551 resultados para Lateral Inverse Proximity Effect


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Few studies have investigated in vivo changes of the cholinergic basal forebrain in Alzheimer`s disease (AD) and amnestic mild cognitive impairment (MCI), an at risk stage of AD. Even less is known about alterations of cortical projecting fiber tracts associated with basal forebrain atrophy. In this study, we determined regional atrophy within the basal forebrain in 21 patients with AD and 16 subjects with MCI compared to 20 healthy elderly subjects using deformation-based morphometry of MRI scans. We assessed effects of basal forebrain atrophy on fiber tracts derived from high-resolution diffusion tensor imaging (DTI) using tract-based spatial statistics. We localized significant effects relative to a map of cholinergic nuclei in MRI standard space as determined from a postmortem brain. Patients with AD and MCI subjects showed reduced volumes in basal forebrain areas corresponding to anterior medial and lateral, intermediate and posterior nuclei of the Nucleus basalis of Meynert (NbM) as well as in the diagonal band of Broca nuclei (P < 0.01). Effects in MCI subjects were spatially more restricted than in AD, but occurred at similar locations. The volume of the right antero-lateral NbM nucleus was correlated with intracortical projecting fiber tract integrity such as the corpus callosum, cingulate, and the superior longitudinal, inferior longitudinal, inferior fronto-occipital, and uncinate fasciculus (P < 0.05, corrected for multiple comparisons). Our findings suggest that a multimodal MRI-DTI approach is supportive to determine atrophy of cholinergic nuclei and its effect on intracortical projecting fiber tracts in AD. Hum Brain Mapp 32: 1349-1362, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of the opaque layer firing temperature and mechanical and thermal cycling on the flexural strength of a ceramic fused to commercial cobalt-chromium alloy (Co-Cr). The hypotheses were that higher opaque layer temperatures increase the metal/ceramic bond strength and that aging reduces the bond strength. Materials and Methods: Metallic frameworks (25 x 3 x 0.5 mm(3); ISO 9693) (N = 60) were cast in Co-Cr and airborne-particle abraded (Al(2)O(3): 150 mu m) at the central area of the frameworks (8 x 3 mm(2)) and divided into three groups (N = 20), according to the opaque layer firing temperature: Gr1 (control)-900 degrees C; Gr2-950 degrees C; Gr3-1000 degrees C. The opaque ceramic (Opaque, Vita Zahnfabrick, Bad Sackingen, Germany) was applied, and the glass ceramic (Vita Omega 900, Vita Zahnfabrick) was fired onto it (thickness: 1 mm). While half the specimens from each group were randomly tested without aging (water storage: 37 degrees C/24 hours), the other half were mechanically loaded (20,000 cycles; 50 N load; distilled water at 37 degrees C) and thermocycled (3000 cycles; 5 degrees C to 55 degrees C, dwell time: 30 seconds). After the flexural strength test, failure types were noted. The data were analyzed using 2-way ANOVA and Tukey`s test (alpha = 0.05). Results: Gr2 (19.41 +/- 5.5 N) and Gr3 (20.6 +/- 5 N) presented higher values than Gr1 (13.3 +/- 1.6 N) (p = 0.001). Mechanical and thermal cycling did not significantly influence the mean flexural strength values (p > 0.05). Increasing the opaque layer firing temperature improved the flexural bond strength values (p < 0.05). The hypotheses were partially accepted. Conclusion: Increasing of the opaque layer firing temperature improved the flexural bond strength between ceramic fused to Co-Cr alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the impact of acute PaCO(2) temporal variation on the standard base excess (SBE) value in critically ill patients. Methods: A total of 265 patients were prospectively observed; 158 were allocated to the modeling group, and 107 were allocated to the validation group. Two models were developed in the modeling group (one including and one excluding PaCO(2) as a variable determinant of SBE), and both were tested in the validation group. Results: In the modeling group, the mathematical model including SIDai, SIG, L-lactate, albumin, phosphate, and PaCO(2) had a predictive superiority in comparison with the model without PaCO(2) (R(2) = 0.978 and 0.916, respectively). In the validation group, the results were confirmed with significant F change statistics (R(2) change = 0.059, P < .001) between the model with and without PaCO(2). A high correlation (R = 0.99, P < .001) and agreement (bias = -0.25 mEq/L, limits of agreement 95% = -0.72 to 0.22 mEq/L) were found between the model-predicted SBE value and the SBE calculated using the Van Slyke equation. Conclusions: Acute PaCO(2), temporal variation is related to SBE changes in critically ill patients. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To analyze the effects of variations in femtosecond laser energy level on corneal stromal cell death. and inflammatory cell influx following flap creation in a rabbit model. METHODS: Eighteen rabbits were stratified in three different groups according to level of energy applied for flap creation (six animals per group). Three different energy levels were chosen for both the lamellar and side cut; 2.7 mu J (high energy), 1.6 mu J (intermediate energy), and 0.5 mu J (low energy) with a 60 kHz, model II, femtosecond laser (IntraLase). The opposite eye of each rabbit served as a control. At the 24-hour time point after surgery, all rabbits were euthanized and the comeoscleral rims were analyzed for the levels of cell death and inflammatory cell influx with the terminal uridine deoxynucleotidyl transferase dUTP-nick end labeling (TUNEL) assay and immunocytochemistry for monocyte marker CD11b, respectively. RESULTS: The high energy group (31.9 +/- 7.1 [standard error of mean (SEM) 2.9]) had significantly more TUNEL positive cells in the central flap compared to the intermediate (22.2 +/- 1.9 [SEM 0.8], P=.004), low (17.9 +/- 4.0 [SEM 1.6], P <= .001), and control eye (0.06 +/- 0.02 [SEM 0.009], P <= .001) groups. The intermediate and low energy groups also had significantly more TUNEL positive cells than the control groups (P <= .001). The difference between the intermediate and low energy levels was not significant (P=.56). The mean for CD11b-positive cells/400x field at the flap edge was 26.1 +/- 29.3 (SEM 11.9), 5.8 +/- 4.1 (SEM 1.6), 1.6 +/- 4.1 (SEM 1.6), and 0.005 +/- 0.01 (SEM 0.005) for high energy, intermediate energy, low energy, and control groups, respectively. Only the intermediate energy group showed statistically more inflammatory cells than control eyes (P = .015), most likely due to variability between eyes. CONCLUSIONS: Higher energy levels trigger greater cell death when the femtosecond laser is used to create corneal flaps: Greater corneal inflammatory cell infiltration is observed with higher femtosecond laser energy levels. [J Refract Surg. 2009;25:869-874.] doi:10.3928/1081597X-20090917-08

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Noninvasive positive-pressure ventilation (NPPV) modes are currently available on bilevel and ICU ventilators. However, little data comparing the performance of the NPPV modes on these ventilators are available. Methods: In an experimental bench study, the ability of nine ICU ventilators to function in the presence of leaks was compared with a bilevel ventilator using the IngMar ASL5000 lung simulator (IngMar Medical; Pittsburgh, PA) set at a compliance of 60 mL/cm H(2)O, an inspiratory resistance of 10 cm H(2)O/L/s, an expiratory resistance of 20 cm H(2)O/L/s, and a respiratory rate of 15 breaths/min. All of the ventilators were set at 12 cm H(2)O pressure support and 5 cm H(2)O positive end-expiratory pressure. The data were collected at baseline and at three customized leaks. Main results: At baseline, all of the ventilators were able to deliver adequate tidal volumes, to maintain airway pressure, and to synchronize with the simulator, without missed efforts or auto-triggering. As the leak was increased, all of the ventilators (except the Vision [Respironics; Murrysville, PA] and Servo I [Maquet; Solna, Sweden]) needed adjustment of sensitivity or cycling criteria to maintain adequate ventilation, and some transitioned to backup ventilation. Significant differences in triggering and cycling were observed between the Servo I and the Vision ventilators. Conclusions: The Vision and Servo I were the only ventilators that required no adjustments as they adapted to increasing leaks. There were differences in performance between these two ventilators, although the clinical significance of these differences is unclear. Clinicians should be aware that in the presence of leaks, most ICU ventilators require adjustments to maintain an adequate tidal volume. (CHEST 2009; 136:448-456)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: to evaluate the effect of an immersion bath on pain magnitude during the first stage of tabour. Design: a randomised controlled trial comparing the pain scores of bathing and non-bathing nulliparous women during birth was employed. Setting: the study was conducted at the Normal Birth Center of Amparo Maternal, Sao Paulo, Brazil. Participants: 108 birthing women, with 54 women randomly assigned to each group. Interventions: when the birthing women presented at 6-7cm of cervical dilation, they were placed in an immersion bath for 60 mins. Outcome measures: pain scores, using a behavioural pain scale and a numeric scale, were recorded at two evaluation time points: at 6-7cm of cervical dilation and 1 h after the first pain score evaluation. Findings: at the first evaluation, on the behavioural scale, the means were 2.1 for both groups (p = 0.914; 95% confidence intervals (CI) 1.9-2.3 for the control group and 2.0-2.2 for the experimental group). On the numeric scale, the means were 8.7 and 8.5 for the control and experimental groups, respectively (p = 0.235; 95% Cl 8.2-9.2 for the control group and 8.1-8.9 for the experimental group). At the second evaluation, the pain score means for both scales were statistically higher in the control group than in the experimental group. On the behavioural scale, the scores were 2.4 vs. 1.9, respectively, for the control and experimental groups (p<0.001; 95% Cl 2.2-2.6 for the control group and 1.7-2.1 for the experimental group). On the numeric scale, the scores were 9.3 vs. 8.5, respectively, for the control and experimental groups (p<0.05; 95% Cl 8.9-9.7 for the control group and 8.1-8.9 for the experimental group). Conclusions: mean tabour pain scores in the control group were significantly higher than those in the experimental group. The present findings suggest that use of an immersion bath is a suitable alternative form of pain relief for women during tabour. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Little is known about the treatment of depression in older patients with heart failure. This Study was developed to investigate the effectiveness of antidepressant treatment for major depressive disorder (MDD) in the elderly with heart failure. Methods: We enrolled 72 older outpatients with ejection fraction < 50 and diagnosed with MDD by the structured clinical interview for DSM-IV. Thirty-seven patients, 19 on citalopram and 18 on placebo, initiated an 8-week double-blind treatment phase. Measurements were performed with the 31-item Hamilton Rating Scale for Depression (Ham-D-31), the Montgomery-Asberg rating scale (MADRS) and the Systematic Assessment for Treatment Emergent Effects (SAFTEE). A psychiatrist followed up the patients weekly, performing a consultation for about 20 min to field complaints after the measurements. Results: A trend toward superiority of citalopram over placebo in reducing depression was observed in MADRS scores (15.05 + 9.74 vs 9.44 + 9.25, P = .082) but not on HAM-D scores. The depressive symptomatology significantly decreased in both groups (P < .001). The high rate of placebo response during the double-blind phase (56.3%) led us to conclude the study at the interim analysis with 37 patients. Conclusion: Citalopram treatment of MDD in older patients with heart failure is well-tolerated with low rates of side effects, but was not significantly more effective than placebo in the treatment of depression. Weekly psychiatric follow-up including counseling may contribute to the improvement of depression in this population. Scales weighted on psychological symptoms such as the MADRS are possibly better suited to measure depression severity and improvement in patients with heart failure. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Samuel Hahnemann noticed that palliative treatments for the symptoms of chronic diseases, after an initial improvement, provoked symptoms similar but stronger symptoms to those initially suppressed. He regarded this as a consequence of the vital reaction of the organism: an automatic and instinctive capacity to return to the initial health condition altered by medicines. Using this homeostatic conception of the organism as a treatment rationale, Hahnemann proposed the therapy of similarity, administering to the patients medicines capable of causing, in healthy individuals, similar symptoms to the natural disease. Based on experimental observations, he proposed that the primary action of the drug was followed by the secondary and opposite action of the organism, inaugurating homeopathic pharmacology, and alerting to the harmful consequences of palliative medicines in susceptible individuals. Such liatrogenic events can be observed in contemporary medicine, after the withdrawal of modern enantiopathic medicines, according to the study of the rebound effect or paradoxical reaction of the organism. Method. This study reviews the recent studies which describe suicidallity after the suspension or discontinuation of second generation antidepressants according to the hypothesis of the paradoxical reaction of the organism. Conclusions: Rebound and withdrawal effects, including suicidality occur with antidepressant drugs. They are relatively rare but more intense than the primary action of the drug. The probability of such effects is influenced by patient factors including age and diagnosis, and drug factors including half-life. Homeopathy (2009) 98, 114-121.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The objective of this study was to compare personality traits between major depressive disorder (MDD) patients and healthy comparison subjects (HC) and examine if personality traits in patients are associated with specific clinical characteristics of the disorder. Methods: Sixty MDD patients (45 depressed, 15 remitted) were compared to 60 HC using the Temperament and Character Inventory. Analysis of covariance, with age and gender as covariates, was used to compare the mean Temperament and Character Inventory scores among the subject groups. Results: Depressed MDD patients scored significantly higher than HC on novelty seeking, harm avoidance, and self-transcendence and lower on reward dependence, self-directedness, and cooperativeness. Remitted MDD patients scored significantly lower than HC only on self-directedness. Comorbidity with anxiety disorder had a main effect only on harm avoidance. Harm avoidance was positively correlated with depression intensity and with number of episodes. Self-directedness bad an inverse correlation with depression intensity. Conclusions: MDD patients present a different personality profile from HC, and these differences are influenced by mood state and comorbid anxiety disorders. When considering patients who have been in remission for some time, the differences pertain to few personality dimensions. Cumulated number of depressive episodes may result in increased harm avoidance. Depression and Anxiety 26.382-388, 2009. (c) 2009 Wiky-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To compare morphometric data of the eyelid fissure and the levator muscle function (LF) before and up to 6 months after transcutaneous injection with five units of Botox (R) in patients with upper lid retraction (ULR) from congestive or fibrotic thyroid eye disease (TED). Methods Twenty-four patients with ULR from TED were submitted to transcutaneous injection of 5 units (0.1 ml) of Botox in one eye only. Patients were divided into two groups: 12 with congestive-stage TED (CG), and 12 with fibrotic-stage TED (FG). Bilateral lid fissure measurements using digital imaging and computer-aided analysis were taken at baseline and at regular intervals 2 weeks, 1 month, 3 months and 6 months after unilateral Botox injection. Mean values taken at different follow-up points were compared for the two groups. Results Most patients experienced marked improvement in ULR, with a mean reduction of 3.81 mm in FG and 3.05 mm in CG. The upper eyelid margin reflex distance, fissure height and total area of exposed interpalpebral fissure were significantly smaller during 1 month in CG and during 3 months in FG. Reduction in LF and in the difference between lateral and medial lid fissure measurements was observed in both groups. The treatment lasted significantly longer in FG than in CG. Conclusions A single 5-unit Botox injection improved ULR, reduced LF and produced an adequate lid contour in patients with congestive or fibrotic TED. The effect lasts longer in patients with fibrotic orbitopathy than in patients with congestive orbitopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last few decades, inhaled corticosteroids (ICs) became the cornerstone in the treatment of persistent asthma. Their use improved asthma control, decreased mortality and also minimized adverse reactions associated with systemic steroid. Esophageal candidiasis is a rare complication resulting from the use of ICs. Although, in recent years, as their prescriptions has increased, more cases have been reported, especially in Japan. Listed are 4 case reports regarding esophageal candidiasis in asthmatic patients associated with inhaled budesonide administration. In the cases reported herein, the use of a different device of dry powder budesonide might have favored esophageal drug deposition and Candida infection. Patients denied using systemic corticosteroids in the previous 6 months. Furthermore, none of the patients presented Diabetes mellitus, malignant disease, HIV infection, or other immunosuppressive conditions. We conclude that patients treated with high doses of ICs are at higher risk of developing esophageal candidiasis. These patients should undergo upper gastrointestinal endoscopy whenever they present symptoms. Nevertheless, we must keep in mind that infection might also be asymptomatic and esophageal candidiasis prevalence may be higher than that reported thus far.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to quantify presence of residual BCC in patients with histologic positive margins after the first excison and to correlate the presence of residual tumor in re-excised lesions with the location of the positive margin on the first excision, a retrospective evaluation of 2053 surgically treated BCC was performed. Only 38.3% of the re-excised lesions showed residual tumor. In the group of re-excised lesions where residual BCC was found, 13% had lateral positive margin in the first excision, 39% had deep positive margin and 48% had both lateral and deep positive margins. In the group of re-excised lesions where no residual BCC was found, 49% of the primary excised lesions had lateral positive margin, 32% had deep positive margin and 19% had both deep and lateral positive margins. The association between residual tumor and positive margins was statistically significant (p = 0.01). Our findings confirm that presence of residual tumour is more likely when both lateral and deep margins are compromised.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context.-Studies analyzing the concordance of biopsy and radical prostatectomy (RP) Gleason scores have limitations. Some included 2 or more centers, used historical controls from the early prostate specific antigen era or lacked a clear definition of the biopsy schemes. Furthermore, most did not control the results for prostate volume. Objective.-To confirm whether prediction of RP Gleason score can be optimized by taking more biopsy cores in a contemporary series of patients, with pathologic samples analyzed by the same pathologist, and controlling these results for prostate volume. Design.-The study comprised a retrospective case-control analysis of 393 patients with prostate cancer treated with RP. Patients were divided into 3 groups: those in group 1 underwent a 6-core biopsy; group 2, an 8-core biopsy; and group 3, a 10 or more-core biopsy. Concordance rates between biopsy and RP Gleason scores, as well as the rates of undergrading and overgrading, were determined for each biopsy scheme. Results.-Concordance rates were 60.9%, 58.3%, and 64.6% for patients from groups 1, 2, and 3, respectively (P = .18). When we analyzed patients with prostate volumes of less than 50 cm(3), concordance rates were 58.3%, 58.3%, and 65.1% for each group, respectively (P = .03). Among patients with prostate volumes of 50 cm3 or more, concordance rates were 70%, 58.1%, and 63.6%, respectively (P = .66). Conclusions.-Taking 10 or more cores can improve the prediction of RP Gleason score in patients with prostate volumes of less than 50 cm3. For patients with prostate volumes of 50 cm3 or more, increasing the biopsy cores to 10 or more did not improve prediction of RP Gleason score.