132 resultados para GROUP-4
Resumo:
Purpose: To compare the level of sedation of oral administration of diazepam or midazolam associated or not with clonidine and their effects on upper eyelid margin position, heart rate, arterial pressure, and oxygen saturation. Methods: Seventy consecutive healthy patients American Society of Anesthesiologists (ASA) grade I-II scheduled for lower eyelid blepharoplasty were randomized into 4 groups according to the oral sedative agent used (group 1, diazepam 10 mg; group 2, diazepam 10 mg plus clonidine 0.15 mg; group 3, midazolam 15 mg; group 4, midazolam plus clonidine 0.15 mg). For all patients, the midpupil-to-upper eyelid margin distance, the heart rate, systolic and diastolic blood pressure, and oxygen saturation were recorded before and 1 hour after the administration of oral medication. The level of sedation at the time of surgery was measured with the Michigan University scale. Results: The depth of sedation was significantly more pronounced with midazolam (median score = 2) than with diazepam (median score = 1). Clonidine slightly increased the level of sedation of both diazepam and midazolam. The diastolic arterial blood pressure drop with midazolam associated or not with clonidine was significantly greater than with diazepam. The mean upper eyelid margin position shift (-1.42 mm) verified when clonidine was associated with midazolam was also significantly greater than with diazepam. Discussion: Oral sedation with diazepam or midazolam associated or not with clonidine is safe for ASA grade I-II patients. The systemic effects of diazepam and midazolam were small and very similar. The sedation induced by midazolam was clearly greater than that induced by diazepam. However, this higher level of sedation was accompanied by a more important shift in upper eyelid margin position.
Resumo:
Vascular endothelial growth factor (VEGF) is relevant for normal pregnancy, and abnormalities in VEGF functions are associated with hypertensive disorders of pregnancy. Because there are few studies on how VEGF genetic polymorphisms affect susceptibility to pre-eclampsia (PE), and no studies on how they affect susceptibility to gestational hypertension (GH), we compared VEGF genotype and haplotype distributions in normotensive and hypertensive pregnancies. Genotypes and haplotypes for VEGF polymorphisms (C-2578A, G-1154A and G-634C) were determined in 303 pregnant women (108 healthy pregnant, HP; 101 with GH and 94 with PE). When white and non-white pregnant women were considered together, no significant differences were found in the distributions of VEGF genotypes or haplotypes (P > 0.05) in the three groups. However, with only white subjects, significant differences were found in genotypes distributions for two (C-2578A and G-634C) VEGF polymorphisms (both P < 0.05) between the HP and the PE groups. Importantly, the haplotype including the variants C-2578, G-1154 and C-634, which is associated with higher VEGF gene expression, was less common in the PE group compared with the HP group (4% versus 16%; P = 0.0047). However, we found no significant differences in VEGF haplotypes distributions when the HP and GH groups were compared (P > 0.05). These findings suggest a protective effect for the `C-2578, G-1154 and C-634` haplotype against the development of PE, but no major effects of VEGF gene variants on susceptibility to GH.
Resumo:
Cell therapy constitutes a possibility for improving nerve regeneration, increasing the success of nerve repair. We evaluate the use of mononuclear cells in the regeneration of the sciatic nerve after axotomy followed by end-to-end neurorrhaphy. Forty adult male Wistar rats (250300 g) were divided into four groups: (1) sham, (2) neurorrhaphy: the sciatic nerve was sectioned and repaired using epineural sutures, (3) culture medium: after the suture, received an injection of 10 mu L of culture medium into the nerve, and (4) mononuclear cell: after the suture, a concentration of 3 X 10(6) of mononuclear cell was injected in epineurium region. Mononuclear cells were obtained from the bone marrow aspirates and separated by Ficoll-Hypaque method. The histological analyses were performed at the 4th postoperative day. The sciatic functional index, histological, and morphometric analyzes were used to evaluate nerve regeneration at the 6th postoperative week. Six rats were used for immunohistochemical analysis on the 4th postoperative day. In the group 4, on the fourth day, the histological analysis demonstrated a more accelerated degenerative process and an increase of the neurotrophic factors was observed. In the 6th week, all the morphometric results of the group 4 were statistically better compared with groups 2 and 3. There was a statistically significant improvement in the sciatic functional index for group 4 compared with groups 2 and 3. Mononuclear cells stimulated nerve regeneration, most probably by speeding up the Wallerian degeneration process as well as stimulating the synthesis of neurotrophic factors. Microsc. Res. Tech. 74:355-363, 2011. (C) 2010 Wiley-Liss, Inc.
Resumo:
The purpose of this in vitro study was to compare the bond strength between fiber post and laser-treated root canals. Forty single-rooted bovine teeth were endodontically treated and randomly divided into four groups of equal size according to the root canal treatment: group 1 conventional treatment (without laser irradiation); group 2 Nd:YAG laser (1.5 W, 10 Hz, 100 mJ); group 3 Er,Cr:YSGG laser (0.75 W, 20 Hz); and group 4 Nd:YAG + Er,Cr:YSGG lasers. The fiber posts were cemented with an adhesive system + resin cement, in accordance with the manufacturer`s instructions. A mini acrylic pipe was fixed on the coronal section of the post using a light-polymerized resin. Specimens were mounted on an acrylic pipe with a self-polymerized resin. Retention forces were determined using a universal testing machine (0.5 mm/min). Data were analyzed using one-way ANOVA and Tukey tests (p < 0.05). The post retention force in group 2 was found to be lower than that in the other experimental groups. Fractures were observed at the interface between the dentin and the resin in all groups. High-intensity lasers can be used in conventional endodontic treatment; however, root canal surface irradiation using the Nd:YAG laser was shown to negatively affect the post retention force.
Resumo:
The objective of this study was to evaluate the influence of various pulse widths with different energy parameters of erbium:yttrium-aluminum-garnet (Er:YAG) laser (2.94 mu m) on the morphology and microleakage of cavities restored with composite resin. Identically sized class V cavities were prepared on the buccal surfaces of 54 bovine teeth by high-speed drill (n = 6, control, group 1) and prepared by Er:YAG laser (Fidelis 320A, Fotona, Slovenia) with irradiation parameters of 350 mJ/ 4 Hz or 400 mJ/2 Hz and pulse width: group 2, very short pulse (VSP); group 3, short pulse (SP); group 4, long pulse (LP); group 5, very long pulse (VLP). All cavities were filled with composite resin (Z-250-3 M), stored at 37A degrees C in distilled water, polished after 24 h, and thermally stressed (700 cycles/5-55A degrees C). The teeth were impermeabilized, immersed in 50% silver nitrate solution for 8 h, sectioned longitudinally, and exposed to Photoflood light for 10 min to reveal the stain. The leakage was evaluated under stereomicroscope by three different examiners, in a double-blind fashion, and scored (0-3). The results were analyzed by Kruskal-Wallis test (P > 0.05) and showed that there was no significant differences between the groups tested. Under scanning electron microscopy (SEM) the morphology of the cavities prepared by laser showed irregular enamel margins and dentin internal walls, and a more conservative pattern than that of conventional cavities. The different power settings and pulse widths of Er:YAG laser in cavity preparation had no influence on microleakage of composite resin restorations.
Resumo:
Purpose: The aim of this study was to quantitatively evaluate and qualitatively describe autogenous bone graft healing with or without an expanded polytetrafluoroethylene (e-PTFE) membrane in ovariectornized rats. Materials and Methods: Eighty Wistar rats, weighing approximately 300 g each, were used. A graft was obtained from the parietal bone and fixed to the sidewall of each animal`s left mandibular ramus. The animals were randomly divided into four experimental groups (n = 20 in each group): group 1, sham operated and autogenous bone graft only- group 2, sham operated and autogenous bone graft covered by e-PTFE membrane; group 3, ovariectornized (OVX) and autogenous bone graft only- group 4, OVX and autogenous bone graft covered by e-PTFE membrane. The animals were sacrificed at five different time points: immediately after grafting or at 7, 21, 45, or 60 days after grafting. Histologic examination and morphometric measurement of the sections were performed, and values were submitted to statistical analyses. Results: Both groups (sham and OVX) experienced loss of the original graft volume when it was not covered by the membrane, whereas use of the membrane resulted in additional bone formation beyond the edges of the graft and under the membrane. Histologic analysis showed integration of the grafts in all animals, although a larger number of marrow spaces was found in OVX groups. Conclusions: Association of bone graft with an e-PTFE membrane resulted in maintenance of its original volume as well as formation of new bone that filled the space under the membrane. Osteopenia did not influence bone graft repair, regardless of whether or not it was associated with e-PTFE membrane, but descriptive histologic analysis showed larger numbers of marrow spaces in the bone graft and receptor bed and formation of new bone in the OVX animals. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:1074-1082
Resumo:
Background: Low-fluoride dentifrices have been suggested as alternatives to reduce dental fluorosis risk, but there is no consensus regarding their clinical effectiveness, which has been suggested to be increased when their pH is acidic. Aims: This single-blind randomized clinical trial evaluated the caries increment during the use of a low-fluoride acidic liquid dentifrice. Methods: Four-year-old schoolchildren (n = 1,402) living in a fluoridated area (0.6-0.8 ppm F) were randomly allocated to 4 groups differing according to the type of dentifrice used over a 20-month period. Group 1 (n = 345): liquid dentifrice, 1,100 ppm F, pH 4.5. Group 2 (n = 343): liquid dentifrice, 1,100 ppm F, pH 7.0. Group 3 (n = 354): liquid dentifrice, 550 ppm F, pH 4.5. Group 4 (n = 360): toothpaste, 1,100 ppm F, pH 7.0. At baseline and after 20 months, clinical examinations were conducted (dmfs index) and caries increment was calculated. Data were analysed by GLM procedure using classrooms (cluster) as unit of analysis (p < 0.05). Results: The mean +/- SD (95% CI) net increments found were as follows. Group 1: 2.06 +/- 2.38 (1.8-2.3); group 2: 2.08 +/- 2.87 (1.7-2.4); group 3: 2.05 +/- 2.79 (1.7-2.4), and group 4: 2.08 +/- 2.34 (1.8-2.4). No significant differences were detected among the groups. Conclusion: In a population with high caries risk living in a fluoridated area, as the selected sample, and according to the present protocol, the low-fluoride acidic liquid dentifrice seems to lead to similar caries progression rates as conventional 1,100 ppm F toothpaste. Copyright (C) 2010 S. Karger AG, Basel
Resumo:
To evaluate the influence of dentifrice pH and fluoride (F) concentration on F uptake by plaque and nails, two sets of 5-to 6-year-old children were randomly allocated into four groups, according to the type of dentifrice they had been using for 1 year: (1) experimental liquid dentifrice (ELD), 1,100 ppm F, pH 7.0; (2) ELD, 1,100 ppm F, pH 4.5; (3) ELD, 550 ppm F, pH 4.5, and (4) commercial toothpaste, 1,100 ppm F, pH 7.0. In one set of children, nails were clipped. In the second, plaque samples were collected 1 h after the last use of dentifrice. F concentration in plaque and nails was analyzed. Plaque F concentration was significantly lower in group 4 than in groups 1-3. Nail F concentration was significantly higher in group 4, and significantly lower in group 3, than in group 1 or 2. Plaque F uptake was influenced significantly by dentifrice consistency and nonsignificantly by pH and F concentration. Reduction of dentifrice pH did not affect nail F concentration. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Objective. The aim of this study was to compare GPX instruments and hand files for gutta-percha removal. Study design. Fifty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 5 groups of 10 specimens each, according to the gutta-percha removal techniques: group 1: GPX (21-mm-long teeth); group 2: GPX and xylol as solvent (21-mm-long teeth); group 3: GPX (25-mm-long teeth); group 4: GPX and xylol as solvent (25-mm-long teeth); and group 5: hand files and xylol as solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken, and the teeth were grooved longitudinally and split. The area of residual debris was measured using Sigma Scan software. Results. The time for filling material removal was significantly shorter when GPX was used (P < .05). Overall, hand files and solvent produced fewer remnants of filling materials (P < .05). In the GPX 25 mm-long teeth group, the filling material was not removed in the apical third. Conclusions. Under the experimental conditions, the GPX instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments left a smaller amount of residual filling materials on the canal walls. The GPX instruments did not pull the gutta-percha beyond its tip. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 675-680)
Resumo:
Objective: The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the dentin/resin adhesive interface of lateral walls of occlusal restorations after thermocycling. Materials and Methods: Occlusal cavities were prepared in 60 human molars, divided into six groups: no liner (1 and 4); glass-ionomer cement (GIC, Ketac Molar Easymix, 3M ESPE) (2 and 5); and resin-modified glass-ionomer cement (RMGIC, Vitrebond, 3M ESPE) (3 and 6). Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adper Single Bond 2, 3M ESPE) that was mixed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. Specimens of groups 4, 5 and 6 were thermocycled (5 degrees C-55 degrees C) with a dwell time of 30 seconds for 5000 cycles. After this period, teeth were sectioned in approximately 0.8-mm slices. One slice of each tooth was randomly selected for confocal microscopy analysis. The other slices were sectioned into 0.8 nun x 0.8 mm beams, which were submitted to microtensile testing (MPa). Data were analyzed using two-way ANOVA and Tukey test (p < 0.05). Results: There was no detectedstatistical difference on bond strength among groups (alpha < 0.05). Confocal microscopy analysis showed a higher mean gap size in group 4(12.5 mu m) and a higher percentage of marginal gaps in the thermocycled groups. The RNIGIC liner groups showed the lowest percentage of marginal gaps. Conclusions: Lining with RMGIC resulted in less gap formation at the dentin/resin adhesive interface after artificial aging. RMGIC or GIC liners did not alter the microtensile bond strength of adhesive system/resin composite to dentin on the lateral walls of Class I restorations.
Resumo:
Objectives: To evaluate the bonding interface in experimentally weakened roots reinforced with adhesive restorative materials and quartz fibre posts, varying the light-exposure time of the composite resin used for root reinforcement. Methods: Twelve extracted human maxillary incisors teeth were used. The crowns were removed and the roots were endodontically treated. After post space preparation, the roots were assigned to four groups. The thickness of the root dentine was reduced and adhesively restored with composite resin light-activated through a translucent fibre post for either 40 s (group 1), 80 s (group 2) or 120 s (group 3). In the case of control (group 4), the roots were not weakened. One day after post cementation, the specimens were sectioned transversally in three slices and processed for scanning electron microscopic analysis to observe bonding interface formation, quality of the hybrid layer and density of resin tags using a four-step scale method. Results: Formation of a hybrid layer and resin tags were evident in all groups. There was no statistically (p > 0.05) significant difference between the regions analysed in each group (Friedman test) and between groups in each section depth (Kruskal-Wallis test). Furthermore, comparison of the flared/reinforced groups showed that the different time;; used for composite resin cure did not affect the results significantly (Kruskal-Wallis test, p = 0.2139). Conclusions: Different light-exposure times used for composite resin polymerisation during root canal reinforcement did not affect significantly the formation and quality of the dentine/adhesive/composite resin bonding interface. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P <= 0.05). Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased. To cite this article:Ricciardi Coppede A, de Mattos MdaGC, Rodrigues RCS, Ribeiro RF. Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study.Clin. Oral Impl. Res. 20, 2009; 624-632.doi: 10.1111/j.1600-0501.2008.01690.x.
Resumo:
Objective. The objective of this study was to evaluate in vivo the revascularization and the apical and periapical repair after endodontic treatment using 2 techniques for root canal disinfection (apical negative pressure irrigation versus apical positive pressure irrigation plus triantibiotic intracanal dressing) in immature dogs` teeth with apical periodontitis. Study design. Two test groups of canals with experimentally induced apical periodontitis were evaluated according to the disinfection technique: Group 1, apical negative pressure irrigation (EndoVac system), and Group 2, apical positive pressure irrigation (conventional irrigation) plus triantibiotic intracanal dressing. In Group 3 (positive control), periapical lesions were induced, but no endodontic treatment was done. Group 4 (negative control) was composed of sound teeth. The animals were killed after 90 days and the maxillas and mandibles were subjected to histological processing. The sections were stained with hematoxylin and eosin and Mallory Trichrome and examined under light microscopy. A description of the apical and periapical features was done and scores were attributed to the following histopathological parameters: newly formed mineralized apical tissue, periapical inflammatory infiltrate, apical periodontal ligament thickness, dentin resorption, and bone tissue resorption. Intergroup comparisons were done by the Kruskal-Wallis and Dunn`s tests (alpha = 0.05). Results. Although statistically significant difference was found only for the inflammatory infiltrate (P < .05), Group 1 presented more exuberant mineralized formations, more structured apical and periapical connective tissue, and a more advanced repair process than Group 2. Conclusion. From the histological observations, sodium hypochlorite irrigation with the EndoVac system can be considered as a promising disinfection protocol in immature teeth with apical periodontitis, suggesting that the use of intracanal antibiotics might not be necessary. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 779-787)
Resumo:
Objective. To evaluate the periapical repair after root canal treatment in the teeth of dogs using CT and conventional radiography and to compare these findings with the gold standard microscopic evaluation. Study design. The animals were divided into three groups according to endodontic treatment performed: Group 1, single-visit endodontic treatment in teeth without apical periodontitis; Group 2, single-visit endodontic treatment in teeth with apical periodontitis; and Group 3, endodontic treatment in teeth with apical periodontitis using calcium hydroxide as a root canal dressing. Group 4 consisted of teeth with apical periodontitis not submitted to root canal treatment and Group 5 consisted of healthy teeth without periapical disease. Radiographic, tomographic, and microscopic evaluations were performed by blind examiners. At 180 days experimental time, CT and radiographic measurements of periapical disease were compared with the gold standard microscopic measurement using intraclass correlation coefficient. Intergroup comparisons considering different methods of periapical lesions measurement or different clinical protocols of root canal treatment were performed by Kruskal Wallis test followed by Dunn. Integrity of lamina dura, presence of radiolucent areas, and presence of root resorption were analyzed by Fisher`s exact test. Results. There was discontinuity of the lamina dura and CPD in all teeth from Groups 2, 3, and 4 evaluated by tomography and radiography 45 days after CPD induction. Radiographically, 180 days after root canal treatment, there was no periapical lesion in teeth from Groups 1 and 3, different from groups 2 and 4 (p < .05). The highest reduction in the CPD size was observed on Group 3 (p < .05). According to the tomographic results, there was decrease of the size of the CPD on Group 3 but not on Groups 2 or 4. However, in all groups the periapical lesions presented larger mesio-distal extension if compared with radiography, both 45 days after CPD induction and 180 days after root canal treatment. At 180 days, CT measurements were closely related to microscopic results (ICC = 0.95) differently from radiographic evaluation (ICC = 0.86). Conclusion. CT Scan evaluation of periapical repair following root canal treatment provided similar information than that obtained by microscopic analysis, whereas radiographic evaluation underestimated the size do periapical lesion. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108:796-805)
Resumo:
The purpose of this study was to compare the favorable outcome of root canal treatment determined by periapical radiographs (PRs) and cone beam computed tomography (CBCT) scans. Ninety-six roots of dogs` teeth were used to form four groups (n = 24). In group 1, root canal treatments were performed in healthy teeth. Root canals in groups 2 through 4 were infected until apical periodontitis (AP) was radiographically confirmed. Roots with AP were treated by one-visit therapy in group 2, by two-visit therapy in group 3, and left untreated in group 4. The radiolucent area in the PRs and the volume of CBCT-scanned periapical lesions were measured before and 6 months after the treatment. In groups 1, 2, and 3, a favorable outcome (lesions absent or reduced) was shown in 57 (79%) roots using PRs but only in 25 (35%) roots using CBCT scans (p = 0.0001). Unfavorable outcomes occurred more frequently after one-visit therapy than two-visit therapy when determined by CBCT scans (p = 0.023). (J Endod 2009; 35:723-726)