Aim: Our aim was to test: the hypothesis that co-exposure to lead and fluoride alter the severity of enamel fluorosis. Materials and methods: Wistar rats were allocated in four groups: control, and 3 groups that received water containing 100 ppm of fluoride (F), 30 ppm of lead (Pb), or 100 ppm of F and 30 ppm of Pb (F + Pb) from the beginning of gestation. Enamel analysis and F and Pb determinations in enamel, dentine, and bone were performed in 81-day-old animals. Fluorosis was quantified using a new fluorosis index based on the identification of incisor enamel defects (white bands and white islets, representing hypomineralization, and cavities) weighted according to their severity and quantity. Hypomineralization was validated histopathologically by polarizing microscopy and microradiography. Scores were given by two blinded calibrated examiners (intra and interexaminer kappa values were 0.8 and 0.86, respectively). Results: The control and the Pb groups presented normal enamel. The F + Pb group presented more severe enamel defects compared with the F group (P < 0.0001). Conclusions: This study shows that lead exacerbates dental fluorosis in rodents, suggesting that co-exposure to lead may affect the degree of fluorosis. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Nitric oxide (NO) is a major regulator of cardiovascular homeostasis and has anti-atherogenic properties. Reduced NO formation is associated with endothelial dysfunction and with cardiovascular risk factors. Although NO downregulates the expression and activity of the pro-atherogenic enzyme matrix metalloproteinase-9 (MMP-9), no previous clinical study has examined whether endogenous NO formation is inversely associated with the circulating levels of pro-MMP-9, which are associated with cardiovascular events. We examined this hypothesis in 175 healthy male subjects who were non-smokers. Methods: To assess NO bioavailability, the plasma concentrations of nitrite, nitrate, and cGMP were determined using an ozone-based chemiluminescence assay and an enzyme immunoassay. Pro-MMP-9 and pro-MMP-2 levels were measured in plasma samples by gelatin zymography. Results: We found significant negative correlations between pro-MMP-9 levels and plasma nitrite (P=0.035, rs=-0.159), nitrate (P=0.040, rs=-0.158), and cGMP (P=0.011, rs=-0.189) concentrations. However, no significant correlations were found between pro-MMP-2 levels and the plasma concentrations of markers of NO bioavailability (all P>0.05). Conclusions: There is an inverse relationship between markers of NO formation and plasma MMP-9 levels. This finding may shed some light on the possible mechanisms involved in the increased cardiovascular risk of apparently healthy subjects with low NO bioavailability or high circulating levels of pro-MMP-9. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. This article discusses the relationship between apical limit of root canal filling and success on endodontic treatment of a mandibular molar. Study design. A mandibular right first molar with vital pulp was endodontically treated, and 3 years later periapical lesions on mesial and distal roots were detected. The canals were retreated and obturated to the same levels as in the previous treatment. Results. An 8-year radiographic follow-up showed repair of the periapical lesions on both roots. Conclusions. Results suggest that the apical limit of obturation seems to have no influence in the repair of periapical tissues in mandibular molars. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: e48-e50)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The double system of support, in which the distal-extension removable partial denture adapts, causes inadequate stress around abutment teeth, increasing the possibility of unequal bone resorption. Several ways to reduce or more adequately distribute the stress between abutment teeth and residual ridges have been reported; however, there are no definitive answers to the problem. The purpose of this study was to analyze, by means of photoelasticity, the most favorable stress distribution using three retainers: T bar, rest, proximal plate, I bar (RPI), and circumferential with mesialized rest. Materials and Methods: Three photoelastic models were made simulating a Kennedy Class II inferior arch. Fifteen dentures with long saddles, five of each design, were adjusted to the photoelastic patterns and submitted first to uniformly distributed load, and then to a load localized on the last artificial tooth. The saddles were then shortened and the tests repeated. The quantitative and qualitative analyses of stress intensity were done manually and by photography, respectively. For intragroup analyses the Wilcoxon test for paired samples was used, while for intergroup analyses Friedman and Wilcoxon tests were used to better identify the differences (p < 0.05). Results: The RPI retainer, followed by the T bar, demonstrated the best distribution of load between teeth and residual ridge. The circumferential retainer caused greater concentration of stress between dental apexes. Stress distribution was influenced by the type of retainer, the length of the saddle, and the manner of load application. Conclusions: The long saddles and the uniformly distributed loads demonstrated better distribution of stress on support structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This triple-blind, 2 x 2 crossover in situ study, was undertaken to verify whether the wear resistance of enamel and root dentine would be affected by bleaching with a 10% carbamide peroxide agent and a placebo agent. Methods: Thirty slabs of each. substrate (2 mm x 3 mm x 2 mm) were selected for each phase, after flattening and polishing procedures and microhardness test. After a 7-day lead-in period, one specimen of each substrate was randomly bonded on the facial surface of each one of 30 subject`s upper second premolars. The volunteers received instructions on how to perform toothbrushing and application of gel in the tray. Fifteen volunteers bleached their maxillary arch with a 10% carbamide peroxide bleaching agent for a 2-week period, while the remainders used a placebo agent. After a 1-week washout period, a new set of enamel and root dentine slabs were bonded to the premolars and volunteers were crossed over to the alternate agent for 14 days. The resistance of enamel and root dentine to wear following bleaching, toothbrushing and intraoral exposure was measured with a profilometer, using reference areas. Results: For enamel, ANOVA did not demonstrate significant difference between wear provided by placebo and bleaching agent (p = 0.3713), but higher wear depth was observed for bleached root dentine (p = 0.0346). Conclusions: While overnight bleaching caused no alteration in wear resistance of enamel, root dentine showed increased tissue loss. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the effect of low and highly concentrated bleaching agents on microhardness and surface roughness of bovine enamel and root dentin. According to a randomized complete block design, 100 specimens of each substrate were assigned into five groups to be treated with bleaching agents containing carbamide peroxide (CP) at 10% (CP10); hydrogen peroxide (HP) at 7.5% (HP7.5) or 38% (HP38), or the combination of 18% of HP and 22% of CP (HP18/CP22), for 3 weeks. The control group was left untreated. Specimens were immersed in artificial saliva between bleaching treatments. Knoop surface microhardness (SMH) and average surface roughness (Ra) were measured at baseline and post-bleaching conditions. For enamel, there were differences between bleaching treatments for both SMH and Ra measurements (p = 0.4009 and p = 0.7650, respectively). SMH significantly increased (p < 0.0001), whereas Ra decreased (p = 0.0207) from baseline to post-bleaching condition. For root dentin, the group treated with CP10 exhibited the significantly highest SMH value differing from those groups bleached with HP18/CP22, HP7.5, which did not differ from each other. Application of HP38 resulted in intermediate SMH values. No significant differences were found for Ra (p = 0.5975). Comparing the baseline and post-bleaching conditions, a decrease was observed in SMH (p < 0.0001) and an increase in Ra (p = 0.0063). Bleaching agents with varying concentrations of CP and/or HP are capable of causing mineral loss in root dentin. Enamel does not perform in such bleaching agent-dependent fashion when one considers either hardness or surface roughness evaluations. Bleaching did not alter the enamel microhardness and surface roughness, but in root dentin, microhardness seems to be dependent on the bleaching agent used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cigarette smoke is a significant source of cadmium, lead, and toxic elements, which are absorbed into the human organism. In this context, the aim of this study was to investigate in vitro the presence of toxic elements, cadmium, and lead deriving from cigarette smoke in the resin composite, dentine, and dental enamel. Eight cylindrical specimens were fabricated from resin composite, bovine enamel, and root dentin fragments that were wet ground and polished with abrasive paper to obtain sections with 6-mm diameter and 2-mm thickness. All specimens were exposed to the smoke of 10 cigarettes/day during 8 days. After the simulation of the cigarette smoke, the specimens were examined with scanning electron microscopy (SEM) and the energy-dispersive X-ray analysis. In the photomicrographic analysis in SEM, no morphological alterations were found; however, the microanalysis identified the presence of cadmium, arsenic, and lead in the different specimens. These findings suggest that the deposition of these elements derived from cigarette smoke could be favored by dental structures and resin composite. Microsc. Res. Tech. 74:287-291, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Long-term success of the implant restorations is based upon the biology and vasculature of the bone surrounding the implants, especially for the bone between two implants. Purpose The aim of this study was to evaluate how loaded implants placed 2 or 3 mm apart influence bone vessel organization. Material and methods Six mongrel dogs were used for the study. The four mandibular premolars were extracted and 3 months later, four 4.5 x 10 mm implants were placed on each side of the mandible. The implants were placed so that two adjacent implants were 2 mm (group 1) or 3 mm (group 2) distant from each other. After 12 weeks, the implants were loaded with provisional prostheses, then metallic crowns were placed 4 weeks later. Both temporary and metallic restorations were made so that the distance between the contact point and the bone crest was 5 mm. The animals were sacrificed after 8 weeks. The hemi-mandibles were removed and prepared for analysis. The interimplant bone vasculature of the two groups was studied using scanning electron microscopic images fractal analysis. The fractal dimension (D(f)) was calculated using the box-counting method. Results The values of the D(f) for the blood vessels were significantly higher (P <.05) in the specimens of the group 2 (1.969 +/- 0.169) than the group 1 (1.556 +/- 0.246). Conclusion The presence of more blood vessels in the group 2 is another indication that 3 mm is a preferable distance for contiguous implants than the 2 mm distance. To cite this article:Traini T, Novaes AB, Piattelli A, Papalexiou V, Muglia VA. The relationship between interimplant distances and vascularization of the interimplant bone.Clin. Oral Impl. Res. 21, 2010; 822-829.doi: 10.1111/j.1600-0501.2010.01926.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.