23 resultados para lumped amplifier
Resumo:
Oxidation processes are used in wastewater treatment when conventional processes are not effective due to the presence of recalcitrant organic contaminants, like phenol. However, the presence of ionic compounds associated with organic pollutants may retard the oxidation. In this work the transport of species contained in an aqueous solution of phenol containing sodium chloride was evaluated in an electrodialysis (ED) system. An experimental study was carried out in which the influence of the process variables on the phenol loss and sodium chloride removal was investigated. Experiments were also performed without current, in order to determine the phenol transfer due to diffusion. The phenol and salt concentration variations in the ED compartments were measured over time, using dedicated procedures and an experimental design to determine the global characteristic parameters. A phenomenological approach was used to relate the phenol, salt and water fluxes with the driving forces (concentration and electric potential gradients). Under ED conditions, two contributions were pointed out for the phenol transport, i.e. diffusion and convection, this latter coming from the water flux due to electroosmosis related to the migration of salts. The fitting of the parameters of the transport equations resulted in good agreement with the experimental results over the range of conditions investigated. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
The harmonic distortion (HD) exhibited by un-strained and biaxially strained fin-shaped field-effect transistors operating in saturation as single-transistor amplifiers has been investigated for devices with different channel lengths L and fin widths W(fin). The study has been performed through device characterization, 3-D device simulations, and modeling. Nonlinearity has been evaluated in terms of second- and third-order HDs (HD2 and HD3, respectively), and a discussion on its physical sources has been carried out. Also, the influence of the open-loop voltage gain AV in HD has been observed.
Resumo:
This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made.
Resumo:
In this work we present an analysis of harmonic distortion (HD) in graded-channel (GC) gate-all-a round (GAA) devices operating in saturation region for analog applications. The study has been performed through device characterization and two-dimensional process and device simulations. The overall study has been done on the total and third order HDs. When applied in the saturation regime as an amplifier, the GC outperforms conventional GAA transistors presenting simultaneously higher transconductance, lower drain output conductance and more than 15 dB improved linearity. The influence of channel length reduction on the H D is also analyzed. Although slight linearity degradation is observed in both the conventional and the GC devices when reducing the channel length, the HD presented by the GC transistor is significantly lower than the one showed by conventional device for any Studied channel length. This allows AC input signal amplitude up to 20 times higher than the conventional GAA for a same specified distortion level. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
The present study evaluated the infection of capybaras (Hydrochoerus hydrochaeris) by Rickettsia rickettsii and their role as amplifier hosts for horizontal transmission of R. rickettsii to Amblyomma cajennense ticks. Two groups of two capybaras each were evaluated: on day 0, group 1 (G1) was infested by R. rickettsii-infected ticks, and group 2 (G2) was inoculated intraperitoneally with R. rickettsii. Two additional groups were control groups, not exposed to R. rickettsii, being CG1 group the control of G1, and CG2 group the control of G2. Capybara rectal temperature was measured daily. Blood samples were collected every 3 days during 30 days, and used to (i) inoculate guinea pigs intraperitoneally; (ii) DNA extraction followed by real-time PCR targeting the rickettsial gene gltA; (iii) hematology; (iv) detection of R. rickettsii-reactive antibodies by indirect immunofluorescence assay (IFA). Blood was also collected from G I capybaras every approximate to 10-30 days till the 146th day, to be tested by serology. Capybaras were infested by uninfected A. cajennense nymphs from the 3rd to the 18th day. Engorged nymphs were collected, allowed to molt to adults in an incubator. Thereafter, the subsequent flat ticks were tested by PCR. All G1 and G2 capybaras became infected by R. rickettsii, as demonstrated by guinea pig inoculation and seroconversion, but they showed no fever. Rickettsemia was continually detected from the 6th (G2 capybaras) or 9th (G1 capybaras) to the 18th day post inoculation or infestation with R. rickettsii-infected ticks. A total of 20-25% and 30-35% of the flat ticks previously fed on G1 and G2 capybaras, respectively, became infected by R. rickettsii. The study demonstrated that R. rickettsii was capable to infect capybaras without causing clinical illness, inducing rickettsemia capable to cause infection in guinea pigs and ticks. Our results indicate that capybaras act as amplifier host of R. rickettsii for A. cajennense ticks in Brazil. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
Until the year 2000, only three Rickettsia species were known in South America: (i) Rickettsia rickettsii, transmitted by the ticks Amblyomma cajennense, and Amblyomma aureolatum, reported in Colombia, Argentina, and Brazil, where it is the etiological agent of Rocky Mountain spotted fever; (ii) Rickettsia prowazekii, transmitted by body lice and causing epidemic typhus in highland areas, mainly in Peru; (iii) Rickettsia typhi, transmitted by fleas and causing endemic typhus in many countries. During this new century, at least seven other rickettsiae were reported in South America: Rickettsia felis infecting fleas and the tick-associated agents Rickettsia parkeri, Rickettsia massiliae, Candidatus ""Rickettsia amblyommii,"" Rickettsia bellii, Rickettsia rhipicephali, and Candidatus ""Rickettsia andeanae. "" Among these other rickettsiae, only R. felis, R. parkeri and R. massiliae are currently recognized as human pathogens. R. rickettsii is a rare agent in nature, infecting : <= 1% individuals in a few tick populations. Contrastingly, R. parkeri, Candidatus ""R. amblyommii, "" R. rhipicephali, and R. bellii are usually found infecting 10 to 100% individuals in different tick populations. Despite rickettsiae being transmitted transovarially through tick generations, low infection rates for R. rickettsii are possibly related to pathogenic effect of R. rickettsii for ticks, as shown for A. aureolatum under laboratory conditions. This scenario implies that R. rickettsii needs amplifier vertebrate hosts for its perpetuation in nature, in order to create new lines of infected ticks (horizontal transmission). In Brazil, capybaras and opossums are the most probable amplifier hosts for R. rickettsii, among A. cajennense ticks, and small rodents for A. aureolatum.
Resumo:
This paper presents the characterization of single-mode waveguides for 980 and 1550 nm wavelengths. High quality planar waveguide structure was fabricated from Y(1-x)Er(x)Al(3)(BO(3))(4) multilayer thin films with x = 0.02, 0.05, 0.1, 0.3, and 0.5, prepared through the polymeric precursor and sol-gel methods using spin-coating. The propagation losses of the planar waveguides varying from 0.63 to 0.88 dB/cm were measured at 632.8 and 1550 nm. The photoluminescence spectra and radiative lifetimes of the Er(3+) (4)I(13/2) energy level were measured in waveguiding geometry. For most samples the photoluminescence decay was single exponential with lifetimes in between 640 mu s and 200 mu s, depending on the erbium concentration and synthesis method. These results indicate that Er doped YAl(3)(BO(3))(4) compounds are promising for low loss waveguides. (C) 2009 Elsevier B.V. All fights reserved.
Resumo:
We show how a circuit analysis, used widely in electrical engineering, finds application to problems of light wave injection and transport in subwavelength structures in the optical frequency range. Lumped circuit and transmission-line analysis may prove helpful in the design of plasmonic devices with standard, functional properties.