off-line from biodiesel samples with water, and total glycerol was converted to free glycerol by saponification with sodium ethylate under sonication. For free glycerol, a linear response was observed from 5 to 70 mg L(-1) with a detection limit of 0.5 mg L(-1), which corresponds to 2 mg kg(-1) in biodiesel. The coefficient of variation was 0.9% (20 mg L(-1), n = 10). For total glycerol, samples were diluted on-line, and the linear response range was 25 to 300 mg L(-1). The detection limit was 1.4 mg L(-1) (2.8 mg kg(-1) in biodiesel) with a coefficient of variation of 1.4% (200 mg L(-1), n = 10). The sampling rate was ca. 35 samples h(-1) and the procedure was applied to determination of free and total glycerol in biodiesel samples from soybean, cottonseed, and castor beans.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There is little empirical data about the impact of digital inclusion on cognition among older adults. This paper aimed at investigating the effects of a digital inclusion program in the cognitive performance of older individuals who participated in a computer learning workshop named ""Idosos On-Line`` (Elderly Online). Forty-two aged individuals participated in the research study: 22 completed the computer training workshop and 20 constituted the control group. All subjects answered a sociodemographic questionnaire and completed the Addenbrooke`s cognitive examination, revised (ACE-R), which examines five cognitive domains: orientation and attention, memory, verbal fluency, language, and visuo-spatial skills. It was noted that the experimental group`s cognitive performance significantly improved after the program, particularly in the language and memory domains, when compared to the control group. These findings suggest that the acquisition of new knowledge and the use of a new tool, that makes it possible to access the Internet, may bring gains to cognition. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The project of Information Architecture is one of the initial stages of the project of a website, thus the detection and correction of errors in this stage are easier and time-saving than in the following stages. However, to minimize errors for the projects of information architecture, a methodology is necessary to organize the work of the professional and guarantee the final product quality. The profile of the professional who works with Information Architecture in Brazil has been analyzed (quantitative research by means of a questionnaire on-line) as well as the difficulties, techniques and methodologies found in his projects (qualitative research by means of interviews in depth with support of the approaches of the Sense-Making). One concludes that the methodologies of projects of information architecture need to develop the adoption of the approaches of Design Centered in the User and in the ways to evaluate its results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Optical monitoring systems are necessary to manufacture multilayer thin-film optical filters with low tolerance on spectrum specification. Furthermore, to have better accuracy on the measurement of film thickness, direct monitoring is a must. Direct monitoring implies acquiring spectrum data from the optical component undergoing the film deposition itself, in real time. In making film depositions on surfaces of optical components, the high vacuum evaporator chamber is the most popular equipment. Inside the evaporator, at the top of the chamber, there is a metallic support with several holes where the optical components are assembled. This metallic support has rotary motion to promote film homogenization. To acquire a measurement of the spectrum of the film in deposition, it is necessary to pass a light beam through a glass witness undergoing the film deposition process, and collect a sample of the light beam using a spectrometer. As both the light beam and the light collector are stationary, a synchronization system is required to identify the moment at which the optical component passes through the light beam.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

On-line leak detection is a main concern for the safe operation of pipelines. Acoustic and mass balance are the most important and extensively applied technologies in field problems. The objective of this work is to compare these leak detection methods with respect to a given reference situation, i.e., the same pipeline and monitoring signals acquired at the inlet and outlet ends. Experimental tests were conducted in a 749 m long laboratory pipeline transporting water as the working fluid. The instrumentation included pressure transducers and electromagnetic flowmeters. Leaks were simulated by opening solenoid valves placed at known positions and previously calibrated to produce known average leak flow rates. Results have clearly shown the limitations and advantages of each method. It is also quite clear that acoustics and mass balance technologies are, in fact, complementary. In general, an acoustic leak detection system sends out an alarm more rapidly and locates the leak more precisely, provided that the rupture of the pipeline occurs abruptly enough. On the other hand, a mass balance leak detection method is capable of quantifying the leak flow rate very accurately and of detecting progressive leaks.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The volumetric reconstruction technique presented in this paper employs a two-camera stereoscopic particle image velocimetry (SPIV) system in order to reconstruct the mean flow behind a fixed cylinder fitted with helical strakes, which are commonly used to suppress vortex-induced vibrations (VIV). The technique is based on the measurement of velocity fields at equivalent adjacent planes that results in pseudo volumetric fields. The main advantage over proper volumetric techniques is the avoidance of additional equipment and complexity. The averaged velocity fields behind the straked cylinders and the geometrical periodicity of the three-start configuration are used to further simplify the reconstruction process. Two straked cylindrical models with the same pitch (p = 10d) and two different heights (h = 0.1 and 0.2d) are tested. The reconstructed flow shows that the strakes introduce in the wake flow a well-defined wavelength of one-third of the pitch. Measurements of hydrodynamic forces, fluctuating velocity, vortex formation length, and vortex shedding frequency show the interdependence of the wake parameters. The vortex formation length is increased by the strakes, which is an important effect for the suppression of vortex-induced vibrations. The results presented complement previous investigations concerning the effectiveness of strakes as VIV suppressors and provide a basis of comparison to numerical simulations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes an analytical method for the rapid screening and identification of the phenolic constituents present in the polar extracts of different Lychnophora spp. using LC-UV/DAD-ESI-MS and LC-UV/DAD-ESI-MS/MS. Compounds were identified based on UV, retention time, MS experiments and MS/MS of precursor ion or standard. On-line phytochemical investigation of Lychnophora spp. allowed for the identification of flavonoids, chlorogenic acid derivatives and lactones. Some of the observed compounds were for the first time identified in Lychnophora species in a fast analytical procedure. The data obtained here may be helpful to the investigation of polar constituents from other Lychnophora species.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple method with a fast sample preparation procedure for total and inorganic mercury determinations in blood samples is proposed based on flow injection cold vapor inductively coupled plasma mass spectrometry (FI-CVICP-MS). Aliquots of whole blood (500 mL) are diluted 1 + 1 v/v with 10.0% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 3 h at room temperature and then further diluted 1 + 4 v/v with 2.0% v/v HCl. The inorganic Hg was released by online addition of L-cysteine and then reduced to elemental Hg by SnCl(2). On the other hand, total mercury was determined by on-line addition of KMnO(4) and then reduced to elemental Hg by NaBH(4). Samples were calibrated against matrix-matching. The method detection limit was found to be 0.80 mu g L(-1) and 0.08 mu g L(-1) for inorganic and total mercury, respectively. Sample throughput is 20 samples h(-1). The method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). For additional validation purposes, human whole blood samples were analyzed by the proposed method and by an established CV AAS method, with no statistical difference between the two techniques at 95% confidence level on applying the t-test.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the effect of the environment and the observer on the measurement of blood pressure (BP) as well as to compare home BP (HBP) and ambulatory BP (ABP) measurements in the diagnosis of white coat hypertension (WCH) and masked hypertension (MH) in children and adolescents with hypertension (HT). METHODS BP of 40 patients with HT (75% of which had secondary HT and were on antihypertensive medication), mean age 12.1 years was evaluated through casual measurements at the clinic and at the HT unit, HBP for 14 days with the OMRON HEM 705 CP monitor (Omron, Tokyo, Japan) and ABP performed with SPACELABS 90207 (Spacelabs, Redmond, WA), for 24 h. RESULTS HT was diagnosed at the doctor`s office by ABP and HBP in 30/40, 27/40, and 31/40 patients, respectively. Based on office BP and ABP, 60% of patients were normotensive, 17.5% HT, 7.5% had WCH, and 15% had MH, whereas based on office BP and HBP 65, 12.5, 10, and 12.5% of patients were classified according to these diagnoses, respectively. There was considerable diagnostic agreement of HT by ABP and HBP (McNemar test, P < 0.01) (kappa = 0.56). CONCLUSION In hypertensive children and adolescents, HBP and ABP present comparable results. HBP appears to be a useful diagnostic test for the detection of MH and WCH in pediatric patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bovine leukemia virus (BLV) is among the most widespread livestock pathogens in many countries. Despite advances in understanding the pathogenesis of this disease, little is known about the involvement of oxidative stress. Therefore, this study examined the antioxidant status and the markers of oxidative stress in BLV-infected dairy cows. BLV infection was associated with an increase in triacylglycerol levels, a decrease in glutathione peroxidase (GSH-Px) activity and a tendency toward lower superoxide dismutase activity in the infected animals. No significant difference was observed in other markers of oxidative stress (i.e., conjugated dienes, hydroperoxides and malondialdehyde) in the infected animals compared to controls. A novel method for the analysis of oxidative stress, Z-scan based on the measurement of the mean-value of 9 in low density lipoprotein indicated that the infected animals had low-density lipoprotein particles that were slightly less modified than those from the healthy group. Thus, we conclude that BLV infection is associated with a selective decrease in GSH-Px activity without any alteration in the common plasma markers of oxidative stress. (C) 2011 Elsevier B.V. All rights reserved.