172 resultados para amplified fragment length polymorphisms (AFLP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although antibodies to Bartonella henselae have been described in all neotropical felid species, DNA has been detected in only one species, Leopard us wiedii. The aim of this study was to determine whether DNA of Bartonella spp. could be detected in blood of other captive neotropical felids and evaluate risk factors and hematological findings associated with infection. Blood samples were collected from 57 small felids, including 1 Leopard us geoffroyi, 17 L wiedii, 22 Leopardus tigrinus, 14 Leopardus pardalis, and 3 Puma yagouaroundi; 10 blood samples from Panthera onca were retrieved from blood banks. Complete blood counts were performed on blood samples from small felids, while all samples were evaluated by PCR. DNA extraction was confirmed by amplification of the cat GAPDH gene. Bartonella spp. were assessed by amplifying a fragment of their 16S-23S rRNA intergenic spacer region; PCR products were purified and sequenced. For the small neotropical felids, risk factors [origin (wild-caught or zoo-born), gender, felid species, and flea exposure) were evaluated using exact multiple logistic regression. Hematological findings (anemia, polycythemia/hyperproteinemia, leukocytosis and leukopenia) were tested for association with infection using Fisher`s exact test. The 635 bp product amplified from 10 samples (10/67 = 14.92%) was identified as B. henselae by sequencing. Small neotropical felid males were more likely to be positive than females (95% CI = 0.00-0.451, p = 0.0028), however other analyzed variables were not considered risk factors (p > 0.05). Hematological abnormalities were not associated with infection (p > 0.05). This is the first report documenting B. henselae detection by PCR in several species of neotropical felids. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The immunossuppression caused by HIV infection makes the affected individuals more susceptible to some diseases including infections, neoplasms, or even the association between them. Kaposi sarcoma (KS) is the most common AIDS-related neoplasm, featured as an angioproliferative disorder. Its cause seems to be related to the human herpesvirus type 8 and it is usually associated with lower CD4+ T cell count. Oral involvement is frequent, presenting red to blue-purplish plaques, maculaes, and nodules. On the other hand, paracoccidioidomycosis (PCM) is a systemic mycosis, endemic in Latin America, caused by Paracoccidioides brasiliensis. This mycosis is not commonly related to human immunodeficiency virus (HIV) infection, although PCM can be present in immunosuppression cases. Oral lesions, as granulomatous ulcers, are often identified in seropositive patients with PCM. A rare case, in which a male HIV-positive patient presented simultaneously Kaposi sarcoma and PCM in the same fragment of oral mucosa biopsy, is described. To the best of our knowledge, this concomitant association had not been previously described. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Matrix metalloproteinase-9 (MMP-9) is involved in the degradation of the extracellular matrix during physiological and pathological processes. Two functional polymorphisms [C(-1562)T and microsatellite (CA)(13-25)] in the promoter region of the MMP-9 gene have been associated with several diseases. The aim of this study was to examine whether these MMP-9 polymorphisms and haplotypes are linked with plasma MMP-9 variations in healthy subjects. Methods: We studied 177 healthy male white volunteers (age range 20-55 years) who were non-smokers and not taking any medication. Genomic DNA was extracted from whole blood and genotypes for the C(-1562)T and the microsatellite (CA)(n) polymorphisms were determined. MMP-9 levels were measured in plasma samples by gelatin zymography. Results: The frequency of the alleles C and T for the C(-1562)T polymorphism were 90% and 10%, respectively. The frequency of the alleles with less than 21 CA repeats Q and with 21 repeats or higher (H) were 47% and 53%, respectively. We found no differences in plasma MMP-9 levels among the genotype groups or among different haplotypes (all p > 0.05). Conclusions: These findings suggest that functional polymorphisms in the promoter of the MMP-9 gene are not linked with significant plasma MMP-9 variations in healthy subjects.