21 resultados para Market and Buyer confidence
Resumo:
The bioequivalence of two different tablet formulations of tirtidazole (CAS 19387-91-8) was determined in healthy volunteers after a single dose in a randomized crossover study, with a 1-week washout period between the doses. Reference and test products were administered to 24 volunteers with 240 mL water after overnight fasting. Plasma concentrations of tinidazole were monitored by a high-performance liquid chromatographic method (HPLC) over a period of 72 h after the administration. The pharmacokinetic parameters AUC(0-t), AUC(0-infinity), C(max), T(max), T((1/2)el) and beta were determined from plasma concentration time profile of both formulations and found to be in good agreement with previously reported values. The calculated pharmacokinetic parameters were compared statistically to evaluate bioequivalence between the two brands. The analysis of variance (ANOVA) did not show any significant difference between the two formulations and 90% confidence intervals for the ratio of C(max) (93.9 - 102.6%), AUC(0-t), (94.9-101.1%) and AUC(0-infinity) (94.6-100.8%) values for the test and reference products were within the 80 - 125% interval, satisfying bioequivalence criteria of the European Committee for Proprietary Medicinal Products and the US Food and Drug Administration Guidelines. These results indicate that the test and the reference products of tinidazole are bioequivalent and, thus, may be prescribed interchangeably.
Resumo:
Background: There is a paucity of information describing the real-time 3-dimensional echocardiography (RT3DE) and dyssynchrony indexes (DIs) of a normal population. We evaluate the RT3DE DIs in a population with normal electrocardiograms and 2- and 3-dimensional echocardiographic analyses. This information is relevant for cardiac resynchronization therapy. Methods: We evaluated 131 healthy volunteers (73 were male, aged 46 +/- 14 years) who were referred for routine echocardiography; who presented normal cardiac structure on electrocardiography, 2-dimensional echocardiography, and RT3DE; and who had no history of cardiac diseases. We analyzed 3-dimensional left ventricular ejection fraction, left ventricle end-diastolic volume, left ventricle end-systolic volume, and left ventricular systolic DI% (6-, 12-, and 16-segment models). RT3DE data were analyzed by quantifying the statistical distribution (mean, median, standard deviation [SD], relative SD, coefficient of skewness, coefficient of kurtosis, Kolmogorov-Smirnov test, D`Agostino-Pearson test, percentiles, and 95% confidence interval). Results: Left ventricular ejection fraction ranged from 50% to 80% (66.1% +/- 7.1%); left ventricle end-diastolic volume ranged from 39.8 to 145 mL (79.1 +/- 24.9 mL); left ventricle end-systolic volume ranged from 12.9 to 66 mL (27 +/- 12.1 mL); 6-segment DI% ranged from 0.20% to 3.80% (1.21% +/- 0.66%), median: 1.06, relative SD: 0.5482, coefficient of skewness: 1.2620 (P < .0001), coefficient of Kurtosis: 1.9956 (P = .0039); percentile 2.5%: 0.2900, percentile 97.5%: 2.8300; 12-segment DI% ranged from 0.22% to 4.01% (1.29% +/- 0.71%), median: 1.14, relative SD: 0.95, coefficient of skewness: 1.1089 (P < .0001), coefficient of Kurtosis: 1.6372 (P = .0100), percentile 2.5%: 0.2850, percentile 97.5%: 3.0700; and 16-segment DI% ranged from 0.29% to 4.88% (1.59 +/- 0.99), median: 1.39, relative SD: 0.56, coefficient of skewness: 1.0792 (P < .0001), coefficient of Kurtosis: 0.9248 (P = .07), percentile 2.5%: 0.3750, percentile 97.5%: 3.750. Conclusion: This study allows for the quantification of RT3DE DIs in normal subjects, providing a comparison for patients with heart failure who may be candidates for cardiac resynchronization therapy. (J Am Soc Echocardiogr 2008; 21: 1229-1235)
Resumo:
There are scarce data about headache prevalence and its characteristics among elderly people. The aim was to carry out a cross-sectional study to determine the 1-year prevalence of tension-type and migraine headaches in people > 65 years old in the city of Sao Paulo, Brazil. All 1615 people living in the study catchment area who agreed to participate in the study answered a questionnaire based in the International Headache Society criteria. Prevalence (mean and 95% confidence interval) of any type of headache in the last year was 45.6% (43.2, 48.0). Prevalence of tension-type headache in the last year was 33.1% (30.8, 35.4): 28.1% (24.6, 31.6) for men and 36.4% (33.4, 39.4) for women; for migraine headaches, prevalence in the last year was 10.6% (9.1, 12.1): 5.1% (3.4, 6.8) for men and 14.1% (11.9, 16.3) for women. One-year prevalence rates of headaches, and especially of migraine headaches, are very high among the elderly in Brazil.
Resumo:
Objective To study increases in electromyographic (EMG) response from the right and left rectus femoris muscles of individuals with long-term cervical spinal cord injuries after EMG biofeedback treatment. Design Repeated measure trials compared EMG responses before and after biofeedback treatment in patients with spinal cord injuries. Main outcome measures The Neuroeducator was used to analyse and provide feedback of the EMG signal and to measure EMG response. Setting Department of Traumatic Orthopaedics, School of Medicine, University of Sao Paulo, Brazil. Participants Twenty subjects (three men and 17 women), between 21 and 49 years of age, with incomplete spinal cord injury at level C6 or higher (range C2 to C6). Of these subjects, 10 received their spinal cord injuries from motor vehicle accidents, one from a gunshot, five from diving, three from falls and one from spinal disc herniation. Results Significant differences were found in the EMG response of the right rectus femoris muscle between pre-initial (T1), post-initial (T2) and additional (T3) biofeedback treatment with the subjects in a sitting position [mean (standard deviation) T1: 26 mu V (29); T2: 67 mu V (50); T3: 77 mu V (62)]. The mean differences and 95% confidence intervals for these comparisons were as follows: T1 to T2, -40.7 (-53.1 to -29.4); T2 to T3, -9.6 (-26.1 to 2.3). Similar differences were found for the left leg in a sitting position and for both legs in the sit-to-stand condition. Conclusions The EMG responses obtained in this study showed that treatment involving EMG biofeedback significantly increased voluntary EMG responses from right and left rectus femoris muscles in individuals with spinal cord injuries. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Resumo:
Background: Risperidone (RSP) is a benzisoxazole antipsychotic agent used to treat schizophrenia and other psychiatric illnesses in adults and children (including those with autism). After oral administration, RSP is completely absorbed from the gastrointestinal tract and undergoes hydroxylation to yield 9-hydroxyrisperidone (9-OH-RSP), an active metabolite that has a pharmacologic profile and potency similar to RSP. Objectives: The aims of this study were to compare the relative bioavailability of a pharmaceutical-equivalent (test) formulation with a reference formulation of oral RSP 2 mg, both available commercially on the Brazilian pharmaceutical market, and to generate data regarding the oral bioavailability of the tested drug in healthy Brazilian volunteers. Methods: This single-dose, randomized-sequence, open-label, 2-period crossover study was conducted in healthy Brazilian volunteers from August to December 2008. Subjects were randomly assigned to receive the test formulation followed by the reference formulation or vice versa, with a 30-day washout period between doses. Study drugs were administered after a 12-hour overnight fast. For pharmacokinetic analysis, blood samples were drawn at 0 (baseline), 0.25, 0.5, 1, 1.5, 3, 5, 8, 12, 24, 48, 72, 96, and 120 hours after administration. Plasma concentrations of RSP and 9-OH-RSP were determined using LC-MS/MS. The test and reference formulations were to be considered bioequivalent if the 90% CIs for the geometric mean test/reference ratios were within a predetermined range of 80% to 125%, in accordance with the policies of the Brazilian Sanitary Surveillance Agency and the US Food and Drug Administration. Tolerability was determined using clinical assessments, monitoring of vital signs, analysis of laboratory test results, and subject interviews regarding adverse events. Results: A total of 22 subjects were enrolled (11 men, 11 women; mean [SD] age, 32 [12] years [range, 18-58 years]; weight, 70.4 [11.9] kg [range, 50-103 kg]; height, 1.67 [0.08] m [range, 1.56-1.80 m]; and body mass index, 25 [4] kg/m(2) [range, 18-29 kg/m(2)]). For RSP, mean (SD) C(max) values were 12.6 (2.7) and 16.0 (2.3) ng/mL for the test and reference formulations, respectively. For 9-OH-RSP, mean C(max) values were 17.8 (1.3) and 21.0 (1.7) ng/mL for the test and reference formulations. The 90% CIs for the mean test/reference ratios for RSP C(max), AUC(0-120), and AUC(0-infinity) were 74% to 82%, 75% to 85%, and 76% to 85%, respectively, and 83% to 87%, 75% to 79%, and 75% to 78% for 9-OH-RSP. The related adverse events (headache, low back pain, drowsiness, standing hypotension, local postvenipuncture ecchymoses, insomnia, nausea, and vomiting) were transient and mild. Conclusions: This single-dose study found that the test and reference formulations of oral RSP 2 mg did not meet the Brazilian and US regulatory criteria for bioequivalence in these fasting, healthy volunteers. The study formulations appeared to be well tolerated. (Clin Ther 2010;32:2106-2115) (C) 2010 Elsevier HS Journals, Inc.
Resumo:
Objective: To introduce a new coupling system between screw driver and interference screw, and biomechanical tests that validate the safety of its application. Methods: The new system was submitted to biomechanical torsion assays. Two types of analysis were performed: maximum torque of manual insertion of the screws into bovine bone; destructive assays of torsion of the system using an INSTRON 55MT machine. The same tests were also performed on a control group, using a commercially available interference screw coupling system (Acufex (R)). Results: In the tests on manual insertion of screws in bovine femurs, the average values found with a digital torque meter were 1.958 N/m for Acufex (R) and 2.563 N/m for FMRP. Considering p>0.05, there were no statistical differences between the two groups (p=0.02) in the values for maximum torque of insertion, in the two systems studied. The average values for maximum torque of torsion resisted by the screw were 15N/m for the Acufex (R) screw and 13N/m for the FMRP screw, again with no statistical differences between the two groups (p>0.05). In the evaluation of angular deformation, there was also no significant difference between the two screw types (p=0.15). Conclusion: The new coupling system for interference screws developed at FMRP-USP revealed a torsion resistance that is comparable with the system already available on the market and regulated for international use.