78 resultados para Echocardiography, Doppler, Color


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study design: This is cross-sectional study. Objectives: The aim of this study is to investigate the cardiac structure and function of subjects with spinal cord injury (SCI) and the impact of metabolic, hemodynamic and inflammatory factors on these parameters. Setting: Sao Paulo, Brazil. Methods: Sixty-five nondiabetic, nonhypertensive, sedentary, nonsmoker men (34 with SCI and 31 healthy subjects) were evaluated by medical history, anthropometry, laboratory tests, analysis of hemodynamic and inflammatory parameters and echocardiography. Results: Subjects with SCI had lower systolic blood pressure and higher levels of C-reactive protein and tumor necrosis factor receptors than the healthy ones. Echocardiography data showed that the SCI group presented similar left ventricular (LV) structural and systolic parameters, but lower initial diastolic velocity (Em) (9.2 +/- 0.5 vs 12.3 +/- 0.5 cm s(-1); P<0.001) and higher peak early inflow velocity (E)/Em ratio (7.7 +/- 0.5 vs 6.1 +/- 0.3; P = 0.009) compared with the able-bodied group, even after adjustment for systolic blood pressure and C-reactive protein levels. Furthermore, injured subjects with E/Em >8 had lower peak spectral longitudinal contraction (Sm) (9.0 +/- 0.7 vs 11.6 +/- 0.4cm s(-1); P<0.001) and cardiac output (4.2 +/- 0.2 vs 5.0 +/- 0.21 min(-1); P = 0.029), as well as higher relative wall thickness (0.38 +/- 0.01 vs 0.35 +/- 0.01; P = 0.005), than individuals with SCI with E/Em<8, but similar age, body mass index, blood pressure, injury level, metabolic parameters and inflammatory marker levels. Conclusion: Subjects with SCI presented impaired LV diastolic function in comparison with able-bodied ones. Moreover, worse LV diastolic function was associated with a pattern of LV concentric remodeling and subclinical decreases in systolic function among injured subjects. Overall, these findings might contribute to explain the increased cardiovascular risk reported for individuals with SCI. Spinal Cord (2011) 49, 65-69; doi: 10.1038/sc.2010.88; published online 27 July 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Template matching is a technique widely used for finding patterns in digital images. A good template matching should be able to detect template instances that have undergone geometric transformations. In this paper, we proposed a grayscale template matching algorithm named Ciratefi, invariant to rotation, scale, translation, brightness and contrast and its extension to color images. We introduce CSSIM (color structural similarity) for comparing the similarity of two color image patches and use it in our algorithm. We also describe a scheme to determine automatically the appropriate parameters of our algorithm and use pyramidal structure to improve the scale invariance. We conducted several experiments to compare grayscale and color Ciratefis with SIFT, C-color-SIFT and EasyMatch algorithms in many different situations. The results attest that grayscale and color Ciratefis are more accurate than the compared algorithms and that color-Ciratefi outperforms grayscale Ciratefi most of the time. However, Ciratefi is slower than the other algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Epidemiological studies have shown that beer has positive effects on inhibiting atherosclerosis, decreasing the content of serum low-density lipoprotein cholesterol and triglycerides, by acting as in vivo free radical scavenger. In this research, the antioxidant activity of commercial Brazilian beers (n = 29) was determined by the oxygen radical absorbance capacity (ORAC) and 1,1 -diphenyl-2-picrylhydrazyl (DPPH(center dot)) assays and results were analyzed by chemometrics. RESULTS: The brown ale samples (n = 11) presented higher (P < 0.05) flavonoids (124.01 mg L(-1)), total phenolics (362.22 mg L(-1)), non-flavonoid phenolics (238.21 mg L(-1)), lightness (69.48), redness (35.75), yellowness (55.71), color intensity (66.86), hue angle (59.14), color saturation (0.9620), DPPH(center dot) values (30.96% inhibition), and ORAC values (3,659.36 mu mol Trolox equivalents L(-1)), compared to lager samples (n = 18). Brown ale beers presented higher antioxidant properties (P < 0.05) measured by ORAC (1.93 times higher) and DPPH (1.65 times higher) compared to lager beer. ORAC values correlated well with the content of flavonoids (r = 0.47; P = 0.01), total phenolic compounds (r = 0.44; P < 0.01) and DPPH (r = 0.67; P < 0.01). DPPH values also correlated well to the content of flavonoids (r = 0.69; P < 0.01), total phenolic compounds (r = 0.60; P < 0.01), and non-flavonoid compounds (r = 0.46; P = 0.01). CONCLUSION: The results suggest that brown ale beers, and less significantly lager beers, could be sources of bioactive compounds with suitable free radical scavenging properties. (C) 2010 Society of Chemical Industry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the impact of systematic use of intraoperative Doppler ultrasound during microsurgical subinguinal varicocele repair. Design: Prospective clinical study. Setting: Andrology laboratory and male infertility section of the urology department of a tertiary care hospital. Patient(s): Two hundred and thirteen men with clinical varicocele. Intervention(s): Subinguinal microsurgical varicocele ligation using an intraoperative vascular Doppler flow detector. Main Outcome Measure(s): Number of veins ligated, lymphatic spared, arteries identified or accidentally ligated. Result(s): A statistically significant greater number of arteries were identified and preserved when intraoperative vascular Doppler was used. In addition, the average number of internal spermatic veins ligated was statistically significantly greater in the same group. Accidental artery ligation occurred in two cases (1.1%) in which the Doppler was not applied. There was no statistically significant difference in number of lymphatics spared between groups. Conclusion(s): Our findings showed that concomitant use of intraoperative vascular Doppler during microsurgical varicocelectomy allows more arterial branches to be preserved, and more internal spermatic veins are likely to be ligated. This device should be considered an attractive tool to improve surgical outcomes and safety. (Fertil Steril (R) 2010; 93: 2396-9. (C)2010 by American Society for Reproductive Medicine.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to determine the correlation between ductus venosus (DV) Doppler velocimetry and fetal cardiac troponin T (cTnT). Study design: Between March 2007 and March 2008, 89 high-risk pregnancies were prospectively studied. All patients delivered by cesarean section and the Doppler exams were performed on the same day. Multiple regression included the following variables: maternial age, parity, hypertension, diabetes, gestational age at delivery, umbilical artery (UA) S/D ratio, diagnosis of absent or reversed end-diastolic flow velocity (AREDV) in the UA, middle cerebral artery (MCA) pulsatility index (131), and DV pulsatility index for veins (PIV). Immediately after delivery, UA blood samples were obtained for the measurement of pH and cTnT levels. Statistical analysis included the Kruskal-Wallis test and multiple regressions. Results: The results showed a cTnT concentration at birth >0.05 ng/ml in nine (81.8%) of AREDV cases, a proportion significantly higher than that observed in normal UA S/D ratio and UA S/D ratio >p95 with positive diastolic blood flow (7.7 and 23.1%, respectively, p < 0.001). A positive correlation Was found between abnormal DV-PIV and elevated cTnT levels in the UA. Multiple regression identified DV-PIV and a diagnosis of AREDV as independent factors associated with abnormal fetal cTnT levels (p < 0.0001, F(2.86) = 63.5, R = 0.7722). Conclusion: DV-PIV was significantly correlated with fetal cTnT concentrations at delivery. AREDV and abnormal DV flow represent severe cardiac compromise, with increased systemic venous pressure, and a rise in right ventricular afterload, demonstrated by myocardial damage and elevated fetal cTnT. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiofirequency ablation of the pulmonary veins has been used to treat patients with paroxysmal atrial fibrillation (AF), and atrial damage after ablation is an issue of concern. To evaluate left atrial function shortly and midterm after ablation, 33 consecutive patients with paroxysmal AF were studied at baseline, 24 hours, and >= 6 months after ablation. Patients in sinus rhythm with normal ventricular function were included in the study. Echocardiographic measurements of left atrial volumes (Simpson`s rule) and transmitral and tissue Doppler myocardial (A`) velocities at the septal and lateral mitral annulus were undertaken at each time. Left atrial emptying fraction (EF; maximal - minimal left atrial volume/maximal left atrial volume) was used to express left atrial function. After 8 +/- 2 months, 30 of 33 patients returned (23 men, age 53 +/- 13 years), and all except 2 were in sinus rhythm. Shortly after ablation, left atrial minimal volumes increased (from 30 +/- 15 to 35 +/- 15 ml; p = 0.02), with maximal volumes unchanged, resulting in decreased left atrial EF (from 47 +/- 8 to 40 +/- 7 ml; p <0.05). Tissue Doppler septal A` velocities also decreased (from 8.2 +/- 1.8 to 6.9 +/- 2.0 cm/s; p <0.05). However, after midterm follow-up, both left atrial EF and septal A` velocities had slightly increased compared with shortly after ablation, although left atrial volumes remained similar to baseline. Septal A` velocity changes paralleled left atrial EF both shortly (r = 0.46, p = 0.02) and at midterm after ablation (r = 0.47, p = 0.01). In conclusion, after radiofrequency ablation, patients with paroxysmal AF experienced an initial impairment in atrial function, with improvement at longer term follow-up. (C) 2009 Elsevier Inc. All rights reserved. (Am J Cardiol 2009;103: 395-398)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although a new protocol of dobutamine stress echocardiography with the early injection of atropine (EA-DSE) has been demonstrated to be useful in reducing adverse effects and increasing the number of effective tests and to have similar accuracy for detecting coronary artery disease (CAD) compared with conventional protocols, no data exist regarding its ability to predict long-term events. The aim of this study was to determine the prognostic value of EA-DSE and the effects of the long-term use of beta blockers on it. A retrospective evaluation of 844 patients who underwent EA-DSE for known or suspected CAD was performed; 309 (37%) were receiving beta blockers. During a median follow-up period of 24 months, 102 events (12%) occurred. On univariate analysis, predictors of events were the ejection fraction (p <0.001), male gender (p <0.001), previous myocardial infarction (p <0.001), angiotensin-converting enzyme inhibitor therapy (p = 0.021), calcium channel blocker therapy (p = 0.034), and abnormal results on EA-DSE (p <0.001). On multivariate analysis, the independent predictors of events were male gender (relative risk [RR] 1.78, 95% confidence interval [CI] 1.13 to 2.81, p = 0.013) and abnormal results on EA-DSE (RR 4.45, 95% CI 2.84 to 7.01, p <0.0001). Normal results on EA-DSE with P blockers were associated with a nonsignificant higher incidence of events than normal results on EA-DSE without beta blockers (RR 1.29, 95% CI 0.58 to 2.87, p = 0.54). Abnormal results on EA-DSE with beta blockers had an RR of 4.97 (95% CI 2.79 to 8.87, p <0.001) compared with normal results, while abnormal results on EA-DSE without beta blockers had an RR of 5.96 (95% CI 3.41 to 10.44, p <0.001) for events, with no difference between groups (p = 0.36). In conclusion, the detection of fixed or inducible wall motion abnormalities during EA-DSE was an independent predictor of long-term events in patients with known or suspected CAD. The prognostic value of EA-DSE was not affected by the long-term use of beta blockers. (C) 2008 Elsevier Inc. All rights reserved. (Am J Cardiol 2008;102:1291-1295)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real time three-dimensional echocardiography (RT3DE) has been demonstrated to be an accurate technique to quantify left ventricular (LV) volumes and function in different patient populations. We sought to determine the value of RT3DE for evaluating patients with hypertrophic cardiomyopathy (HCM), in comparison with cardiac magnetic resonance imaging (MRI). Methods: We studied 20 consecutive patients with HCM who underwent two-dimensional echocardiography (2DE), RT3DE, and MRI. Parameters analyzed by echocardiography and MRI included: wall thickness, LV volumes, ejection fraction (LVEF), mass, geometric index, and dyssynchrony index. Statistical analysis was performed by Lin agreement coefficient, Pearson linear correlation and Bland-Altman model. Results: There was excellent agreement between 2DE and RT3DE (Rc = 0.92), 2DE and MRI (Rc = 0.85), and RT3DE and MRI (Rc = 0.90) for linear measurements. Agreement indexes for LV end-diastolic and end-systolic volumes were Rc = 0.91 and Rc = 0.91 between 2DE and RT3DE, Rc = 0.94 and Rc = 0.95 between RT3DE and MRI, and Rc = 0.89 and Rc = 0.88 between 2DE and MRI, respectively. Satisfactory agreement was observed between 2DE and RT3DE (Rc = 0.75), RT3DE and MRI (Rc = 0.83), and 2DE and MRI (Rc = 0.73) for determining LVEF, with a mild underestimation of LVEF by 2DE, and smaller variability between RT3DE and MRI. Regarding LV mass, excellent agreement was observed between RT3DE and MRI (Rc = 0.96), with bias of -6.3 g (limits of concordance = 42.22 to -54.73 g). Conclusion: In patients with HCM, RT3DE demonstrated superior performance than 2DE for the evaluation of myocardial hypertrophy, LV volumes, LVEF, and LV mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contrast echocardiography has been demonstrated useful for left ventricular opacification and improvement of endocardial border delineation. Another important clinical application of this technique refers to the better characterization of cardiac tumors and masses. We here described an asymptomatic patient with cystic mass attached to submitral valve apparatus in which contrast echocardiography was performed after intravenous injection of lipid-encapsulated microbubbles. It resulted in enhancement of the cystic borders and allowed for better definition of its diagnosis. Multislice computed tomography confirmed the echocardiographic findings. This case illustrates the potential of contrast echocardiography to improve the anatomic evaluation of cardiac masses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Two-dimensional (2-D) echocardiography is an excellent alternative method to perform endomyocardial biopsies (EB) in special situations, mainly when the patient is in a critical state and cannot go to the catheterization laboratory or when there are contraindications to the use of fluoroscopy as in the pregnancy. Objective. This single-center experience analyzed the last 25 years use of an EB technique guided by echocardiography realized at the bedside on critical patients. Methods. From 1985 to 2010, we performed 76 EB guided by 2-D echocardiography on 59 patients, among whom 38 (64.4%) were critically ill with examinations at the bedside; among 10 (16.9%) subjects, the procedure was carried out simultaneously with fluoroscopy for safety`s sake during the learning period. In addition, 8 (13.6%) were unavailable for fluoroscopy, and 3 (5.1%) required a hybrid method due to an intracardiac tumor. Results. The main adverse effects included local pain (n = 4, 5.6%); difficult out successful puncture due to previous biopsies (n = 4, 5.6%); local hematoma without major consequences (n = 3, 4.2%); failed but ultimately successful puncture on the first try due to previous biopsies or (n = 3, 4.2%); obesity and immediate postoperative period with impossibility to pass the bioptome into the right ventricle; however 2 days later the procedure was repeated successfully by echocardiography (n = 1, 1.4%). All myocardial specimens displayed suitable size. There were no undesirable extraction effects on the tricuspid valve tissue. In this series, there was no case of death, hemopericardium, or other major complication as a direct consequence of the biopsy. Conclusion. 2-D echocardiography is a special feature to guide EB is mainly in critically ill patients because it can be performed at the bedside without additional risk or disadvantages of fluoroscopy. The hybrid method associating 2-D echocardiography and fluoroscopy allows the procedure in different situations such as intracardiac tumor cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objectives: Cardiac positioning and stabilization during myocardial revascularization without extracorporeal circulation (ECC) may cause hemodynamic changes dependent to the surgical site. The objective of this study was to evaluate these changes during distal coronary anastomosis. Methods: Twenty adult patients undergoing myocardial revascularization without ECC were monitored by pulmonary artery catheter and transesophageal Echo Doppler. Hemodynamic data were collected at the following times before removing the stabilizer wall: (1) after volume adjustments, (2) at the beginning of distal anastomosis, and (3) after 5 minutes. Treated coronary arteries were grouped according to their location in the lateral, anterior, or posterior wall. Two-way ANOVA with repetition and Newman-Keuls post-test were used in the analysis. A p value < 0.05 was considered statically significant. Results: During myocardial revascularization without ECC, pulmonary artery wedge pressure showed elevation from 17.7 +/- 6.1 to 19.2 +/- 6.5 (p < 0.001) and 19.4 +/- 5.9 mmHg (p < 0.001), while the central venous pressure went from 13.9 +/- 5.4 to 14.9 +/- 5.9 mmHg (p = 0.007) and 15.1 +/- 6.0 mmHg (p = 0.006). Intermittent cardiac output was reduced from 4.70 +/- 1.43 to 4.23 +/- 1.22 (p < 0.001) and 4.26 +/- 1.25 L.min(-1) (p < 0.001). According to transesophageal Doppler, a significant group-time interaction was observed in cardiac output, which was reduced in the lateral group from 4.08 +/- 1.99 to 2.84 +/- 1.82 (p = 0.02) and 2.86 +/- 1.73 L.min(-1) (p = 0.02), and aortic blood flow, which went from 2.85 +/- 1.39 to 1.99 +/- 1.26 (p = 0.02) and 2.00 +/- 1.21 L.min(-1) (p = 0.02). Other hemodynamic changes were not observed during anastomoses. Conclusions: A significant hemodynamic deterioration was observed during myocardial revascularization without ECC. Transesophageal Doppler detected a decrease in cardiac output only in the lateral group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Real time myocardial contrast echocardiography (RTMCE) is an emerging imaging modality for assessing myocardial perfusion that allows for noninvasive quantification of regional myocardial blood flow (MBF). Aim: We sought to assess the value of qualitative analysis of myocardial perfusion and quantitative assessment of myocardial blood flow (MBF) by RTMCE for predicting regional function recovery in patients with ischemic heart disease who underwent coronary artery bypass grafting (CABG). Methods: Twenty-four patients with coronary disease and left ventricular systolic dysfunction (ejection fraction < 45%) underwent RTMCE before and 3 months after CABG. RTMCE was performed using continuous intravenous infusion of commercially available contrast agent with low mechanical index power modulation imaging. Viability was defined by qualitative assessment of myocardial perfusion as homogenous opacification at rest in >= 2 segments of anterior or >= 1 segment of posterior territory. Viability by quantitative assessment of MBF was determined by receiver-operating characteristics curve analysis. Results: Regional function recovery was observed in 74% of territories considered viable by qualitative analysis of myocardial perfusion and 40% of nonviable (P = 0.03). Sensitivity, specificity, positive and negative predictive values of qualitative RTMCE for detecting regional function recovery were 74%, 60%, 77%, and 56%, respectively. Cutoff value of MBF for predicting regional function recovery was 1.76 (AUC = 0.77; 95% CI = 0.62-0.92). MBF obtained by RTMCE had sensitivity of 91%, specificity of 50%, positive predictive value of 75%, and negative predictive value of 78%. Conclusion: Qualitative and quantitative RTMCE provide good accuracy for predicting regional function recovery after CABG. Determination of MBF increases the sensitivity for detecting hibernating myocardium. (Echocardiography 2011;28:342-349).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim of this study was to evaluate the degree of tricuspid valve insufficiency after orthotopic cardiac transplantation with bicaval anastomosis and prophylactic donor heart annuloplasty. Methods: At present, our cardiac transplantation experience includes 478 cases. After January 2002, we included 30 consecutive patients in this study who had undergone orthotopic cardiac transplantation and survived >6 months. The patients were divided into 2 groups: group I, 15 patients who underwent transplantation with prophylactic tricuspid annuloplasty on the donor heart with the De Vega technique; and group II, 15 patients who underwent transplantation without this procedure. Their preoperative clinical characteristics were the same. During the late postoperative follow-up, the degree of tricuspid insufficiency was evaluated by transthoracic Doppler echocardiography and assessed according to the Simpson scale: 0, absent; 1, mild; 2, moderate; and 3, severe. Hemodynamic parameters were evaluated invasively by means of a Swan-Ganz catheter during routine endomyocardial biopsies. Results: The mean follow-up time was 26.9 +/- 5.4 months (range, 12-36 months). In group I, 1 patient (6.6%) died from infection in the 18th month after the operation; the death was not related to the annuloplasty. In group II, 1 death (6.6%) occurred after 10 months because of rejection (P > .05). After the 24-month follow-up, the mean degree of tricuspid insufficiency was 0.4 +/- 0.5 in group I and 1.7 +/- 0.9 in group II (P < .05). Similarly, the 2 groups were significantly different with respect to the right atrium pressure, which was higher in group II. Conclusions: Prophylactic tricuspid annuloplasty on the donor heart was able to reduce significantly the degree of valvular insufficiency, even in cardiac transplantation with bicaval anastomosis; however, it did not modify significantly the hemodynamic performance of the allograft during the investigation period. It is very important to extend the observation period and casuistics to verify other benefits that this technique may offer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Several factors have been implicated in the high-mortality rate of posttraumatic pneumonectomy. In this study, we evaluated the hemodynamic and echocardiographic changes induced by pneumonectomy and fluid resuscitation after hemorrhagic shock. Methods: Fourteen dogs were bled to a target mean arterial pressure of 40 mmHg. The animals were assigned to two groups: control (no fluid resuscitation) and lactated Ringer`s (3 x shed blood volume). The left pulmonary hilum was cross clamped, and the animals were observed for 60 minutes. Systemic hemodynamics was evaluated using Swan-Ganz, arterial catheter, and ultrasonic flow probe. Systemic O(2)-derived variables were calculated. Ejection fraction was determined by two-dimensional echocardiography. Results: Fluid resuscitation improved the mean arterial pressure and systemic oxygen delivery. After pneumonectomy, no significant increase in right ventricular pressure was observed in the LR group. No signs of major ventricular dilation or changes in arterial oxygenation were observed. Conclusion: Our data suggest that pneumonectomy is not associated with early pulmonary hypertension; gentle fluid resuscitation improves cardiovascular performance and is not associated with an increase in right ventricular pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the impact of obesity on the abnormalities of systolic and diastolic regional left ventricular (LV) function in patients with or without hypertension or hypertrophy, and without heart failure. We studied 120 individuals divided into 6 groups of 20 patients (42 +/- 6 years, 60 females) using standard and pulsed-wave tissue Doppler imaging (TDI) echocardiography, and heterogeneity index (HI): nonobese (I: no hypertension, no hypertrophy, control group; II: hypertension, no hypertrophy; III: hypertension and hypertrophy) and obese (IV: no hypertension, no hypertrophy; V: hypertension, no hypertrophy; VI: hypertension and hypertrophy). The criterion for obesity was BMI >= 30 kg/m(2), for hypertension was blood pressure >= 140/90 mm Hg, for hypertrophy in nonobese was LV mass/body surface area (BSA) >134 g/m(2) (men) and >110 mg/m(2) (women), and in obese was LV mass/height((2.7)) >50 (men) and >40 (women). Obese groups had normal LV ejection fraction compared with nonobese groups, but decreased longitudinal and radial systolic myocardial peak velocities (S`), and early diastolic myocardial peak velocity (E`). Also, a great variability of E` and late diastolic myocardial peak velocity (A`) from the longitudinal basal region was observed in obese groups (E` basal nonobese: 11 +/- 7 vs. obese 19 +/- 11, P < 0.001, A` basal nonobese: 7 +/- 4 vs. obese 11 +/- 7, P < 0.001). Our findings were more evident when comparing groups IV with V and VI, with the latter having concentric hypertrophy and obvious segmental systolic and diastolic dysfunctions. Subclinical myocardial alterations and increased variability of the velocities were observed in obese groups, especially with hypertension and hypertrophy, reflecting impaired regional LV relaxation, segmental atrial, and systolic dysfunctions.