63 resultados para Harmonic and anharmonic oscillators
Resumo:
Multifunctional structures are pointed out as an important technology for the design of aircraft with volume, mass, and energy source limitations such as unmanned air vehicles (UAVs) and micro air vehicles (MAVs). In addition to its primary function of bearing aerodynamic loads, the wing/spar structure of an UAV or a MAV with embedded piezoceramics can provide an extra electrical energy source based on the concept of vibration energy harvesting to power small and wireless electronic components. Aeroelastic vibrations of a lifting surface can be converted into electricity using piezoelectric transduction. In this paper, frequency-domain piezoaeroelastic modeling and analysis of a canti-levered platelike wing with embedded piezoceramics is presented for energy harvesting. The electromechanical finite-element plate model is based on the thin-plate (Kirchhoff) assumptions while the unsteady aerodynamic model uses the doublet-lattice method. The electromechanical and aerodynamic models are combined to obtain the piezoaeroelastic equations, which are solved using a p-k scheme that accounts for the electromechanical coupling. The evolution of the aerodynamic damping and the frequency of each mode are obtained with changing airflow speed for a given electrical circuit. Expressions for piezoaeroelastically coupled frequency response functions (voltage, current, and electrical power as well the vibratory motion) are also defined by combining flow excitation with harmonic base excitation. Hence, piezoaeroelastic evolution can be investigated in frequency domain for different airflow speeds and electrical boundary conditions. [DOI:10.1115/1.4002785]
Resumo:
Multipulse rectifier topologies based on autoconnections are increasingly applied as interface stages between mains and power electronics converters. These topologies are attractive and cost-effective solutions for meeting the requirements of low total harmonic distortion of line current and high power factor. Furthermore, as only a small fraction of the total power required by the load is processed in the magnetic core, the overall resulting volume and weight are reduced. This paper proposes a mathematical analysis based on phasor diagrams that results in a single and general expression capable of unifying all delta and wye step-up or step-down autotransformer connections for 12-and 18-pulse ac-dc converters. The expression obtained allows the choice of a wide range of input/output voltage ratio for step-up or step-down autotransformer, and this general expression is also presented in a graphical form for each converter. Moreover, it simplifies the procedure for determining turn ratios and polarities for all windings of the autotransformer. A routine for easy and fast calculations is developed and validated by a design example. Finally, experimental results are presented along with comments on a 6-kW 220-V line voltage, 400-V rectified voltage, and 18-pulse delta-autoconnected prototype.
Resumo:
This paper presents a new methodology to estimate unbalanced harmonic distortions in a power system, based on measurements of a limited number of given sites. The algorithm utilizes evolutionary strategies (ES), a development branch of evolutionary algorithms. The problem solving algorithm herein proposed makes use of data from various power quality meters, which can either be synchronized by high technology GPS devices or by using information from a fundamental frequency load flow, what makes the overall power quality monitoring system much less costly. The ES based harmonic estimation model is applied to a 14 bus network to compare its performance to a conventional Monte Carlo approach. It is also applied to a 50 bus subtransmission network in order to compare the three-phase and single-phase approaches as well as the robustness of the proposed method. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The approach presented in this paper consists of an energy-based field-circuit coupling in combination with multi-physics simulation of the acoustic radiation of electrical machines. The proposed method is applied to a special switched reluctance motor with asymmetric pole geometry to improve the start-up torque. The pole shape has been optimized, subject to low torque ripple, in a previous study. The proposed approach here is used to analyze the impact of the optimization on the overall acoustic behavior. The field-circuit coupling is based on a temporary lumped-parameter model of the magnetic part incorporated into a circuit simulation based on the modified nodal analysis. The harmonic force excitation is calculated by means of stress tensor computation, and it is transformed to a mechanical mesh by mapping techniques. The structural dynamic problem is solved in the frequency domain using a finite-element modal analysis and superposition. The radiation characteristic is obtained from boundary element acoustic simulation. Simulation results of both rotor types are compared, and measurements of the drive are presented.
Resumo:
This paper presents a new methodology to estimate harmonic distortions in a power system, based on measurements of a limited number of given sites. The algorithm utilizes evolutionary strategies (ES), a development branch of evolutionary algorithms. The main advantage in using such a technique relies upon its modeling facilities as well as its potential to solve fairly complex problems. The problem-solving algorithm herein proposed makes use of data from various power-quality (PQ) meters, which can either be synchronized by high technology global positioning system devices or by using information from a fundamental frequency load flow. This second approach makes the overall PQ monitoring system much less costly. The algorithm is applied to an IEEE test network, for which sensitivity analysis is performed to determine how the parameters of the ES can be selected so that the algorithm performs in an effective way. Case studies show fairly promising results and the robustness of the proposed method.
Resumo:
Distribution of timing signals is an essential factor for the development of digital systems for telecommunication networks, integrated circuits and manufacturing automation. Originally, this distribution was implemented by using the master-slave architecture with a precise master clock generator sending signals to phase-locked loops (PLL) working as slave oscillators. Nowadays, wireless networks with dynamical connectivity and the increase in size and operation frequency of the integrated circuits suggest that the distribution of clock signals could be more efficient if mutually connected architectures were used. Here, mutually connected PLL networks are studied and conditions for synchronous states existence are analytically derived, depending on individual node parameters and network connectivity, considering that the nodes are nonlinear oscillators with nonlinear coupling conditions. An expression for the network synchronisation frequency is obtained. The lock-in range and the transmission error bounds are analysed providing hints to the design of this kind of clock distribution system.
Resumo:
A rigorous derivation of non-linear equations governing the dynamics of an axially loaded beam is given with a clear focus to develop robust low-dimensional models. Two important loading scenarios were considered, where a structure is subjected to a uniformly distributed axial and a thrust force. These loads are to mimic the main forces acting on an offshore riser, for which an analytical methodology has been developed and applied. In particular, non-linear normal modes (NNMs) and non-linear multi-modes (NMMs) have been constructed by using the method of multiple scales. This is to effectively analyse the transversal vibration responses by monitoring the modal responses and mode interactions. The developed analytical models have been crosschecked against the results from FEM simulation. The FEM model having 26 elements and 77 degrees-of-freedom gave similar results as the low-dimensional (one degree-of-freedom) non-linear oscillator, which was developed by constructing a so-called invariant manifold. The comparisons of the dynamical responses were made in terms of time histories, phase portraits and mode shapes. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
We have found photoinduced second harmonic generation at wavelength 1064 nm during bicolor Nd:YAG laser coherent treatment of TeO(2)-ZnO and GeO(2)-PbO amorphous films. The maximally achieved second order susceptibility was equal to about 1.02 pm/V. Correlation of the induced second order susceptibility with local sample heating and induced birefringence may indicate an occurrence of local phase transitions from amorphous glass-like phase to non-centrosymmetry metastable phases. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Electron beam induced second harmonic generation (SHG) is studied in Er(3+) doped PbO-GeO(2) glasses containing silver nanoparticles with concentrations that are controlled by the heat-treatment of the samples. The SHG is observed at T = 4.2 K using a p-polarized laser beam at 1064 nm. Enhancement of the SHG is observed in the samples that are submitted to electron beam incidence. The highest value of the nonlinear susceptibility, 2.08 pm/V, is achieved for the sample heat-treated during 72 h and submitted to an electron beam current of 15 nA. The samples that were not exposed to the electron beam present a susceptibility of a parts per thousand 0.5 pm/V.
Resumo:
In this work we present an analysis of harmonic distortion (HD) in graded-channel (GC) gate-all-a round (GAA) devices operating in saturation region for analog applications. The study has been performed through device characterization and two-dimensional process and device simulations. The overall study has been done on the total and third order HDs. When applied in the saturation regime as an amplifier, the GC outperforms conventional GAA transistors presenting simultaneously higher transconductance, lower drain output conductance and more than 15 dB improved linearity. The influence of channel length reduction on the H D is also analyzed. Although slight linearity degradation is observed in both the conventional and the GC devices when reducing the channel length, the HD presented by the GC transistor is significantly lower than the one showed by conventional device for any Studied channel length. This allows AC input signal amplitude up to 20 times higher than the conventional GAA for a same specified distortion level. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Background: Insulin resistance and obesity are recognized as left ventricular (LV) mass determinants independent of blood pressure (BP). Prevalence of LV hypertrophy (LVH) and the relationship between LV mass to body composition and metabolic variables were evaluated in normotensive individuals as participants of a population-based study. Methods: LV mass was measured using the second harmonic image by M-mode 2D guided echocardiography in 326 normotensive subjects (mean 47 +/- 9.4 years). Fasting serum lipids and glucose, BP, body composition and waist circumference (WC) were recorded during a clinic visit. Results: Applying a normalization criterion not related to body weight (g/height raised to the power 2.7) and the cut-off points of 47.7 (men) and 46.6 g/m(2.7) (women), LVH was found in 7.9% of the sample. Univariate analysis showed LV mass (g/m(2.7)) related to age, body mass index (BMI), WC, fat and lean body mass, systolic and diastolic BP, and metabolic variables (cholesterol, HDL-c, triglycerides and glucose). In multivariate analysis only BMI and age-adjusted systolic BP remained as independent predictors of LV mass, explaining 31% and 5% of its variability. Removing BMI from the model, WC, age-adjusted systolic BP and lean mass remained independent predictors, explaining 25.0%, 4.0% and 1.5% of LV mass variability, respectively. After sex stratification, LV mass predictors were WC (8%) and systolic BP (5%) in men and WC (36%) and systolic BP (3%) in women. Conclusion: BMI in general and particularly increased abdominal adiposity (WC as surrogate) seems to account for most of LV mass increase in normotensive individuals, mainly in women. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background: Zenker`s diverticulum (ZD) is a rare condition with a reported prevalence of 0.01% to 0.11% in the general population. Endoscopic treatment consists of the division of the septum between the diverticulum and the esophagus, within which the cricopharyngeal muscle is contained. Diathermic monopolar current, argon plasma coagulation, and laser have been used to incise the muscular septum with satisfactory results. The main limitation of endoscopic treatment is the occurrence of complications. Perforation and hemorrhage are reported in as many as 23% and 10% of patients, respectively. Objective: The aim of this study was to use the technique of endoscopic diverticulotomy by using a harmonic scalpel in patients with ZD and to demonstrate the feasibility of using flexible and rigid devices in ZD treatment. Design: Case series study. Standard protocol was used for patient management, endoscopic procedure, and data collection. Setting: Single endoscopist demonstrating preliminary results. Patients: Five patients (4 men; median standard deviation [SD] age 69.6 +/- 9.06 years, range 59-83 years) with ZD were treated with this technique. All patients reported dysphagia and halitosis. The diagnosis was based on clinical, endoscopic, and radiographic findings. Interventions: All patients received general anesthesia and were placed in the left lateral position. A standard videogastroscope (9.8 mm) and a stiff guidewire were used to insert and achieve an adequate exposure of the ZD septum. The septum was divided using a harmonic scalpel under thin endoscope (5.2 mm) visualization through a soft diverticuloscope. Main Outcome Measurement: Feasibility of an endoscopic technique by using rigid and flexible devices to treat ZD. Results: Four patients (80%) were successfully treated in 1 session. The median SD size of the diverticulum was 3.6 +/- 0.89 cm (range 3-5 cm). Median SD procedure time was 17.33 +/- 2.33 minutes (range 15-20 minutes) in 6 procedures. No hemorrhage or perforation occurred. One patient (20%) required a second session to complete dissection of the ZD septum. All patients demonstrated improvement of dysphagia score after treatment. Limitations: Small case series design. Conclusions: Endoscopic treatment of ZD by harmonic scalpel through a soft diverticuloscope was feasible and effective in this small case series. Larger studies are warranted to further evaluate this technique.
Resumo:
Bisegmentectomy 7-8 is feasible even in the absence of a large inferior right hepatic vein. To our knowledge, this operation has never been performed by laparoscopy. This study was designed to present video of pure laparoscopic bisegmentectomy 7-8 and bisegmentectomy 2-3 in one-stage operation for bilateral liver metastasis. A 67-year-old man with metachronous bilobar colorectal liver metastasis was referred for surgical treatment after neoadjuvant chemotherapy. CT scan disclosed two liver metastases: one located between segments 7 and 8 and another one in segment 2. At liver examination, another metastasis was found on segment 3. We decided to perform a bisegmentectomy 7-8 along with bisegmentectomy 2-3 in a single procedure. The operation began with mobilization of the right liver with complete dissection of retrohepatic vena cava. Inferior right hepatic vein was absent. Right hepatic vein was dissected and encircled. Upper part of right liver, containing segment 7 and 8, was marked with cautery. Selective hemi-Pringle maneuver was performed and right hepatic vein was divided with stapler. At this point, liver rotation to the left allowed direct view and access to the superior aspect of the right liver. Liver transection was accomplished with harmonic scalpel and endoscopic stapling device. Bisegmentectomy 2-3 was performed using the intrahepatic Glissonian approach. The specimens were extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 240 minutes with no need for transfusion. Recovery was uneventful. Patient was discharged on the fifth postoperative day. Patient is well with no evidence of disease 14 months after liver resection. Tumor markers are within normal range. Bisegmentectomy 7-8 may increase resectability rate in patients with bilateral lesions. This operation can be performed safely by laparoscopy. Preservation of segments 5 and 6 permitted simultaneous resection of segments 2 and 3 with adequate liver remnant.
Resumo:
To test a mathematical model for measuring blinking kinematics. Spontaneous and reflex blinks of 23 healthy subjects were recorded with two different temporal resolutions. A magnetic search coil was used to record 77 blinks sampled at 200 Hz and 2 kHz in 13 subjects. A video system with low temporal resolution (30 Hz) was employed to register 60 blinks of 10 other subjects. The experimental data points were fitted with a model that assumes that the upper eyelid movement can be divided into two parts: an impulsive accelerated motion followed by a damped harmonic oscillation. All spontaneous and reflex blinks, including those recorded with low resolution, were well fitted by the model with a median coefficient of determination of 0.990. No significant difference was observed when the parameters of the blinks were estimated with the under-damped or critically damped solutions of the harmonic oscillator. On the other hand, the over-damped solution was not applicable to fit any movement. There was good agreement between the model and numerical estimation of the amplitude but not of maximum velocity. Spontaneous and reflex blinks can be mathematically described as consisting of two different phases. The down-phase is mainly an accelerated movement followed by a short time that represents the initial part of the damped harmonic oscillation. The latter is entirely responsible for the up-phase of the movement. Depending on the instantaneous characteristics of each movement, the under-damped or critically damped oscillation is better suited to describe the second phase of the blink. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
PURPOSE. To establish the relationship between upper eyelid saccades and upper eyelid pursuit movements. METHODS. Upper eyelid saccades and periodic sinusoidal upper eyelid pursuit movements were recorded in a sample of controls and patients with Graves upper eyelid retraction. A video-computerized system was used to register both types of movements that accompanied 60 of eye rotation across the upper and lower hemifields. The forced harmonic oscillator model was used to fit saccadic and pursuit movements. RESULTS. Mean mid-pupil eyelid distance for the Graves patients (6.6 +/- 1.1 mm) was significantly higher than for the controls (4.6 +/- 0.8 mm; t = 7.18; P < 0.00001). Despite the difference in the upper eyelid resting position, saccades and pursuit eyelid movements of both groups were extremely well fitted by underdamped solutions and steady forced solutions of the harmonic oscillator model, respectively. For the controls, the amplitude of the pursuit movements was well correlated with the upward and downward saccades. The amplitude of the eyelid movements of the Graves patients (saccades and pursuit) was significantly reduced compared with that of the controls. CONCLUSIONS. Saccadic and pursuit movements of the upper eyelid can be described by the harmonic oscillator model. In healthy subjects and Graves patients, the amplitude of pursuit lid movements is correlated to the saccade amplitude. Pursuit eyelid movements are more difficult to register than saccades, and their measurements do not allow clear separation of the relaxation and contraction properties of the upper eyelid retractors.