74 resultados para Exciton diffusion length


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment was carried out to evaluate the effect of different heating times of settable eggs of Cobb 500 (R) broiler breeders before submitting them to different storage periods on body weight, digestive tract organ weights, and intestinal mucosa morphology of newly-hatched chicks. Settable eggs were distributed in a completely randomized experimental design with a 3 x 3 factorial arrangement: pre-storage heating periods (0, 6, 12 hours at 36.92 degrees C) and storage periods (4, 9, 14 days at 12.06 degrees C). Body weight and relative weights of the yolk sac, heart, liver, proventriculus+gizzard, and intestinal segments were measured in chicks hatching at 480 and 498 hours of incubation. Villi height, width and perimeter, and crypt depth < im) were measured in duodenal histological sections. It was concluded that pre-storage healing for six hours of eggs stored for four or nine days increases small intestine weight of newly-hatched chicks, but does not influence the morphology of the duodenal mucosa. Pre-storage heating for 12 hours negatively influences body weight and duodenal mucosa development, and therefore this practice is not recommended. Storage length does not have consistent effect on body weight and development of the gastrointestinal tract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Restriction fragment length polymorphism (RFLP) is a common molecular assay used for genotyping, and it requires validated quality control procedures to prevent mistyping caused by impaired endonuclease activity. We have evaluated the usefulness of a plasmid-based internal control in RFLP assays. Results: Blood samples were collected from 102 individuals with acute myocardial infarction (AMI) and 108 non-AMI individuals (controls) for DNA extraction and laboratory analyses. The 1196C> T polymorphism in the toll-like receptor 4 (TLR4) gene was amplified by mismatched-polymerase chain reaction (PCR). Amplicons and pBluescript II SK-plasmid were simultaneously digested with endonuclease HincII. Fragments were separated on 2% agarose gels. Plasmid was completely digested using up to 55.2 nmL/L DNA solutions and 1 mu L PCR product. Nevertheless, plasmid DNA with 41.4 nM or higher concentrations was incompletely digested in the presence of 7 mL PCR product. In standardized conditions, TLR4 1196C> T variant was accurately genotyped. TLR4 1196T allele frequency was similar between AMI (3.1%) and controls (2.0%, p = 0.948). TLR4 SNP was not associated with AMI in this sample population. In conclusion, the plasmid-based control is a useful approach to prevent mistyping in RFLP assays, and it is validate for genetic association studies such as TLR4 1196C> T.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

WO(3)/chitosan and WO(3)/chitosan/poly(ethylene oxide) (PEO) films were prepared by the layer-by-layer method. The presence of chitosan enabled PEO to be carried into the self-assembled structure, contributing to an increase in the Li(+) diffusion rate. On the basis of the galvanostatic intermittent titration technique (GITT) and the quadratic logistic equation (QLE), a spectroelectrochemical method was used for determination of the ""optical"" diffusion coefficient (D(op)), enabling analysis of the Li(+) diffusion rate and, consequently, the coloration front rate in these host matrices. The D(op) values within the WO(3)/chitosan/PEO film were significantly higher than those within the WO(3)/chitosan film, mainly for higher values of injected charge. The presence of PEO also ensured larger accessibility to the electroactive sites, in accordance with the method employed here. Hence, this spectroelectrochemical method allowed us to separate the contribution of the diffusion process from the number of accessible electroactive sites in the materials, thereby aiding a better understanding of the useful electrochemical and electrochromic properties of these films for use in electrochromic devices. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. Toxic leukoencephalopathy may present acutely or subacutely with symmetrically reduced diffusion in the periventricular and supraventricular white matter, hereafter referred to as periventricular white matter. This entity may reverse both on imaging and clinically. However, a gathering together of the heterogeneous causes of this disorder as seen on MRI with diffusion-weighted imaging (DWI) and an analysis of their likelihood to reverse has not yet been performed. Our goals were to gather causes of acute or subacute toxic leukoencephalopathy that can present with reduced diffusion of periventricular white matter in order to promote recognition of this entity, to evaluate whether DWI with apparent diffusion coefficient (ADC) values can predict the extent of chronic FLAIR abnormality ( imaging reversibility), and to evaluate whether DWI can predict the clinical outcome ( clinical reversibility). MATERIALS AND METHODS. Two neuroradiologists retrospectively reviewed the MRI examinations of 39 patients with acute symptoms and reduced diffusion of periventricular white matter. The reviewers then scored the extent of abnormality on DWI and FLAIR. ADC ratios of affected white matter versus the unaffected periventricular white matter were obtained. Each patient`s clinical records were reviewed to determine the cause and clinical outcome. Histology findings were available in three patients. Correlations were calculated between the initial MRI markers and both the clinical course and the follow-up extent on FLAIR using Spearman`s correlation coefficient. RESULTS. Of the initial 39 patients, seven were excluded because of a nontoxic cause (hypoxic-ischemic encephalopathy [HIE] or congenital genetic disorders) or because of technical errors. In the remaining 32 patients, no correlation was noted between any of the initial MRI markers (percentage of ADC reduction, DWI extent, or FLAIR extent) with the clinical outcome. Three patients had histologic correlation. However, moderate correlation was seen between the extent of abnormality on initial FLAIR and the extent on follow-up FLAIR (r = 0.441, p = 0.047). Of the 13 patients who underwent repeat MRI at 21 days or longer, the reduced diffusion resolved in all but one. Significant differences were noted between ADC values in affected white matter versus unaffected periventricular white matter on initial (p < 0.0001) but not on follow-up MRI (p = 0.13), and in affected white matter on initial versus follow-up (p = 0.0014) in those individuals who underwent repeat imaging on the same magnet (n = 9), confirming resolution of the DWI abnormalities. CONCLUSION. Acute toxic leukoencephalopathy with reduced diffusion may be clinically reversible and radiologically reversible on DWI, and may also be reversible, but to a lesser degree, on FLAIR MRI. None of the imaging markers measured in this study appears to correlate with clinical outcome, which underscores the necessity for prompt recognition of this entity. Alerting the clinician to this potentially reversible syndrome can facilitate treatment and removal of the offending agent in the early stages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To compare cervical length (CL) at 18-21 and 22-25 weeks` gestation in twin pregnancies in prediction of spontaneous preterm delivery and to examine cervical shortening. Methods: Retrospective cohort study of CL measured at 18-21 and 22-25 weeks` gestation in twin pregnancies. Results: Receiver operating characteristics (ROC) curve revealed area of 0.64 (95% CI 0.53-0.75) and 0.80 (95% CI 0.72-0.88) for measurements at 18-21 and 22-25 weeks, respectively (P <= 0.001). Sensitivities of 33.3% and 23% and negative predicting value (NPV) of 97.3% and 86.8% for delivery at <28 and <34 weeks gestation were reached for measurements at 18-21 weeks. Sensitivities of 71.4% and 38.2% and NPV of 99.1% and 91.4% for delivery at <28 and <34 weeks` gestation were reached for measurements at 22-25 weeks. Cervical length shortening analysis showed an area under ROC curve of 0.81 (95% CI 0.73-0.89) and best cut-off was at >= 2 mm/week. Sensitivities of 80% and 60.8% and NPV of 98.9% and 90.6% for delivery at <28 and <34 weeks gestation were reached. Conclusions: In twin gestations, assessment of CL at 22-25 weeks is better than assessment at 18-21 weeks to predict preterm delivery before 34 weeks. Cervical shortening at a rate of >= 2 mm/weeks between 18 and 25 weeks gestation was a good predictor of spontaneous preterm birth in this high-risk population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The development of products and services for health care systems is one of the most important phenomena to have occurred in the field of health care over the last 50 years. It generates significant commercial, medical and social results. Although much has been done to understand how health technologies are adopted and regulated in developed countries, little attention has been paid to the situation in low- and middle-income countries (LMICs). Here we examine the institutional environment in which decisions are made regarding the adoption of expensive medical devices into the Brazilian health care system. Methods We used a case study strategy to address our research question. The empirical work relied on in-depth interviews (N = 16) with representatives of a wide range of actors and stakeholders that participate in the process of diffusion of CT (computerized tomography) scanners in Brazil, including manufacturers, health care organizations, medical specialty societies, health insurance companies, regulatory agencies and the Ministry of Health. Results The adoption of CT scanners is not determined by health policy makers or third-party payers of public and private sectors. Instead, decisions are primarily made by administrators of individual hospitals and clinics, strongly influenced by both physicians and sales representatives of the medical industry who act as change agents. Because this process is not properly regulated by public authorities, health care organizations are free to decide whether, when and how they will adopt a particular technology. Conclusions Our study identifies problems in how health care systems in LMICs adopt new, expensive medical technologies, and suggests that a set of innovative approaches and policy instruments are needed in order to balance the institutional and professional desire to practise a modern and expensive medicine in a context of health inequalities and basic health needs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To evaluate the role of hormonal contraceptives as a risk factor of high-risk human papillomavirus (HR-HPV), cervical intraepithelial lesions (CIN) and cervical cancer in our multi-center population-based LAMS (Latin American Screening) study. Methods: A cohort study with >12,000 women from Brazil and Argentina using logistic regression to analyze the covariates of hormonal contraception (HOC - oral, injections, patches, implants, vaginal ring and progesterone intrauterine system) use followed by multivariate modeling for predictors of HR-HPV and CIN2+. Results: HR-HPV infection was a consistent risk factor of high-grade CIN in all three groups of women. The length of HOC use was not significantly related to high-grade squamous intraepithelial lesions (HSIL)+ Pap (p = 0.069), LSIL+ Pap (p = 0.781) or ASCUS+ (p = 0.231). The same was true with the length of HOC use and histology CIN3+ (p = 0.115) and CIN2+ (p = 0.515). Frequently, HOC users have previously shown more HPV-related lesions, as well as lower HPV prevalence if they were current smokers. But HOC use and time of usage were not independent risk factors of either HR-HPV infection or high-grade CIN using multiple logistic regressions. Conclusions: No evidence was found for an association between the use of HOC with an increased risk for HR-HPV infection or high-grade CIN in this cohort. Copyright (C) 2010 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective(s): We intend to verify if fetal volume and crown-rump length were different between singletons and twins in pregnancies aged from 7 to 10 weeks and to evaluate if fetal volume is more accurate to determine the gestational age than crown-rump length at this gestational age. Study design: From 52 days (7 weeks and 3 days) to 73 days (10 weeks and 3 days) weekly three-dimensional Ultrasonography was per-formed in 20 twin fetuses and 20 singletons. Crown-rump length and fetal volume using VOCAL were assessed in all examinations. The `true` gestational age was based on oocyte retrieval. Results: At the age of 52 days, the crown-rump length was 11.74 +/- 0.27 mm (mean +/- S.D.) and 11.48 +/- 0.22 mm (singletons and twins, respectively), while the fetal volume was 0.354 +/- 0.015 cm(3) and 0.324 +/- 0.012 cm(3). At the gestational age of 73 days, the crown-rump length was 36.19 +/- 0.90 mm and 35.87 +/- 0.54 mm and the fetal volume was 6.204 +/- 0.090 cm(3) and 6.083 +/- 0.081 cm(3). The total relative increase observed was much higher for fetal volume than for CRL: 1705 +/- 301% vs. 210 +/- 33% in singletons and 1827 +/- 305% vs. 214 +/- 25% in twins. The 95% limits of agreement (+/- 2.3 days vs. +/- 3.2 days, fetal volume vs. crown-rump length) and the intraclass correlation coefficients (0.989 vs. 0.978) between the ""true"" gestational age and that predicted by fetal volume were better than those predicted by crown-rump length. No significant difference was identified between singletons and twins for both fetal volume and crown-rump length. Conclusion(s): Twins and singletons had similar fetal volume and crown-rump length between the 7th and 10th week of gestational age. Additionally, fetal volume assessed by VOCAL was better than crown-rump length to estimate the gestational age at the evaluated period. However, the improvement was small and probably without clinical significance. Condensation: Fetal volume and crown-rump length were similar between singletons and twins. Fetal volume relative increase was higher and the predicted gestational age was better. (c) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the crown-rump length (CRL) and the fetal head and trunk (HT) volume between singletons and twins conceived after in vitro fertilization. Thirty pregnant patients submitted to embryo transfer were enrolled in this research. Ten conceived twins (20 dichorionic fetuses) while other 20 conceived singletons. The gestational age was calculated by adding 14 d to the number of days between the oocyte retrieval and the scheduled ultrasound. Three-dimensional ultrasound scans were performed weekly from 73 d (10 wk and 3 d) to 101 d (14 wk and 3 d) of gestational age. HT volume was assessed by VOCAL using 15 degrees step rotation on the manual mode. The measurement of CRL was performed by using the longitudinal plane of the fetus in the multiplanar view. The CRL and HT volume weekly relative increase were evaluated to compare the growth between singletons and twins. No significant difference was identified, in any analyzed week, when comparing the mean of CRL and HT volume between singletons and twins. Additionally, no significant difference between singletons and twins was noticed when comparing the weekly relative increase, both for CRL and HT volume. However, the weekly relative increase was significantly higher for HT volume than for CRL in every week studied for both singletons and twins. The total relative increase observed between 73 and 101 d was much higher for HT volume than for CRL: 679 +/- 39% versus 138 +/- 18% in singletons and 689 +/- 58% versus 139 +/- 21% in twins (HT volume and CRL, respectively), suggesting that HT volume could more accurately determine the gestational age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Histopathological alterations in human aneurysms and dissections of the thoracic ascending aorta include areas of mucoid degeneration within the medial layer, colocalized with areas of cell disappearance and disruption of extracellular matrix elastic and collagen fibers. We studied the presence of matrix metalloproteinases in relation to their capacity to diffuse through the tissue or to be retained in areas of mucoid degeneration in aneurysms and dissections of the ascending aorta. Ascending aortas from 9 controls, 33 patients with aneurysms, and 14 with acute dissections, all collected at surgery, were analyzed. The morphological aspect was similar whatever the etiology or phenotypic expression of the pathological aortas, involving areas of extracellular matrix breakdown and cell rarefaction associated with mucoid degeneration. Release of proMMP-2, constitutively expressed by smooth muscle cells, was not different between controls and aneurysmal aortas, whereas the aneurysmal aortas released more of the active form. Release of pro and active MMP-9 was also similar between controls and aneurysmal aortas. Immunohistochemical staining of MMP-2 and MMP-9 was weak in both control and pathological aortas. In contrast, released MMP-7 (matrilysin) and MMP-3 (stromelysin-1) could not be detected in conditioned media but were present in tissue extracts with no detectable quantitative difference between controls and pathological aortas. Immunohistochemical staining of MMP-7 and MMP-3 revealed their retention in areas of mucoid degeneration, and semiquantitative evaluation of immunostaining showed more MMP-7 in pathological aortas than in controls. In conclusion, areas of mucoid degeneration, the hallmark of aneurysms, and dissections of thoracic ascending aortas, whatever their etiology, are not inert and can retain specific proteases. (c) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One hundred and fifty-one Erysipelothrix spp. isolates from diseased and carrier swine from Brazil were identified by PCR, submitted to serotyping and analyzed by amplified fragment length polymorphism with a single enzyme (AFLP). Reference strains from Australia and the United Kingdom were also examined. The 151 strains were classified into 18 different serotypes (1a, 1b, 2a, 2b, 4, 5, 6, 7, 8, 10, 11, 12, 15, 17, 19, 21, 24 and 25), being serotype 2b the most frequent (39.7%). By associating serotyping and PCR results, it was possible to identify 146 strains as E. rhusiopathiae and five strains as E. tonsillarum. Despite the fact that for this genus AFLP did not cluster all isolates according to serotype, origin, disease or isolation data, the execution of the technique was easy and fast, demonstrating high discriminatory power. The results produced by the AFLP analysis of Erysipelothrix spp. could also support its use as a discriminatory tool for E. rhusiopathiae and E. tonsillarum species. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At the end of 2002 and throughout 2003, there was a severe outbreak of infectious laryngotracheitis (ILT) in an intensive production area of commercial hens in the Sao Paulo State of Brazil. ILT virus was isolated from 28 flocks, and 21 isolates were genotyped by polymerase chain reaction and restriction fragment length polymorphism (PCR-RFLP) using four genes and eight restriction enzymes, and by partial sequencing of the infected cell protein 4 (ICP4) and thymidine kinase (TK) genes. Three groups resulted from the combinations of PCR-RFLP patterns: 19 field isolates formed Group I, and the remaining two isolates together with the chicken embryo origin (CEO) vaccine strains formed Group II. Group III comprised the tissue-culture origin (TCO) vaccine strain by itself. The PCR-RFLP results agreed with the sequencing results of two ICP4 gene fragments. The ICP4 gene sequence analysis showed that the 19 field isolates classified into Group I by RFLP-PCR were identical among themselves, but were different to the TCO and CEO vaccines. The two Group II isolates could not be distinguished from one of the CEO vaccines. The nucleotide and amino acid sequence analyses discriminated between the Brazilian and non-Brazilian isolates, as well as between the TCO and CEO vaccines. Sequence analysis of the TK gene enabled classification of the field isolates (Group I) as virulent and non-vaccine. This work shows that the severe ILT outbreak was caused by a highly virulent, non-vaccine strain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)