32 resultados para Oblique Gaze,
Resumo:
Background: The use of synthetic mesh for abdominal wall closure after removal of the rectus abdominis is established but not standardised. This study compares two forms of mesh fixation: a simple suture, which fixes the mesh to the edges of the defect on the anterior rectus abdominis fascia; and total fixation, which incorporates the fasciae of the internal oblique, external oblique and transverse muscles in the suture, anchoring the mesh in the position of the removed muscle. Method: A total of 16 fresh cadavers were dissected. Two sutures were compared: simple and total. Three different sites were analysed: 5 cm above, 5 cm below and at the level of the umbilicus. The two sutures compared were tested in each region using a standardised technique. All sutures were performed with nylon 0, perpendicular to the linea alba. Each suture was secured to a dynamometer, which was pulled perpendicularly towards the midline until the rupture of the aponeurosis. `Rupture resistance` was measured in kilogram force. The mean among the groups was compared using the paired Student`s t-test to a significance level of 1% (p < 0.01). Results: The mean rupture resistance of the total suture was 160% higher than that of the simple suture. Conclusion: The total suture includes the external oblique, internal oblique and transverse fasciae, which are multi-directional, and creates a much higher resistance when compared with the simple suture. Total suture may reduce the incidence of bulging and hernias of the abdominal wall after harvesting the rectus abdominis muscle, but comparative clinical studies are necessary. (C) 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Resumo:
Queiroz BC, Cagliari MF, Amorim CF, Sacco IC. Muscle activation during four Pilates core stability exercises in quadruped position. Arch Phys Med Rehabil 2010;91: 86-92. Objective: To compare the activity of stabilizing trunk and hip muscles in 4 variations of Pilates stabilizing exercises in the quadruped position. Design: Repeated-measures descriptive study. Setting: A biomechanics laboratory at a university school of medicine. Participants: Healthy subjects (N=19; mean age +/- SD, 31 +/- 5y; mean weight +/- SD, 60 +/- 11 kg; mean height +/- SD, 166 +/- 9cm) experienced in Pilates routines. Interventions: Surface electromyographic signals of iliocostalis, multifidus, gluteus maximus, rectus abdominis, and external and internal oblique muscles were recorded in 4 knee stretch exercises: retroverted pelvis with flexed trunk; anteverted pelvis with extended trunk; neutral pelvis with inclined trunk; and neutral pelvis with trunk parallel to the ground. Main Outcome Measures: Root mean square values of each muscle and exercise in both phases of hip extension and flexion, normalized by the maximal voluntary isometric contraction. Results: The retroverted pelvis with flexed trunk position led to significantly increased external oblique and gluteus maximus muscle activation. The anteverted pelvis with trunk extension significantly increased multifidus muscle activity. The neutral pelvis position led to significantly lower activity of all muscles. Rectus abdominis muscle activation to maintain body posture was similar in all exercises and was not influenced by position of the pelvis and trunk. Conclusions: Variations in the pelvic and trunk positions in the knee stretch exercises change the activation pattern of the multifidus, gluteus maximus, rectus abdominis, and oblique muscles. The lower level of activation of the rectus abdominis muscle suggests that pelvic stability is maintained in the 4 exercise positions.
Resumo:
Patella stabilizer muscle response and patellar kinematics were evaluated in 19 women with anterior knee pain (AKP) and 20 healthy women during maximum voluntary isometric contraction (MVIC) with the knee positioned at 15 degrees, 30 degrees and 45 degrees flexion during open (OKC) and closed (CKC) kinetic chain exercises. Patellar kinematics was evaluated through patellar tilt and displacement, and the electrical activity of patellar stabilizers through the root mean square normalized during MVIC and OKC with the knee at 90 degrees flexion. Data revealed that the vastus medialis oblique muscle (VMO) was more active in the control group compared to the AKP group during OKC exercises with the knee at 45 degrees flexion. However, no difference in the patellar kinematics was observed between these groups; nevertheless, the correlation between these parameters also showed, with the knee at 45 degrees flexion, that lateral patellar tilt increase was associated with a reduction in the activity of lateral patellar stabilizers in the control group and with an increase in the VMO activity in the AKP group. In conclusion, electrical activity is an important factor in evaluating AKP and in AKP treatment evolution. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Objective: To asses the onset (%) of patella stabilizer muscles during maximal isometric contraction exercises (MIC) in individuals with and without signs of patellofemoral pain syndrome (PFPS) in open (OKC) and closed (CKC) kinetic chain exercises, Method: Assessments were carried out on 22 women; ten with no complains of anterior knee pain, and 12 with PFPS signs during MIC in OKC and CKC with the knee flexed at 90 degrees. The onset of the electromyographic activity of the vastus mediallis obliquus (VMO), vastus lateralis obliquus (VLO) and vastus lateralis longus (VLL) was identified by means of an algorithm in the Myosystem Br 1 software. The statistical analysis used was Chi-Square test and student`s t test, which are both tests with a level of significance at 5%. Results: The VMO and VLO muscles presented a greater onset compared to the VLL during OKC exercises for both groups and for the PFPS group without CCF No differences were observed between the groups. Conclusion: CKC and OKC exercises seem to benefit the synchronism of the musculature that supposedly benefits the patella stabilizer musculature, and can be recommended in physiotherapeutic treatment programs.
Resumo:
In this paper, methods are presented for automatic detection of the nipple and the pectoral muscle edge in mammograms via image processing in the Radon domain. Radon-domain information was used for the detection of straight-line candidates with high gradient. The longest straight-line candidate was used to identify the pectoral muscle edge. The nipple was detected as the convergence point of breast tissue components, indicated by the largest response in the Radon domain. Percentages of false-positive (FP) and false-negative (FN) areas were determined by comparing the areas of the pectoral muscle regions delimited manually by a radiologist and by the proposed method applied to 540 mediolateral-oblique (MLO) mammographic images. The average FP and FN were 8.99% and 9.13%, respectively. In the detection of the nipple, an average error of 7.4 mm was obtained with reference to the nipple as identified by a radiologist on 1,080 mammographic images (540 MLO and 540 craniocaudal views).
Resumo:
Purpose: To describe a patient with Tessier cleft number 5 and 9 and review the literature on the ocular impairment and management of this extremely rare anomaly. Methods: Interventional case report and literature review. Results: The literature review showed that the present patient is the second case with clefts 5/9. The ophthalmic consequences of this rare association are virtually unreported. Our case demonstrates that the presence of cleft number 9 adds a cicatricial component on the upper eyelid that severely impairs the dynamics of this lid. The corneal status of the patient was successfully managed with simultaneous upper eyelid lengthening and facial reconstruction. Conclusion: In order to avoid corneal perforation, simultaneous upper and lower eyelid reconstruction is mandatory in cases of cleft 5/9. The affected patients should be continuously followed in order to prevent amblyopia.
Resumo:
Purpose: To describe spontaneous blink kinematics in Graves` upper eyelid retraction (UER). Methods: The magnetic search coil technique was used to record spontaneous blinks of 15 healthy subjects (aged 23-56 years, 15 eyelids) and 15 patients with Graves` UER (aged 22-62 years, 15 eyelids) during a 5-min period of video observation, and the signals were digitized at 200 Hz (12 bits). Overall, a total of 2,798 blinks were recorded for the controls and 1,860 for the patients. The distance between pupil center and upper eyelid margin in the primary position of gaze (MRD) was measured with the Image J software. Results: The blinking rate of patients was lower than that of control subjects, with a mean (+/-SEM) blinking rate (blinks/min) of 13.0 +/- 1.7 for patients and of 20.0 +/- 2.1 for the controls (t = 2.58, P = 0.016). There were no statistically significant differences in blink amplitude between controls (22.7 +/- 3.1 degrees) and Graves` patients (24.7 +/- 3.3 degrees). However, while only 22% of the blinks performed by controls were smaller than MRD, this rate was 78% for patients. In addition, in blinks larger than 25, patients showed lower down-phase velocity than controls. Conclusions: Patients with Graves` UER show reduced blinks rates and abnormal blink kinematics, which might be related to the development of exposure keratitis in this disease.
Resumo:
The current study describes the morphologic macular features in two eyes that developed full-thickness macular holes in the setting of documented vitreofoveal separation. Using third-generation optical coherence tomography, complete vitreofoveal separation associated with the disruption of the inner foveal retina was documented in both cases. Five months after presentation, decreased vision and epiretinal membrane formation associated with development of a full-thickness macular hole were observed in the first patient. In the second patient, a full-thickness macular hole was demonstrated by optical coherence tomography 6 weeks after presentation. These findings suggest that full-thickness macular holes may develop in eyes with vitreofoveal separation. Evidence of the disturbance of the inner foveal architecture on optical coherence tomography indicates the potential role of factors other than anteroposterior or oblique vitreoretinal tractional forces in the genesis of some full-thickness macular holes.
Resumo:
PURPOSE. To determine the shape of spontaneous interblink time interval distributions obtained in a long observation period in normal subjects and patients with Graves` orbitopathy. METHODS. The magnetic search coil technique was used to register the spontaneous blinking activity during 1 hour of video observation of two groups of 10 subjects each (normal controls aged 27-61 years, mean +/- SD = 46.0 +/- 13.6; patients with Graves` orbitopathy aged 33-61 years, mean +/- SD +/- 46.7 +/- 8.9). The spontaneous blink rate of each subject was calculated for the entire period of observation and for 56 five-minute bins. Histograms of the interblink time interval were plotted for each measurement of blink rate. RESULTS. Neither the overall mean blink rate (controls, 19.8 +/- 4.9; Graves`, 17.6 +/- 5.4) nor the interblink time (controls, 5.2 +/- 3.1, Graves`, 7.9 +/- 3.5) differed between the two groups. There was a large variation of both measurements when the 5-minute bins were considered. The interblink time distribution of all subjects was highly positively skewed when the 1-hour period was measured. A significant number of the 5-minute bin distributions deviated from the overall pattern and became symmetric. CONCLUSIONS. The normal blinking process is characterized by highly positively skewed interblink time distributions. This result means that most blinks have a short time interval, and occasionally a small number of blinks have long time intervals. The different patterns of distribution described in the early literature probably represent artifacts because of the small samples analyzed. (Invest Ophthalmol Vis Sci. 2011;52:3419-3424) DOI:10.1167/iovs.10-7060
Resumo:
This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 2010
Resumo:
Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.
Resumo:
Objectives: The aims of this study were to evaluate the visibility of the lateral pterygoid muscle (LPM) in temporomandibular joint (TMJ) images obtained by MRI, using different projections and to compare image findings with clinical symptoms of patients with and without temporomandibular disorders (TMD). Methods: In this study, LPM images of 50 participants with and without TMDs were investigated by MRI. The images of the LPM in different projections of 100 TMJs from 35 participants (70 TMJs) with and 15 participants (30 TMJs) without clinical signs and symptoms of TMD were visible and analysed. Results: The oblique sagittal and axial images of the TMJ clearly showed the LPM. Hypertrophy (1.45%), atrophy (2.85%) and contracture (2.85%) were the abnormalities found in the LPM. TMD signs, such as hypermobility (11.4%), hypomobility (12.9%) and disc displacement (20.0%), could be seen in TMJ images. Related clinical symptoms, such as pain (71.4%), articular sounds (30.4%), bruxism (25.7%) and headache (22.9%), were observed. Conclusions: Patients with TMD can present with alterations in the LPM thickness. Patients without TMD also showed alterations, such as atrophy and contracture, in TMJ images. Recognition of alterations in the LPM will improve our understanding of clinical symptoms and pathophysiology of TMD, and may lead to a more specific diagnosis of these disorders. Dentomaxillofacial Radiology (2010) 39, 494-500. doi: 10.1259/dmfr/80928433
Resumo:
Purpose: The objective of this study was to evaluate the stress on the cortical bone around single body dental implants supporting mandibular complete fixed denture with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent). Methods and Materials: Stress levels on several system components were analyzed through finite element analysis. Focusing on stress concentration at cortical bone around single body dental implants supporting mandibular complete fixed dentures with rigid ( Neopronto System-Neodent) or semirigid splinting system ( Barra Distal System-Neodent), after axial and oblique occlusal loading simulation, applied in the last cantilever element. Results: The results showed that semirigid implant splinting generated lower von Mises stress in the cortical bone under axial loading. Rigid implant splinting generated higher von Mises stress in the cortical bone under oblique loading. Conclusion: It was concluded that the use of a semirigid system for rehabilitation of edentulous mandibles by means of immediate implant-supported fixed complete denture is recommended, because it reduces stress concentration in the cortical bone. As a consequence, bone level is better preserved, and implant survival is improved. Nevertheless, for both situations the cortical bone integrity was protected, because the maximum stress level findings were lower than those pointed in the literature as being harmful. The maximum stress limit for cortical bone (167 MPa) represents the threshold between plastic and elastic state for a given material. Because any force is applied to an object, and there is no deformation, we can conclude that the elastic threshold was not surpassed, keeping its structural integrity. If the force is higher than the plastic threshold, the object will suffer permanent deformation. In cortical bone, this represents the beginning of bone resorption and/or remodeling processes, which, according to our simulated loading, would not occur. ( Implant Dent 2010; 19:39-49)
Resumo:
Kidney transplantation improves the quality of life of end-stage renal disease patients. The quality of life benefits, however, pertain to patients on average, not to all transplant recipients. The aim of this study was to identify factors associated with health-related quality of life after kidney transplantation. Population-based study with a cross-sectional design was carried out and quality of life was assessed by SF-36 Health Survey Version 1. A multivariate linear regression model was constructed with sociodemographic, clinical and laboratory data as independent variables. Two hundred and seventy-two kidney recipients with a functioning graft were analyzed. Hypertension, diabetes, higher serum creatinine and lower hematocrit were independently and significantly associated with lower scores for the SF-36 oblique physical component summary (PCSc). The final regression model explained 11% of the PCSc variance. The scores of oblique mental component summary (MCSc) were worse for females, patients with a lower income, unemployed and patients with a higher serum creatinine. The regression model explained 9% of the MCSc variance. Among the studied variables, comorbidity and graft function were the main factors associated with the PCSc, and sociodemographic variables and graft function were the main determinants of MCSc. Despite comprehensive, the final regression models explained only a little part of the heath-related quality of life variance. Additional factors, such as personal, environmental and clinical ones might influence quality of life perceived by the patients after kidney transplantation.
Resumo:
The purpose of this study is to evaluate the influence of the undermining of the subcutaneous tissue on the tension of the abdominal wall, after the components separation of the abdominal muscles. Twenty adult cadavers were studied. The resistance of the medial advancement of both anterior and posterior recti sheaths was represented by the traction index and measured in 2 levels-3 cm above and 2 cm below the umbilicus. Traction indices were compared in the following 3 consecutive dissection situations: (1) after the subcutaneous tissue undermining laterally to the semilunaris line; (2) after the dissection of the rectus muscle from its posterior sheath associated with the release of the external oblique muscle; (3) after the subcutaneous tissue undermining laterally to the anterior axillary line. Friedman and Spearman tests were used to compare the results. There was no statistical significant difference between the subcutaneous tissue undermining laterally to the semilunaris line and that laterally to the anterior axillary line, when associated with the musculoaponeurotic dissections. In conclusion, limited subcutaneous undermining does not influence the tension of closure of the musculoaponeurotic layer after the components separation technique in cadavers.