189 resultados para eletro-optical measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate and compare rates of change in neuro-retinal rim area (RA) and retinal nerve fiber layer thickness (RNFLT) measurements in glaucoma patients, those with suspected glaucoma, and normal subjects observed over time. METHODS. In this observational cohort study, patients recruited from two longitudinal studies (Diagnostic Innovations in Glaucoma Study-DIGS and African Descent and Evaluation Study-ADAGES) were observed with standard achromatic perimetry (SAP), optic disc stereophotographs, confocal scanning laser ophthalmoscopy (HRT-3; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx-VCC; Carl Zeiss Meditec, Inc., Dublin, CA). Glaucoma progression was determined by the Guided Progression Analysis software for standard automated perimetry [SAP] and by masked assessment of serial optic disc stereophotographs by expert graders. Random-coefficients models were used to evaluate rates of change in average RNFLT and global RA measurements and their relationship with glaucoma progression. RESULTS. At baseline, 194 (31%) eyes were glaucomatous, 347 (55%) had suspected glaucoma, and 88 (14%) were normal. Forty-six (9%) eyes showed progression by SAP and/or stereophotographs, during an average follow-up of 3.3 (+/-0.7) years. The average rate of decline for RNFLT measurements was significantly higher in the progressing group than in the non-progressing group (-0.65 vs. -0.11 mu m/y, respectively; P < 0.001), whereas RA decline was not significantly different between these groups (-0.0058 vs. -0.0073 mm(2)/y, respectively; P = 0.727). The areas under the receiver operating characteristic (ROC) curves used to discriminate progressing versus nonprogressing eyes were 0.811 and 0.507 for the rates of change in the RNFLT and RA, respectively (P < 0.001). CONCLUSIONS. The ability to discriminate eyes with progressing glaucoma by SAP and/or stereophotographs from stable eyes was significantly greater for RNFLT than for RA measurements. (Invest Ophthalmol Vis Sci. 2010;51:3531-3539) DOI: 10.1167/iovs.09-4350

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To determine if knee alignment measures differ between African Americans and Caucasians without radiographic knee osteoarthritis (rOA). Methods. A single knee was randomly selected from 175 participants in the Johnston County Osteoarthritis Project without rOA in either knee. Anatomic axis, condylar, tibia] plateau, and condylar plateau angles were measured by I radiologist; means were compared and adjusted for age and body mass index (BMI). Results. There were no significant differences in knee alignment measurements between Caucasians and African Americans among men or women. Conclusion. Observed differences in knee rOA occurrence between African Americans and Caucasians are not explained by differences in static knee alignment. (First Release July 15 2009; J Rheumatol 2009;36:1987-90; doi: 10.3899/jrheum.081294)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to study the correlation between the intraocular pressure peaks and fluctuation detected during the water drinking test and the same parameters observed during long-term follow up. This prospective cohort study enrolled 22 eyes of 22 newly diagnosed primary open angle glaucoma patients. After an initial complete ophthalmological examination, patients were started on antiglaucoma medication and returned 4 weeks later to perform the water drinking test. Thereafter, patients were evaluated at least eight times within a period of 6-12 months. The intraocular pressure peaks and fluctuation detected during the water drinking stress test were compared with those observed during regular office visits. Spearman`s correlation coefficient and Bland-Altman Plots were used for statistical analysis. The mean age of participants was 54.3 +/- 8.2 years (+/- SD), 59% were women, and average mean deviation -10.2 +/- 4.5 dB. The mean follow-up period was 8.2 +/- 2.0 months. The average intraocular pressure peaks and fluctuation during the water drinking test were 20.0 +/- 2.9 mmHg and 40 +/- 10%, respectively, and 18.1 +/- 2.8 mmHg and 30 +/- 10% during follow up. Spearman`s correlation coefficients were significant and strong between the intraocular pressure peaks and fluctuation detected during the water drinking test and during the follow-up period (P < 0.001, rho = 0.76 and 0.82, respectively). There was good agreement between the variables. The intraocular pressure peaks and fluctuation detected during the water drinking test showed significant correlation and agreement with the pressures observed during follow-up visits. Stress tests could be used to estimate long-term intraocular pressure variation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To build nomograms of fetal thyroid circumference (FTC), fetal thyroid area (FTA), and fetal thyroid transverse diameter (FTTD) throughout gestational age (GA). Method. Between January 2006 and July 2006, FTC, FTA, and FTTD were measured once in 196 normal fetuses examined at a GA of 22-35 weeks. Inclusion criteria were a healthy mother with normal maternal thyrotropin level during pregnancy, a singleton pregnancy with normal fetal morphology on sonography, and GA confirmed via first-trimester sonographic examination. Results. Mean FTC, FTA, and FTTD ranged from 3.21 cm, 0.58 cm(2), and 1.19 cm at 22 weeks to 5.11 cm, 1.69 cm(2), and 1.89 cm at 35 weeks, respectively. Linear regression analysis yielded the following formulas for FTC, FTA, and FTTD according to GA: FTC (cm) = 0.146 X GA (weeks); FTA (cm(2)) = -1.289 + 0.085 X GA (weeks); FTTD (cm) = 0.054 X GA (weeks). The following logarithmic formulas were obtained for the expected fetal thyroid measurements according to estimated fetal weight (FW): FTC (cm) = -4.791 + 1.265 X logN FW; FTA (cm(2)) = -1.676 + 0.455 X logN FW; and FTTD (cm) = 0.399 + 0.001 X logN FW. Conclusion. We describe new nomograms of fetal thyroid measurements throughout gestation that may be useful in case of thyroid dysfunction. (C) 2008 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The mechanism underlying increased perception of food bolus passage in the absence of esophageal mechanical obstruction has not been completely elucidated. A correlation between the intensity of the symptom and the severity of esophageal dysfunction, either motility (manometry) or bolus transit (impedance) has not been clearly demonstrated. The aim of this study was to analyze the correlation between objective esophageal function assessment (with manometry and impedance) and perception of bolus passage in healthy volunteers (HV) with normal and pharmacologically-induced esophageal hypocontractility, and in patients with gastro-esophageal reflux disease (GERD) with and without ineffective esophageal motility (IEM). Methods Combined manometry-impedance was performed in 10 HV, 19 GERD patients without IEM and nine patients with IEM. Additionally, nine HV were studied after 50 mg sildenafil, which induced esophageal peristaltic failure. Perception of each 5 mL viscous swallow was evaluated using a 5-point scale. Manometry identified hypocontractility (contractions lower than 30 mmHg) and impedance identified incomplete bolus clearance. Key Results In HV and in GERD patients with and without IEM, there was no association between either manometry or impedance and perception on per swallow analysis (OR: 0.842 and OR: 2.017, respectively), as well as on per subject analysis (P = 0.44 and P = 0.16, respectively). Lack of correlation was also found in HV with esophageal hypocontractility induced by sildenafil. Conclusions & Inferences There is no agreement between objective measurements of esophageal function and subjective perception of bolus passage. These results suggest that increased bolus passage perception in patients without mechanical obstruction might be due to esophageal hypersensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study compared two heating methods currently used for antigen retrieval (AR) immunostaining: the microwave oven and the steam cooker. Myosin-V, a molecular motor involved in vesicle transport, was used as a neuronal marker in honeybee Apis mellifera brains fixed in formalin. Overall, the steam cooker showed the most satisfactory AR results. At 100 degrees C, tissue morphology was maintained and revealed epitope recovery, while evaporation of the AR solution was markedly reduced; this is important for stabilizing the sodium citrate molarity of the AR buffer and reducing background effects. Standardization of heat-mediated AR of formalin-fixed and paraffin-embedded tissue sections results in more reliable immunostaining of the honeybee brain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.