169 resultados para CD exciton chirality method
Resumo:
The aim of this study was to assess the Knoop hardness of three high viscous glass ionomer cements: G1 - Ketac Molar; G2 - Ketac Molar Easymix (3M ESPE) and G3 - Magic Glass ART (Vigodent). As a parallel goal, three different methods for insertion of Ketac Molar Easymix were tested: G4 - conventional spatula; G5 - commercial syringe (Centrix) and G6 - low-cost syringe. Ten specimens of each group were prepared and the Knoop hardness was determined 5 times on each specimen with a HM-124 hardness machine (25 g/30 s dwell time) after 24 h, 1 and 2 weeks. During the entire test period, the specimens were stored in liquid paraffin at 37ºC. Significant differences were found between G3 and G1/G2 (two-way ANOVA and Tukey's post hoc test; p<0.01). There was no significant difference in the results among the multiple ways of insertion. The glass ionomer cement Magic Glass ART showed the lowest hardness, while the insertion technique had no significant influence on hardness.
Resumo:
A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.
Resumo:
The fluid flow over bodies with complex geometry has been the subject of research of many scientists and widely explored experimentally and numerically. The present study proposes an Eulerian Immersed Boundary Method for flows simulations over stationary or moving rigid bodies. The proposed method allows the use of Cartesians Meshes. Here, two-dimensional simulations of fluid flow over stationary and oscillating circular cylinders were used for verification and validation. Four different cases were explored: the flow over a stationary cylinder, the flow over a cylinder oscillating in the flow direction, the flow over a cylinder oscillating in the normal flow direction, and a cylinder with angular oscillation. The time integration was carried out by a classical 4th order Runge-Kutta scheme, with a time step of the same order of distance between two consecutive points in x direction. High-order compact finite difference schemes were used to calculate spatial derivatives. The drag and lift coefficients, the lock-in phenomenon and vorticity contour plots were used for the verification and validation of the proposed method. The extension of the current method allowing the study of a body with different geometry and three-dimensional simulations is straightforward. The results obtained show a good agreement with both numerical and experimental results, encouraging the use of the proposed method.
Resumo:
The mineralogical characterization through mineral quantification of Brazilian soils by X-ray diffraction data using the Rietveld Method is not common. A mineralogical quantification of an Acric Ferralsol from the Ponta Grossa region, state of Paraná, Brazil, was carried out using this Method with X-Ray Diffraction data to verify if this method was suitable for mineral quantification of a highly-weathered soil. The A, AB and B3 horizons were fractioned to separate the different particle sizes: clay, silt, fine sand (by Stokes Law) and coarse sand fractions (by sieving), with the procedure free of chemical treatments. X-ray Fluorescence, Inductively Coupled Plasma Atomic Emission Spectrometry, Infrared Spectroscopy and Mössbauer Spectroscopy were used in order to assist the mineral identification and quantification. The Rietveld Method enabled the quantification of the present minerals. In a general way, the quantitative mineralogical characterization by the Rietveld Method revealed that quartz, gibbsite, rutile, hematite, goethite, kaolinite and halloysite were present in the clay and silt fractions of all horizons. The silt fractions of the deeper horizons were different from the more superficial ones due to the presence of large amounts of quartz. The fine and the coarse sand fractions are constituted mainly by quartz. Therefore, a mineralogical quantification of the finer fraction (clay and silt) by the Rietveld Method was successful.
Resumo:
OBJETIVO: Desenvolver um método e um dispositivo para quantificar a visão em candela (cd). Os estudos de medida da visão são importantes para todas as ciências visuais. MÉTODOS: É um estudo teórico e experimental. Foram descritos os detalhes do método psicofísico e da calibração do dispositivo. Foram realizados testes preliminares em voluntários. RESULTADOS: É um teste psicofísico simples e com resultado expresso em unidades do sistema internacional de medidas. Com a descrição técnica será possível reproduzir o experimento em outros centros de pesquisa. CONCLUSÃO: Os resultados aferidos em intensidade luminosa (cd) são uma opção para estudo visual. Esses resultados possibilitarão extrapolar medidas para modelos matemáticos e para simular efeitos individuais com dados aberrométricos.
Resumo:
O objetivo deste trabalho foi medir curvas de sensibilidade ao contraste de 10 crianças ouvintes e de 10 crianças com surdez pré-lingual, de 7 a 12 anos, utilizando frequências radiais circularmente concêntricas (FSCr) de 0,25-2,0 cpg em níveis baixos de luminância (0,7 cd/m²). Todos os participantes apresentavam acuidade visual normal e estavam livres de doenças oculares identificáveis. A FSCr foi medida com o método psicofísico da escolha forçada. Os resultados mostraram sensibilidade máxima na faixa de frequência radial de 0,25 cpg para os dois grupos. Os resultados mostraram ainda diferenças significantes entre as curvas de FSCr de crianças ouvintes e de crianças com surdez pré-lingual. Isto é, as crianças ouvintes precisaram de menos contraste do que as crianças surdas para detectar as frequências radiais. Esses resultados sugerem que, em níveis baixos de luminância, a FSCr das crianças ouvintes foi melhor do que a das crianças com surdez pré-lingual.
Resumo:
We measured the effects of epilepsy on visual contrast sensitivity to linear and vertical sine-wave gratings. Sixteen female adults, aged 21 to 50 years, comprised the sample in this study, including eight adults with generalized tonic-clonic seizure-type epilepsy and eight age-matched controls without epilepsy. Contrast threshold was measured using a temporal two-alternative forced-choice binocular psychophysical method at a distance of 150 cm from the stimuli, with a mean luminance of 40.1 cd/m². A one-way analysis of variance (ANOVA) applied to the linear contrast threshold showed significant differences between groups (F[3,188] = 14.829; p < .05). Adults with epilepsy had higher contrast thresholds (1.45, 1.04, and 1.18 times for frequencies of 0.25, 2.0, and 8.0 cycles per degree of visual angle, respectively). The Tukey Honestly Significant Difference post hoc test showed significant differences (p < .05) for all of the tested spatial frequencies. The largest difference between groups was in the lowest spatial frequency. Therefore, epilepsy may cause more damage to the neural pathways that process low spatial frequencies. However, epilepsy probably alters both the magnocellular visual pathway, which processes low spatial frequencies, and the parvocellular visual pathway, which processes high spatial frequencies. The experimental group had lower visual contrast sensitivity to all tested spatial frequencies.
Resumo:
This work describes methods for the simultaneous determination of Cd and Pb by graphite furnace atomic absorption spectrometry and As by hydride generation atomic absorption spectrometry in Brazilian nuts. The samples (~ 0.300 g) were digested to clear solutions in a closed vessel microwave oven. The pyrolysis and atomization temperatures for simultaneous determinations of Cd and Pb were 1100 and 2100 °C, respectively, using 0.5% (w v-1) NH4H2PO4 + 0.03% (w v-1) Mg(NO3)2 as chemical modifier. The limits of detection (3Δ) were 3.8 μg kg-1 for As, 0.86 μg kg-1 for Cd and 13 μg kg-1 for Pb. The reliability of the entire procedures was confirmed by peach leaves (No. 1547 - NIST) certified reference material analysis and addition and recovery tests. The found concentrations presented no statistical differences at the 95% confidence level.
Resumo:
The increasing demand for fatty acid-free lecithin required modifications in existing purification methods. In this technical note we describe a purification procedure with the following steps: a) homogenization and extraction of yolks obtained from fresh eggs with acetone, b) solubilization with ethanol and solvent elimination and c) repeated solubilization/precipitation with petroleum ether/acetone. This crude extract was chromatographed on neutral alumina, which was exhaustively washed with chloroform before elution with chloroform:methanol, allowing the sequential separation of fatty acids and lecithin. Chromatographic behavior and mass spectra of the product are presented. This fast procedure yields fatty acid-free lecithin at a competitive cost.
Resumo:
A simple and fast capillary zone electrophoresis (CZE) method has been developed and validated for quantification of a non-nucleoside reverse transcriptase inhibitor (NNRTI) nevirapine, in pharmaceuticals. The analysis was optimized using 10 mmol L-1 sodium phosphate buffer pH 2.5, +25 kV applied voltage, hydrodynamic injection 0.5 psi for 5 s and direct UV detection at 200 µm. Diazepam (50.0 µg mL-1) was used as internal standard. Under these conditions, nevirapine was analyzed in approximately less than 2.5 min. The analytical curve presented a coefficient of correlation of 0.9994. Limits of detection and quantification were 1.4 µg mL-1 and 4.3 µg mL-1, respectively. Intra- and inter-day precision expressed as relative standard deviations were 1.4% and 1.3%, respectively and the mean recovery was 100.81%. The active pharmaceutical ingredient was subjected to hydrolysis (acid, basic and neutral) and oxidative stress conditions. No interference of degradation products and tablet excipients were observed. This method showed to be rapid, simple, precise, accurate and economical for determination of nevirapine in pharmaceuticals and it is suitable for routine quality control analysis since CE offers benefits in terms of quicker method development and significantly reduced operating costs.
Resumo:
The aim of this study was to validate the intake of carotenoids, fruits and vegetables estimated by the Food Frequency Questionnaire for Adolescents (FFQA) using the method of triads. Blood samples were collected from 80 elementary school adolescents to assess serum levels of β-carotene. Partial correlation coefficients (r) were calculated between an estimated intake of carotenoids, fruits and vegetables and the serum levels of β-carotene. Validity coefficients were calculated using the method of triads. With the exception of carotenoids, partial r from the food frequency questionnaire (FFQ) were greater than those of the 24-hour recall (24hR). The fruit/vegetable group showed the highest partial r for the FFQ (r = 0.235) and the 24hR (r = 0.137). The highest validity coefficient was obtained for the vegetable group, as assessed by the FFQ (r = 0.873). On average, the validity coefficient values for the FFQ were greater than those obtained for the 24hR or the β-carotene serum levels. The FFQA is an accurate tool for estimating the intake of carotenoids, fruits and vegetables in this population group.
Resumo:
This study aimed to describe the behavior of oviposition traps for Aedes aegypti over time, to compare it with the larval survey and to investigate the association with climatic variables. It was conducted in São José do Rio Preto city, São Paulo. Daily climatic data and fortnightly measurements for oviposition traps and larval infestation were collected from October 2003 to September 2004. Three different periods were identified in the behavior of oviposition traps' positivity and mean number of eggs: increase, plateau and decrease in values. These measurements followed the variation of climatic data from the first and third periods. High correlation was obtained between the positivity and the mean number of eggs. The oviposition traps showed higher capacity to detect the vector than did larval survey. It was observed that the first (October to December) and third (May to September) periods were considered to be the most suitable to use oviposition traps than larval surveys.
Resumo:
This study investigates the use of wild animal hair of C. brachyurus, C. thous and L. pardalis as biomonitors of trace metal at Parque Nacional das Emas, Brazil. Results reveal a strong correlation between Cd and Pb as well as Cu and Zn, which suggests a single source of emission. Most metals showed a lower or equal concentration than those obtained in previous studies. The research shows that monitoring may be performed only with Zn, Pb, Cd, and Cr because of statistical similarity and of a non-natural occurrence of large amounts of the material under analysis.
Resumo:
A combination of trajectory sensitivity method and master-slave synchronization was proposed to parameter estimation of nonlinear systems. It was shown that master-slave coupling increases the robustness of the trajectory sensitivity algorithm with respect to the initial guess of parameters. Since synchronization is not a guarantee that the estimation process converges to the correct parameters, a conditional test that guarantees that the new combined methodology estimates the true values of parameters was proposed. This conditional test was successfully applied to Lorenz's and Chua's systems, and the proposed parameter estimation algorithm has shown to be very robust with respect to parameter initial guesses and measurement noise for these examples. Copyright (C) 2009 Elmer P. T. Cari et al.
Resumo:
This work deals with an improved plane frame formulation whose exact dynamic stiffness matrix (DSM) presents, uniquely, null determinant for the natural frequencies. In comparison with the classical DSM, the formulation herein presented has some major advantages: local mode shapes are preserved in the formulation so that, for any positive frequency, the DSM will never be ill-conditioned; in the absence of poles, it is possible to employ the secant method in order to have a more computationally efficient eigenvalue extraction procedure. Applying the procedure to the more general case of Timoshenko beams, we introduce a new technique, named ""power deflation"", that makes the secant method suitable for the transcendental nonlinear eigenvalue problems based on the improved DSM. In order to avoid overflow occurrences that can hinder the secant method iterations, limiting frequencies are formulated, with scaling also applied to the eigenvalue problem. Comparisons with results available in the literature demonstrate the strength of the proposed method. Computational efficiency is compared with solutions obtained both by FEM and by the Wittrick-Williams algorithm.