20 resultados para Air exchange rate
Resumo:
The aim of this study was to evaluate how the summer and winter conditions affect the photosynthesis and water relations of well-watered orange trees, considering the diurnal changes in leaf gas exchange, chlorophyll (Chl) fluorescence, and leaf water potential (I) of potted-plants growing in a subtropical climate. The diurnal pattern of photosynthesis in young citrus trees was not significantly affected by the environmental changes when compared the summer and winter seasons. However, citrus plants showed higher photosynthetic performance in summer, when plants fixed 2.9 times more CO(2) during the diurnal period than in the winter season. Curiously, the winter conditions were more favorable to photosynthesis of citrus plants, when considering the air temperature (< 29 A degrees C), leaf-to-air vapor pressure difference (< 2.4 kPa) and photon flux density (maximum values near light saturation) during the diurnal period. Therefore, low night temperature was the main environmental element changing the photosynthetic performance and water relations of well-watered plants during winter. Lower whole-plant hydraulic conductance, lower shoot hydration and lower stomatal conductance were noticed during winter when compared to the summer season. In winter, higher ratio between the apparent electron transport rate and leaf CO(2) assimilation was verified in afternoon, indicating reduction in electron use efficiency by photosynthesis. The high radiation loading in the summer season did not impair the citrus photochemistry, being photoprotective mechanisms active. Such mechanisms were related to increases in the heat dissipation of excessive light energy at the PSII level and to other metabolic processes consuming electrons, which impede the citrus photoinhibition under high light conditions.
Resumo:
This study tests the hypothesis that potted sweet orange plants show a significant variation in photosynthesis over seasonal and diurnal cycles. even in well-hydrated conditions. This hypothesis was tested by measuring diurnal variations in leaf gas exchange, chlorophyll fluorescence, leaf water potential, and the responses of CO(2) assimilation to increasing air CO(2) concentrations in 1-year-old `Valencia` sweet orange scions grafted onto `Cleopatra` mandarin rootstocks during the winter and summer seasons in a subtropical climate. In addition, diurnal leaf gas exchange was evaluated under controlled conditions, with constant environmental conditions during both winter and summer. In relation to our hypothesis, a greater rate of photosynthesis is found during the summer compared to the winter. Reduced photosynthesis during winter was induced by cool night conditions, as the diurnal fluctuation of environmental conditions was not limiting. Low air and soil temperatures caused decreases in the stomatal conductance and in the rates of the biochemical reactions underlying photosynthesis (ribulose-1,5-bisphosphate (RuBP) carboxylation and RuBP regeneration) during the winter compared to the values obtained for those markers in the Summer. Citrus photosynthesis during the summer was riot impaired by biochemical or photochemical reactions. as CO(2) assimilation was only limited by stomatal conductance due to high leaf-to-air vapor pressure difference (VPD) during the afternoon. During the winter, the reduction in photosynthesis during the afternoon Was Caused by decreases in RuBP regeneration and stomatal conductance, which are both precipitated by low night temperature. (c) 2009 Elsevier B.V. All rights reserved.
Resumo:
Background: Urban air pollutants are associated with cardiovascular events. Traffic controllers are at high risk for pollution exposure during outdoor work shifts. Objective: The purpose of this study was to evaluate the relationship between air pollution and systemic blood pressure in traffic controllers during their work shifts. Methods: This cross-sectional study enrolled 19 male traffic controllers from Santo Andre city (Sao Paulo, Brazil) who were 30-60 years old and exposed to ambient air during outdoor work shifts. Systolic and diastolic blood pressure readings were measured every 15 min by an Ambulatory Arterial Blood Pressure Monitoring device. Hourly measurements (lags of 0-5 h) and the moving averages (2-5 h) of particulate matter (PM(10)), ozone (O(3)) ambient concentrations and the acquired daily minimum temperature and humidity means from the Sao Paulo State Environmental Agency were correlated with both systolic and diastolic blood pressures. Statistical methods included descriptive analysis and linear mixed effect models adjusted for temperature, humidity, work periods and time of day. Results: Interquartile increases of PM(10) (33 mu g/m(3)) and O(3) (49 mu g/m(3)) levels were associated with increases in all arterial pressure parameters, ranging from 1.06 to 2.53 mmHg. PM(10) concentration was associated with early effects (lag 0), mainly on systolic blood pressure. However, O(3) was weakly associated most consistently with diastolic blood pressure and with late cumulative effects. Conclusions: Santo Andre traffic controllers presented higher blood pressure readings while working their outdoor shifts during periods of exposure to ambient pollutant fluctuations. However, PM(10) and O(3) induced cardiovascular effects demonstrated different time courses and end-point behaviors and probably acted through different mechanisms. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
in humans, adverse pregnancy outcomes (low birth weight, prematurity, and intrauterine growth retardation) are associated with exposure to urban air pollution. Experimental data have also shown that such exposure elicits adverse reproductive outcomes. We hypothesized that the effects of urban air pollution on pregnancy outcomes could be related to changes in functional morphology of the placenta. To test this, future dams were exposed during pregestational and gestational periods to filtered or nonfiltered air in exposure chambers. Placentas were collected from near-term pregnancies and prepared for microscopical examination. Fields of view on vertical uniform random tissue slices were analyzed using stereological methods. Volumes of placental compartments were estimated, and the labyrinth was analyzed further in terms of its maternal vascular spaces, fetal capillaries, trophoblast, and exchange surface areas. From these primary data, secondary quantities were derived: vessel calibers (expressed as diameters), trophoblast thickness (arithmetic mean), and total and mass-specific morphometric diffusive conductances for oxygen of the intervascular barrier. Two-way analysis of variance showed that both periods of exposure led to significantly smaller fetal weights. Pregestational exposure to nonfiltered air led to significant increases in fetal capillary surface area and in total and mass-specific conductances. However, the calibers of maternal blood spaces were reduced. Gestational exposure to nonfiltered air was associated with reduced volumes, calibers, and surface areas of maternal blood spaces and with greater fetal capillary surfaces and diffusive conductances. The findings indicate that urban air pollution affects placental functional morphology. Fetal weights are compromised despite attempts to improve diffusive transport across the placenta.
Resumo:
Objective: Uncertainties about the numerous degrees of freedom in ventilator settings leave many unanswered questions about the biophysical determinants of lung injury. We investigated whether mechanical ventilation with high air flow could yield lung mechanical stress even in normal animals. Design. Prospective, randomized, controlled experimental study. Setting: University research laboratory. Subjects. Thirty normal male Wistar rats (180-230 g). Interventions: Rats were ventilated for 2 hrs with tidal volume of 10 mL/kg and either with normal inspiratory air flow (V`) of 10 mL/s (F10) or high V` of 30 mL/s (F30). In the control group, animals did not undergo mechanical ventilation. Because high flow led to elevated respiratory rate (200 breaths/min) and airway peak inspiratory pressure (PIP,aw = 17 cm H2O), two additional groups were established to rule out the potential contribution of these variables: a) normal respiratory rate = 100 breaths/min and V` = 30 mL/sec; and b) PIP,aw = 17 cm H2O and V` 10 mL/sec. Measurements and Main Results: Lung mechanics and histology (light and electron microscopy), arterial blood gas analysis, and type III procollagen messenger RNA expression in lung tissue were analyzed. Ultrastructural microscopy was similar in control and F10 groups. High air flow led to increased lung plateau and peak pressures, hypoxemia, alveolar hyperinflation and collapse, pulmonary neutrophilic infiltration, and augmented type III procollagen messenger RNA expression compared with control rats. The reduction of respiratory rate did not modify the morphofunctional behavior observed in the presence of increased air flow. Even though the increase in peak pressure yielded mechanical and histologic changes, type III procollagen messenger RNA expression remained unaltered. Conclusions: Ventilation with high inspiratory air flow may lead to high tensile and shear stresses resulting in lung functional and morphologic compromise and elevation of type III procollagen messenger RNA expression.