276 resultados para CR 864.4 R741u


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An integrated whole-rock petrographic and geochemical study has been carried out on kamafugites and kimberlites of the Late Cretaceous Alto Paranaiba igneous province, in Brazil, and their main minerals, olivine, clinopyroxene, perovskite, phlogopite, spinels and ilmenite. Perovskite is by far the dominant repository for light lanthanides, Nb, Ta, Th and U, and occasionally other elements, reaching concentrations up to 3.4 x 10(4) chondrite values for light lanthanides and 105 chondrite for Th. A very strong fractionation between light and heavy lanthanides (chondrite-normalized La/Yb from similar to 175 to similar to 2000) is also observed. This is likely the first comprehensive dataset on natural perovskite. Clinopyroxene has variable trace-element contents. likely due to the different position of this phase in the crystallization sequence; Sc reaches values as high as 200 ppm whereas the lanthanides show very variable enrichment in light over heavy REE, and commonly show a negative Eu anomaly. The olivine, phlogopite (and tetra-ferriphlogopite), Cr-Ti oxide and ilmenite are substantially barren minerals for lanthanides and most other trace elements, with the exception of Ba, Cs and Rb in mica, and V, Nb and Ta in ilmenite. Estimated mineral/whole-rock partition coefficients for lanthanides in perovskite are similar to previous determinations, though much higher than those calculated in experiments with synthetic compositions, testifying once more to the complex behavior of these elements in a natural environment. The enormous potential for exploitation of lanthanides, Th, U and high-field-strength elements in the Brazilian kamafugites, kimberlites and related rocks is clearly shown.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In situ fusion on the boat-type graphite platform has been used as a sample pretreatment for the direct determination of Co, Cr and Mn in Portland cement by solid sampling graphite furnace atomic absorption spectrometry (SS-GF AAS). The 3-field Zeeman technique was adopted for background correction to decrease the sensitivity during measurements. This strategy allowed working with up to 200 mu g of sample. The in situ fusion was accomplished using 10 mu L of a flux mixture 4.0% m/v Na(2)CO(3) + 4.0% m/v ZnO + 0.1% m/v Triton (R) X-100 added over the cement sample and heated at 800 degrees C for 20 s. The resulting mould was completely dissolved with 10 mu L of 0.1% m/v HNO(3). Limits of detection were 0.11 mu g g(-1) for Co, 1.1 mu g g(-1) for Cr and 1.9 mu g g(-1) for Mn. The accuracy of the proposed method has been evaluated by the analysis of certified reference materials. The values found presented no statistically significant differences compared to the certified values (Student`s t-test, p<0.05). In general, the relative standard deviation was lower than 12% (n = 5). (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey's post-hoc test (p<0.05). RESULTS: Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. CONCLUSIONS: The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: investigar o conhecimento dos professores de 1ª a 4ª série quanto ao distúrbio da leitura e escrita, pesquisando quais dificuldades referentes a esse distúrbio, foram apresentadas por estes professores. MÉTODOS: esses dados foram obtidos, por meio de um questionário informativo de 10 questões, aplicados a 50 professores de 1ª a 4ª série, da cidade de Bauru. Os questionários foram analisados e tabulados, e receberam tratamento estatístico pertinente. RESULTADOS: os resultados obtidos revelaram que os professores possuem um conhecimento superficial a respeito do distúrbio da leitura e escrita, sendo que muitos adquiriram tal conhecimento fora do ambiente de graduação. Verificou-se também que os professores apesar de encaminharem seus alunos ao fonoaudiólogo, possuem visão limitada quanto à atuação deste profissional. O distúrbio da leitura e escrita foi considerado como um problema próprio da criança, sendo pouco reconhecido como uma falha que também pode ser da escola ou da metodologia de ensino. CONCLUSÃO: os professores logram um saber pouco fundamentado a respeito do distúrbio da leitura e escrita; sendo que, as dificuldades giraram em torno: da identificação real do problema; de quais manifestações caracterizam esse problema; e de como intervir e prevenir.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most important properties of artificial teeth is the abrasion wear resistance, which is determinant in the maintenance of the rehabilitation's occlusal pattern. OBJECTIVES: This in vitro study aims to evaluate the abrasion wear resistance of 7 brands of artificial teeth opposed to two types of antagonists. MATERIAL AND METHODS: Seven groups were prepared with 12 specimens each (BIOLUX & BL, TRILUX & TR, BLUE DENT & BD, BIOCLER & BC, POSTARIS & PO, ORTHOSIT & OR, GNATHOSTAR & GN), opposed to metallic (M & nickel-chromium alloy), and to composite antagonists (C & Solidex indirect composite). A mechanical loading device was used (240 cycles/min, 4 Hz speed, 10 mm antagonist course). Initial and final contours of each specimen were registered with aid of a profile projector (20x magnification). The linear difference between the two profiles was measured and the registered values were subjected to ANOVA and Tukey's test. RESULTS: Regarding the antagonists, only OR (M = 10.45 ± 1.42 µm and C = 2.77 ± 0.69 µm) and BC (M = 6.70 ± 1.37 µm and C = 4.48 ± 0.80 µm) presented statistically significant differences (p < 0.05). Best results were obtained with PO (C = 2.33 ± 0.91 µm and M = 1.78 ± 0.42 µm), followed by BL (C = 3.70 ± 1.32 µm and M = 3.70 ± 0.61 µm), statistically similar for both antagonists (p>0.05). Greater result variance was obtained with OR, which presented the worse results opposed to Ni-Cr (10.45 ± 1.42 µm), and results similar to the best ones against composite (2.77 ± 0.69 µm). CONCLUSIONS: Within the limitations of this study, it may be concluded that the antagonist material is a factor of major importance to be considered in the choice of the artificial teeth to be used in the prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Removable partial dentures (RPD) demand specific hygienic cleaning and the combination of brushing with immersion in chemical solutions has been the most recommended method for control of biofilm. However, the effect of the cleansers on metallic components has not been widely investigated. This study evaluated the effect of different cleansers on the surface of RPD. Five disc specimens (12 mm x 3 mm metallic disc centered in a 38 x 18 x 4 mm mould filled with resin) were obtained for each experimental situation: 6 solutions [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) control] and 2 Co-Cr alloys [DeguDent (DD) and VeraPDI (VPDI)] were used for each experimental situation. A 180-day immersion was simulated and the measurements of roughness (Ra, µm) of metal and resin were analyzed using 2-way ANOVA and Tukey’s test. The surface changes and tarnishes were examined with a scanning electronic microscopy (SEM). In addition, energy dispersive x-ray spectrometry (EDS) analysis was carried out at representative areas. Visually, NaOCl and MI specimens presented surface tarnishes. The roughness of materials was not affected by the solutions (p>0.05). SEM images showed that NaOCl and MI provided surface changes. EDS analysis revealed the presence of oxygen for specimens in contact with both MI and NaOCl solutions, which might suggest that the two solutions promoted the oxidation of the surfaces, thus leading to spot corrosion. Within the limitations of this study, it may be concluded that the NaOCl and MI may not be suitable for cleaning of RPD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The success of metal-ceramic restorations depends on an optimal bond between metal and ceramic. This study evaluated the effect of 3 casting atmospheres on the metal-ceramic bond strength (MCBS) of 2 Ni-Cr alloys, with beryllium (Fit Cast V) and without beryllium (Fit Cast SB). Sixty acrylic resin patterns (8 mm long and 5 mm diameter) were obtained using a fluorocarbon resin matrix. Wax was used to refine the surface of acrylic resin patterns that were invested and cast in an induction casting machine under normal, vacuum, and argon atmospheres at a temperature of 1340ºC. The castings were divested manually and airborne-particle abraded with 100-µm aluminum-oxide. Ten castings were obtained for each group. The IPS Classic V ceramic was applied (2 mm high and 5 mm diameter). The shear bond strength was tested in a mechanical testing machine with a crosshead speed of 2.0 mm/min. The MCBS data (MPa) were subjected to 2-way analysis of variance (α=0.05). There was no statistically significant difference (p>0.05) between the alloys or among the casting atmospheres. Within the limitations of this study, it may be concluded that the presence of beryllium and the casting atmosphere did not interfere in the MCBS of the evaluated metal-ceramic combinations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shiga toxigenic Escherichia coli (STEC) and Attaching and effacing E. coli (AEEC) have been associated with diarrhea illness in dogs. From January to December 2006, 92 E. coli isolates from 25 diarrheic dogs were analyzed, by screening for the presence of Shiga toxin-producing (stx 1 and stx 2) and intimin (eae) genes. Twelve isolates were detected by PCR to harbor the Shiga toxin genes (7 the stx 1 (7.6%); 5 the stx 2 (5.4%); and none both of them). Nine (9.8%) of the E. coli isolates studied were eae positive non Shiga toxin-producing. Thirteen (62.0%) isolates, carrying stx or eae gene, also showed a hemolysin production. The strains with virulence genes were also examined for resistance to 12 antimicrobial agents. Resistances to cephalothin (85.7%), streptomycin (81.0%), amoxicillin (71.4%) and gentamicin (71.4%) were predominantly observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have shown the cariostatic effect of Er,Cr:YSGG (2.78 mm) laser irradiation on human enamel and have suggested its use on caries prevention. However there are still no reports on the intrapulpal temperature increase during enamel irradiation using parameters for caries prevention. The aim of this in vitro study was to evaluate the temperature variation in the pulp chamber during human enamel irradiation with Er,Cr:YSGG laser at different energy densities. Fifteen enamel blocks obtained from third molars (3 x 3 x 3 mm) were randomly assigned to 3 groups (n=5): G1 - Er,Cr:YSGG laser 0.25 W, 20 Hz, 2.84 J/cm², G2 - Er,Cr:YSGG laser 0.50 W, 20 Hz, 5.68 J/cm², G3 - Er,Cr:YSGG laser 0.75 W, 20 Hz, 8.52 J/cm². During enamel irradiation, two thermocouples were fixed in the inner surface of the specimens and a thermal conducting paste was used. One-way ANOVA did not show statistically significant difference among the experimental groups (a=0.05). There was intrapulpal temperature variation <0.1ºC for all irradiation parameters. In conclusion, under the tested conditions, the use of Er,Cr:YSGG laser with parameters set for caries prevention lead to an acceptable temperature increase in the pulp chamber.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed at comparing amounts of nickel (Ni) and chromium (Cr) released from brackets from different manufacturers in simulated oral environments. 280 brackets were equally divided into 7 groups according to manufacturer. 6 groups of brackets were stainless steel, and 1 group of brackets was made of a cobalt-chromium alloy with low Ni content (0.5%). International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 ml of synthetic saliva (SS) or artificial plaque fluid (PF) over a period of 28 days at 37ºC. Solutions were replaced every 7 days, and were analyzed by spectrometry. The Kruskal-Wallis test was applied. Amounts of Ni release in SS (µg L-1 per week) varied between groups from "bellow detection limits" to 694, and from 49 to 5,948.5 in PF. The group of brackets made of cobalt-chromium alloy, with the least nickel content, did not release the least amounts of Ni. Amounts of Cr detected in SS and in PF (µg L-1 per week) were from 1 to 10.4 and from 50.5 to 8,225, respectively. It was therefore concluded that brackets from different manufacturers present different corrosion behavior. Further studies are necessary to determine clinical implications of the findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O tratamento convencionalmente preconizado para cães acometidos pela CMD consiste na prescrição de vasodilatadores, agentes inotrópicos positivos (digitálico), diuréticos, dieta hipossódica e, quando necessário, antiarrítmicos. O carvedilol é um β-bloqueador de 3ª geração, não seletivo, que bloqueia igualmente e competitivamente os receptores (β1, β2 e α1). Produz uma evidente vasodilatação periférica, exerce efeitos anti-oxidantes, removendo radicais livres de oxigênio e prevenindo a peroxidação lipídica nas membranas cardíacas, prevenindo a perda de miócitos e a ocorrência de arritmias e reduzindo a taxa de mortalidade em pacientes humanos. O objetivo do presente estudo foi avaliar clínica, eletrocardiográfica, radiográfica e ecocardiograficamente a evolução de cães com cardiomiopatia dilatada (CMD) tratatos com terapia convencional associada ao carvedilol. Para tal foram avaliados 49 cães com CMD divididos em: grupo NT, tratado com terapia convencional, e grupo T, tratado com terapia convencional associada ao carvedilol. Os animais foram submetidos à avaliação clínica e a exames complementares durante o período de um ano. Os resultados demonstraram que a terapia com carvedilol apresentou boa tolerabilidade na dose de 0,3mg kg-1 12-12horas, aumentou a sobrevida dos cães em 30,9%, não alterou as pressões sistólica e diastólica, reduziu a frequência cardíaca após três semanas de terapia, melhorou significantemente as frações de encurtamento e ejeção após seis meses de tratamento, não promoveu alterações radiográficas e da distância E-septo, diminuiu o índice de letalidade da doença, fato demonstrado pela melhora no escore clínico e na classe funcional dos animais, obtida após três semanas de terapia com carvedilol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo objetivou caracterizar a presença de pneumócitos tipo II e o início da produção de lipoproteína surfactante em bovinos, correlacionando a idade gestacional com a síntese de surfactante durante o desenvolvimento fetal. Pulmões de fetos com quatro meses de idade gestacional estavam na fase canalicular de desenvolvimento, sem a presença de pneumócitos tipo II ou bandas eletroforéticas compatíveis com a presença de proteínas surfactante. No 5° mês gestacional, os pulmões dos fetos encontravam-se em fase de saculação terminal, com a presença de alvéolos por epitélio cúbico, com áreas formadas por pneumócitos I e II. Nesse período ainda não foi possível identificar proteína surfactante nos pulmões. Esses órgãos em fetos com seis meses de idade gestacional estavam em fase de saco terminal, com presença de pneumócitos tipo I e II. Nessa fase a análise para determinação protéica do surfactante de feto bovino (SDS - PAGE) demonstrou presença de bandas entre 26 e 36kDa, confirmando produção de SP - A, proteína surfactante encontrada em maior quantidade. A partir do 7° mês gestacional, a fase de saco terminal é mais evidente e complexa, com desenvolvimento de intensa vascularização. O pneumócito tipo I apresentava aspecto mais pavimentoso, e o tipo II apresentava aspecto mais globoso. Na análise SDS - PAGE do lavado bronco - alveolar, bandas de proteína surfactante com aspecto similar ao de animais recém-nascidos foram encontradas. Em recém-nascidos, pulmões na fase alveolar foram observados com pneumócitos tipo I e II característicos. O perfil das bandas do lavado bronco-alveolar dos recém-nascidos foi igual ao de animais adultos. Esses achados sugerem que um animal nascido precocemente, a partir dos sete meses de gestação, teria sua sobrevivência garantida devido a uma possível funcionalidade do sistema respiratório do feto, pois o pulmão possuiria as características necessárias para a síntese de proteínas surfactantes. Entretanto, mais estudos clínicos sobre a funcionalidade do sistema respiratório abrem novas fronteiras de experimentos sobre fisiologia respiratória em recém-nascidos bovinos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Para avaliar o efeito anestésico do óleo de cravo em lambaris (Astyanax altiparanae), cinco grupos de 30 alevinos (0,6±0,1g) foram expostos às concentrações de 50, 75, 100, 125 e 150mg L-1, medindo-se, respectivamente: tempo de indução à anestesia profunda (caracterizada pela perda de equilíbrio, pela ausência de natação, pela redução dos movimentos operculares e pelas respostas apenas a estímulos táteis mais intensos), tempo de recuperação e taxa de mortalidade após a exposição. Em uma segunda etapa (10 peixes/tratamento), registraram-se, para cada concentração, os tempos de indução e de recuperação após anestesia cirúrgica (movimentos operculares lentos e irregulares e perda de reações a estímulos), anotando-se a mortalidade após seis minutos de exposição. Observou-se redução linear no tempo de indução à anestesia (0,01min mg-1 de anestésico acrescido) e aumento quadrático do tempo de recuperação com a elevação da concentração (resposta máxima estimada em 7,1 minutos). A anestesia profunda foi alcançada em tempo inferior a 1,5 minuto para todas as concentrações, com recuperação mais rápida e sem mortalidade para 50mg L-1. Para indução à anestesia cirúrgica, foram registrados menores tempos nas concentrações 75 e 100mg L-1; porém, com mortalidade de 80% e 100%, respectivamente. A concentração 50mg L-1 promoveu anestesia cirúrgica e recuperação em 3,29±0,71 e 4,97±0,63 minutos, respectivamente, sem mortalidade. Concluiu-se que o óleo de cravo possui efeito anestésico para alevinos de lambari, sendo 50mg L-1 a concentração eficiente e segura para indução à anestesia profunda em até 1,5 minuto e de anestesia cirúrgica em até 3,3 minutos de exposição.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avaliaram-se os efeitos do fornecimento da dieta pré-inicial (DPI) e do peso ao alojamento sobre o desempenho e as características de carcaça de frangos de corte. Utilizaram-se 960 frangos machos, linhagem comercial Cobb-500, alojados em 32 boxes, em um delineamento inteiramente casualizado em esquema fatorial 2 x 4, composto de dois pesos ao alojamento (42 e 46 g) e quatro períodos de fornecimento da dieta pré-inicial (0, 1 a 7, 1 a 10 e 1 a 14 dias de idade), durante 49 dias. Os programas alimentares compreenderam três ou quatro fases (pré-inicial e/ou inicial; engorda; final) e as dietas fornecidas eram à base de milho e farelo de soja. De modo geral, aves mais pesadas ao alojamento apresentaram, ao longo de todo o período experimental, maior consumo de ração (CR) e ganho de peso (GP). Não foram observadas diferenças significativas na conversão alimentar (CA) dos animais. Considerando todo o período experimental, as aves alimentadas com a dieta pré-inicial durante sete dias apresentaram maior consumo de ração e ganho de peso, porém, menor rendimento de carcaça. O peso ao alojamento determina o desempenho e o oferecimento da dieta pré-inicial durante sete dias beneficia o desempenho das aves.