44 resultados para Intrasubject repeatability
Resumo:
The aim of this work is to propose a biomonitoring method for the simultaneous determination of Cd and Pb in whole blood by simultaneous electrothermal atomic absorption spectrometry for assessment of environmental levels. A volume of 200 mu L of whole blood was diluted in 500 mu L of 0.2% (w v(-1)) Triton(R) X-100 + 2.0% (v v(-1)) HNO3. Trichloroacetic acid was added for protein precipitation and the supernatant analyzed. A mixture of 250 mu g W + 200 mu g Rh as permanent and 2.0% (w v(-1)) NH4H2PO4 as co-injected modifiers were used. Characteristic masses and limits of detections (n = 20, 3s) for Cd and Pb were 1.26 and 33 pg and 0.026 mu g L-1 and 0.65 mu g L-1, respectively. Repeatability ranged from 1.8 to 6.8% for Cd and 1.2 to 1.7% for Pb. The trueness of method was checked by the analysis of three Reference Materials: Lyphocheck(R) Whole Blood Metals Control level 1 and Seronorm(TM) Trace Elements in Whole Blood levels 1 and 2. The found concentrations presented no statistical differences at the 95% confidence level. Blood samples from 40 volunteers without occupational exposure were analyzed and the concentrations ranged from 0.13 to 0.71 mu g L-1 (0.32 +/- 0.19 mu g L-1) for Cd and 9.3 to 56.7 mu g L-1 (25.1 +/- 10.8 mu g L-1) for Pb. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
UV-VIS-Spectrophotometric and spectrofluorimetric methods have been developed and validated allowing the quantification of chloroaluminum phthalocyanine (CIAIPc) in nanocarriers. In order to validate the methods, the linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and selectivity were examined according to USP 30 and ICH guidelines. Linearities range were found between 0.50-3.00 mu g.mL(-1) (Y=0.3829 X [CIAIPc, mu g.mL(-1)] + 0.0126; r=0.9992) for spectrophotometry, and 0.05-1.00 mu g.mL(-1) (Y=2.24 x 10(6) X [CIAIPc, mu g.L(-1)] + 9.74 x 10(4); r=0.9978) for spectrofluorimetry. In addition, ANOVA and Lack-of-fit tests demonstrated that the regression equations were statistically significant (p<0.05), and the resulting linear model is fully adequate for both analytical methods. The LOD values were 0.09 and 0.01 mu g.mL(-1), while the LOCI were 0.27 and 0.04 mu g.mL(-1) for spectrophotometric and spectrofluorimetric methods, respectively. Repeatability and intermediate precision for proposed methods showed relative standard deviation (RSD) between 0.58% to 4.80%. The percent recovery ranged from 98.9% to 102.7% for spectrophotometric analyses and from 94.2% to 101.2% for spectrofluorimetry. No interferences from common excipients were detected and both methods were considered specific. Therefore, the methods are accurate, precise, specific, and reproducible and hence can be applied for quantification of CIAIPc in nanoemulsions (NE) and nanocapsules (NC).
Resumo:
Plasma clearance of (51)Cr-EDTA ((51)Cr-EDTA-Cl) is an alternative method to evaluate glomerular filtration rate (GFR). This study aimed to investigate the concordance between (51)Cr-EDTA-Cl and renal inulin clearance (In-Cl) in renal transplant recipients as well to determine the repeatability of (51)Cr-EDTA-Cl in kidney donors. Forty four kidney recipients and 22 kidney donors were enrolled. Simultaneous measurements of (51)Cr-EDTA-Cl and In-Cl were performed. A single dose of 3.7MBq of (51)Cr-EDTA was injected and the plasma disappearance curve was created by taking blood samples at 2, 4, 6 and 8 h after injection. Bland and Altman statistical approach was used to quantify the agreement between In-Cl and (51)Cr-EDTA-Cl and to determine the better concordance between all possibilities of measure for the (51)Cr-EDTA-Cl. The mean of In-Cl was 44.5 +/- 17.9 ml/min/1.73 m(2). There was a positive correlation between In-Cl and all possible measurements of (51)Cr-EDTA-Cl. (51)Cr-EDTA-Cl with two samples taken at 4 and 8 h or at 4 and 6 h presenting the narrow limits of agreement and a difference (bias) of 2.8 and 2.7 ml/min, respectively. Two plasma sampling for (51)Cr-EDTA-Cl was a reliable method to measure GFR compared with In-Cl and comprises a suitable method to be used in kidney transplanted patients.
Resumo:
The authors developed an evaluation scale for sit-stand from the ground for children with Duchenne muscular dystrophy (DMD) and tested its reliability. The construction occurred in stages: (a) the characterization of the movement in healthy children, (b) the characterization of the movement in children with DMD, (c) the elaboration of the 1st version of the scale and the manual, (d) the evaluation by experts and readjustments, and (e) the analysis of inter- and intraexaminer reliability and correlation with the Vignos Scale, age, and time for the execution of the activity. The scale comprehended 3 phases for sitting and 5 for the standing. A very good repeatability of the measures of sitting and standing (ICC = 0.89 and 0.84, respectively) and excellent reproducibility (ICC = 0.93 and 0.92, respectively) was demonstrated. The Kappa coefficient for the 8 phases in the interexaminer analysis varied from 0.77 to 1.00 (excellent reliability), and in the intraexaminer analysis varied from 0.80 to 1.00 (excellent reliability). Good correlation was found between the variables on the Vignos Scale (age: r = 0.58; stand: r = 0.56). The scale is a reliability instrument that allows evaluation of the activity of sitting and standing in children with DMD.
Resumo:
The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Records of 18,770 Nelore animals, born from 1975 to 2002, in 8 herds participating in the Nelore Cattle Breeding Program, were analyzed to estimate genetic parameters for mature BW. The mature BW were analyzed as a single BW taken closest to 4.5 yr of age for each cow in the data file, considering BW starting from 2 (W2Y_S), 3 (W3Y_S), or 4 (W4Y_S) yr of age or as repeated records, including all BW starting from 2 (W2Y_R), 3 (W3Y_R), or 4 (W4Y_R) yr of age. The variance components were estimated by restricted maximum likelihood, fitting univariate and bivariate animal models, including weaning weight. The heritability estimates were 0.29, 0.34, 0.36, 0.41, 0.44, and 0.46 for W2Y_S, W3Y_S, W4Y_S, W2Y_R, W3Y_R, and W4Y_R, respectively. The repeatability estimates for W2Y_R, W3Y_R, and W4Y_R were 0.59, 0.64, and 0.72, respectively. Larger accuracy values associated with the EBV were obtained in the repeated records models. The results indicated the bivariate repeated records model as the most appropriate for analyzing mature BW.
Resumo:
It is difficult to precisely measure articular arc movement in newborns using a goniometer. This article proposes an objective method based on trigonometry for the evaluation of lower limb abduction. With the newborn aligned in the dorsal decubitus position, 2 points are marked at the level of the medial malleolus, one on the sagittal line and the other at the end of the abduction. Using the right-sided line between these 2 points and a line from the medial malleolus to the reference point at the anterior superior iliac spine or umbilical scar, an isosceles triangle is drawn, and half of the inferential abduction angle is obtained by calculating the sine. Twenty healthy full-term newborns comprise the study cohort. Intersubject and intrasubject variability among the abduction angle values (mean [SD], 37 degrees [4]degrees) is low. This method is advantageous because the measurement is precise and because the sine can be used without approximation.
Resumo:
Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Objective: To propose an electronic method for sensitivity evaluation in leprosy and to compare it to the Semmes-Weinstein monofilaments. Methods:Thirty patients attending the Dermatology outpatient clinic of HCFMRP-USP were consecutively evaluated by both the electronic aesthesiometer and Semmes-Weinstein monofilaments on hand and foot test points. The intraclass correlation coefficient (ICC) was calculated to determine the variability of the electronic measures and the Kappa coefficient was calculated to determine the agreement between methods according to their categories (altered and non-altered tactile sensitivity). Results: The ICC was approximately 1, demonstrating repeatability. The Kappa coefficient showed more than 75 and 63% agreement on the hand and foot points, respectively. The mean agreement between the 2 methods for the 7 points of the right and left hand was 77.14 and 75.71%, respectively. The mean agreement for all 10 points was 74.33 and 63.66% on the right and left foot, respectively. In cases of disagreement the detection of altered tactile sensitivity by the electronic esthesiometer on the right and left foot was 90.91 and 84.25%, respectively, with no detection by the monofilaments. Conclusion: The results suggest that the electronic esthesiometer is a reliable and easy application, capable of evaluating alterations of tactile sensitivity in leprosy patients. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The objective of this study was to test a device developed to improve the functionality, accuracy and precision of the original technique for sweating rate measurements proposed by Schleger and Turner [Schleger AV, Turner HG (1965) Aust J Agric Res 16:92-106]. A device was built for this purpose and tested against the original Schleger and Turner technique. Testing was performed by measuring sweating rates in an experiment involving six Mertolenga heifers subjected to four different thermal levels in a climatic chamber. The device exhibited no functional problems and the results obtained with its use were more consistent than with the Schleger and Turner technique. There was no difference in the reproducibility of the two techniques (same accuracy), but measurements performed with the new device had lower repeatability, corresponding to lower variability and, consequently, to higher precision. When utilizing this device, there is no need for physical contact between the operator and the animal to maintain the filter paper discs in position. This has important advantages: the animals stay quieter, and several animals can be evaluated simultaneously. This is a major advantage because it allows more measurements to be taken in a given period of time, increasing the precision of the observations and diminishing the error associated with temporal hiatus (e.g., the solar angle during field studies). The new device has higher functional versatility when taking measurements in large-scale studies (many animals) under field conditions. The results obtained in this study suggest that the technique using the device presented here could represent an advantageous alternative to the original technique described by Schleger and Turner.
Resumo:
A method for the determination of volatile organic compounds (VOCs) in recycled polyethylene terephthalate and high-density polyethylene using headspace sampling by solid-phase microextraction and gas chromatography coupled to mass spectrometry detection is presented. This method was used to evaluate the efficiency of cleaning processes for VOC removal from recycled PET. In addition, the method was also employed to evaluate the level of VOC contamination in multilayer packaging material containing recycled HDPE material. The optimisation of the extraction procedure for volatile compounds was performed and the best extraction conditions were found using a 75 mu m carboxen-polydimethylsiloxane (CAR-PDMS) fibre for 20 min at 60 degrees C. The validation parameters for the established method were linear range, linearity, sensitivity, precision (repeatability), accuracy (recovery) and detection and quantification limits. The results indicated that the method could easily be used in quality control for the production of recycled PET and HDPE. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In the present study, cadmium and lead in the muscle, lung, liver and kidney of dolphins (Sotalia guianensis and Stenella clymene) of the Bahia coast in the northwest of Brazil were determined by graphite furnace atomic absorption spectrometry. Samples were digested using a diluted oxidant mixture (HNO(3) + H(2)O(2)) with a microwave heating program performed in five steps. The optimized temperatures and chemical modifier for the pyrolysis and atomization were 700 degrees C, 1400 degrees C and Pd plus Mg for Cd, and 900 degrees C, 1800 degrees C and NH(4)H(2)PO(4) for Pb, respectively. Characteristic masses and limits of detections (n = 20, 3 sigma) for Cd and Pb were 1.6 and 9.0 pg and 0.82 ng g(-1) and 0.50 ng g(-1), respectively. Repeatability ranged from 0.87 to 8.22% for Cd and 4.31 to 8.09% for Pb. The found concentrations presented no statistical differences at the 95% confidence level when compared with the ICP OES methods. Addition and recovery tests were also performed and the results ranged between 87 and 112% for both elements. Samples of cetacean Dolphinidae (S. guianensis and S. clymene) were analyzed, and the higher concentrations ranged from 0.09 to 46.2 mu g g(-1) for Cd and 0.04 to 0.47 mu g g(-1) for Pb in liver, and from 0.133 to 277 mu g g(-1) for Cd in the kidney. (C) 2010 Elsevier By. All rights reserved.
Resumo:
A novel approach was developed for nitrate analysis in a FIA configuration with amperometric detection (E=-0.48 V). Sensitive and reproducible current measurements were achieved by using a copper electrode activated with a controlled potential protocol. The response of the FIA amperometric method was linear over the range from 0.1 to 2.5 mmol L(-1) nitrate with a detection limit of 4.2 mu mol L(-1) (S/N = 3). The repeatability of measurements was determined as 4.7% (n=9) at the best conditions (flow rate: 3.0 mL min(-1), sample volume: 150 mu L and nitrate concentration: 0.5 mmol L(-1)) with a sampling rate of 60 samples h(-1). The method was employed for the determination of nitrate in mineral water and soft drink samples and the results were in agreement with those obtained by using a recommended procedure. Studies towards a selective monitoring of nitrite were also performed in samples containing nitrate by carrying out measurements at a less negative potential (-0.20 V). (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Hydrogen peroxide was determined in oral antiseptic and bleach samples using a flow-injection system with amperometric detection. A glassy carbon electrode modified by electrochemical deposition of ruthenium oxide hexacyanoferrate was used as working electrode and a homemade Ag/AgCl (saturated KCl) electrode and a platinum wire were used as reference and counter electrodes, respectively. The electrocatalytic reduction process allowed the determination of hydrogen peroxide at 0.0 V. A linear relationship between the cathodic peak current and concentration of hydrogen peroxide was obtained in the range 10-5000 mu mol L(-1) with detection and quantification limits of 1.7 (S/N = 3) and 5.9 (S/N = 10) mu mol L(-1), respectively. The repeatability of the method was evaluated using a 500 mu mol L(-1) hydrogen peroxide solution, the value obtained being 1.6% (n = 14). A sampling rate of 112 samples h(-1) was achieved at optimised conditions. The method was employed for the quantification of hydrogen peroxide in two commercial samples and the results were in agreement with those obtained by using a recommended procedure.
Resumo:
Flow injection analysis (FIA) using a carbon film sensor for amperometric detection was explored for ambroxol analysis in pharmaceutical formulations. The specially designed flow cell designed in the lab generated sharp and reproducible current peaks, with a wide linear dynamic range from 5 x 10(-7) to 3.5 x 10(-4) mol L-1, in 0.1 mol L-1 sulfuric acid electrolyte, as well as high sensitivity, 0.110 A mol(-1) L cm(-2) at the optimized flow rate. A detection limit of 7.6 x 10(-8) mol L-1 and a sampling frequency of 50 determinations per hour were achieved, employing injected volumes of 100 mu L and a flow rate of 2.0 mL min(-1). The repeatability, expressed as R.S.D. for successive and alternated injections of 6.0 x 10(-6) and 6.0 x 10(-5) mol L-1 ambroxol solutions, was 3.0 and 1.5%, respectively, without any noticeable memory effect between injections. The proposed method was applied to the analysis of ambroxol in pharmaceutical samples and the results obtained were compared with UV spectrophotometric and acid-base titrimetric methods. Good agreement between the results utilizing the three methods and the labeled values was achieved, corroborating the good performance of the proposed electrochemical methodology for ambroxol analysis. (C) 2008 Elsevier B.V. All rights reserved.