203 resultados para Engineering, Biomedical|Physics, Optics
Resumo:
Infections with Histoplasma are rarely seen in immunocompromized patients. We report the case of a renal transplant recipient who presented with disseminated histoplasmosis 3.5 years after transplant He presented severe lactic acidosis (LA), sepsis complicated by circulatory failure, renal failure, and liver dysfunction. We describe the successful use of continuous venovenous hemodiafiltration (CVVHDF) with regional citrate anticoagulation, treatment that stabilized our patient until infectious focus was identified and treated. The lactate was decreasing, concomitant with hemodynamic improvement, with reduction and suspension of the norepinephrine. The serum lactate level normalized 52 hours after CVVHDF initiated (from 28.9 to 2.2 mmol/L). Continuous renal replacement therapy was safely applied and can be recommended as an efficient method on adjuvant treatment of hyperlactatemia. ASAIO Journal 2009; 55:123-125.
Resumo:
Age-related changes in running kinematics have been reported in the literature using classical inferential statistics. However, this approach has been hampered by the increased number of biomechanical gait variables reported and subsequently the lack of differences presented in these studies. Data mining techniques have been applied in recent biomedical studies to solve this problem using a more general approach. In the present work, we re-analyzed lower extremity running kinematic data of 17 young and 17 elderly male runners using the Support Vector Machine (SVM) classification approach. In total, 31 kinematic variables were extracted to train the classification algorithm and test the generalized performance. The results revealed different accuracy rates across three different kernel methods adopted in the classifier, with the linear kernel performing the best. A subsequent forward feature selection algorithm demonstrated that with only six features, the linear kernel SVM achieved 100% classification performance rate, showing that these features provided powerful combined information to distinguish age groups. The results of the present work demonstrate potential in applying this approach to improve knowledge about the age-related differences in running gait biomechanics and encourages the use of the SVM in other clinical contexts. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
In this study, we evaluated alternative technical markers for the motion analysis of the pelvic segment. Thirteen subjects walked eight times while tri-dimensional kinematics were recorded for one stride of each trial. Five marker sets were evaluated, and we compared the tilt, obliquity, and rotation angles of the pelvis segment: (1) standard: markers at the anterior and posterior superior iliac spines (ASIS and PSIS); (2) markers at the PSIS and at the hip joint centers, HJCs (estimated by a functional method and described with clusters of markers at the thighs); (3) markers at the PSIS and HJCs (estimated by a predictive method and described with clusters of markers at the thighs); (4) markers at the PSIS and HJCs (estimated by a predictive method and described with skin-mounted markers at the thighs based on the Helen-Hayes marker set); (5) markers at the PSIS and at the iliac spines. Concerning the pelvic angles, evaluation of the alternative technical marker sets evinced that all marker sets demonstrated similar precision across trials (about 1 degrees) but different accuracies (ranging from 1 degrees to 3 degrees) in comparison to the standard marker set. We suggest that all the investigated marker sets are reliable alternatives to the standard pelvic marker set. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
This study reports for the first time an estimation of the internal net joint forces and torques on adults` lower limbs and pelvis when walking in shallow water, taking into account the drag forces generated by the movement of their bodies in the water and the equivalent data when they walk on land. A force plate and a video camera were used to perform a two-dimensional gait analysis at the sagittal plane of 10 healthy young adults walking at comfortable speeds on land and in water at a chest-high level. We estimated the drag force on each body segment and the joint forces and torques at the ankle, knee, and hip of the right side of their bodies using inverse dynamics. The observed subjects` apparent weight in water was about 35% of their weight on land and they were about 2.7 times slower when walking in water. When the subjects walked in water compared with walking on land, there were no differences in the angular displacements but there was a significant reduction in the joint torques which was related to the water`s depth. The greatest reduction was observed for the ankle and then the knee and no reduction was observed for the hip. All joint powers were significantly reduced in water. The compressive and shear joint forces were on average about three times lower during walking in water than on land. These quantitative results substantiate the use of water as a safe environment for practicing low-impact exercises, particularly walking. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Background Falls are one of the greatest concerns among the elderly A number of studies have described peak torque as one of the best fall-related predictor. No studies have comprehensively focused on the rate of torque development of the lower limb muscles among elderly fallers. Then, the aim of this study was to determine the relationship between muscle peak torque and rate of torque development of the lower limb joints in elderly with and without fall history It was also aimed to determine whether these parameters of muscle performance (i e, peak torque and rate of torque development) are related to the number of falls. Methods: Thirty-one women volunteered to participate in the study and were assigned in one of the groups according to the number of falls over the 12 months that preceded the present Then, participants with no fall history (Cl; n = 13; 67.6[7.5] years-old), one fall (GII; n = 8, 66 0[4 91 years-old) and two or more falls (GIII, n = 10; 67.8[8.8] years-old) performed a number of lower limb maximal isometric voluntary contractions from which peak torque and rate of torque development were quantified Findings. Primary outcomes indicated no peak torque differences between experimental groups in any lower limb joint. The rate of torque development of the knee flexor muscles observed in the non-fallers (Cl) was greater than that observed in the fallers (P < 0.05) and had a significant relationship with the number of falls (P < 0 05) Interpretation. The greater knee flexor muscles` rate of torque development found in the non-fallers in comparison to the fallers indicated that the ability of the elderly to rapidly reorganise the arrangement of the lower limb may play a significant role in allowing the elderly to recover balance after a trip. Thus, training stimulus aimed to improve the rate of torque development may be more beneficial to prevent falls among the elderly than other training stimulus, which are not specifically designed to improve the ability to rapidly produce large amounts of torque (C) 2010 Published by Elsevier Ltd
Resumo:
Background: Falls are one of the greatest concerns among the elderly. Among a number of strategies proposed to reduce the risk of falls, improving muscle strength has been applied as a successful preventive strategy. Although it has been suggested as a relevant strategy, no studies have analyzed how muscle strength improvements affect the gait pattern. The aim of this study was to determine the effects of a lower limb strength training program on gait kinematics parameters associated with the risk of falls in elderly women. Methods: Twenty seven elderly women were assigned in a balance and randomized order into an experimental (n = 14: age = 61.1 (4.3) years, BMI = 26.4 (2.8) kg m(-2)) and a control (n = 13; age = 61.6 (6.6) years; BMI = 25.9 (3.0) kg m(-2)) group. The EG performed lower limb strength training during 12 weeks (3 days per week), being training load increased weekly. Findings: Primary outcomes were gait kinematics parameters and maximum voluntary isometric contractions at pre- and post-training period. Secondary outcomes were training load improvement weekly and one repetition maximum every two weeks. The I maximal repetition increment ranged from 32% to 97% and was the best predictor of changes in gait parameters (spatial, temporal and angular variables) after training for the experimental group. Z-score analysis revealed that the strength training was effective in reversing age-related changes in gait speed, stride length, cadence and toe clearance, approaching the elderly to reference values for healthy young women. Interpretation: Lower limb strength training improves fall-related gait kinematic parameters. Thus, strength training programs should be recommended to the elderly women in order to change their gait pattern towards young adults. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The purpose of the present study was to compare the effects of eight weeks of strength training on fatigue resistance in men and women. Thirty-three men and twenty-three women performed eight weeks of strength training in three weekly sessions. Subjects performed four sets using 80% of 1-RM tests on bench press, squat and arm curl. Fatigue index (FI) was used for analysis of decline in motor performance along the sets. The sum of the number of repetitions accomplished in the four sets in each exercise was used to indicate the fatigue resistance. Anova or Ancova two-way ( time x gender) was employed for statistical analysis ( P < 0.05). Eight weeks of strength training increased significantly 1-RM strength, fatigue resistance and total number of repetitions in both genders. FI decreased significantly in both genders after training ( men = 50% vs. women = Time x gender interaction was observed in the total number of repetitions in squat ( P = 0.04) and arm curl exercises, regarding gains to women ( P = 0.01). In conclusion, eight weeks of ST improved strength, FR, FI and total number of repetitions performed. However, women obtained greater adaptations than men.
Production, microstructural characterization and mechanical properties of as-cast Ti-10Mo-xNb alloys
Resumo:
Beta titanium (Ti) alloys are one of the most promising groups of Ti alloys for biomedical applications. This work presents the production, microstructural characterization, and mechanical properties of as-cast Ti-10Mo-xNb (x = 0, 3, 6, 9, 20, and 30) alloys. They were produced via arc melting and characterized by scanning electron microscopy and X-ray diffraction. The density of each alloy was measured by the Archimedes method and the mechanical characterization was carried out by using the Vickers microhardness test and Young`s modulus measurements. The results show a near beta microstructure for niobium (Nb) contents lower or equal to 9 wt% while beta single-phase microstructure was obtained for higher Nb additions. The microhardness values decreased with the increase of Nb content in the alloys. The elastic modulus values of Ti-10Mo-3Nb and Ti-10Mo-20Nb alloys were lower than those of cp Ti and Ti-6Al-4V.
Resumo:
We assess the performance of three unconditionally stable finite-difference time-domain (FDTD) methods for the modeling of doubly dispersive metamaterials: 1) locally one-dimensional FDTD; 2) locally one-dimensional FDTD with Strang splitting; and (3) alternating direction implicit FDTD. We use both double-negative media and zero-index media as benchmarks.
Resumo:
Research Foundation of the State of Sao Paulo (FAPESP)
Resumo:
State of Sao Paulo Research Foundation (FAPESP)
Resumo:
Generally, quadriplegic individuals have difficulties performing object manipulation. Toward satisfactory manipulation, reach and grasp movements must be performed with voluntary control, and for that, grasp force feedback is essential. A hybrid system aiming at partial upper limb sensory-motor restoration for quadriplegics was built. Such device is composed of an elbow dynamic orthosis that provides elbow flexion/extension (range was approximately from 20 degrees to 120 degrees, and average angular speed was approximately 15 degrees/s) with forearm support, a wrist static orthosis and neuromuscular electrical stimulation for grasping generation, and a glove with force sensors that allows grasping force feedback. The glove presents two user interface modes: visual by light emitting diodes or audio emitted by buzzer. Voice control of the entire system (elbow dynamic orthosis and electrical stimulator) is performed by the patient. The movements provided by the hybrid system, combined with the scapular and shoulder movements performed by the patient, can aid quadriplegic individuals in tasks that involve reach and grasp movements.
Resumo:
The authors present a comparative analysis between a triple-band S-C-L erbium-doped fibre amplifier and a commercial semiconductor optical amplifier in a CWDM application scenario. Both technologies were characterised for gain and noise figures from 1480 to 1610 nm (S, C and L bands) and their systemic performances were evaluated in terms of bit error rate measurements for a wide range of optical power levels.
Resumo:
In the present study, quasi-diabatic two-phase flow pattern visualizations and measurements of elongated bubble velocity, frequency and length were performed. The tests were run for R134a and R245fa evaporating in a stainless steel tube with diameter of 2.32 mm, mass velocities ranging from 50 to 600 kg/m(2) s and saturation temperatures of 22 degrees C, 31 degrees C and 41 degrees C. The tube was heated by applying a direct DC current to its surface. Images from a high-speed video-camera (8000 frames/s) obtained through a transparent tube just downstream the heated sections were used to identify the following flow patterns: bubbly, elongated bubbles, churn and annular flows. The visualized flow patterns were compared against the predictions provided by Barnea et al. (1983) [1], Felcar et al. (2007) [10], Revellin and Thome (2007) [3] and Ong and Thome (2009) [11]. From this comparison, it was found that the methods proposed by Felcar et al. (2007) [10] and Ong and Thome (2009) [1] predicted relatively well the present database. Additionally, elongated bubble velocities, frequencies and lengths were determined based on the analysis of high-speed videos. Results suggested that the elongated bubble velocity depends on mass velocity, vapor quality and saturation temperature. The bubble velocity increases with increasing mass velocity and vapor quality and decreases with increasing saturation temperature. Additionally, bubble velocity was correlated as linear functions of the two-phase superficial velocity. (C) 2010 Elsevier Inc. All rights reserved.