149 resultados para Cost methods
Resumo:
The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE: This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND METHODS: 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). RESULTS: Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. CONCLUSION: Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.
Resumo:
This study compared the mandibular displacement from three methods of centric relation record using an anterior jig associated with (A) chin point guidance, (B) swallowing (control group) and (C) bimanual manipulation. Ten patients aged 25-39 years were selected if they met the following inclusion criteria: complete dentition (up to the second molars), Angle class I and absence of signs and symptoms of temporomandibular disorders and diagnostic casts showing stability in the maximum intercuspation (MI) position. Impressions of maxillary and mandibular arches were made with an irreversible hydrocolloid impression material. Master casts of each patient were obtained, mounted on a microscope table in MI as a reference position and 5 records of each method were made per patient. The mandibular casts were then repositioned with records interposed and new measurements were obtained. The difference between the two readings allowed measuring the displacement of the mandible in the anteroposterior and lateral axes. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) among the three methods for measuring lateral displacement (A=0.38 ± 0.26, B=0.32 ± 0.25 and C=0.32 ± 0.23). For the anteroposterior displacement (A=2.76 ± 1.43, B=2.46 ± 1.48 and C=2.97 ± 1.51), the swallowing method (B) differed significantly from the others (p<0.05), but no significant difference (p>0.05) was found between chin point guidance (A) and bimanual manipulation (C). In conclusion, the swallowing method produced smaller mandibular posterior displacement than the other methods.
Resumo:
Secondary caries has been reported as the main reason for restoration replacement. The aim of this in vitro study was to evaluate the performance of different methods - visual inspection, laser fluorescence (DIAGNOdent), radiography and tactile examination - for secondary caries detection in primary molars restored with amalgam. Fifty-four primary molars were photographed and 73 suspect sites adjacent to amalgam restorations were selected. Two examiners evaluated independently these sites using all methods. Agreement between examiners was assessed by the Kappa test. To validate the methods, a caries-detector dye was used after restoration removal. The best cut-off points for the sample were found by a Receiver Operator Characteristic (ROC) analysis, and the area under the ROC curve (Az), and the sensitivity, specificity and accuracy of the methods were calculated for enamel (D2) and dentine (D3) thresholds. These parameters were found for each method and then compared by the McNemar test. The tactile examination and visual inspection presented the highest inter-examiner agreement for the D2 and D3 thresholds, respectively. The visual inspection also showed better performance than the other methods for both thresholds (Az = 0.861 and Az = 0.841, respectively). In conclusion, the visual inspection presented the best performance for detecting enamel and dentin secondary caries in primary teeth restored with amalgam.
Resumo:
The aim of this study was to assess the Knoop hardness of three high viscous glass ionomer cements: G1 - Ketac Molar; G2 - Ketac Molar Easymix (3M ESPE) and G3 - Magic Glass ART (Vigodent). As a parallel goal, three different methods for insertion of Ketac Molar Easymix were tested: G4 - conventional spatula; G5 - commercial syringe (Centrix) and G6 - low-cost syringe. Ten specimens of each group were prepared and the Knoop hardness was determined 5 times on each specimen with a HM-124 hardness machine (25 g/30 s dwell time) after 24 h, 1 and 2 weeks. During the entire test period, the specimens were stored in liquid paraffin at 37ºC. Significant differences were found between G3 and G1/G2 (two-way ANOVA and Tukey's post hoc test; p<0.01). There was no significant difference in the results among the multiple ways of insertion. The glass ionomer cement Magic Glass ART showed the lowest hardness, while the insertion technique had no significant influence on hardness.
Resumo:
OBJECTIVE: This in situ study evaluated the discriminatory power and reliability of methods of dental plaque quantification and the relationship between visual indices (VI) and fluorescence camera (FC) to detect plaque. MATERIAL AND METHODS: Six volunteers used palatal appliances with six bovine enamel blocks presenting different stages of plaque accumulation. The presence of plaque with and without disclosing was assessed using VI. Images were obtained with FC and digital camera in both conditions. The area covered by plaque was assessed. Examinations were done by two independent examiners. Data were analyzed by Kruskal-Wallis and Kappa tests to compare different conditions of samples and to assess the inter-examiner reproducibility. RESULTS: Some methods presented adequate reproducibility. The Turesky index and the assessment of area covered by disclosed plaque in the FC images presented the highest discriminatory powers. CONCLUSION: The Turesky index and images with FC with disclosing present good reliability and discriminatory power in quantifying dental plaque.
Resumo:
Gaseous N losses from soil are considerable, resulting mostly from ammonia volatilization linked to agricultural activities such as pasture fertilization. The use of simple and accessible measurement methods of such losses is fundamental in the evaluation of the N cycle in agricultural systems. The purpose of this study was to evaluate quantification methods of NH3 volatilization from fertilized surface soil with urea, with minimal influence on the volatilization processes. The greenhouse experiment was arranged in a completely randomized design with 13 treatments and five replications, with the following treatments: (1) Polyurethane foam (density 20 kg m-3) with phosphoric acid solution absorber (foam absorber), installed 1, 5, 10 and 20 cm above the soil surface; (2) Paper filter with sulfuric acid solution absorber (paper absorber, 1, 5, 10 and 20 cm above the soil surface); (3) Sulfuric acid solution absorber (1, 5 and 10 cm above the soil surface); (4) Semi-open static collector; (5) 15N balance (control). The foam absorber placed 1 cm above the soil surface estimated the real daily rate of loss and accumulated loss of NH3N and proved efficient in capturing NH3 volatized from urea-treated soil. The estimates based on acid absorbers 1, 5 and 10 cm above the soil surface and paper absorbers 1 and 5 cm above the soil surface were only realistic for accumulated N-NH3 losses. Foam absorbers can be indicated to quantify accumulated and daily rates of NH3 volatilization losses similarly to an open static chamber, making calibration equations or correction factors unnecessary.
Resumo:
OBJETIVOS: Descrever as características clínicas e laboratoriais dos pacientes em oxigenoterapia domiciliar prolongada acompanhados pelo programa de atendimento domiciliar do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, durante um período de 8 anos, e comparar os grupos com e sem hipertensão pulmonar secundária. Estimar o custo do programa utilizando concentradores versus cilindros de oxigênio arcados pela instituição. MÉTODOS: Estudo descritivo retrospectivo e de coorte dos pacientes em oxigenoterapia domiciliar prolongada, em seguimento no período de 2002 a 2009, na Unidade de Pneumologia do Instituto da Criança do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. RESULTADOS: Foram estudados 165 pacientes, 53% do sexo masculino, com as medianas: idade de início da oxigenoterapia - 3,6 anos; tempo de oxigenoterapia - 7 anos; e tempo de sobrevida após início da oxigenoterapia - 3,4 anos. Os principais diagnósticos foram: fibrose cística (22%), displasia broncopulmonar (19%) e bronquiolite obliterante (15%). Dos 33 pacientes que realizaram espirometria, 70% apresentavam distúrbio ventilatório obstrutivo grave. O exame ecocardiográfico foi executado em 134 pacientes; 51% deles tinham hipertensão pulmonar secundária. Houve associação estatisticamente significante entre: presença de hipertensão pulmonar e necessidade de maiores fluxos de oxigênio (qui-quadrado, p = 0,011); e presença de hipertensão pulmonar e maior tempo de oxigenoterapia (Logrank, p = 0,0001). Não houve diferença estatisticamente significante entre tempo de sobrevida após início da oxigenoterapia e presença de hipertensão pulmonar. Os custos médios mensais do programa foram: US$ 7.392,93 para os concentradores e US$ 16.630,92 para cilindros. CONCLUSÕES: A oxigenoterapia domiciliar prolongada foi empregada em distintas doenças crônicas, predominantemente em lactentes e pré-escolares. Houve alta frequência de hipertensão pulmonar associada a maiores períodos de uso e fluxos de oxigênio, sem associação à sobrevida. A substituição dos cilindros por concentradores poderá reduzir custos significativamente.
Resumo:
Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency's technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.
Resumo:
The naturally occurring clonal diversity among field isolates of the major human malaria parasite Plasmodium vivax remained unexplored until the early 1990s, when improved molecular methods allowed the use of blood samples obtained directly from patients, without prior in vitro culture, for genotyping purposes. Here we briefly review the molecular strategies currently used to detect genetically distinct clones in patient-derived P. vivax samples, present evidence that multiple-clone P. vivax infections are commonly detected in areas with different levels of malaria transmission and discuss possible evolutionary and epidemiological consequences of the competition between genetically distinct clones in natural human infections. We suggest that, when two or more genetically distinct clones are present in the same host, intra-host competition for limited resources may select for P. vivax traits that represent major public health challenges, such as increased virulence, increased transmissibility and antimalarial drug resistance.
Resumo:
La comunidad científica que se ocupa de los problemas relacionados con el proceso de enseñanza-aprendizaje de la físicas, ha dedicado muchos esfuerzos en los ultimos años al perfeccionamiento del mismo, motivado en primera instancia, por las demandas de renovación que el impetuoso desarrollo científico-técnico le impone en la actualidad a la enseñanza de las ciencias. En los últimos años se ha producido un desarrollo vertiginoso en la fabricación de diodos láser que emiten en el espectro visible, esto ha permitido su utilización creciente en múltiples aplicaciones y hace factible su utilización en la enseñanza aprendizaje de la física universitaria y en particular de la holografía, por sus grandes ventajas frente a los láseres convencionales de gran costo y difícil manipulación. En el trabajo se describen la instalación experimental portátil diseñada para la obtención de hologramas en la escuela y en la casa con la utilización de diodos láser, la metodología de trabajo a seguir, los métodos de procesamiento utilizados para diferentes tipos de emulsiones holográficas y un análisis de los defectos que pueden presentar los hologramas producidos y la forma de detectarlos y erradicarlos
Resumo:
The increasing demand for fatty acid-free lecithin required modifications in existing purification methods. In this technical note we describe a purification procedure with the following steps: a) homogenization and extraction of yolks obtained from fresh eggs with acetone, b) solubilization with ethanol and solvent elimination and c) repeated solubilization/precipitation with petroleum ether/acetone. This crude extract was chromatographed on neutral alumina, which was exhaustively washed with chloroform before elution with chloroform:methanol, allowing the sequential separation of fatty acids and lecithin. Chromatographic behavior and mass spectra of the product are presented. This fast procedure yields fatty acid-free lecithin at a competitive cost.
Resumo:
OBJETIVO: Avaliar o programa de imunização de crianças de 12 e de 24 meses de idade, com base no registro informatizado de imunização. MÉTODOS: Estudo descritivo em amostra probabilística de 2.637 crianças nascidas em 2002 e residentes em Curitiba, PR. As fontes de dados foram: registro informatizado de imunização do município, Sistema de Informação de Nascidos Vivos e inquérito domiciliar para casos com registro incompleto. As coberturas foram estimadas aos 12 e aos 24 meses de vida e analisadas segundo características socioeconômicas de cada distrito sanitário e o vínculo das crianças aos serviços de saúde. Foram analisadas a abrangência, completude e duplicidades do registro informatizado de imunização. RESULTADOS: A cobertura do esquema de imunização foi de 95,3% aos 12 meses sem diferenças entre os distritos e de 90,3% aos 24 meses, tendo sido mais elevada em um distrito com piores indicadores socioeconômicos (p = 0,01). A proporção de vacinas, segundo o tipo, aplicadas antes e após a idade recomendada foi de até 0,9% e até 32,2%, respectivamente. A cobertura do registro informatizado de imunização foi de 98% na amostra estudada, o sub-registro de doses de vacinas foi de 11% e a duplicidade de registro foi de 20,6%. Os grupos que apresentaram maiores coberturas foram: crianças com cadastro definitivo, aquelas com três ou mais consultas pelo Sistema Único de Saúde e as atendidas em Unidades Básicas de Saúde que adotam plenamente a Estratégia de Saúde da Família. CONCLUSÕES: A cobertura vacinal em Curitiba mostrou-se elevada e homogênea entre os distritos, e o vínculo com os serviços de saúde foi fator importante para tais resultados. O registro informatizado de imunização mostrou-se útil no monitoramento da cobertura vacinal; no entanto, é importante a prévia avaliação do seu custo-efetividade para que seja amplamente utilizado pelo Programa Nacional de Imunização.
Resumo:
OBJETIVO: Analisar a acurácia do diagnóstico de dois protocolos de imunofluorescência indireta para leishmaniose visceral canina. MÉTODOS: Cães provenientes de inquérito soroepidemiológico realizado em área endêmica nos municípios de Araçatuba e de Andradina, na região noroeste do estado de São Paulo, em 2003, e área não endêmica da região metropolitana de São Paulo, foram utilizados para avaliar comparativamente dois protocolos da reação de imunofluorescência indireta (RIFI) para leishmaniose: um utilizando antígeno heterólogo Leishmania major (RIFI-BM) e outro utilizando antígeno homólogo Leishmania chagasi (RIFI-CH). Para estimar acurácia utilizou-se a análise two-graph receiver operating characteristic (TG-ROC). A análise TG-ROC comparou as leituras da diluição 1:20 do antígeno homólogo (RIFI-CH), consideradas como teste referência, com as diluições da RIFI-BM (antígeno heterólogo). RESULTADOS: A diluição 1:20 do teste RIFI-CH apresentou o melhor coeficiente de contingência (0,755) e a maior força de associação entre as duas variáveis estudadas (qui-quadrado=124,3), sendo considerada a diluição-referência do teste nas comparações com as diferentes diluições do teste RIFI-BM. Os melhores resultados do RIFI-BM foram obtidos na diluição 1:40, com melhor coeficiente de contingência (0,680) e maior força de associação (qui-quadrado=80,8). Com a mudança do ponto de corte sugerido nesta análise para a diluição 1:40 da RIFI-BM, o valor do parâmetro especificidade aumentou de 57,5% para 97,7%, embora a diluição 1:80 tivesse apresentado a melhor estimativa para sensibilidade (80,2%) com o novo ponto de corte. CONCLUSÕES: A análise TG-ROC pode fornecer importantes informações sobre os testes de diagnósticos, além de apresentar sugestões sobre pontos de cortes que podem melhorar as estimativas de sensibilidade e especificidade do teste, e avaliá-los a luz do melhor custo-benefício.
Resumo:
O cálcio é um nutriente essencial necessário em diversas funções biológicas. Estudos têm demonstrado a associação entre o baixo consumo de cálcio e doenças crônicas, entre elas osteoporose, câncer de colón, hipertensão arterial e obesidade. Entretanto, grande parte da população brasileira apresenta consumo de cálcio abaixo do recomendado. Este artigo objetiva revisar os fatores endógenos (idade e estado hormonal) e exógenos (fitatos, oxalatos, sódio, compostos bioativos e vitamina D) que influenciam a absorção do cálcio, bem como as principais metodologias utilizadas para avaliar a absorção e biodisponibilidade desse nutriente. Discorre-se sobre os possíveis fatores para o baixo consumo de cálcio: 1) Hábito alimentar - substituição de leite por bebidas com baixo teor de cálcio como o refrigerante, refeições realizadas fora de casa e a não realização de refeições como o café da manhã; 2) Alto custo dos alimentos fontes de cálcio. Além disso, este artigo discute as estratégias para otimizar o consumo do cálcio, que incluem: 1) Aumentar o conhecimento sobre a importância do consumo de cálcio para a saúde e as principais fontes alimentares desse nutriente; 2) Aumentar a disponibilidade de alimentos fortificados com cálcio; 3) Uso de suplementos em grupos específicos - quando e como administrar os sais de cálcio.