181 resultados para Mandible deviation
Resumo:
Background: This prospective and controlled histologic study evaluates the impact of smoking on bone-to-implant contact, the bone density in the threaded area, and the bone density outside the threaded area around microimplants with anodized surface retrieved from human jaws. Methods: A total of 24 subjects (mean age 51.32 +/- 7.5 years) were divided in two groups: smokers (n = 13 subjects) and non-smokers (n = 11 subjects). Each subject received one microimplant with oxidized surface during conventional mandible or maxilla implant surgery. After 8 weeks, the microimplants and the surrounding tissue were removed and prepared for histomorphometric analysis. Results: Three microimplants placed in smokers showed no osseointegration. The newly formed bone showed early stages of maturation, mainly in the non-smokers. Marginal bone loss, gap, and fibrous tissue were present around implants retrieved from smokers. Histometric evaluation indicated that the mean bone-to-implant contact ranged between 25.97% +/- 9.02% and 40.01% +/- 12.98% for smokers and non-smokers, respectively (P <0.001). Smokers presented 28.17% +/- 10.32% of bone density in the threaded area, whereas non-smokers showed 46.34% +/- 19.12%. The mean of bone density outside the threaded area ranged between 18.76% and 25.11% for smokers and non-smokers, respectively (P>0.05). Conclusion: The present data obtained in human subjects confirm that smoking has a detrimental effect on early bone tissue response around oxidized implant surfaces. J Periodontol 2010;81:575-583.
Resumo:
Genial tubercles usually are small bony protuberances on the lingual aspect of the mandible symphysis. Conversely, this case shows 3D tomographic reconstruction images of genial tubercles as an oversized projection causing pain and discomfort to the patient.
Resumo:
Fibrous dysplasia is a benign fibro-osseous disease that affects one or more bones. Although its etiology has been defined, the mechanism of spontaneous resolution is still unclear. There is strong evidence indicating the occurrence of stabilization when bone maturation is completed. Deformities that lead to esthetic and functional disorders are observed in almost all cases. Plastic surgery is often recommended when the maxilla and mandible are involved. In the case of mild deformities, careful follow-up during skeletal growth is recommended. We describe here the 23-year follow-up of a patient with monostotic fibrous dysplasia whose disease had stabilized by 13 years of follow-up. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: 229-234)
Resumo:
This study evaluated the biomechanical and microscopic response of previously grafted bone to titanium implants. The lower incisors of 16 rabbits were surgically extracted, and bilateral perforations communicating with the remaining sockets were created distally. A socket/perforation defect on each mandible was chosen at random to be immediately filled with a xenogenic graft, whereas the contralateral perforation was left to heal naturally and served as a paired control. After 60 days, titanium implants were installed in the previously operated areas. After periods of 2 and 6 months, the animals were killed, and the force necessary to retrieve implants as well as the bone-implant contact (BIC) and bone mass (BM) were quantified and statistically compared by 2-way analysis of variance and Tukey`s test (alpha = .05). No significant differences in removal torque were observed, either by time or by treatment condition. Differences in BIC and BM between experimental and control groups were not statistically significant through the intervals studied (P < .05). The presence of a xenogenic graft did not influence the microscopic tissue response to titanium implants or fixation into newly formed or mature bone.
Resumo:
Purpose: The purpose of this study was to evaluate the amount of dentifrice applied to the toothbrush by school children using a liquid dentifrice (drop technique), when compared to toothpaste. Materials and Methods: A total of 178 school children (4-8 years old) from two cities in Brazil (Bauru and Bariri) participated in the present two-part crossover study. Children from Bauru received training regarding tooth-brushing techniques and use of dentifrice before data collection. In each phase, the amount of toothpaste or liquid dentifrice applied by the children to the toothbrush was measured, using a portable analytical balance (+/- 0.01 g). Data were tested by analysis of covariance (Ancova) and linear regression (p < 0.05). Results: The mean (+/- standard deviation) amounts of toothpaste and liquid dentifrice applied to the toothbrushes for children from Bauru were 0.41 +/- 0.20 g and 0.15 +/- 0.06 g, respectively. For children from Bariri, the amounts applied were and 0.48 +/- 0.24 g and 0.14 +/- 0.05 g, respectively. The amount of toothpaste applied was significantly larger than the amount of liquid dentifrice for both cities. Children from Bariri applied a significantly larger amount of toothpaste, when compared to those from Bauru. However, for the liquid dentifrice, there was no statistically significant difference between the cities. A significant correlation between the amount of toothpaste applied and the age of the children was verified, but the same was not found for the liquid dentifrice. Conclusion: The use of the drop technique reduced and standardised the amount of dentifrice applied to the toothbrush, which could reduce the risk of dental fluorosis for young children.
Resumo:
Establishment of a treatment plan is based on efficacy and easy application by the clinician, and acceptance by the patient. Treatment of adult patients with Class III malocclusion might require orthognathic surgery, especially when the deformity is severe, with a significant impact on facial esthetics. Impacted teeth can remarkably influence treatment planning, which should be precise and concise to allow a reasonably short treatment time with low biologic cost. We report here the case of a 20-year-old man who had a skeletal Class III malocclusion and impaction of the maxillary right canine, leading to remarkable deviation of the maxillary midline; this was his chief complaint. Because of the severely deviated position of the impacted canine, treatment included extraction of the maxillary right canine and left first premolar for midline correction followed by leveling, alignment, correction of compensatory tooth positioning, and orthognathic surgery to correct the skeletal Class III malocclusion because of the severe maxillary deficiency. This treatment approach allowed correction of the maxillary dental midline discrepancy to the midsagittal plane and establishment of good occlusion and optimal esthetics. (Am J Orthod Dentofacial Orthop 2010;137:840-9)
Resumo:
Introduction: Mini-implants are placed in restricted sites, requiring an accurate surgical technique. However, no systematic study has quantified technique accuracy to reliably predict the surgical risks. Therefore, a graduated 3-dimensional radiographic-surgical guide (G-RSG) was proposed, and its inaccuracy and risk index (RI) were estimated. Methods: The sample consisted of 6 subjects (4 male, 2 female), who used mini-implant anchorage. Ten drill-free screws (DFS) were placed by using the G-RSG. The central point of the mesiodistal septum width (SW) was the selected implant site on the presurgical radiograph. The distances between DFS and the adjacent teeth (5-DFS and 6-DFS) were measured to evaluate screw centralization and inaccuracy degree (ID). These distances were statistically compared by independent t tests, and inaccuracy was determined by the expression ID = (5-DFS-6-DFS)/2, which represents deviation of the mini-implant`s final position regarding the central point initially selected. Then SW, ID, and screw diameter (SO) were combined to estimate the surgical risk with RI expressed by RI = SO/SW-ID. Results: The 5-DFS and 6-DFS distances were not significantly different. The ID of the G-RSG was 0.17 mm. The low ID ensured a safe RI (<1) in spite of the restricted SW. Conclusions: The G-RSG accuracy allowed fine prediction of the final DFS position in the inter-radicular septum, with a low RI, which is a helpful tool to estimate surgical risks. (Am J Orthod Dentofacial Orthop 2009; 136: 722-35)
Resumo:
This case report describes the nonsurgical, nonextraction therapy of a 16-year-old boy with a skeletal Class III malocclusion, a prognathic mandible, and a retrusive maxilla. He was initially classified as needing orthognathic surgery, but he and his parents wanted to avoid that. The Class III malocclusion was corrected with a rapid palatal expander and a maxillary protraction mask followed by nonextraction orthodontic treatment with fixed appliances, combined with short Class III and vertical elastics in the anterior area. The height of the maxillary alveolar process and the vertical face height were slightly increased with treatment. Class I molar and canine relationships were achieved, and the facial profile improved substantially. (Am J Orthod Dentofacial Orthop 2009; 136: 736-45)
Resumo:
This study compared the effects produced by two different molar distalizers, namely cervical headgear (CHG) and the intraoral pendulum appliance, associated with fixed orthodontic appliances. The headgear group comprised 30 patients (19 females, 11 males), with an initial age of 13.07 years [standard deviation (SD) = 1.3], treated with CHG and fixed orthodontic appliances for a mean period of 3.28 years, and the pendulum group 22 patients (15 females, 7 males), with initial age of 13.75 years (SD = 1.86), treated with the pendulum appliance followed by fixed orthodontic appliances for a mean period of 4.12 years. Lateral cephalograms were taken at the start (T1) and on completion (T2) of orthodontic treatment. The pendulum and CHG groups were similar as to initial age, severity of the Class II malocclusion, gender distribution, initial cephalometric characteristics, and initial and final treatment priority index (TPI). Only treatment time was not similar between the groups, with a need for annualization for data for the pendulum group. The data were compared with independent t-tests. There was significantly greater restriction of maxillary forward growth and improvement of the skeletal maxillomandibular relationship in the CHG group (P < 0.05). The maxillary molars were more mesially tipped and extruded and the mandibular molars more uprighted in the CHG group compared with the pendulum group (P < 0.05). There was more labial tipping of the mandibular incisors and greater overbite reduction in the pendulum group. The pendulum appliance produced only dentoalveolar effects, different from the CHG appliance, which restricted maxillary forward displacement, thus improving the skeletal maxillomandibular relationship.
Resumo:
Background: Understanding how clinical variables affect stress distribution facilitates optimal prosthesis design and fabrication and may lead to a decrease in mechanical failures as well as improve implant longevity. Purpose: In this study, the many clinical variations present in implant-supported prosthesis were analyzed by 3-D finite element method. Materials and Method: A geometrical model representing the anterior segment of a human mandible treated with 5 implants supporting a framework was created to perform the tests. The variables introduced in the computer model were cantilever length, elastic modulus of cancellous bone, abutment length, implant length, and framework alloy (AgPd or CoCr). The computer was programmed with physical properties of the materials as derived from the literature, and a 100N vertical load was used to simulate the occlusal force. Images with the fringes of stress were obtained and the maximum stress at each site was plotted in graphs for comparison. Results: Stresses clustered at the elements closest to the loading point. Stress increase was found to be proportional to the increase in cantilever length and inversely proportional to the increase in the elastic modulus of cancellous bone. Increasing the abutment length resulted in a decrease of stress on implants and framework. Stress decrease could not be demonstrated with implants longer than 13 mm. A stiffer framework may allow better stress distribution. Conclusion: The relative physical properties of the many materials involved in an implant-supported prosthesis system affect the way stresses are distributed.
Resumo:
Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The aim of this study was to analyze if the presence of impacted third molars, and their positions in the mandibular angle, can change the bone quality in this area, considering the measure of the cortical thickness in this region as representative or not for mandible fracture risk. Software was used to analyze 50 digital images from panoramic radiographs of patients who had one or two impacted third molars in the mandible, and 30 digital images of patients with agenesis of the mandibular third molar. The thickness of the cortical region of the mandible was measured; it was possible to draw a parallel line to the posterior portion of the mandible and a parallel line to the body of this bone on each side of the image. At the intersection of these lines near the distal portion of the second molar, another line was set up to serve as reference in the cortical thickness measurement. It could be concluded that the cortical thickness of the mandibular angle in male patients without impacted third molars was greater than the thickness in patients with these teeth, and no difference in thickness was found for the female group.
Resumo:
The objective of this study was to evaluate the bone repair along a mandibular body osteotomy after using a 2.0 miniplate system. Nine adult mongrel dogs were subjected to unilateral continuous defect through an osteotomy between the mandibular 3rd and 4th premolars. Two four-hole miniplates were placed in accordance with the Arbeitgeimeinschaft fur Osteosynthesefragen Manual. Miniplates adapted to the alveolar processes were fixed monocortically with 6.0-mm-length titanium alloy self-tapping screws, whereas miniplates placed near the mandible bases were fixed bicortically. At 2, 6 and 12 weeks, three dogs were sacrificed per period, and the osteotomy sites were removed, divided into three thirds (Tension Third, TT; Intermediary Third, IT; Compression Third, CT) and prepared for conventional and polarized light microscopy. At 6 weeks, while the CT repaired faster and showed bone union by woven bone formation, the TT and IT exhibited a ligament-like fibrous connective tissue inserted in, and connecting, newly formed woven bone overlying the parent lamellar bone edges. At 12 weeks, bone repair took place at all thirds. Histometrically, proportions of newly formed bone did not alter at TT, IT and CT, whereas significantly enhanced bone formation was observed for the 12-week group, irrespective of the third. The results demonstrated that although the method used to stabilize the mandibular osteotomy allowed bone repair to occur, differences in the dynamics of bone healing may take place along the osteotomy site, depending on the action of tension and compression forces generated by masticatory muscles.
Resumo:
Aim. The aim of this study was to evaluate the concentration of calcium ions and smear layer removal by using root canal chelators according to flame atomic absorption spectrophotometry and scanning electron microscopy. Forty-two human maxillary central incisors were irrigated with 15% ethylenediaminetetraacetic acid (EDTA), 10% citric acid, 10% sodium citrate, apple vinegar, 5% acetic acid, 5% malic acid, and sodium hypochlorite. The concentration of calcium ions was measured by using flame atomic absorption spectrometry, and smear layer removal was determined by scanning electron microscopy. Mean +/- standard deviation, one-way analysis of variance, Tukey-Kramer, Kruskal-Wallis, Dunn, and kappa tests were used for statistical analysis. The use of 15% EDTA resulted in the greatest concentration of calcium ions followed by 10% citric acid; 15% EDTA and 10% citric acid were the most efficient solutions for removal of smear layer. (J Endod 2009;35:727-730)
Resumo:
Background Long-term success of the implant restorations is based upon the biology and vasculature of the bone surrounding the implants, especially for the bone between two implants. Purpose The aim of this study was to evaluate how loaded implants placed 2 or 3 mm apart influence bone vessel organization. Material and methods Six mongrel dogs were used for the study. The four mandibular premolars were extracted and 3 months later, four 4.5 x 10 mm implants were placed on each side of the mandible. The implants were placed so that two adjacent implants were 2 mm (group 1) or 3 mm (group 2) distant from each other. After 12 weeks, the implants were loaded with provisional prostheses, then metallic crowns were placed 4 weeks later. Both temporary and metallic restorations were made so that the distance between the contact point and the bone crest was 5 mm. The animals were sacrificed after 8 weeks. The hemi-mandibles were removed and prepared for analysis. The interimplant bone vasculature of the two groups was studied using scanning electron microscopic images fractal analysis. The fractal dimension (D(f)) was calculated using the box-counting method. Results The values of the D(f) for the blood vessels were significantly higher (P <.05) in the specimens of the group 2 (1.969 +/- 0.169) than the group 1 (1.556 +/- 0.246). Conclusion The presence of more blood vessels in the group 2 is another indication that 3 mm is a preferable distance for contiguous implants than the 2 mm distance. To cite this article:Traini T, Novaes AB, Piattelli A, Papalexiou V, Muglia VA. The relationship between interimplant distances and vascularization of the interimplant bone.Clin. Oral Impl. Res. 21, 2010; 822-829.doi: 10.1111/j.1600-0501.2010.01926.x.