165 resultados para ASSISTED THORACIC-SURGERY
Resumo:
A 44-year-old man presented with progressive dyspnea and a previous pneumothorax. Chest CT scan showed a mediastinal shift due to giant bullae containing soft tissue and fatty components in the left lower lung Lobe, and a right upper lung lobe partially collapsed. The pulmonary function tests revealed forced vital capacity (FVC) 53% (of the predicted) and forced vital capacity in 1 s (FEV1) 52%. Then, resection of the lower lobe was performed with intention to prevent other pneumothoraxes and to revert the upper lobe collapse. The pathological examination showed a placental. transmogrification of the lung (PTL). One month after the surgery, the patient was asymptomatic, the pulmonary function tests normalized and the upper lobe was well expanded. In conclusion, we described the first CT finding of soft tissue and fatty components within the PTL-related bullae, and the PTL should be considered in the differential diagnosis of pulmonary lesions with soft-fatty and air components. (c) 2007 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Resumo:
An asymptomatic 48-year-old woman presented to our hospital with a tumor of the rib incidentally diagnosed on a chest roentgenogram. The patient was investigated and underwent tumor resection of the chest wall. The pathologic study revealed that it was cavernous hemangioma. This tumor of the bone is a distinctly uncommon benign vascular tumor, generally occurring in the spine or skull. Hemangiomas involving the rib are even more rare, with only 22 cases described in the literature. However, we suggest that this tumor of the rib should be considered in the differential diagnosis, principally in asymptomatic patients. (Ann Thorac Surg 2011;91:595-6) (C) 2011 by The Society of Thoracic Surgeons
Resumo:
Objectives: We sought to compare long-term outcomes after coronary bypass surgery with and without an internal thoracic artery graft. Methods: We analyzed clinical outcomes over a median follow-up of 6.7 years among 3,087 patients who received coronary bypass surgery as participants in one of 8 clinical trials comparing surgical intervention with angioplasty. We used 2 statistical methods (covariate adjustment and propensity score matching) to adjust for the nonrandomized selection of internal thoracic artery grafts. Results: Internal thoracic artery grafting was associated with lower mortality, with hazard ratios of 0.77 (confidence interval, 0.62-0.97; P = .02) for covariate adjustment and 0.77 (confidence interval, 0.57-1.05; P = .10) for propensity score matching. The composite end point of death or myocardial infarction was reduced to a similar extent, with hazard ratios of 0.83 (confidence interval, 0.69-1.00; P = .05) for covariate adjustment to 0.78 (confidence interval, 0.61-1.00; P = .05) for propensity score matching. There was a trend toward less angina at 1 year, with odds ratios of 0.81 (confidence interval, 0.61-1.09; P = .16) in the covariate-adjusted model and 0.81 (confidence interval, 0.55-1.19; P = .28) in the propensity score-adjusted model. Conclusions: Use of an internal thoracic artery graft during coronary bypass surgery seems to improve long-term clinical outcomes. (J Thorac Cardiovasc Surg 2011; 142: 829-35)
Resumo:
Purpose: The objective of this study was to evaluate the postoperative quality of life (QOL) experienced among a group of 1167 patients who underwent video-assisted thoracoscopic sympathectomy (VATS) to treat primary hyperhidrosis, as compared with the presurgical QOL. Methods: Between February 2002 and June 2007, 1167 patients who had undergone VATS were surveyed. The majority had presented with palmar hyperhidrosis (794 patients; 68%), while 340 (29%) had presented with axillary hyperhidrosis. Based on data obtained from the QOL protocol applied to all of the patients preoperatively, the patients were divided into two groups according to the level of their QOL: group 1 consisted of 312 patients (27%) with poor QOL and group 2 of 855 patients (73%) with very poor QOL. The same protocol was applied postoperatively, and five different levels of satisfaction were obtained. The same parameters were evaluated for both the palmar and the axillary hyperhidrosis subgroups. Results: The patients with very poor QOL had much better results in terms of improvement in QOL than did those with poor QOL ( P < .05). The same result was observed for both the palmar and. axillary hyperhidrosis subgroups (P < .05). Conclusion: The worse the preoperative QOL among patients undergoing sympathectomy to treat primary hyperhidrosis is, the better the postoperative improvement in QOL will be. (J Vase Surg 2010;51:1190-4.)
Resumo:
Purpose: We compared the results from a video-assisted thoracoscopic sympathectomy (VTS) at the T4 denervation level with those from a VTS at the T3 level for the treatment of palmar hyperhydrosis (PH). Methods: Seventy patients with PH were prospectively followed for VTS at the T3 or T4 denervation levels for 6 months. The end points of this study were: absence of PH, compensatory hyperhydrosis (CH), and quality-of-life assessment. Results: Sixty-seven patients reported a complete resolution of PH after surgery. One failure occurred in the T3 group and 2 in the T4 group. When anhydrosis was obtained, we noticed totally dry hands in 26 patients in the T3 group and 6 patients in the T4 group. The other 27 patients in the T4 group and 8 in the T3 group maintained a small level of sweating and were also considered to be therapeutic successes. At 6 months, 25 patients in the T4 group had some degree of CH (71.42%) and all patients in the T3 group (100%), though the T4 group had a lower degree of severity of CH at the 6-month follow-up (P < 0.05). After the operation, quality of life was improved similarly in both groups. Conclusions: VTS at either the T3 or T4 level provides an effective treatment for PH. VTS at the T4 level is associated with a less severe form of CH. Despite the occurrence of CH, patients' quality of life is significantly improved following VTS at the T3 or T4 levels. For this reason, the T4 resection can now be used as a treatment for PH.
Resumo:
Purpose: To analyze in an experimental animal model the effect of 4 different levels of stents-graft oversizing on non-atherosclerotic aortas such as those found in young individuals who undergo stent-graft repair for traumatic aortic injuries. Methods: The diameter of the porcine thoracic aorta is similar to the aorta of young adults (18-20 mm), so 25 pigs were randomized into 5 groups: 1 control (without stent-graft) and 4 oversizing groups (A: 10%-19%, B: 20%-29%, C: 30%-39%, and D: >40%). Two types of biomechanical tests were performed on all aortas 4 weeks after endoprosthesis deployment. Results: The results of the detachment test, which analyzed the strength necessary to remove the stent-graft from the aorta, were similar in the 4 groups (A: 42 N, B: 41 N, C: 46 N, and D: 46 N). However, 2 aortas ruptured during the tests (groups C and D). The second test was performed in 3 aortic segments. Maximum shear strength, maximum stress, and maximum tension supported by the aortic wall had a negative and linear correlation with oversizing. There were significant differences in all 4 groups when compared with the control group. Strain, which reflects the elastic properties of the aortic wall, was very similar in all 4 groups, but a great difference was found when compared with the control group (p<0.0001). Conclusion: The study showed an important subacute change in the biomechanical properties of the aortic wall after implantation of an oversized endoprosthesis. This weakness of the aortic wall was confirmed by 2 ruptures during the detachment test. These results partially explain the interaction of stent-grafts with non-atherosclerotic thoracic aortas and may serve as a basis for further studies and the development of specific material to be used in vascular trauma and young patients. J Endovasc Ther. 2011; 18: 576-584
Resumo:
Objective. The objective of this study was to evaluate, using computed tomography, correlations between Hyrax appliance opening and post-SARPE skeletal changes. Study design. Fifteen patients underwent SARPE according to a specific protocol and were followed. Linear and angular measurements of the anterior, intermediate, and posterior portions of the maxilla were evaluated. The correlation between maxillary expansion and appliance opening was investigated. Results. Significant overall expansion was observed. In the anterior and intermediate portions of the maxilla, the increase in maxillary width was greater than that observed in the posterior portion. The degree of appliance opening was significantly greater than that of the skeletal expansion. Also, no linear correlation between appliance opening and regional maxillary expansion was established. Conclusion. The transverse expansion of the maxilla was less than uniform. The lack of linear correlation between appliance opening and skeletal expansion is attributable to multiple factors, including those related to the device, the surgical technique, and the craniofacial deformity itself. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 812-819)
Resumo:
Background/Aims: Safety of laparoscopic colectomy education methods remains unknown. This study aimed at comparing the outcomes of patients undergoing preceptored laparoscopic colectomy with patients operated on by the same preceptor. Methodology: A prospective analysis of 30 preceptored operations performed by nine surgeons (PD group) between 2006 and 2008 was conducted. Data of 30 operations matched for diagnosis and surgery type conducted by the same preceptor (P group) were evaluated. Results: Median age was 56.2 (26-80) and 55.2 (22-81) respectively in P and PD group (p=0.804). Eleven (36.7%) were male in P group, 16 (53.3%) in PD group (p=0.194). Preceptored operations were not significantly longer than operations performed by the preceptor (198 vs. 156 min) - p=0.072. Length of hospital stay did not differ [4 days (3-12) in P group, and 5 (3-15) in PD group, p=0.296]. Conversion occurred in 4 cases in PD and in 2 in P group (p=0.389). Morbidity was similar (23.3% in P and 26.7% in PD group). One patient from P and two from PD group needed re-operation. No deaths occurred. Conclusions: Laparoscopic colorectal surgery preceptorship programs in surgeon learner`s place are safe. Surgeons` introduction through basic and hands-on courses is required for skills acquisition needed to minimize adverse outcomes.
Resumo:
Introduction: Current advances in frame modeling and computer software allow stereotactic procedures to be performed with great accuracy and minimal risk of neural tissue or vascular injury. Case Report: In this report we associate a previously described minimally invasive stereotactic technique with state-of-the-art 3D computer guidance technology to successfully treat a 55-year-old patient with an arachnoidal cyst obstructing the aqueduct of Sylvius. We provide 1 detailed technical information and discuss how this technique deals with previous limitations for stereotactic manipulation of the aqueductal region. We further discuss current advances in neuroendoscopy for treating obstructive hydrocephalus and make comparisons with our proposed technique. Conclusion: We advocate that this technique is not only capable of treating this pathology but it also has the advantages to enable reestablishment of physiological CSF flow thus preventing future brainstem compression by cyst enlargement.
Resumo:
Background: Since its introduction, laparoscopic colorectal surgery has raised intense debate and controversies regarding its safety and effectiveness. Methods: This multicentric registry reports the experience of 28 Brazilian surgical teams specializing in laparoscopic colorectal surgery. Results: Between 1992 and 2007, 4744 patients (1994 men-42% and 2750 women-58%) were operated upon, with ages ranging from 13 to 94 years (average 57.5y). Benign diseases were diagnosed in 2356 patients (49.6%). Most diseases were located in 50.7% of the left and sigmoid colon, 28.2% in the rectum and anal canal. 8.0% in the right colon, and diffuse 7.0%. There were 181 (3.8%) intraoperative complications (from 0% to 14%). There were 261 (5.5%) reported conversions to laparotomy (from 0% to 16.5%), mainly during the early experience (n = 119 - 59.8%). Postoperative complications were registered in 683 (14.5%) patients (from 5.0% to 50%). Mortality occurred in 43 patients (0.8%). Surgeons who performed less than 50 cases reported similar rates of intraoperative (4.2% vs. 3.8%,- P = 0.7), postoperative complications (20.8% vs. 14.3%; P = 0.07), and mortality (1.0% vs. 0.9%; P = 0.5) but the conversion rate was higher (10.4% vs. 5.4%; P = 0.04). Two thousand three hundred and eighty-nine (50.4%) malignant tumors were operated upon, and histologic classification showed 2347 (98%) adenocarcinomas, 30 (0.6%) spinocelular carcinomas, and 12 (0.2%) other histologic types. Tumor recurrence rate was 16.3% among patients followed more than I year. After an average follow-Lip of 52 months, 19 (0.8%) parietal recurrences were reported, 18 of which were in port sites and I in a patient with disseminated disease. There was no incisional recurrence in the ports used to withdraw the pathologic specimen. Compared with other registries, there was a 75% increase in the number of groups pet-forming laparoscopic colorectal surgery and a decrease in conversions (from 10.5%. to 5.5%) and mortality (from 1.5% to 0.9%) rates. Conclusions: (1) The number of patients operated upon increased expressively during the last years; (2) operative indications for benign and malignant diseases were similar, and diverticular disease of the colon comprised 40% of the benign ones; (3) conversion and mortality rates decreased over time; (4) Surgeon`s experience did not influence the complication rates, but was associated with a lower conversion; and (5) oncologic outcome expressed by recurrence rates showed results similar to those reported in conventional surgery.
Resumo:
Background: Widespread use of prostate-specific antigen screening has resulted in younger and healthier men being diagnosed with prostate cancer. Their demands and expectations of surgical intervention are much higher and cannot be adequately addressed with the classic trifecta outcome measures. Objective: A new and more comprehensive method for reporting outcomes after radical prostatectomy, the pentafecta, is proposed. Design, setting, and participants: From January 2008 through September 2009, details of 1111 consecutive patients who underwent robot-assisted radical prostatectomy performed by a single surgeon were retrospectively analyzed. Of 626 potent men, 332 who underwent bilateral nerve sparing and who had 1 yr of follow-up were included in the study group. Measurements: In addition to the traditional trifecta outcomes, two perioperative variables were included in the pentafecta: no postoperative complications and negative surgical margins. Patients who attained the trifecta and concurrently the two additional outcomes were considered as having achieved the pentafecta. A logistic regression model was created to evaluate independent factors for achieving the pentafecta. Results and limitations: Continence, potency, biochemical recurrence-free survival, and trifecta rates at 12 mo were 96.4%, 89.8%, 96.4%, and 83.1%, respectively. With regard to the perioperative outcomes, 93.4% had no postoperative complication and 90.7% had negative surgical margins. The pentafecta rate at 12 mo was 70.8%. On multivariable analysis, patient age (p = 0.001) was confirmed as the only factor independently associated with the pentafecta. Conclusions: A more comprehensive approach for reporting prostate surgery outcomes, the pentafecta, is being proposed. We believe that pentafecta outcomes more accurately represent patients` expectations after minimally invasive surgery for prostate cancer. This approach may be beneficial and may be used when counseling patients with clinically localized disease. (C) 2011 European Association of Urology. Published by Elsevier B. V. All rights reserved.
Resumo:
In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.
Resumo:
Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.