56 resultados para reliability and validity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a ""mission"" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop and validate the Disordered Eating Attitude Scale to measure disordered eating attitudes, defined as abnormal beliefs, thoughts, feelings, behaviors, and relationship regarding food. Exploratory factor analysis was performed and internal consistency assessed in a sample of female university students (N=196). Convergent validity was acceptable based on statistically significant correlations with the Eating Attitude Test-26 and Restraint Scale. Known-groups validity was determined by comparing the student sample`s mean scores against scores of an eating disorder group (N=51). The Disordered Eating Attitude Scale comprises 25 questions and five subscales explaining 54.3% of total variance. The total scores differentiated student, bulimia, and anorexia groups. The scale should prove useful for evaluating eating attitudes in various population groups and eating disordered patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este estudo teve como objetivo realizar a adaptação cultural do The Environmental Stressor Questionnaire - (ESQ) para a língua portuguesa do Brasil e verificar sua confiabilidade e validade. Foram empregadas as etapas metodológicas recomendadas pela literatura para adaptação cultural. A versão brasileira do ESQ foi aplicada a 106 pacientes de Unidade de Terapia Intensiva (UTI) de dois hospitais, público e privado, do interior do Estado de São Paulo. A confiabilidade foi avaliada quanto à consistência interna e estabilidade (teste e reteste); a validade convergente foi verificada por meio da correlação entre o ESQ e questão genérica sobre estresse em UTI. A confiabilidade foi satisfatória com Alfa de Crombach=0,94 e Coeficiente de Correlação Intraclasse=0,861 (IC95% 0,723; 0,933). Constatou-se correlação entre o escore total do ESQ e a questão genérica sobre estresse (r=0,70), confirmando a validade convergente. A versão brasileira do ESQ mostrou-se uma ferramenta confiável e válida para avaliação de estressores em UTI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a reprodutibilidade e a validade de indicadores de atividade física e sedentarismo, obtidos por sistema de vigilância baseado em inquéritos telefônicos. MÉTODOS: Foram realizadas análises de reprodutibilidade e validade em duas subamostras aleatórias (n=110 e n=111, respectivamente) da amostra total (N=2.024) de adultos (>18 anos), estudada pelo sistema, no município de São Paulo, em 2005. Os indicadores avaliados incluíram a freqüência de "suficientemente ativos no lazer", "inativos em quatro domínios da atividade física (lazer, trabalho, transporte e atividades domésticas)" e "ver televisão por longos períodos". A reprodutibilidade foi estudada comparando-se resultados obtidos a partir da entrevista telefônica original do sistema e de outra entrevista idêntica repetida após sete a 15 dias e feita por entrevistador diferente do que fez a entrevista original. A validade foi estudada comparando-se resultados obtidos a partir da entrevista telefônica original e de três recordatórios de 24 horas (método de referência) realizados na semana seguinte à entrevista original. RESULTADOS: A freqüência dos três indicadores avaliados foi idêntica ou muito próxima entre a primeira e a segunda entrevistas telefônicas, e os coeficientes kappa se situaram entre 0,53 e 0,80, indicando boa reprodutibilidade de todos os indicadores. Relativamente ao método de referência, evidenciou-se especificidade de 80% ou mais para os três indicadores e sensibilidade de 69,7% para "ver televisão por longos períodos", 59,1% para "inativos em quatro domínios" e 50% para "suficientemente ativos no lazer". CONCLUSÕES: Os indicadores de atividade física e sedentarismo empregados pelo sistema aparentam ser reprodutíveis e suficientemente acurados. Se mantido em operação nos próximos anos, o sistema poderá oferecer ao Brasil um instrumento útil para avaliação de políticas públicas de promoção da atividade física e controle das doenças crôni

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is no doubt about the importance of service quality as a factor of businesses' success, but to measure this quality has proved to be a challenge when one considers different environmental contexts. Given this, the main goal of this paper was to test two measurement scales of perceived set-vice quality. The comparison between Service Quality scale (Servqual) and Retail Set-vice Quality (RSQ) was conducted by means of a survey with 351 participants, clients of a home center stores chain located in the city of Sao Paulo. The data were analyzed using both exploratory and confirmatory factor analysis. As a result, both scales demonstrated acceptable levels of reliability and validity However; the RSQ demonstrated a better performance in the nomological test since it was able to explain 43% of the loyalty towards the retailer; while the Servqual scale explained only 11%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The perception of improvement by a patient has assumed a central role in functional evaluation after a variety of knee problems. One of the instruments most used in clinical research is the International Knee Documentation Committee (IKDC) Subjective Knee Form because its psychometric properties are considered to be excellent. Nonetheless, this questionnaire was originally developed for use in the English language. Therefore, to use this questionnaire in the Brazilian population, it is essential to translate and validate it. Purpose: The aim of this study was to translate the IKDC Subjective Knee Form into a Brazilian version and to test its validity and reproducibility. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: The translation of the original IKDC Subjective Knee Form into a Brazilian version was accomplished in accordance with the American Orthopaedic Society for Sports Medicine guidelines and was tested in 32 patients with knee pathologic conditions to develop the first Brazilian version. To test validity and reproducibility, 117 patients with several knee complaints completed the Brazilian IKDC Subjective Knee Form, the Short Form 36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Lysholm score. From these patients, 85 were retested within a week to achieve reproducibility. The validation was addressed by correlating the Brazilian IKDC Subjective Knee Form to the other outcome measures. The reproducibility was tested by measuring internal consistency, test-retest reliability, and agreement. Results: The Brazilian IKDC Subjective Knee Form was highly related to the physical component summary of the SF-36, the Lysholm score, and the WOMAC, and weakly related to the mental component summary of SF-36 (r=.79, .89, .85, and .51, respectively). The internal consistency was strong, with a Cronbach a value of .928 and .935 in the test and retest assessment, respectively. The test-retest reliability proved to be excellent, with a high value of the intraclass correlation coefficient (.988), as well as the agreement, demonstrated by the low differences between the means of the test and retest, and the short limit of agreement, observed in the Altman-Bland and survival-agreement plots. Conclusion: The results of this study provide evidence that the Brazilian IKDC Subjective Knee Form has psychometric properties similar to the original version. In addition, it was a reliable evaluation instrument for patients with knee-related problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to validate the Piper Fatigue Scale-Revised (PFS-R) for use in Brazilian culture. Translation of the PFS-R into Portuguese and validity and reliability tests were performed. Convenience samples in Brazil we as follows: 584 cancer patients (mean age 57 +/- 13 years; 51.3% female); 184 caregivers (mean age 50 +/- 12.7 years; 65.8% female); and 189 undergraduate nursing students (mean age 21.6 +/- 2.8 years; 96.2% female); Instruments used were as follows: Brazilian PFS, Beck Depression Inventory (BDI), and Karnofsky Performance Scale (KPS). The 22 items of the Brazilian PFS loaded well (factor loading > 0.35) on three dimensions identified by factor analysis (behavioral, affective, and sensorial-psychological). These dimensions explained 65% of the variance. Internal consistency reliability was very good (Cronbach`s alpha ranged from 0.841 to 0.943 for the total scale and its dimensions). Cancer patients and their caregivers completed the Brazilian PFS twice for test-retest reliability and results showed good stability (Pearson`s r a parts per thousand yenaEuro parts per thousand 0,60, p < 0,001). Correlations among the Brazilian PFS and other scales were significant, in hypothesized directions, and mostly moderate contributing to divergent (Brazilian PFS x KPS) and convergent validity (Brazilian PFS x BDI). Mild, moderate, and severe fatigue in patients were reported by 73 (12.5%), 167 (28.6%), and 83 (14.2%), respectively. Surprisingly, students had the highest mean total fatigue scores; no significant differences were observed between patients and caregivers showing poor discriminant validity. While the Brazilian PFS is a reliable and valid instrument to measure fatigue in Brazilian cancer patients, further work is needed to evaluate the discriminant validity of the scale in Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The Burns Specific Health Scale-Revised (BSHS-R) is of easy application, can be self-administered, and it is considered a good scale to evaluate various important life aspects of burn victims. Objectives: To translate and culturally adapt the BSHS-R into the Brazilian-Portuguese language and to evaluate the internal consistency and convergent validity of the translated BSHS-R. Methods: The cultural adaptation of the BSHS-R included translation and back-translation, discussions with professionals and patients to ensure conceptual equivalence, semantic evaluation, and pre-test of the instrument. The Final Brazilian-Portuguese Version (FBPV) of the BSHS-R was tested on a group of 115 burn patients for internal consistency and validity of construct (using the Rosenberg Self-Esteem Scale (RSES) and the Beck Depression Inventory (BDI)). Results: All values of Cronbach`s alpha were greater than. 8, demonstrating that the internal consistency of the FBPV was very high. Self-esteem was highly correlated with affect and body image (r = .59, p < .001), and with interpersonal relationships (T = .51, p < .001). Correlations between the domains of the FBPV and the BDI were all negative but larger in magnitude than the correlations with RSES. Depression was highly correlated with affect and body image (r = -77, p < .001), and with interpersonal relationships (r = -67, p < .001). Conclusions: The results showed that the adapted version of the BSHS-R into Brazilian-Portuguese fulfills the validity and reliability criteria required from an instrument of health status assessment for burn patients. (C) 2008 Elsevier Ltd and ISBI. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background:The Nasal Obstruction Symptom Evaluation (NOSE) instrument is a disease-specific questionnaire for assessing the outcome of an intervention in nasal obstruction in trials. This instrument is only available in the English language and cross-culturally valid questionnaires are very important for all research, including nasal obstruction. The aim of the current study was to reproduce the cross-cultural adaptation process for the NOSE questionnaire in the Portuguese language (NOSE-p). Methodology: Cross-cultural adaptation and validation of the instrument were divided into two stages. Stage I involved four bilingual professionals, an expert committee and the author of the original instrument. In Stage 2, the NOSE-p was tested on 33 patients undergoing septoplasty for internal consistency, test-retest reliability, construct validity. discriminant validity, criterion validity, and response sensitivity. Results: The cross-cultural adaptation process was completed and the NOSE-p was demonstrated to be a valid instrument with satisfactory construct validity. It showed an adequate internal consistency reliability and adequate test-retest reliability. It could discriminate between patients with and without nasal obstruction and it has a high response sensitivity to change. Conclusions: The cross-cultural adaptation and validation process demonstrated to be valid and the NOSE-p proved to be applicable in Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examined the psychometric properties of the Brazilian versions of the Fagerstrom Test for Nicotine Dependence (FTND) and the Heaviness of Smoking Index (HSI). The test-retest reliability of the FTND was assessed in a sample of 61 smoking university students, with a 15-day interval between assessments. The interrater reliability was examined in 30 smoking patients of a psychosocial care center for alcohol and drug users (PCC-AD). The reliability coefficient was estimated by the kappa and intraclass correlation coefficients. The predictive validity, internal consistency, and factor structure of the FTND and the HSI were evaluated by factor analysis in 271 smokers treated at an emergency unit and at the PCC-AD. The gold standard was the nicotine dependence criteria of DSM-IV, as assessed by the Structured Clinical Interview for DSM-IV. The FTND showed high reliability, with correlation coefficients of .92 for test-retest reliability and .99 for interrater reliability. Both the FTND and the HSI presented high levels of sensitivity and specificity. The internal consistency evaluation yielded a Cronbach`s alpha coefficient of .83 for the FTND and of .56 for the HSI. An exploratory factor analysis found 2 factors in the FTND, which were validated by a confirmatory factor analysis. The results obtained in this study confirm the validity and reliability of the Brazilian versions of the FTND and the HSI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quality of life (QOL) has been extensively studied in clinical trials and in research on chronic degenerative diseases and dementia. The aim of this study was to assess the reliability and construct validity of the Brazilian version of the QOL scale in Alzheimer`s disease (AD; QOL-AD). The QOL-AD was administered to 60 patients with mild or moderate AD and to their caregivers. The construct validation was accomplished through correlations amongst total scores of patients` and caregivers` reports on patients` quality of life (PQOL and C-PQOL, respectively), and data related to cognitive impairment, depressive symptoms, functional performance, behavioral disturbances and a generic instrument of quality of life (WHOQOL-brief), as well as correlation of total score of caregivers` reports on their own quality of life (CQOL) with the measurements cited above, QOL-AD patient reports, and depressive symptoms. The reliability was high for PQOL, C-PQOL, and CQOL versions (Cronbach`s alpha = 0.80, 0.83, and 0.86, respectively). We observed significant correlations in the construct validity of all three versions regarding the variables associated with the disease and also with WHOQOL-brief. The scale took, on average, six min for each version. The results indicate reliability and construct validity of the Brazilian version of the QOL-AD in the studied sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Prospective and Retrospective Memory Questionnaire (PRMQ) has been shown to have acceptable reliability and factorial, predictive, and concurrent validity. However, the PRMQ has never been administered to a probability sample survey representative of all ages in adulthood, nor have previous studies controlled for factors that are known to influence metamemory, such as affective status. Here, the PRMQ was applied in a survey adopting a probabilistic three-stage cluster sample representative of the population of Sao Paulo, Brazil, according to gender, age (20-80 years), and economic status (n=1042). After excluding participants who had conditions that impair memory (depression, anxiety, used psychotropics, and/or had neurological/psychiatric disorders), in the remaining 664 individuals we (a) used confirmatory factor analyses to test competing models of the latent structure of the PRMQ, and (b) studied effects of gender, age, schooling, and economic status on prospective and retrospective memory complaints. The model with the best fit confirmed the same tripartite structure (general memory factor and two orthogonal prospective and retrospective memory factors) previously reported. Women complained more of general memory slips, especially those in the first 5 years after menopause, and there were more complaints of prospective than retrospective memory, except in participants with lower family income.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Eating attitudes are defined as beliefs, thoughts, feelings, behaviors and relationship with food. They could influence people’s food choices and their health status. Objective: This study aimed to adapt from Portuguese to English the Disordered Eating Attitude Scale (DEAS) and evaluate its validity and reliability. The original scale in Portuguese was translated and adapted into English and was applied to female university students of University of Minnesota—USA (n = 224). Internal consistency was determined (Cronbach’s Alpha). Convergent validity was assessed by correlations between Eating Attitude Test-26 (EAT-26) and Restrain Scale (RS). Reliability was evaluated applying twice the scale to a sub-sample (n = 30). The scale was back translated into Portuguese and compared with the original version and discrepancies were not found. The internal consistency was .76. The DEAS total score was significantly associated with EAT-26 (r = 0.65) and RS (r = 0.69) scores. The correlation between test–retest was r = 0.9. The English version of DEAS showed appropriate internal consistency, convergent validity and test–retest reliability and will be useful to assess eating attitudes in different population groups in English spoken countries