223 resultados para Scanning reference electrode technique
Resumo:
Purpose: To evaluate the ability of the GDx Variable Corneal Compensation (VCC) Guided Progression Analysis (GPA) software for detecting glaucomatous progression. Design: Observational cohort study. Participants: The study included 453 eyes from 252 individuals followed for an average of 46 +/- 14 months as part of the Diagnostic Innovations in Glaucoma Study. At baseline, 29% of the eyes were classified as glaucomatous, 67% of the eyes were classified as suspects, and 5% of the eyes were classified as healthy. Methods: Images were obtained annually with the GDx VCC and analyzed for progression using the Fast Mode of the GDx GPA software. Progression using conventional methods was determined by the GPA software for standard automated achromatic perimetry (SAP) and by masked assessment of optic disc stereophotographs by expert graders. Main Outcome Measures: Sensitivity, specificity, and likelihood ratios (LRs) for detection of glaucoma progression using the GDx GPA were calculated with SAP and optic disc stereophotographs used as reference standards. Agreement among the different methods was reported using the AC(1) coefficient. Results: Thirty-four of the 431 glaucoma and glaucoma suspect eyes (8%) showed progression by SAP or optic disc stereophotographs. The GDx GPA detected 17 of these eyes for a sensitivity of 50%. Fourteen eyes showed progression only by the GDx GPA with a specificity of 96%. Positive and negative LRs were 12.5 and 0.5, respectively. None of the healthy eyes showed progression by the GDx GPA, with a specificity of 100% in this group. Inter-method agreement (AC1 coefficient and 95% confidence intervals) for non-progressing and progressing eyes was 0.96 (0.94-0.97) and 0.44 (0.28-0.61), respectively. Conclusions: The GDx GPA detected glaucoma progression in a significant number of cases showing progression by conventional methods, with high specificity and high positive LRs. Estimates of the accuracy for detecting progression suggest that the GDx GPA could be used to complement clinical evaluation in the detection of longitudinal change in glaucoma. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2010; 117: 462-470 (C) 2010 by the American Academy of Ophthalmology.
Resumo:
Background/purpose: The introduction of the piggyback technique for reconstruction of the liver outflow in reduced-size liver transplants for pediatric patients has increased the incidence of hepatic venous outflow block (HVOB). Here, we proposed a new technique for hepatic venous reconstruction in pediatric living-donor liver transplantation. Methods: Three techniques were used: direct anastomosis of the orifice of the donor hepatic veins and the orifice of the recipient hepatic veins (group 1); triangular anastomosis after creating a wide triangular orifice in the recipient inferior vena cava at the confluence of all the hepatic veins (group 2); and a new technique, which is a wide longitudinal anastomosis performed at the anterior wall of the inferior vena cava (group 3). Results: In groups 1 and 2, the incidences of HVOB were 27.7% and 5.7%, respectively. In group 3, no patient presented HVOB (P = .001). No difference was noted between groups 2 and 3. Conclusions: Hepatic venous reconstruction in pediatric living-donor liver transplantation must be preferentially performed by using a wide longitudinal incision at the anterior wall of the recipient inferior vena cava. As an alternative technique, triangulation of the recipient inferior vena cava, including the orifices of the 3 hepatic veins, may be used. Published by Elsevier Inc.
Resumo:
Background: Several studies have shown that robot-assisted laparoscopic radical prostatectomy (RALP) is feasible, with favorable complication rates and short hospital times. However, the early recovery of urinary continence remains a challenge to be overcome. Objective: We describe our technique of periurethral retropubic suspension stitch during RALP and report its impact on early recovery of urinary continence. Design, setting, and participants: We analyze prospectively 331 consecutive patients who underwent RALP, 94 without the placement of suspension stitch (group 1) and 237 with the application of the suspension stitch (group 2). Surgical procedure: The only difference between the groups was the placement of the puboperiurethral stitch after the ligation of the dorsal venous complex (DVC). The periurethral retropubic stitch was placed using a 12-in monofilament polyglytone suture on a CTI needle. The stitch was passed from right to left between the urethra and DVC, and then through the periostium on the pubic bone. The stitch was passed again through the DVC, and then through the pubic bone in a figure eight, and then tied. Measurements: Continence rates were assessed with a self-administered validated questionnaire (Expanded Prostate Cancer Index Composite [EPIC] at 1, 3, 6, and 12 mo after the procedure. Continence was defined as the use of no absorbent pads or no leakage of urine. Results and limitations: In group 1, the continence rate at 1, 3, 6, and 12 mo postoperatively was 33%, 83%, 94.7%, and 95.7%, respectively; in group 2, the continence rate was 40%, 92.8%, 97.9%, and 97.9%, respectively. The suspension technique resulted in significantly greater continence rates at 3 mo after RALP (p = 0.013). The median/mean interval to recovery of continence was also statistically significantly shorter in the suspension group (median: 6 wk; mean: 7.338 wk: 95% confidence interval [CI]: 6.387-8.288) compared to the non-suspension group (median: 7 wk; mean: 9.585 wk: 95% CI: 7.558-11.612; log rank test, p = 0.02). Conclusions: The suspension stitch during RALP resulted in a statistically significantly shorter interval to recovery of continence and higher continence rates at 3 mo after the procedure. (C) 2009 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Resumo:
Background: Enucleation of small lesions located near the hepatic surface can be achieved with low morbidity and mortality. This article describes a simple laparoscopic technique for enucleation of liver tumors. Methods: After inspection and intraoperative ultrasonography, Glisson`s capsule is marked with eletrocautery 2 cm away from the tumor margin. Ultrasonography is used to ascertain surgical margin right before liver transection. Hemihepatic ischemia is applied and marked area is anchored by stitches. The suture is held together by metallic clips and upward traction is performed, facilitating the transection of the parenchyma and correct identification of vascular and biliary structures. Results: This technique has been successfully employed in six consecutive patients. There were four men and two women, mean age 50.3 years. Four patients underwent liver resection for malignant disease and two for benign liver neoplasm. Pathologic surgical margins were free in all cases and mean hospital stay was 2 days. No postoperative mortality was observed. Conclusion: This technique may facilitate laparoscopic nonanatomical liver resection and reduce risk of positive surgical margins. It is also useful in combination with anatomical laparoscopic liver resections such as right or left hemihepatectomies in patients with bilateral liver tumors as occurred in one of our patients.
Resumo:
Experience with laparoscopic liver resections has increased in recent years, and so have the number of patients operated on by minimally invasive techniques. Specimen extraction is an important step of laparoscopic liver resection. The size of the specimen, is Usually a limitation for the use Of laparoscopy. The aim of this paper is to describe a new technique combining Pfannenstiel suprapubic incision and obstetric forceps to remove a large specimen from laparoscopic liver resections. The present technique allows an expeditious extraction of intact specimens, even huge ones, through a standard suprapubic Pfannenstiel incision. This technique has additional functional and cosmetic advantages over other techniques of specimen retrieval. We believe that the described technique is feasible, can be easily and rapidly performed, and facilitates laparoscopic liver resection by reducing the technical difficulties for specimen removal and may also be used in other abdominal laparoscopic interventions that deal with large surgical specimens.
Resumo:
Bleeding is not uncommon following endoscopic sphincterotomy. Supra-papillary puncture (SPP) might be safer than standard cannulation (SC) techniques in patients with coagulopathy. The aim of the study was to compare the safety and effectiveness of SPP and SC. This was a prospective case control intervention study. Decompensated cirrhotic patients with coagulopathy and choledocolithiasis underwent SC and SPP methods for biliary access. One hundred five patients (56 [53.3%] men, mean [SD] age 56 [15.8]) underwent ERCP. SC and SPP were performed in 63 and 42 patients, respectively. Biliary access was achieved in 56/63 (89%) and 40/42 (95%) of patients undergoing SC and SPP, respectively (P = 0.13; 95% CI [-0.16; 0.03]). Complications occurred in 10/63 (15.8%) patients undergoing SC and 5/42 (11.9%) SPP (P = 0.28; 95% CI [-0.17, 0.16]). Five (7.9%) and two (3.2%) episodes of post-sphincterotomy bleeding was seen in the SC and SPP groups, respectively (P = 0.36; 95% CI [-0.16, 0.05]). In contrast, three (4.8%) episodes of pancreatitis were seen in the SC and none in the SPP group (P = 0.05; 95% CI [0.001; 0.004]). A cost-effectiveness analysis demonstrated that SPP is an acceptable alternative at an ICER of US$ 5,974.92 per additional successful procedure. SPP is a safe and effective technique for the management of common bile duct stones in decompensated cirrhotic patients. Conditional to the willingness-to-pay and to the local ERCP-related costs, SPP is also a cost-effective alternative to the SC methods. SPP is associated with a lower rate of complications but larger studies to validate these findings are necessary.
Resumo:
PURPOSE: To compare the abilities of scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) and variable corneal compensation (VCC) modes for detection of retinal nerve fiber layer (RNFL) loss in eyes with band atrophy (BA) of the optic nerve. DESIGN. Cross-sectional study. METHODS: Thirty-seven eyes from 37 patients with BA and temporal visual field defect from chiasmal compression and 40 eyes from 40 healthy subjects were studied. Subjects underwent standard automated perimetry and RNFL measurements using an SLP device equipped with VCC and ECC. Receiver operating characteristic (ROC) curves were calculated for each parameter. Pearson correlation coefficients were obtained to evaluate the relationship between RNFL thickness parameters and severity of visual field loss, as assessed by the temporal mean defect. RESULTS: All RNFL thickness parameters were significantly lower in eyes with BA compared with normal eyes with both compensation modes. However, no statistically significant differences were observed in the areas under the ROC curves for the different parameters between GDx VCC and ECC (Carl Zeiss Meditec, Inc, Dublin, California, USA). Structure-function relationships also were similar for both compensation modes. CONCLUSIONS: No significant differences were found between the diagnostic accuracy of GDx ECC and that of VCC for detection of BA of the optic nerve. The use of GDx ECC does not seem to provide a better evaluation of RNFL loss on the temporal and nasal sectors of the peripapillary retina in subjects with BA of the optic nerve.
Resumo:
Background: Double-balloon enteroscopy (DBE) allows evaluation and therapy for various small bowel diseases. In this series the outcome of a 4-year experience in a tertiary hospital school in Brazil is reported. Methods: A total of 457 consecutive DBE were performed in 418 patients from August 2004 to August 2008. 93 patients with several indications, whose aim was not the evaluation of suspected diseases of the small bowel mucosa, were excluded, therefore leaving 364 DBE in 325 patients for analysis. Data were retrospectively collected with regard to clinical, endoscopic findings, therapy and complications. Results: Among the 364 DBE performed in 325 patients, 143/325 were males (44%) and 182/325 females (56%) with a mean age of 48.6 +/- 15.7 years (range 17-89). Mean investigation time was 64 +/- 22 min (range 35-135). The depth of insertion beyond the ligament of Treitz was 230 +/- 85 cm (range 30-500) by the antegrade approach and 140 +/- 75 cm (range 0-320) by the retrograde approach. Total enteroscopy was achieved in 41.66% of the attempts (30 of 72 patients). Overall diagnostic yield was 54.95% (200 of 364 procedures) ranging from 0 to 100% in this series, depending on the indication. Angiodysplasia was the main diagnosis in 24.5% (49 of 200 procedures) and endoscopic treatment, including biopsies, hemostasis, tattooing and polypectomy were performed in 65.38% (238 of 364 procedures). No major complications were reported. Conclusions: DBE is a feasible, safe and well-tolerated procedure allowing endoscopic therapy. Selection of indications increases its diagnostic yield. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
The NO donor trans-[Ru(NO)(NH(3))(4)(py)](BF(4))(3).H(2)O (py = pyridine) was loaded into poly-lactic-co-glycolic acid (PLGA) microparticles using the double emulsification technique. Scanning electron microscopy (SEM) and dynamic light scattering revealed that the particles are spherical in shape, have a diameter of 1600 nm, and have low tendency to aggregate. The entrapment efficiency was 25%. SEM analysis of the melanoma cell B16-F10 in the presence of the microparticles containing the complex trans-[Ru(NO)(NH(3))(4)(py)](BF(4))(3).H(2)O (pyMP) showed that the microparticles were adhered to the cell surface after 2 h of incubation. The complex with concentrations lower than 1 x 10(-4) M did not show toxicity in B16-F 10 murine cells. The complex in solution is toxic at higher concentrations (> 1 x 10(-3) M), with cell death attributed to NO release following the reduction of the complex. pyMP is not cytotoxic due to the lower bioavailability and availability of the entrapped complex to the medium and its reducing agents. However, pyMP is phototoxic upon light irradiation. The phototoxicity strongly suggests that cell death is due to NO release from trans-[Ru(NO)(NH(3))(4)(py)](3+). This work shows that pyMP can serve as a model for a drug delivery system carrying the NO donor trans-[Ru(NO)(NH(3))(4)(py)](BF(4))(3).H(2)O, which can release NO locally at the tumor cell by radiation with light only. (c) 2007 Elsevier Inc. All rights reserved.
Resumo:
Background: Most cases of congenital clubfoot treated with the Ponseti technique require percutaneous Achilles tenotomy to correct the residual equinus. Clinical evidence suggests that complete healing occurs between the cut tendon stumps, but there have not yet been any detailed studies investigating this reparative process. This study was performed to assess Achilles tendon repair after percutaneous section to correct the residual equinus of clubfoot treated with the Ponseti method. Method: A prospective study analyzed 37 tenotomies in 26 patients with congenital clubfoot treated with the Ponseti technique, with a minimum follow-up of 1 year after the section. The tenotomy was performed percutaneously with a large-bore needle bevel with patient sedation and local anesthesia. Ultrasonographic scanning was performed after section to ascertain that the tenotomy had been completed and to measure the stump separation. In the follow-up period, the reparative process was followed ultrasonographically and assessed at 3 weeks, 6 months, and 1 year posttenotomy. Results: The ultrasonography performed immediately after the procedure showed that in some cases, residual strands between the tendon ends persisted, and these were completely sectioned under ultrasound control. A mean retraction of 5.65 mm +/- 2.26 mm (range, 2.3 to 11.0 mm) between tendon stumps after section was observed. Unusual bleeding occurred in one case and was controlled by digital pressure, with no interference with the final treatment. After 3 weeks, ultrasonography showed tendon repair with the tendon gap filled with irregular hypoechoic tissue, and also with transmission of muscle motion to the heel. Six months after tenotomy, there was structural filling with a fibrillar aspect, mild or moderate hypoechogenicity, and tendon scar thickening when compared with a normal tendon. One year after tenotomy, ultrasound showed a fibrillar structure and echogenicity at the repair site that was similar to a normal tendon, but with persistent tendon scarring thickness. Conclusions: There is a fast reparative process after Achilles tendon percutaneous section that reestablishes continuity between stumps. The reparative tissue evolved to tendon tissue with a normal ultrasonographic appearance except for mild thickening, suggesting a predominantly intrinsic repair mechanism.
Resumo:
The aim of this study was to establish normal ranges of blood flow velocities and indices in the fetal ductus venosus (DV) during the second half of normal pregnancy. A Doppler study of 60 healthy pregnant women without fetal pathologies was performed during the second half of pregnancy. The peak systolic velocity (PSV), peak diastolic velocity (PDV), maximum velocity during atrial contraction (VAC), peak systolic velocity/maximum velocity during atrial contraction (S/A ratio), pulsatility index for the vein (PIV), preload index (PLI) and velocity index for the vein (VIV) were calculated from the DV at 4-week intervals. A significant increase in PSV, PDV and VAC was observed from the 20-23(6/7) to the 28-31(6/7) weeks, with stabilization of values until the end of the pregnancy. On the other hand, the study showed a significant decrease for the S/A ratio, PIV, PLI and VIV from the 20-23(6/7) to the 28-31(6/7) weeks and remaining stable from then until term. (E-mail:dralemar@uol.com.br) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Dorsal root ganglionectomy for the diagnosis of sensory neuropathies. Surgical technique and results
Resumo:
Background: Inflammatory diseases stand out among sensory neuronopathies because, in their active phase, they can be treated with immunosuppressive agents. Immunosuppressive therapy may present severe adverse effects and requires previous inflammatory activity confirmation. Sensory neuronopathies are diagnosed based on clinical and EMG findings. Diagnostic confirmation and identification of inflammatory activity are based on sensory ganglion histopathological examination. We describe the surgical technique used for dorsal root ganglionectomy in patients with clinical/EMG diagnosis of sensory neuronopathies. Methods: The sensory ganglion was obtained from 15 patients through a small T7-T8 hemilaminectomy and foraminotomy to expose the C7 root from its origin to the spinal nerve bifurcation. In 6 patients, the dural cuff supposed to contain the ganglion was resected en bloc; and in 9 patients, the ganglion was obtained through a longitudinal incision of the dural cuff and microsurgical dissection from the ventral and dorsal roots and radicular arteries. All ganglia were histopathologically examined. Results: No ganglion was found in the dural cuff in 2 patients submitted to en bloc removal, and the ganglion was removed in all patients who underwent microsurgical dissection. All but 2 patients that had ganglion examination presented a neuronopathy of nerve cell loss, 3 with mononuclear inflammatory infiltrate. These patients underwent immunosuppressive therapy, and 2 of them presented clinical improvement. No surgical complications were observed. Conclusions: Microsurgical dorsal root ganglionectomy for diagnosing inflammatory sensory ganglionopathies was effective and safe. Although safe, en bloc resection of the proximal dural cuff was not effective for this purpose. (c) 2008 Published by Elsevier Inc.
Resumo:
Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Objectives: To determine the differences between tympanic and extratympanic electrodes regarding recording technique, comfort and ease of execution of the exam, and quality of auditory potential tracings. Study Design: Prospective cross-section investigation. Methods: Determination of the summation potential/action potential (SP/AP) ratio by electrocochleography (EchoG) using tympanic and extratympanic electrodes and separate analysis of SP and AP regarding the amplitude recorded. Results: Twenty-three subjects (15 men and 8 women; mean age: 33.17 years) with normal tonal threshold audiometry were evaluated. EchoG analysis revealed no significant difference between the two tympanic electrodes. Eleven of the 23 subjects reported discomfort with the insertion of the tympanic electrode even with the use of topical xylocaine, whereas no complaints of discomfort were reported with the use of the extratympanic electrode. Conclusions: Both electrodes were effective for EchoG evaluation, but the extratympanic one was easier to insert and did not cause discomfort. However, the tympanic electrode produced tracings of greater amplitude and of better reproducibility. Laryngoscope, 119:563-566, 2009