45 resultados para Healthcare improvement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, SiC ceramics were liquid phase sintered (LPS), using AIN-Y(2)O(3) as additives, and oxidized at 1400 degrees C in air for up to 120 h. Oxidation was monitored by the weight gain of the samples as function of exposition time and temperature. A parabolic growth of the oxidation layer has been observed and the coefficient of the growth rate has been determined by relating the weight gain and the surface area. The effect of oxidation on strength has been determined by 4-point bending tests. Phase analysis by Xray diffraction and microstructural observation by scanning electron microscopy indicated the formation of a uniform and dense oxidation layer. The elimination of surface flaws and pores and the generation of compressive stresses in the surface resulted in a strength increase of the oxidized samples. (C) 2009 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The health sector requires continuous investments to ensure the improvement of products and services from a technological standpoint, the use of new materials, equipment and tools, and the application of process management methods. Methods associated with the process management approach, such as the development of reference models of business processes, can provide significant innovations in the health sector and respond to the current market trend for modern management in this sector (Gunderman et al. (2008) [4]). This article proposes a process model for diagnostic medical X-ray imaging, from which it derives a primary reference model and describes how this information leads to gains in quality and improvements. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A duplex surface treatment consisting of High Temperature Gas Nitriding (HTGN) followed by Low Temperature Plasma Nitriding (LTPN) was carried out in an UNS S31803 duplex stainless steel. The HTGN treatment was intended to produce a relatively thick and hard fully austenitic layer giving mechanical support to the thinner and much harder expanded austenite layer. HTGN was performed at 1200 degrees C for 3 h, in a 0.1 MPa N(2) atmosphere while LTPN, was carried out in a 75% N(2) + 25% H(2) atmosphere, at 400 degrees C for 12 h, under a 250 Pa pressure, and 450 V. An expanded austenite gamma(N) layer, 2.3 mu m thick, 1500 HVO.025 hard, was formed on top of a 100 mu m thick, 330 HV 0.1 hard, fully austenitic layer, containing 0.9 wt% N. For comparison purposes LTPN was carried out with UNS S30403 stainless steel specimens obtaining a 4.0 mu m thick, 1500 HV 0.025 hard, expanded austenite layer formed on top of a fully austenitic matrix having 190 HV 0.1. The nitrided specimens were tested in a 20 kHz vibratory cavitation-erosion testing equipment. Comparison between the duplex treated UNS S31803 steel and the low temperature plasma nitrided UNS S30403 steel, resulted in incubation times almost 9 times greater. The maximum cavitation wear rate of the LTPN UNS S30403 was 5.5 g/m(2)h, 180 times greater than the one measured for the duplex treated UNS S31803 steel. The greater cavitation wear resistance of the duplex treated UNS S31803 steel, compared to the LTPN treated UNS S30403 steel was explained by the greater mechanical support the fully austenitic, 330 HV 0.1 hard, 100 mu m layer gives to the expanded austenite layer formed on top of the specimen after LTPN. A strong crystallographic textured surface, inherited from the fully austenitic layer formed during HTGN, with the expanded austenite layer showing {101} crystallographic planes//surface contributed also to improve the cavitation resistance of the duplex treated steel. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the effect of cerium (IV) ammonium nitrate (CAN) addition on the polymerization of bis-[triethoxysilyl]ethane (BTSE) film applied on carbon steel was studied. The electrochemical characterization of the films was carried out in 0.1 mol L(-1) NaCl solution by open-circuit potential measurements, anodic and cathodic polarization curves and electrochemical impedance spectroscopy (EIS). Morphological and chemical characterization were performed by atomic force microscopy (AFM), contact angle measurements, infrared-spectroscopy, nuclear magnetic resonance and thermogravimetric analysis. The results have clearly shown the improvement on the protective properties of the Ce(4+) modified film as a consequence of the formation of a more uniform and densely reticulated silane film. A mechanism is proposed to explain the accelerating role of Ce(4+) ions on the cross-linking of the silane layer. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light touch of a fingertip on an external stable surface greatly improves the postural stability of standing subjects. The hypothesis of the present work was that a vibrating surface could increase the effectiveness of fingertip signaling to the central nervous system (e.g., by a stochastic resonance mechanism) and hence improve postural stability beyond that achieved by light touch. Subjects stood quietly over a force plate while touching with their right index fingertip a surface that could be either quiescent or randomly vibrated at two low-level noise intensities. The vibratory noise of the contact surface caused a significant decrease in postural sway, as assessed by center of pressure measures in both time and frequency domains. Complementary experiments were designed to test whether postural control improvements were associated with a stochastic resonance mechanism or whether attentional mechanisms could be contributing. A full curve relating body sway parameters and different levels of vibratory noise resulted in a U-like function, suggesting that the improvement in sway relied on a stochastic resonance mechanism. Additionally, no decrease in postural sway was observed when the vibrating contact surface was attached to the subject`s body, suggesting that no attentional mechanisms were involved. These results indicate that sensory cues obtained from the fingertip need not necessarily be associated with static contact surfaces to cause improvement in postural stability. A low-level noisy vibration applied to the contact surface could lead to a better performance of the postural control system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rare HFE variants have been shown to be associated with hereditary hemochromatosis (HH), an iron overload disease. The low frequency of the HFE p.C282Y mutation in HH-affected Brazilian patients may suggest that other HFE-related mutations may also be implicated in the pathogenesis of HH in this population. The main aim was to screen for new HFE mutations in Brazilian individuals with primary iron overload and to investigate their relationship with HH. Fifty Brazilian patients with primary iron overload (transferrin saturation >50% in females and 60% in males) were selected. Subsequent bidirectional sequencing for each HFE exon was performed. The effect of HFE mutations on protein structure were analyzed by molecular dynamics simulation and free binding energy calculations. p.C282Y in homozygosis or in heterozygosis with p.H63D were the most frequent genotypic combinations associated with HH in our sample population (present in 17 individuals, 34%). Thirty-six (72.0%) out of the 50 individuals presented at least one HFE mutation. The most frequent genotype associated with HH was the homozygous p.C282Y mutation (n = 11, 22.0%). One novel mutation (p.V256I) was indentified in heterozygosis with the p.H63D mutation. In silico modeling analysis of protein behavior indicated that the p.V256I mutation does not reduce the binding affinity between HFE and beta 2-microglobulin ((beta 2M) in the same way the p.C282Y mutation does compared with the native HFE protein. In conclusion, screening of HFE through direct sequencing, as compared to p.C282Y/p.H63D genotyping, was not able to increase the molecular diagnosis yield of HH. The novel p.V256I mutation could not be implicated in the molecular basis of the HH phenotype, although its role cannot be completely excluded in HH-phenotype development. Our molecular modeling analysis can help in the analysis of novel, previously undescribed, HFE mutations. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prominent nitric oxide (NO) donor [Ru(terpy)(bdqi)NO](PF(6))(3) has been synthesized and evaluated with respect to noteworthy biological effects due to its NO photorelease, including vascular relaxation and melanoma cell culture toxicity. The potential for delivering NO in therapeutic quantities is tenable since the nitrosyl ruthenium complex (NRC) must first reach the ""target tissue"" and then release the NO upon stimulus. In this context. NRC-loaded lipid carriers were developed and characterized to further explore its topical administration for applications such as skin cancer treatment. NRC-loaded solid lipid nanoparticles (SLN) and nanostructured lipid carriers were prepared via the microemulsification method, with average diameters of 275 +/- 15 nm and 211 +/- 31 nm and zeta potentials of -40.7 +/- 10.4 mV and -50.0 +/- 7.5 mV, respectively. In vitro kinetic studies of NRC release from nanoparticles showed sustained release of NRC from the lipid carriers and illustrated the influence of the release medium and the lyophilization process. Stability studies showed that NO is released from NRC as a function of temperature and time and due to skin contact. The encapsulation of NRC in SLN followed by its lyophilization, significantly improved the complex stability. Furthermore, of particular interest was the fact that in the NO photorelease study, the NO release from the NRC-loaded SLN was approximately twice that of just NRC in solution. NRC-loaded SLN performs well enough at releasing and protecting NO degradation in vitro that it is a promising carrier for topical delivery of NO. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bariatric surgery in morbidly obese type 2 diabetic (T2DM) patients is associated with high rates of diabetes remission. We investigated the mechanisms of the anti-diabetic effect of the laparoscopic ileal interposition with sleeve gastrectomy (LII-SG) in normal weight (NW), overweight (OW) and obese (OB) T2DM patients. Ninety-four patients (aged 54 +/- 8 years) with long-standing (median 10 years), treated diabetes (median HbA(1c) = 8.6%), who were NW (15), OW (64) or OB (15) based on BMI, underwent LII-SG. Insulin sensitivity and parameters of -cell function were measured from an Oral Glycaemic Tolerance Test pre- and post-operatively. At a median of 13.4 months post-operatively, weight loss averaged 9.4 +/- 1.3, 16.8 +/- 0.8 and 23.2 +/- 1.7 kg in NW, OW and OB subjects, respectively (p < 0.0001). Insulin sensitivity was fully restored (395 [108] vs 208 [99] ml min(-1) m(-2)), fasting insulin secretion rate decreased (68 [52] vs 146 [120] pmol min(-1) m(-2)) and total insulin output increased (52 [26] vs 39 [28] nmol m(-2), all p a parts per thousand currency signaEuro parts per thousand 0.001). -cell glucose sensitivity doubled (37 [33] vs 18 [24] mol min(-1) m(-2) mM(-1), p < 0.0001). The only parameter predicting remission of diabetes was a lower baseline insulin sensitivity (p = 0.005). LII-SG induced changes on T2DM by mechanisms in part distinct from weight loss, principally involving restoration of insulin sensitivity and improvement of -cell function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite modern reanimation surgical techniques, facial paralysis presents with functional and aesthetic deficits. We evaluated facial symmetry after treating with botulinum toxin the healthy side of the face of 25 patients with long-standing facial paralysis who had previously been treated by surgical methods, with 6 months follow-up. Evaluation consisted of a clinical score, the two subscales of the Facial Disability Index, and surface electromyography. The mean botulinum toxin dose was 38 +/- A 5 U (range = 15-69 U). The clinical score showed significant reduction of asymmetry of 48.4% at 1 month and 16.8% after 6 months. The initial result was a consequence of reduced motion on the treated side combined with better motion on the paralyzed side. At 6 months, the treated side returned to basal scores. The residual effect seen in symmetry was due to an increase (18%) of motion in the paralyzed side. There was a significant decrease in the action potential of muscles on the nonparalyzed side 1 month post injection but completely reverted after 6 months. The Physical Function Index increased, but not significantly. The Social/Well-Being Function Index showed a significant increase at 6 months compared to pretreatment. The proposed treatment improved facial symmetry for up to 6 months. Even after the end of the clinical effect of the drug, the paralyzed side`s clinical score was 18% higher than pretreatment, with an increased quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Physical and psychological incapacity, including fear of falling is related to decreased satisfaction with life in osteoporosis (OP). The impact of a balance exercise program on improving the quality of life is not well established. We have, therefore, investigated the effect of 12-month Balance Training Program in quality of life, functional balance and falls in elderly OP women. Methods: Sixty consecutive women with senile OP were randomized into a Balance Training Group (BT) of 30 patients and no intervention control group (CG) of 30 patients. The BT program included techniques to improve balance over a period of 12 months (1 h exercise session/week and home-based exercises). The quality of life was evaluated before and at the end of the trial using the Osteoporosis Assessment Questionnaire (OPAQ), functional balance was evaluated by Berg Balance Scale (BBS). Falls in the preceding year were noted and compared to the period of study. Results: The comparison of OPAQ variations (INITIAL-FINAL) revealed a significant improvement in quality of life in all parameters for BT compared to CG: well-being (1.61 +/- 1.44 vs. -1.46 +/- 1.32, p < 0001), physical function (1.30 +/- 1.33 vs. -0.36 +/- 0.82, p < 0.001), psychological status (1.58 +/- 1.36 vs. -1.02 +/- 0.83, p < 0.001), symptoms (2.76 +/- 1.96 vs. -0.63 +/- 0.87, p < 0.001), social interaction (1.01 +/- 1.51 vs. 0.35 +/- 1.08, p < 0.001). Of note, this overall benefit was paralleled by an improvement of BBS (-5.5 +/- 5.67 vs. +0.5 +/- 4.88 p < 0.001) and a reduction of falls in 50% in BT group vs. 26.6% for the CG (RR: 1.88, p < 0.025). Conclusion: The long-term Balance Training Program of OP women provides a striking overall health quality of life improvement in parallel with improving functional balance and reduced falls. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-Prasugrel is a novel thienopyridine that reduces new or recurrent myocardial infarctions (MIs) compared with clopidogrel in patients with acute coronary syndrome undergoing percutaneous coronary intervention. This effect must be balanced against an increased bleeding risk. We aimed to characterize the effect of prasugrel with respect to the type, size, and timing of MI using the universal classification of MI. Methods and Results-We studied 13 608 patients with acute coronary syndrome undergoing percutaneous coronary intervention randomized to prasugrel or clopidogrel and treated for 6 to 15 months in the Trial to Assess Improvement in Therapeutic Outcomes by Optimizing Platelet Inhibition With Prasugrel-Thrombolysis in Myocardial Infarction (TRITON-TIMI 38). Each MI underwent supplemental classification as spontaneous, secondary, or sudden cardiac death (types 1, 2, and 3) or procedure related (Types 4 and 5) and examined events occurring early and after 30 days. Prasugrel significantly reduced the overall risk of MI (7.4% versus 9.7%; hazard ratio [HR], 0.76; 95% confidence interval [CI], 0.67 to 0.85; P < 0.0001). This benefit was present for procedure-related MIs (4.9% versus 6.4%; HR, 0.76; 95% CI, 0.66 to 0.88; P = 0.0002) and nonprocedural (type 1, 2, or 3) MIs (2.8% versus 3.7%; HR, 0.72; 95% CI, 0.59 to 0.88; P = 0.0013) and consistently across MI size, including MIs with a biomarker peak >= 5 times the reference limit (HR. 0.74; 95% CI, 0.64 to 0.86; P = 0.0001). In landmark analyses starting at 30 days, patients treated with prasugrel had a lower risk of any MI (2.9% versus 3.7%; HR, 0.77; P = 0.014), including nonprocedural MI (2.3% versus 3.1%; HR, 0.74; 95% CI, 0.60 to 0.92; P = 0.0069). Conclusion-Treatment with prasugrel compared with clopidogrel for up to 15 months in patients with acute coronary syndrome undergoing percutaneous coronary intervention significantly reduces the risk of MIs that are procedure related and spontaneous and those that are small and large, including new MIs occurring during maintenance therapy. (Circulation. 2009; 119: 2758-2764.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. The aim of this study was to understand the heart transplantation experience based on patients` descriptions. Background. To patients with heart failure, heart transplantation represents a possibility to survive and improve their quality of life. Studies have shown that more quality of life is related to patients` increasing awareness and participation in the work of the healthcare team in the post-transplantation period. Deficient relationships between patients and healthcare providers result in lower compliance with the postoperative regimen. Method. A phenomenological approach was used to interview 26 patients who were heart transplant recipients. Patients were interviewed individually and asked this single question: What does the experience of being heart transplanted mean? Participants` descriptions were analysed using phenomenological reduction, analysis and interpretation. Results. Three categories emerged from data analysis: (i) the time lived by the heart recipient; (ii) donors, family and caregivers and (iii) reflections on the experience lived. Living after heart transplant means living in a complex situation: recipients are confronted with lifelong immunosuppressive therapy associated with many side-effects. Some felt healthy whereas others reported persistence of complications as well as the onset of other pathologies. However, all participants celebrated an improvement in quality of life. Health caregivers, their social and family support had been essential for their struggle. Participants realised that life after heart transplantation was a continuing process demanding support and structured follow-up for the rest of their lives. Conclusion. The findings suggest that each individual has unique experiences of the heart transplantation process. To go on living participants had to accept changes and adapt: to the organ change, to complications resulting from rejection of the organ, to lots of pills and food restrictions. Relevance to clinical practice. Stimulating a heart transplant patients spontaneous expression about what they are experiencing and granting them the actual status of the main character in their own story is important to their care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. This study aimed to evaluate manometric parameters that may explain improvement in anal incontinence using a silicone bulking agent. Methods. Incontinent patients having internal sphincter defects were prospectively selected and injected with a silicone bulking agent. Manometry and endoanal ultrasound were performed before and 3 months after injections. Twenty continent healthy volunteers were used only for manometric comparison. Results. Thirty-five patients (28 females; mean age 60.3 years) and 20 controls entered this study. Patients had lower resting and squeeze pressures compared with controls (P<.05). Length of the high-pressure zone increased from 1 to 1.7 cm postinjection (P=.002). Asymmetry index showed a significant change postinjection (P<.001). Conclusion. Despite considerable clinical improvement, no significant increase in manometric pressures was noted posttreatment. There was significant improvement in both high-pressure zone and asymmetry index, and these findings may explain the mechanism of action of the bulking agent injected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to evaluate the effectiveness of the duodenojejunal bypass liner (DJBL) in the improvement of insulin resistance and reduction of cardiovascular risk among morbidly obese patients with type 2 diabetes mellitus, using the triglyceride/high-density lipoprotein (HDL) cholesterol ratio, percentage of weight loss, and glycemic control. We used the TG/HDL ratio with a cutoff value of 3.5 to identify patients with insulin resistance. The value of the initial ratio was compared with the ratio obtained 6 months after implantation to evaluate whether an improvement in insulin resistance occurred. We also evaluated the improvement of glycated hemoglobin levels and the weight loss resulted from the use of the device and correlated that with the improvement of the TG/HDL ratio. All patients implanted with the device presented a statistically significant reduction of the HbA1c levels, with most patients (70.3%) obtaining diabetes control with HbA1c levels lower than 7% at the end of the study. All patients also presented a significant weight reduction, with an average loss of 12.6% of their initial weight. We observed an important improvement in insulin resistance and metabolic syndrome, with a significant reduction of the TG/HDL ratio from 5.75 to 4.36 (p < 0.001) and 42.6% of the patients presenting a TG/HDL ratio lower than 3.5 at the end of the study. The DJBL, when used for a period of 6 months, is effective in the control of diabetes, weight loss, improvement of insulin resistance, and decrease of cardiovascular risk among morbidly obese patients with type 2 diabetes mellitus.