42 resultados para barrier integrity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the time-variant reliability analysis of structures with random resistance or random system parameters. It deals with the problem of a random load process crossing a random barrier level. The implications of approximating the arrival rate of the first overload by an ensemble-crossing rate are studied. The error involved in this so-called ""ensemble-crossing rate"" approximation is described in terms of load process and barrier distribution parameters, and in terms of the number of load cycles. Existing results are reviewed, and significant improvements involving load process bandwidth, mean-crossing frequency and time are presented. The paper shows that the ensemble-crossing rate approximation can be accurate enough for problems where load process variance is large in comparison to barrier variance, but especially when the number of load cycles is small. This includes important practical applications like random vibration due to impact loadings and earthquake loading. Two application examples are presented, one involving earthquake loading and one involving a frame structure subject to wind and snow loadings. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper was to study the main effects of the turning in the superficial integrity of the duplex stainless steel ASTM A890-6A. The tests were conducted on a turning centre with carbide tools and the main entrances variables were: tool material class, feed rate, cutting depth, cutting speed and cutting fluid utilisation. The answers were analysed: microstructural analysis by optical microscopy and x-ray diffraction, cutting forces measurements by a piezoelectric dynamometer, surface roughness, residual stress by x-ray diffraction technique and the microhardness measurements. The results do not show any changes in the microstructural of the material, even when the greater cutting parameters were used. The smaller feed rate (0.1 mm/v), smaller cutting speed (110 m/min) and the greater cutting depth (0.5 mm) provided the smaller values for the tensile residual stress, the smaller surface roughness and the greater microhardness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the effect of cerium (IV) ammonium nitrate (CAN) addition on the polymerization of bis-[triethoxysilyl]ethane (BTSE) film applied on carbon steel was studied. The electrochemical characterization of the films was carried out in 0.1 mol L(-1) NaCl solution by open-circuit potential measurements, anodic and cathodic polarization curves and electrochemical impedance spectroscopy (EIS). Morphological and chemical characterization were performed by atomic force microscopy (AFM), contact angle measurements, infrared-spectroscopy, nuclear magnetic resonance and thermogravimetric analysis. The results have clearly shown the improvement on the protective properties of the Ce(4+) modified film as a consequence of the formation of a more uniform and densely reticulated silane film. A mechanism is proposed to explain the accelerating role of Ce(4+) ions on the cross-linking of the silane layer. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To improve the surface characteristics of epoxy resin coatings, a treatment by fluorine-containing plasma was used to develop a coating with low surface free energy and improved chemical resistance. Through the coating analysis it was possible to verify information about the CF(n) bond formation and the fluorination depth. The best plasma process parameters presented the best fluorination depth, 90 nm, and fluorine concentration was nearly 30%. The improvement in contact angle of water was 50% and of raw petroleum was 130%. Salt spray test proves that the coating fluorination decreases the chance of substrate corrosion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing adoption of information systems in healthcare has led to a scenario where patient information security is more and more being regarded as a critical issue. Allowing patient information to be in jeopardy may lead to irreparable damage, physically, morally, and socially to the patient, potentially shaking the credibility of the healthcare institution. Medical images play a crucial role in such context, given their importance in diagnosis, treatment, and research. Therefore, it is vital to take measures in order to prevent tampering and determine their provenance. This demands adoption of security mechanisms to assure information integrity and authenticity. There are a number of works done in this field, based on two major approaches: use of metadata and use of watermarking. However, there still are limitations for both approaches that must be properly addressed. This paper presents a new method using cryptographic means to improve trustworthiness of medical images, providing a stronger link between the image and the information on its integrity and authenticity, without compromising image quality to the end user. Use of Digital Imaging and Communications in Medicine structures is also an advantage for ease of development and deployment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel algorithm to successfully achieve viable integrity and authenticity addition and verification of n-frame DICOM medical images using cryptographic mechanisms. The aim of this work is the enhancement of DICOM security measures, especially for multiframe images. Current approaches have limitations that should be properly addressed for improved security. The algorithm proposed in this work uses data encryption to provide integrity and authenticity, along with digital signature. Relevant header data and digital signature are used as inputs to cipher the image. Therefore, one can only retrieve the original data if and only if the images and the inputs are correct. The encryption process itself is a cascading scheme, where a frame is ciphered with data related to the previous frames, generating also additional data on image integrity and authenticity. Decryption is similar to encryption, featuring also the standard security verification of the image. The implementation was done in JAVA, and a performance evaluation was carried out comparing the speed of the algorithm with other existing approaches. The evaluation showed a good performance of the algorithm, which is an encouraging result to use it in a real environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Edge effects resulting from isolation and subsequent microclimatic changes are one of the most important threats to the forest fragments conservation. The efficiency of maintaining a barrier formed by three rows of Eucalyptus along the edge of a subtropical seasonal semi deciduous forest fragment, surrounded by Eucalyptus monoculture, was evaluated as a way of softening the microclimatic changes (light intensity, temperature and relative humidity) and the impacts of eucalypt mechanized harvesting on the native vegetation along the contact zone between the forest fragment and the plantation. The Eucalyptus barrier was effective in softening the microclimate. Light intensity was 35% lower in the presence of the barrier. The barrier also provided a reduction of 1 C in air temperature and increased in 3.4% in relative humidity throughout the year. The barrier was also effective in preventing the impact on native vegetation, avoiding damage to adult trees and preserving the regenerating forest stratum near the border, which was reduced to less than 20% in density and 50% in richness, with no such barrier. The barrier of Eucalyptus may, therefore, be recommended as an effective method to minimize the impacts of mechanized forest harvesting operations and mitigate the microclimatic conditions along the edge of forest fragments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryopreservation of parathyroid tissue is used in the surgical treatment of secondary hyperparathyroidism. After surgical resection, the tissue is temporarily maintained in a cell culture solution until it arrives at the specialized laboratory where the cryopreservation process will take place. The present study evaluates the time that the human hyperplastic parathyroid gland tissue can wait before cryopreservation, based on parathyroid cell ultrastructural integrity. This prospective study included 11 patients who underwent total parathyroidectomy with heterotopic autotransplantation and cryopreservation of parathyroid tissue fragments. Part of the tissue was kept in cell culture solution at 4A degrees C. Five time periods between 2 and 24 h were defined, and parathyroid fragments were kept in the solution for that length of time. At the end of each period, the fragments were removed from the transport solution, fixed, and prepared for ultrathin sections. Of the 11 cases studied, 10 showed ultrastructural findings consistent with cellular viability in tissue fragments that remained in the transport solution up to 12 h. Electron microscopy revealed that cell adhesion and the integrity of plasma membranes, nuclei, and mitochondria were preserved in one case for up to 24 h. Changes in mitochondrial structure represented the most constant ultrastructural damage seen in the cases studied, in addition to the presence of edema and cell vacuoles. Analysis of the ultrastructure of hyperplastic parathyroid gland tissue showed that ultrastructural integrity was in most cases properly maintained in fragments stored up to 12 h in a cell culture solution at 4A degrees C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Hydration and integrity of the horny layer is essential to normal skin function. Objective: Comparison of the hydrating properties of three moisturizers with pimecrolimus cream vehicle. Methods: Four test preparations (high-quality skin cream, cold cream emulsion, emollient oil, pimecrolimus cream vehicle) were applied to four different regions of the forearms and legs. Transepidermal water loss (TEWL) was assessed by evaporimetry at baseline, and 3 and 6 hours after arm application, and electrical capacitance was assessed by corneometry at baseline, and 1, 2, 3 and 6 hours after leg application. Results: Corneometry assessment - in terms of efficacy in moisturizing the skin, test preparations were ranked (best to worst): high-quality skin cream (45.9 arbitrary units versus 75.3; p < 0.001) > pimecrolimus vehicle cream (46.6 versus 61.5; p < 0.001) > emollient oil (43.5 versus 54.8; p = 0.006) > cold cream emulsion (44.8 versus 49.9; p = 0.738). Untreated skin (control) had a mean capacitance of 44.8 units at baseline and 48.5 units at endpoint. Evaporimetry (assessment of TEWL) revealed no significant differences between control and any test preparation at any timepoint. Conclusions: Pimecrolimus cream vehicle has skin hydration properties comparable with highly effective commercially available products. No test preparation had a significant effect on TEWL.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to investigate the differential ALCAM, ICAM-1 and VCAM-1 adhesion molecules mRNA expression and the blood-brain barrier (BBB) permeability in C57BL/6 and BALB/c mice in Toxoplasma gondii infection, animals were infected with ME-49 strain. It was observed higher ALCAM on day 9 and VCAM-1 expression on days 9 and 14 of infection in the central nervous system (CNS) of C57BL/6 compared to BALB/c mice. The expression of ICAM-1 was high and similar in the CNS of both lineages of infected mice. In addition, C57BL/6 presented higher BBB permeability and higher IFN-gamma and iNOS expression in the CNS compared to BALB/c mice. The CNS of C578L/6 mice presented elevated tissue pathology and parasitism. In conclusion, our data suggest that the higher adhesion molecules expression and higher BBB permeability contributed to the major inflammatory cell infiltration into the CNS of C57BL/6 mice that was not efficient to control the parasite. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/aims To compare two intraocular irrigating solutions, Balanced Salt Solution Plus (BSS Plus) versus Lactated Ringer`s (Ringer), for the preservation of corneal integrity after phacoemulsification. Methods 110 patients undergoing phacoemulsification were randomised to either BSS Plus (n = 55) or Ringer (n = 55) as the irrigating solution. Patients were examined at baseline and at 1, 8, 15, 30 and 60 days postoperatively. Evaluations included specular microscopy to evaluate endothelial cell density (ECD) and endothelial cell size variability (CV), and corneal pachymetry for central corneal thickness (CCT) measurement. Results Groups were well balanced regarding baseline ECD, CV and CCT (p>0.05). There was no statistically significant difference between ECD reduction in group BSS Plus 13.1 +/- 2.0% and Ringer 9.2 +/- 1.9% (p<0.05) at day 60 or in any study visit. There was no statistically significant difference between CV increase in group BSS Plus 23.0 +/- 3.0% and Ringer 20.2 +/- 4.0% (p<0.05) at day 60 or in any study visit. CCT was significantly increased (p<0.05) at 1, 8, 15 and 30 days postoperatively, returning to baseline at 60 days in both groups. There was no significant difference in CCT increase in both groups at any visit. Interestingly, there were statistically significant correlations between ECD loss and phacoemulsification time (p<0.0001) and ECD loss and irrigation solution volume (p<0.0001) in the Ringer group, but not in the BSS Plus group. Conclusions Ringers solution was similar to BSS Plus for corneal preservation in atraumatic cataract surgery. However, our study demonstrates that there is a trend towards lower postoperative endothelial cell density for surgeries with longer phacoemulsification time and higher irrigation volumes if Ringer is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contents This study aimed to evaluate the effect of the exogenous recombinant bovine somatotropin (rbST) on plasma concentrations of insulin-like growth factor I (IGF-I), insulin and semen quality of bulls. Twenty bulls (Aberdeen Angus and Brangus) were divided by breed into two groups. Placebo group was injected with NaCl 0.9% (s.c.) and treatment group with rbST (s.c., 500 mg) at days 0 and 14 of the experiment. Immediately after semen collection, blood samples were taken on days 0, 14, 28, 42 and 56 of the experiment. Semen was also collected on day 70 of the experiment. Evaluation of sperm motility was performed at pre-freezing and post-thawing stage, whereas assessment of sperm membrane integrity was performed after freezing and thawing. Analysis of data revealed that the effect of treatment and treatment-by-collection day on plasma concentrations of IGF-I and insulin was not significant. However, mean plasma concentrations of IGF-I and insulin were affected (p < 0.0001) by days of blood sampling. Effect of treatment and treatment-by-collection day on motility of spermatozoa was similar (p > 0.05) at pre-freezing and post-thawing stage. Intactness of plasmalemma and tail membrane of spermatozoa at post-thawing stage was higher (p < 0.05) in rbST-treated group than in control. In conclusion, rbST did not affect plasma concentrations of IGF-I and insulin, however, it did improve post-thaw sperm membrane integrity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple, rapid and stable sperm evaluation methods which have been optimized for common marmoset (Callithrix jacchus) are critical for studies involving collection and evaluation of sperm in the field. This is particularly important for new species groups such as Callitrichidae where the sperm have been little studied. Of this family, C jacchus is the best known, and has been chosen as a model species for other members of the genus Callithrix. The fundamental evaluation parameters for sperm of any species are viability and acrosomal status. Semen samples were collected by penile vibratory stimulation. To evaluate sperm plasma membrane integrity, Eosin-Nigrosin was tested here for the common marmoset sperm to be used under field conditions. Further, a non-fluorescent stain for acrosome, the ""Simple"" stain, developed for domestic and wild cats, was tested on common marmoset sperm. This was compared with a fluorescent staining, Fluorescein isothiocyanate-Pisum sativum agglutinin (FITC-PSA), routinely used and validated for common marmoset at the German Primate Centre to evaluate acrosomal integrity. Results obtained with the ""Simple"" stain showed a marked differentiation between sperm with intact and non-intact acrosome both with and without ionophore treatment and closely correlated with results obtained with FITC-PSA. Temperature had no effect on the results with the ""Simple"" stain and the complete processing is simple enough to be carried out under field conditions. These findings indicated that the ""Simple"" stain and Eosin-Nigrosin provide rapid and accurate results for C. jacchus sperm and that those methods can be reliably used as field tools for sperm evaluation for this species. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To test the null hypothesis that continuity of resin cement/dentin interfaces is not affected by location along the root canal walls or water storage for 3 months when bonding fiber posts into root canals. Methods. Fiber posts were luted to bovine incisors using four resinous luting systems: Multilink, Variolink II, Enforce Dual and Enforce PV. After cementation, roots were longitudinally sectioned and epoxy resin replicas were prepared for SEM analysis (baseline). The original halves were immersed in solvent, replicated and evaluated. After 3 months water storage and a second solvent immersion, a new set of replicas were made and analyzed. The ratio (%) between the length (mm) of available bonding interface and the actual extension of bonded cement/dentin interface was calculated. Results. Significant lower percent values of bond integrity were found for Multilink (8.25%) and Variolink 11 (10.08%) when compared to Enforce Dual (25.11%) and Enforce PV (27.0%) at baseline analysis. The same trend was observed after immersion in solvent, with no significant changes. However, bond integrity was significantly reduced after 3 months water storage and a second solvent immersion to values below 5% (Multilink = 3.31%, Variolink=1.87%, Enforce Dual=1.20%, and Enforce PV=0.75%). The majority of gaps were depicted at the apical and middle thirds at baseline and after immersion in solvent. After 3 months, gaps were also detected at the cervical third. Significance. Bond integrity at the cement/dentin interface was surprisingly low after cementation of fiber posts to root canals with all resin cements. That was not significantly altered after immersion in solvent, but was further compromised after 3 months water storage. Gaps were mainly seen at middle and apical thirds throughout the experiment and extended to the cervical third after water storage for 3 months. Bond integrity of fiber posts luted to root canals was affected both by location and water storage. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.