In this study, 20 Brazilian public schools have been assessed regarding good manufacturing practices and standard sanitation operating procedures implementation. We used a checklist comprised of 10 parts ( facilities and installations, water supply, equipments and tools, pest control, waste management, personal hygiene, sanitation, storage, documentation, and training), making a total of 69 questions. The implementing modification cost to the found nonconformities was also determined so that it could work with technical data as a based decision-making prioritization. The average nonconformity percentage at schools concerning to prerequisite program was 36%, from which 66% of them own inadequate installations, 65% waste management, 44% regarding documentation, and 35% water supply and sanitation. The initial estimated cost for changing has been U.S.$24,438 and monthly investments of 1.55% on the currently needed invested values. This would result in U.S.$0.015 increase on each served meal cost over the investment replacement within a year. Thus, we have concluded that such modifications are economically feasible and will be considered on technical requirements when prerequisite program implementation priorities are established.
Resumo:
As a consequence of the large distribution and use of medicinal plants, the industries are producing products based on plant species in various pharmaceutical forms, which have been commercialized in pharmacies and natural products homes. However, there is no guarantee for the vast majority of these products, as to their effctiveness, safety, and quality, which may cause risks to the health of consumers. There it is important the establishment of standardized protocols of quality control for phytotherapeutic products. Tinctures of barbatimao are available in the Brazilian market proceeding from diverse manufacturers. With the purpose to evaluate the difference between the quality of tinctures of barbatimao proceeding from four manufactures, a comparative study of ph ysico-chenfical andphylocheinical characteristics was carried out. For physico-chemical analysis, the pH, density, dry residue and tannins content were evaluated. The phytochemical analysis was made using thin layer chromatography. The differences observed in physico-chemical and phytochemical characteristics had evidenced the lack of standardization in the production of these tinctures.
Resumo:
The present study evaluates a possible protective effect of fish oil against oxidative damage promoted by methylmercury (MeHg) in sub-chronically exposed rats. Reduced glutathione peroxidase and catalase enzyme activity and reduced glutathione levels were observed in MeHg-exposed animals compared to controls. Methylmercury exposure was also associated with DNA damage. Administration of fish oil to the methylmercury-exposed animals did not ameliorate enzyme activity or glutathione levels. On the other hand, a significant DNA protective effect (about 30%) was observed with fish oil treatment. There were no differences in the total mercury concentration in rat liver, kidney, heart or brain after MeHg administration with or without fish oil co-administration. Histopathological analyses showed a significant leukocyte infiltration in rat tissues after MeHg exposure, but this effect was significantly reduced after co-administration of fish oil. Taken together, our findings demonstrate oxidative damage even after low-level MeHg exposure and the protective effect of fish oil. This protection seems not to be related to antioxidant defenses or mercury re-distribution in rat tissues. It is probably due to the anti-inflammatory effects of fish oil. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
In a dynamic atmosphere of competitiveness, customer satisfaction is a key factor in the long term success of a business relationship. From this perspective, the objective of the article was to evaluate the importance of attributes and customer satisfaction with Supermarkets in the Mid-Valley region of the ltajai/SC. Research methodology is characterized as descriptive, of the survey type, with a quantitative, cross section approach. The research instrument used was a questionnaire structured with open and closed questions, according to Lickert`s scale. By means of this, the degree of importance of supermarket attributes and the level of customer satisfaction with them were verified. In regard to the importance of the attributes, cleaning, parking, safety and variety of products are the most important, while the attributes Of purchase through the internet and taste samples are the least significant ones. The results of satisfaction point to the fact that the Supermarkets Big and Angeloni presented a greater degree of satisfaction in relation to the general average in practically all of the attributes, while Bistek presented the smallest degree of satisfaction, only surpassing the average in regard to the attribute of store lighting.
Resumo:
Background: Obesity is a serious chronic disease and the prevalence of this condition is increasing among the elderly. Although the benefits of weight loss to improve control of associated diseases are well known in young adults, they are not in older patients. The use of anti-obesity drugs to promote weight loss is widespread in Brazil and other countries, and obesity specialists frequently prescribe medicines in doses and for durations previously unreported in the literature. Sibutramine, orlistat and amfepramone (diethylpropion) have been evaluated in clinical trials of more than 2 years` duration in adults, demonstrating safety and efficacy, but long-term studies in obesity treatment are absent for other drugs. The efficacy and safety of obesity pharmacotherapy among the elderly is unknown. Objective: To describe the experience of obesity pharmacotherapy in the elderly in a specialized obesity care setting in Brazil, with a focus on efficacy and safety. Methods: A retrospective evaluation was conducted on medical charts from an outpatient clinic of a specialized tertiary centre for the treatment of obesity. We included patients who had had at least one consultation between January and December 2007, were aged >= 60 years at the beginning of the treatment, had had at least 6 months of follow-up and had received a prescription of at least one potential weight-loss drug. Diagnoses reported on medical records were documented. Age, weight, height and body mass index (BMI) were recorded at admission, after 6, 12, 18 and 24 months, and at the last available visit. The medicines prescribed, together with the dose, duration of use, adverse effects and reasons for discontinuation, were documented. Results: The group consisted of 44 women (86%) and 7 men (14%), with a mean +/- SD age of 65.2 +/- 4.5 years, weight of 95.3 +/- 12.5 kg and BMI of 38.5 +/- 4.3 kg/m(2). The mean +/- SD time of follow-up was 39.3 +/- 26.4 months, and the mean weight loss was 6.65 kg (p < 0.01). After the first 6 months, the mean +/- SD weight loss was 5.7 +/- 3.8 kg (p < 0.0001). A smaller weight loss was seen between the 6th and 12th months, with no statistically significant change in weight thereafter. A weight loss of >= 5% was achieved by 64.71%, 63.64%, 62.16% and 69.70% in the 6th, 12th, 18th and 24th months, respectively, and a weight loss of >= 10% was achieved by 17.65%, 34.09%, 32.43% and 39.39% in the 6th, 12th, 18th and 24th months, respectively. The medicines prescribed were sibutramine, orlistat, fluoxetine, sertraline, topiramate, fenproporex, mazindol and amfepramone, alone or in combinations, concomitantly or sequentially. The reasons for discontinuation were lack of response (n = 13), loss of response (development of tolerance) [n= 11], lack of adherence (n = 14) and adverse effects (n= 14). One episode of atrial flutter occurred in a patient taking fenproporex. The weight-loss medications were generally well tolerated, and only transient adverse events were reported. Conclusions: Long-term pharmacotherapy for obesity was effective and well tolerated by this group of elderly patients.
Resumo:
Objectives: We tested two novel drug-eluting stents (DES), covered with a biodegradable-polymer carrier and releasing paclitaxel or sirolimus, which were compared against a bare metal stent (primary objective). The DES differed by the drug, but were identical otherwise, allowing to compare the anti-restenosis effects of sirolimus versus paclitaxel (secondary objective). Background: The efficacy of novel DES with biodegradable polymers should be tested in the context of randomized trials, even when using drugs known to be effective, such as sirolimus and paclitaxel. Methods: Overall, 274 patients with de novo coronary lesions in native vessels scheduled for stent implantation were randomly assigned (2:21 ratio) for the paclitaxel (n = 111), sirolimus (n = 106), or bare metal stent (n = 57) groups. Angiographic follow-up was obtained at 9 months and major cardiac adverse events up to 12 months. Results: Both paclitaxel and sirolimus stents reduced the 9-month in-stent late loss (0.54-0.44 mm, 0.32-0.43 mm, vs. 0.90-0.45 mm respectively), and 1-year risk of target vessel revascularization and combined major adverse cardiac events (P < 0.05 for both, in all comparisons), compared with controls. Sirolimus stents had lower late loss than paclitaxel stents (P < 0.01), but similar 1-year clinical outcomes. There were no differences in the risk of death, infarction, or stent thrombosis among the study groups. Conclusion: Both novel DES were effective in reducing neointimal hyperplasia and 1-year re-intervention, compared to bare metal stents. Our findings also suggest that sirolimus is more effective than paclitaxel in reducing angiographic neointima, although this effect was not associated with better clinical outcomes. (C) 2009 Wiley-Liss, Inc.
Resumo:
Objective: To evaluate the efficacy of diethylpropion on a long-term basis, with emphasis in cardiovascular and psychiatric safety aspects. Design: Randomized, double-blind, placebo-controlled trial Measurements: Following a 2-week screening period, 69 obese healthy adults received a hypocaloric diet and were randomized to diethylpropion 50 mg BID (n = 37) or placebo (n = 32) for 6 months. After this period, all participants received diethylpropion in an open-label extension for an additional 6 months. The primary outcome was percentage change in body weight. Electrocardiogram (ECG), echocardiography and clinical chemistry were performed at baseline and every 6 months. Psychiatric evaluation and application of Hamilton rating scales for depression and anxiety were also performed by experienced psychiatrists at baseline and every 3 months. Results: After 6 months, the diethylpropion group lost an average of 9.8% (s.d. 6.9%) of initial body weight vs 3.2% (3.7%) in the placebo group (P < 0.0001). From baseline to month 12, the mean weight loss produced by diethylpropion was 10.6% (8.3%). Participants in the placebo group who were switched to diethylpropion after 6 months lost an average of 7.0% (7.7%) of initial body weight. The difference between groups at month 12 was not significant (P = 0.07). No differences in blood pressure, pulse rate, ECG and psychiatric evaluation were observed. Dry mouth and insomnia were the most frequent adverse events. Conclusion: Diethylpropion plus diet produced sustained and clinically significant weight loss over 1 year. It seems to be safe in relation to cardiovascular and psychiatric aspects in a well-selected population. International Journal of Obesity (2009) 33, 857-865; doi: 10.1038/ijo.2009.124; published online 30 June 2009
Resumo:
BACKGROUND: Tacrolimus ointment has been shown to be effective in treatment of atopic dermatitis. OBJECTIVES: To evaluate the efficacy and safety of 0.03% tacrolimus ointment (Protopic(R)) in pediatric patients with mild, moderate and severe atopic dermatitis. METHODS.. Open, non-comparative, multicentric study carried out in Brazil. 174 patients (ages from two to 10) with mild to severe atopic dermatitis were included. Patients were instructed to apply Protopic(R) twice a day for six weeks. Primary efficacy criterion was clinical improvement >= 90% assessed by the pbysician (Clinical Response Global Evaluation Scale). Other efficacy criteria included reduction of the Eczema Area Severity Index (EASI), decrease of the affected body surface area (%BSA) and evaluation of the itching by the patients or their guardians (visual analogical scale). Safety was evaluated by adverse events reported by patients and/or guardians or by investigators. RESULTS: Thirty-three percent of patients showed clinical improvement 90%. 45.5% of patients (1st week) decreased EASI and 61.8% (6th week) (p<0,001). %BSA decreased 30.4% and 55.5% in the first and sixth week. improvement was also significant when measured by itching (p<0, 001). Most frequent adverse effects were: burning and itching. CONCLUSION: 0.03% tacrolimus ointment is a safe and effective therapy for mild to severe atopic dermatitis in pediatric patients.
Resumo:
Aims: There remains significant concern about the long-term safety of drug-eluting stents (DES). However, bare metal stents (BMS) have been used safely for over two decades. There is therefore a pressing need to explore alternative strategies for reducing restenosis with BMS. This study was designed to examine whether IVUS-guided cutting balloon angioplasty (CBA) with BMS could convey similar restenosis rates to DES. Methods and results: In the randomised REstenosis reDUction by Cutting balloon angioplasty Evaluation (REDUCE III) study, 521 patients were divided into four groups based on device and IVUS use before BMS (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up, the IVUS-CBA-BMS group had a significantly lower restenosis rate (6.6%) than the other groups (p=0.016). We performed a quantitative coronary angiography (QCA) based matched comparison between an IVUS-guided CBA-BMS strategy (REDUCE III) and a DES strategy (Rapamycin-Eluting-Stent Evaluation At Rotterdam Cardiology. Hospital, the RESEARCH study). We matched the presence of diabetes, vessel size, and lesion severity by QCA. Restenosis (>50% diameter stenosis at follow-up) and target vessel revascularisation (TVR) were examined. QCA-matched comparison resulted in 120-paired lesions. While acute gain was significantly greater in IVUS-CBA-BMS than DES (1.65 +/- 0.41 mm vs. 1.28 +/- 0.57 mm, p=0.001), late loss was significantly less with DES than with IVUS-CBA-BMS (0.03 +/- 0.42 mm vs. 0.80 +/- 0.47 mm, p=0.001). However, no difference was found in restenosis rates (IVUS-CBA-BMS: 6.6% vs. DES: 5.0%, p=0.582) and TVR (6.6% and 6.6%, respectively). Conclusions: An IVUS-guided CBA-BMS strategy yielded restenosis rates similar to those achieved by DES and provided an effective alternative to the use of DES.
Resumo:
Background: Despite all benefits offered by mandible distraction, complications and long-term consequences need to be evaluated to define its safety and morbidity. Forty mandible distractions were studied. Panoramic mandible radiographs obtained preoperatively, during distraction, and during the postoperative period were reviewed, with the intention of evaluating development and complications of molar buds and teeth in the distraction area. Methods: The mean patient age was 8.1 years. Twenty-five patients had craniofacial microsomia (one associated with a no. 10 facial cleft), five had temporomandibular joint ankylosis, two had familiar cases of auriculocondylar syndrome, one had a Tessier no. 30 facial cleft, and one had Treacher Collins syndrome. The severity of mandible hypoplasia was Pruzansky grade I in four cases, grade IIA in eight cases, grade 1113 in 16 cases, and grade III in one case. Mean radiographic follow-up was 44.8 months. Results: Molar buds located in the distraction area erupted without any deformity or displacement in 18 sides (45 percent). Fourteen cases presented distalization of a dental bud to a superior position in the mandibular ramus (four migrated back to the original position). Six molar buds presented perforations, four had shape deformities (two caused by dental fracture), and two had dental root injuries followed by root absorption lately. One case developed a dentigerous cyst. Conclusions: Almost half of the patients did not have any molar bud or tooth alterations after mandible distraction, and more than 20 percent presented only bud distalization. Therefore, preventive bud enucleation or tooth extraction should be avoided before mandible distraction.
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Sampling protocols for detecting Salmonella on poultry differ among various countries. In the United States, the U.S. Department of Agriculture Food Safety and Inspection Service dictates that whole broiler carcasses should be rinsed with 400 ml of 1% buffered peptone water, whereas in the European Union 25-g samples composed of neck skin from three carcasses are evaluated. The purpose of this study was to evaluate a whole carcass rinse (WCR) and a neck skin excision (NS) procedure for Salmonella and Escherichia coli isolation from the same broiler carcass. Carcasses were obtained from three broiler processing plants. The skin around the neck area was aseptically removed and bagged separately from the carcass, and microbiological analysis was performed. The corresponding carcass was bagged and a WCR sample was evaluated. No significant difference (alpha <= 0.05) in Salmonella prevalence was found between the samples processed by the two methods, but both procedures produced many false-negative Salmonella results. Prechill, 37% (66 carcasses), 28% (50 carcasses), and 51% (91 carcasses) of the 180 carcasses examined were positive for Salmonella by WCR, NS, and both procedures combined, respectively. Postchill, 3% (5 carcasses), 7% (12 carcasses), and 10% (17 carcasses) of the 177 carcasses examined were positive for Salmonella by the WCR, NS, and combination of both procedures, respectively. Prechill, E. coli plus coliform counts were 3.0 and 2.6 log CFU/ml by the WCR and NS methods, respectively. Postchill. E. coli plus coliform counts were 1.7 and 1.4 log CFU/ml by the WCR and NS methods, respectively.