37 resultados para Design Based Research


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recently, the development of industrial processes brought on the outbreak of technologically complex systems. This development generated the necessity of research relative to the mathematical techniques that have the capacity to deal with project complexities and validation. Fuzzy models have been receiving particular attention in the area of nonlinear systems identification and analysis due to it is capacity to approximate nonlinear behavior and deal with uncertainty. A fuzzy rule-based model suitable for the approximation of many systems and functions is the Takagi-Sugeno (TS) fuzzy model. IS fuzzy models are nonlinear systems described by a set of if then rules which gives local linear representations of an underlying system. Such models can approximate a wide class of nonlinear systems. In this paper a performance analysis of a system based on IS fuzzy inference system for the calibration of electronic compass devices is considered. The contribution of the evaluated IS fuzzy inference system is to reduce the error obtained in data acquisition from a digital electronic compass. For the reliable operation of the TS fuzzy inference system, adequate error measurements must be taken. The error noise must be filtered before the application of the IS fuzzy inference system. The proposed method demonstrated an effectiveness of 57% at reducing the total error based on considered tests. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

introducing a pharmaceutical product on the market involves several stages of research. The scale-up stage comprises the integration of previous phases of development and their integration. This phase is extremely important since many process limitations which do not appear on the small scale become significant on the transposition to a large one. Since scientific literature presents only a few reports about the characterization of emulsified systems involving their scaling-up, this research work aimed at evaluating physical properties of non-ionic and anionic emulsions during their manufacturing phases: laboratory stage and scale-up. Prototype non-ionic (glyceryl monostearate) and anionic (potassium cetyl phosphate) emulsified systems had the physical properties by the determination of the droplet size (D[4,3 1, mu m) and rheology profile. Transposition occurred from a batch of 500-50,000 g. Semi-industrial manufacturing involved distinct conditions: intensity of agitation and homogenization. Comparing the non-ionic and anionic systems, it was observed that anionic emulsifiers generated systems with smaller droplet size and higher viscosity in laboratory scale. Besides that, for the concentrations tested, augmentation of the glyceryl monostearate emulsifier content provided formulations with better physical characteristics. For systems with potassium cetyl phosphate, droplet size increased with the elevation of the emulsifier concentration, suggesting inadequate stability. The scale-up provoked more significant alterations on the rheological profile and droplet size on the anionic systems than the non-ionic. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. To assess the histopathological, immunohistochemical (IHC), and in situ hybridization (ISH) features found in the submandibular (SM) and sublingual (SL) glands of 105 acquired immunodeficiency syndrome (AIDS) patients at autopsy. Study design. Gender, age, CD4 cell level, and clinical histories were obtained from clinical charts (SM: n = 103; SL: n = 92). Histologic analysis of hematoxylin and eosin, Gomori-Grocott, and Ziehl-Neelsen stained tissues, IHC to detect infectious agents and characterize inflammatory cells in sialadenitis, and ISH for EBER-1/2 were performed. Results. The mean age of the patients and CD4 cell count were 36 years and 76 cells/mu L, respectively. Fifty-eight cases (SM: n = 51 [49%]; SL: n = 54 [59%]) were considered to be microscopically normal. The most common infectious conditions were mycobacteriosis (SM: n = 11 [10%]; SL: n = 7 [7%]), followed by cytomegalovirus (CMV) (SM: n = 14 [13%]; SL: n = 2 [2%]), and cryptococcosis (SM: n = 3 [3%]; SL: n = 4 [4%]). Human immunodeficiency virus (HIV) p24 (SM: n = 2 [2%]; SL: n = 1 [1%]) and EBER-1/2 (SM: n = 9 [39%]; SL: n = 4 [20%]) were seen only in macrophages and lymphocytes, respectively. The most prevalent cells seen in chronic nonspecific sialadenitis (SM: n = 25; SL: n = 25) were CD8+ T lymphocytes, whereas CD68+ macrophages were predominant in the mycobacteriosis-associated granulomatous and nonspecific diffuse macrophagic sialadenitis. Concomitant infections occurred in 5 cases (SM: n = 4; SL: n = 1) and non-Hodgkin lymphoma in 1 case. Conclusions. Infectious diseases and chronic nonspecific sialadenitis were the main alterations found in the SM and SL glands. These alterations were greater in the SM than in the SL glands. CD8+ T lymphocytes and CD68+ macrophages might be relevant to the pathogenesis of the sialadenitis. Clinicians should consider these diseases when assessing the major salivary glands in advanced AIDS patients and follow biosafety procedures to avoid contamination by HIV, CMV, mycobacteriosis, and cryptococcosis. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 216-226)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Degenerative aortic valve disease (DAVD), a common finding in the elderly, is associated with an increased risk of death due to cardiovascular causes. Taking advantage of its longitudinal design, this study evaluates the prevalence of DAVD and its temporal associations with long-term exposure to cardiovascular risk factors in the general population. We studied 953 subjects (aged 25-74 years) from a random sample of German residents. Risk factors had been determined at a baseline investigation in 1994/95. At a follow-up investigation, 10 years later, standardized echocardiography determined aortic valve morphology and aortic valve area (AVA) as well as left ventricular geometry and function. At the follow-up study, the overall prevalence of DAVD was 28%. In logistic regression models adjusting for traditional cardiovascular risk factors at baseline age (OR 2.0 [1.7-2.3] per 10 years, P < 0.001), active smoking (OR 1.7 [1.1-2.4], P = 0.009) and elevated total cholesterol levels (OR 1.2 [1.1-1.3] per increase of 20 mg/dL, P < 0.001) were significantly related to DAVD at follow-up. Furthermore, age, baseline status of smoking, and total cholesterol level were significant predictors of a smaller AVA at follow-up study. In contrast, hypertension and obesity had no detectable relationship with long-term changes of aortic valve structure. In the general population we observed a high prevalence of DAVD that is associated with long-term exposure to elevated cholesterol levels and active smoking. These findings strengthen the notion that smoking cessation and cholesterol lowering are promising treatment targets for prevention of DAVD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Context Diffusion tensor imaging (DTI) studies in adults with bipolar disorder (BD) indicate altered white matter (WM) in the orbitomedial prefrontal cortex (OMPFC), potentially underlying abnormal prefrontal corticolimbic connectivity and mood dysregulatioin in BD. Objective: To use tract-based spatial statistics (TBSS) to examine VVM skeleton (ie, the most compact whole-brain WM) in subjects with BD vs healthy control subjects. Design: Cross-sectional, case-control, whole-brain DTI using TBSS. Setting: University research institute. Participants: Fifty-six individuals, 31 having a DSM-IV diagnosis of BD type 1 (mean age, 35.9 years [age range, 24-52 years]) and 25 controls (mean age, 29.5 years [age range, 19-52 years]). Main Outcome Measures: Fractional anisotropy (FA) longitudinal and radial diffusivities in subjects with BD vs controls (covarying for age) and their relationships with clinical and demographic variables. Results: Subjects with BD vs controls had significantly greater FA (t > 3.0, P <=.05 corrected) in the left uncinate fasciculus (reduced radial diffusivity distally and increased longitudinal diffusivity centrally), left optic radiation (increased longitudinal diffusivity), and right anterothalamic radiation (no significant diffusivity change). Subjects with BD vs controls had significantly reduced FA (t > 3.0, P <=.05 corrected) in the right uncinate fasciculus (greater radial diffusivity). Among subjects with BD, significant negative correlations (P <.01) were found between age and FA in bilateral uncinate fasciculi and in the right anterothalamic radiation, as well as between medication load and FA in the left optic radiation. Decreased FA (P <.01) was observed in the left optic radiation and in the right anterothalamic radiation among subjects with BD taking vs those not taking mood stabilizers, as well as in the left optic radiation among depressed vs remitted subjects with BD. Subjects having BD with vs without lifetime alcohol or other drug abuse had significantly decreased FA in the left uncinate fasciculus. Conclusions: To our knowledge, this is the first study to use TBSS to examine WM in subjects with BD. Subjects with BD vs controls showed greater WM FA in the left OMPFC that diminished with age and with alcohol or other drug abuse, as well as reduced WM FA in the right OMPFC. Mood stabilizers and depressed episode reduced WM FA in left-sided sensory visual processing regions among subjects with BD. Abnormal right vs left asymmetry in FA in OMPFC WM among subjects with BD, likely reflecting increased proportions of left-sided longitudinally aligned and right-sided obliquely aligned myelinated fibers, may represent a biologic mechanism for mood dysregulation in BD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of a 10% carbamide peroxide-containing bleaching agent on brushing abrasion of esthetic restorative materials. Methods: Using a randomized complete block design, 150 specimens (n = 15) measuring 3 x 3 x 2 mm were fabricated into acrylic resin cylinders, using one of the restorative materials: a microfilled resin composite (At), a hybrid resin composite (Ch), a flowable resin composite (Wa), a resin-modified glass-ionomer cement (Fj) and a polyacid-modified resin composite (Dy). The bleaching agent or artificial saliva (control) was applied for 2 hours/day. After that, 120 brushing strokes were simulated automatically and the samples were kept in artificial saliva. Such bleaching/brushing cycle was performed daily for 21 days. Wear depth was assessed using profilometry. Results: Bleaching did not show significant effect on wear depth. There was a significant difference among the restorative materials. Tukey`s test showed that (Al=Ch) < (Wa) < (Fj) and that Dy was only different from Fj. (Am J Dent 2009;22:171-174).