183 resultados para Non-cyclic recipient mares
Resumo:
Objective To evaluate the relationship between breastfeeding duration and the prevalence of non-nutritive Sucking habits in children with deciduous dentition. Method A cross-sectional survey was conducted on the mothers of 551 children aged 3 to 6 years, randomly selected from public pre-schools in Sao Paulo, Brazil. Mothers were asked to complete a questionnaire that included items regarding their children`s age, gender, race, method and duration of infant feeding, as well as pacifier use and/or digit-sucking habits. According to the answers pertinent to the method and duration of infant feeding, children were assigned to five groups: 1 - never breastfed, 2 - breastfed for a period shorter than 3 months of life, 3 - breastfed for 3 to 6 months, 4 - breastfed for 6 to 9 months, and 5 - breastfed for 9 months or longer. Data were submitted to the Fisher`s exact test with Bonferroni correction for multiple comparisons to analyse possible associations between breastfeeding duration period categories and non-nutritive sucking behaviours. Results Pacifier use frequency was high in groups 1, 2, 3 and 4 (85%, 87.6%, 78% and 70%, respectively), in comparison with that in group 5 (38.6%). The prevalence of non-nutritive sucking habits was significantly reduced in children who were breastfed for nine months or longer (p=0.000). There were no statistically significant differences in the frequencies of pacifier use and/or digit-sucking habits between genders, regardless of the breastfeeding duration period. Conclusion Children aged 3-6 years who were breastfed for nine months or longer had a lower prevalence of non-nutritive sucking habits.
Resumo:
Background: Nitric oxide (NO) is a major regulator of cardiovascular homeostasis and has anti-atherogenic properties. Reduced NO formation is associated with endothelial dysfunction and with cardiovascular risk factors. Although NO downregulates the expression and activity of the pro-atherogenic enzyme matrix metalloproteinase-9 (MMP-9), no previous clinical study has examined whether endogenous NO formation is inversely associated with the circulating levels of pro-MMP-9, which are associated with cardiovascular events. We examined this hypothesis in 175 healthy male subjects who were non-smokers. Methods: To assess NO bioavailability, the plasma concentrations of nitrite, nitrate, and cGMP were determined using an ozone-based chemiluminescence assay and an enzyme immunoassay. Pro-MMP-9 and pro-MMP-2 levels were measured in plasma samples by gelatin zymography. Results: We found significant negative correlations between pro-MMP-9 levels and plasma nitrite (P=0.035, rs=-0.159), nitrate (P=0.040, rs=-0.158), and cGMP (P=0.011, rs=-0.189) concentrations. However, no significant correlations were found between pro-MMP-2 levels and the plasma concentrations of markers of NO bioavailability (all P>0.05). Conclusions: There is an inverse relationship between markers of NO formation and plasma MMP-9 levels. This finding may shed some light on the possible mechanisms involved in the increased cardiovascular risk of apparently healthy subjects with low NO bioavailability or high circulating levels of pro-MMP-9. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.