90 resultados para Free fluids
Resumo:
Prussian Blue has been introduced as a mediator to achieve stable, sensitive, reproducible, and interference-free biosensors. However, Na(+), Li(+), H(+), and all group II cations are capable to block the activity of Prussian Blue and, because Na(+) can be found in most human fluids, Prussian Blue analogs have already been developed to overcome this problem. These analogs, such as copper hexacyanoferrate, have also been introduced in a conducting polypyrrole matrix to create hybrid materials (copper hexacyanoferrate/polypyrrole, CuHCNFe/Ppy) with improved mechanical and electrochemical characteristics. Nowadays, the challenges in amperometric enzymatic biosensors consist of improving the enzyme immobilization and in making the chemical signal transduction more efficient. The incorporation of nanostructured materials in biosensors can optimize both steps and a nanostructured hybrid CuHCNFe/Ppy mediator has been developed using a template of colloidal polystyrene particles. The nanostructured material has achieved sensitivities 7.6 times higher than the bulk film during H(2)O(2) detection and it has also presented better results in other analytical parameters such as time response and detection limit. Besides, the nanostructured mediator was successfully applied at glucose biosensing in electrolytes containing Prussian Blue blocking cations. (C) 2008 The Electrochemical Society.
Resumo:
We used morphological and molecular approaches to evaluate the diversity of free-living marine nematodes (order Enoplida) at four coastal sites in the Gulf of California and three on the Pacific coast of Baja California, Mexico. We identified 22 morphological species belonging to six families, of which Thoracostomopsidae and Oncholaimidae were the most diverse. The genus Mesacanthion (Thoracostomopsidae) was the most widespread and diverse. Five allopatric species, genetically and morphologically differentiated, were found in two localities in the Gulf of California (M. sp1 and M. sp2) and three in the Pacific coast (M. sp3, M. sp4 and M. sp5). Overall, we produced 19 and 20 sequences for the 18S and 28S genes, respectively. Neither gene displayed intraspecific polymorphisms, which allowed us to establish that some morphological variation was likely either ontogenetic or due to phenotypic plasticity. Although 18S and 28S phylogenies were topologically congruent (incongruence length difference test, P > 0.05), divergences between species were much higher in the 28S gene. Moreover, this gene possessed a stronger phylogenetic signal to resolve relationships involving Rhabdodemania and Bathylaimus. On the other hand, the close relationship of Pareurystomina (Enchilidiidae) with oncholaimids warrants further study. The 28S sequences (D2D3 domain) may be better suited for DNA barcoding of marine nematodes than those from the 18S rDNA, particularly for differentiating closely related or cryptic species. Finally, our results underline the relevance of adopting an integrative approach encompassing morphological and molecular analyses to improve the assessment of marine nematode diversity and advance their taxonomy.
Resumo:
A flow system designed with solenoid micro-pumps is proposed for fast and greener spectrophotometric determination of free glycerol in biodiesel. Glycerol was extracted from samples without using organic solvents. The determination involves glycerol oxidation by periodate, yielding formaldehyde followed by formation of the colored (3,5-diacetil-1,4-dihidrolutidine) product upon reaction with acetylacetone. The coefficient of variation, sampling rate and detection limit were estimated as 1.5% (20.0 mg L(-1) glycerol, n =10), 34 h(-1), and 1.0 mg L(-1) (99.7% confidence level), respectively. A linear response was observed from 5 to 50 mg L(-1), with reagent consumption estimated as 345 mu g of KIO(4) and 15 mg of acetylacetone per determination. The procedure was successfully applied to the analysis of biodiesel samples and the results agreed with the batch reference method at the 95% confidence level. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A green and highly sensitive analytical procedure was developed for the determination of free chlorine in natural waters, based on the reaction with N,N-diethyl-p-phenylenediamine (DPD). The flow system was designed with solenoid micro-pumps in order to improve mixing conditions by pulsed flows and to minimize reagent consumption as well as waste generation. A 100-cm optical path flow cell based on a liquid core waveguide was employed to increase sensitivity. A linear response was observed within the range 10.0 to 100.0 mu g L(-1), with the detection limit, coefficient of variation and sampling rate estimated as 6.8 mu g (99.7% confidence level), 0.9% (n = 20) and 60 determinations per hour, respectively. The consumption of the most toxic reagent (DPD) was reduced 20,000-fold and 30-fold in comparison to the batch method and flow injection with continuous reagent addition, respectively. The results for natural and tap water samples agreed with those obtained by the reference batch spectrophotometric procedure at the 95% confidence level. (C) 2010 Elsevier By. All rights reserved.
Resumo:
A new procedure for spectrofluorimetric determination of free and total glycerol in biodiesel samples is presented. It is based on the oxidation of glycerol by periodate, forming formaldehyde, which reacts with acetylacetone, producing the luminescent 3,5-diacetyl-1,4-dihydrolutidine. A flow system with solenoid micro-pumps is proposed for solution handling. Free glycerol was extracted off-line from biodiesel samples with water, and total glycerol was converted to free glycerol by saponification with sodium ethylate under sonication. For free glycerol, a linear response was observed from 5 to 70 mg L(-1) with a detection limit of 0.5 mg L(-1), which corresponds to 2 mg kg(-1) in biodiesel. The coefficient of variation was 0.9% (20 mg L(-1), n = 10). For total glycerol, samples were diluted on-line, and the linear response range was 25 to 300 mg L(-1). The detection limit was 1.4 mg L(-1) (2.8 mg kg(-1) in biodiesel) with a coefficient of variation of 1.4% (200 mg L(-1), n = 10). The sampling rate was ca. 35 samples h(-1) and the procedure was applied to determination of free and total glycerol in biodiesel samples from soybean, cottonseed, and castor beans.
Resumo:
Given a prime power q, define c (q) as the minimum cardinality of a subset H of F 3 q which satisfies the following property: every vector in this space di ff ers in at most 1 coordinate from a multiple of a vector in H. In this work, we introduce two extremal problems in combinatorial number theory aiming to discuss a known connection between the corresponding coverings and sum-free sets. Also, we provide several bounds on these maps which yield new classes of coverings, improving the previous upper bound on c (q)
Resumo:
In this paper we report findings on the presence of circadian rhythms in six species of cave-dwelling fishes from Brazil. Locomotor activity of islolated individuals was automatically recorded for 10 consecutive days under constant darkness. The species tested show varied degrees of specialization to subterranean life and we found varying degrees of the circadian components of locomotor activity as measured by the periodogram algorhythm of Lomb-Scargle. Both the presence and robustness of the circadian components seem to vary according to the degree of specialization to subterranean life, the more specialized, the less circadian rhythmicity was detected.
Resumo:
Background: Research on life expectancy has demonstrated the negative impact of disability on the health of older adults and its differential effects on women as evidenced by their higher disabled life expectancy (DLE). The goal of the present study was to investigate gender differences in total life expectancy (TLE), disability-free life expectancy (DFLE), and DLE; examine gender differences on personal care assistance among older adults in Sao Paulo, Brazil; and discuss the implications for public policies. Methods: The sample was drawn from two waves (2000, 2006) of the dataset of Salud, Bienestar, y Envejecimiento, a large longitudinal study conducted in Sao Paulo (n = 2,143). The study assessed disability using the activities of daily living (ADL). The interpolation of Markov Chain method was used to estimate gender differences in TLE, DLE, and DFLE. Findings: TLE at age 60 years was approximately 5 years longer for women than men. Women aged 60 years were expected to live 28% of their remaining lives twice the percentage for men with at least one ADL disability. These women also lived more years (M = 0.71, SE = 0.42) with three or more ADL disabilities than men (M = 0.82, SE = 0.16). In terms of personal care assistance, women received more years of assistance than men. Conclusion: Among older adults in Sao Paulo, women lived longer lives but experienced a higher and more severe disability burden than men. In addition, although women received more years of personal assistance than men, women experienced more unmet care assistance needs. Copyright (C) 2011 by the Jacobs Institute of Women`s Health. Published by Elsevier. Inc.
Resumo:
Objective: to identify risk factors associated with neonatal transfers from a free-standing birth centre to a hospital. Design: epidemiological case-control study. Setting: midwifery-led free-standing birth centre in Sao Paulo, Brazil. Participants: 96 newborns were selected from 2840 births between September 1998 and August 2005. Cases were defined as all new borns transferred from the birth centre to a hospital (n = 32), and controls were defined as new borns delivered at the same birth centre, during the same time period, and who had not been transferred to a hospital (n = 64). Measurements and findings: data were collected from medical records available at the birth centre. Univariate and multivariate analyses were performed using logistic regression. The multivariate analysis included outcomes with p<0.25, specifically: smoking during pregnancy, prenatal care appointments, labour complications, weight in relation to gestational age, and one-minute Apgar score. Of the foregoing outcomes, those that remained in the full regression model as a risk factor associated with neonatal transfer were: smoking during pregnancy [p = 0.009, odds ratio (OR) = 4.1,95% confidence interval (CI) 1.03-16.33], labour complications (p<0.001, OR = 5.5, 95% CI 1.06-28.26) and one-minute Apgar score <= 7 (p<0.001, OR = 7.8,95% CI 1.62-37.03). Key conclusions and implications for practice: smoking during pregnancy, labour complications and one-minute Apgar score <= 7 were confirmed as risk factors for neonatal transfer from the birth centre to a hospital. The identified risk factors can help to improve institutional protocols and formulate hypotheses for other studies. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Background Studies have shown that there is no safe level of secondhand smoke (SHS) exposure and there is a close link between SHS and the risk of coronary heart disease and stroke. Carbon monoxide (CO) is one of the most important components present in SHS. Objective To evaluate the impact of the smoking ban law in the city of Sao Paulo, Brazil, on the CO concentration in restaurants, bars, night clubs and similar venues and in their workers. Methods In the present study we measured CO concentration in 585 hospitality venues. CO concentration was measured in different environments (indoor, semi-open and open areas) from visited venues, as well as, in the exhaled air from approximately 627 workers of such venues. Measurements were performed twice, before and 12 weeks after the law implementation. In addition, the quality of the air in the city during the same period of our study was verified. Results The CO concentration pre-ban and pot-ban in hospitality venues was indoor area 4.57 (3.70) ppm vs 1.35 (1.66) ppm (p<0.0001); semi-open 3.79 (2.49) ppm vs 1.16 (1.14) ppm (p<0.0001); open area 3.31 (2.2) ppm vs 1.31 (1.39) ppm (p<0.0001); smoking employees 15.78 (9.76) ppm vs 11.50 (7.53) ppm (p<0.0001) and non-smoking employees 6.88 (5.32) ppm vs 3.50 (2.21) ppm (p<0.0001). The average CO concentration measured in the city was lower than 1 ppm during both pre-ban and post-ban periods. Conclusion Sao Paulos smoking-free legislation reduced significantly the CO concentration in hospitality venues and in their workers, whether they smoke or not.
Resumo:
High solids content film-forming poly[styrene-co-(n-butyl acrylate)] [poly(Sty-co-BuA)] latexes armored with Laponite clay platelets have been synthesized by soap-free emulsion copolymerization of styrene and n-butyl acrylate. The polymerizations were performed in batch in the presence of Laponite and a methyl ether acrylateterminated poly(ethylene glycol) macromonomer in order to promote polymer/clay association. The overall polymerization kinetics showed a pronounced effect of clay on nucleation and stabilization of the latex particles. Cryo-transmission electron microscopy observation confirmed the armored morphology and indicated that the majority of Laponite platelets were located at the particle surface. The resulting nanostructured films displayed enhanced mechanical properties.
Resumo:
This paper aims to formulate and investigate the application of various nonlinear H(infinity) control methods to a fiee-floating space manipulator subject to parametric uncertainties and external disturbances. From a tutorial perspective, a model-based approach and adaptive procedures based on linear parametrization, neural networks and fuzzy systems are covered by this work. A comparative study is conducted based on experimental implementations performed with an actual underactuated fixed-base planar manipulator which is, following the DEM concept, dynamically equivalent to a free-floating space manipulator. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
An accurate estimate of machining time is very important for predicting delivery time, manufacturing costs, and also to help production process planning. Most commercial CAM software systems estimate the machining time in milling operations simply by dividing the entire tool path length by the programmed feed rate. This time estimate differs drastically from the real process time because the feed rate is not always constant due to machine and computer numerical controlled (CNC) limitations. This study presents a practical mechanistic method for milling time estimation when machining free-form geometries. The method considers a variable called machine response time (MRT) which characterizes the real CNC machine`s capacity to move in high feed rates in free-form geometries. MRT is a global performance feature which can be obtained for any type of CNC machine configuration by carrying out a simple test. For validating the methodology, a workpiece was used to generate NC programs for five different types of CNC machines. A practical industrial case study was also carried out to validate the method. The results indicated that MRT, and consequently, the real machining time, depends on the CNC machine`s potential: furthermore, the greater MRT, the larger the difference between predicted milling time and real milling time. The proposed method achieved an error range from 0.3% to 12% of the real machining time, whereas the CAM estimation achieved from 211% to 1244% error. The MRT-based process is also suggested as an instrument for helping in machine tool benchmarking.
Resumo:
This paper presents results on a verification test of a Direct Numerical Simulation code of mixed high-order of accuracy using the method of manufactured solutions (MMS). This test is based on the formulation of an analytical solution for the Navier-Stokes equations modified by the addition of a source term. The present numerical code was aimed at simulating the temporal evolution of instability waves in a plane Poiseuille flow. The governing equations were solved in a vorticity-velocity formulation for a two-dimensional incompressible flow. The code employed two different numerical schemes. One used mixed high-order compact and non-compact finite-differences from fourth-order to sixth-order of accuracy. The other scheme used spectral methods instead of finite-difference methods for the streamwise direction, which was periodic. In the present test, particular attention was paid to the boundary conditions of the physical problem of interest. Indeed, the verification procedure using MMS can be more demanding than the often used comparison with Linear Stability Theory. That is particularly because in the latter test no attention is paid to the nonlinear terms. For the present verification test, it was possible to manufacture an analytical solution that reproduced some aspects of an instability wave in a nonlinear stage. Although the results of the verification by MMS for this mixed-order numerical scheme had to be interpreted with care, the test was very useful as it gave confidence that the code was free of programming errors. Copyright (C) 2009 John Wiley & Sons, Ltd.
Resumo:
This paper presents new experimental results of Vortex-Induced Vibration (VIV) on inclined cylinders. Models are mounted on a low damping air-bearing elastic base with one degree-of-freedom, constrained to oscillate only in the transverse direction to a free stream. The Reynolds number varied in the range 2000 less than or similar to Re less than or similar to 8000. New measurements on the dynamic response oscillations of inclined cylinders, due to VIV, are compared with previous experiments of a vertical cylinder. Models with circular and elliptical cross sections have been tested. The purpose of this work is to check the validity of the normal velocity correction of VIV studies of inclined structures. The results show that the reduced velocity range, in which the upper and lower branches of VIV occurs, is similar to the vertical cylinder case if the proper projected velocity is considered. Tests have been conducted to support this observation with inclinations up to 45 degrees. We have also observed that the amplitudes of oscillation of the inclined circular cylinder are comparable, but slightly lower than, to the amplitudes observed in the vertical cylinder experiments. Measured forces and added mass also show similar behaviour. However, for cases with an elliptical cylinder, the amplitudes of oscillation are considerably lower than those observed for a circular cylinder. This difference is explained by the higher added mass of the elliptical cylinder. (C) 2009 Elsevier Ltd. All rights reserved.