179 resultados para Design variables
Resumo:
Objective To compare the cardiorespiratory, anesthetic-sparing effects and quality of anesthetic recovery after epidural and constant rate intravenous (IV) infusion of dexmedetomidine (DEX) in cats given a low dose of epidural lidocaine under propofol-isoflurane anesthesia and submitted to elective ovariohysterectomy. Study design Randomized, blinded clinical trial. Animals Twenty-one adult female cats ( mean body weight: 3.1 +/- 0.4 kg). Methods Cats received DEX (4 mu g kg(-1), IM). Fifteen minutes later, anesthesia was induced with propofol and maintained with isoflurane. Cats were divided into three groups. In GI cats received epidural lidocaine (1 mg kg(-1), n = 7), in GII cats were given epidural lidocaine (1 mg kg(-1)) + DEX (4 mu g kg(-1), n = 7), and in GIII cats were given epidural lidocaine (1 mg kg(-1)) + IV constant rate infusion (CRI) of DEX (0.25 mu g kg(-1) minute(-1), n = 7). Variables evaluated included heart rate (HR), respiratory rate (f(R)), systemic arterial pressures, rectal temperature (RT), end-tidal CO(2), end-tidal isoflurane concentration (E`ISO), arterial blood gases, and muscle tone. Anesthetic recovery was compared among groups by evaluation of times to recovery, HR, f(R), RT, and degree of analgesia. A paired t-test was used to evaluate pre-medication variables and blood gases within groups. ANOVA was used to compare parametric data, whereas Friedman test was used to compare muscle relaxation. Results Epidural and CRI of DEX reduced HR during anesthesia maintenance. Mean +/- SD E/ISO ranged from 0.86 +/- 0.28% to 1.91 +/- 0.63% in GI, from 0.70 +/- 0.12% to 0.97 +/- 0.20% in GII, and from 0.69 +/- 0.12% to 1.17 +/- 0.25% in GIII. Cats in GII and GIII had longer recovery periods than in GI. Conclusions and clinical relevance Epidural and CRI of DEX significantly decreased isoflurane consumption and resulted in recovery of better quality and longer duration, despite bradycardia, without changes in systemic blood pressure.
Resumo:
Objective To evaluate the post-operative analgesic effect of metamizol (dipyrone) administered intravenously at three different doses (15 mg kg(-1), 25 mg kg(-1) and 35 mg kg(-1)) compared to placebo in dogs undergoing ovariohysterectomy. Study design Prospective, comparative, randomized. blinded trial. Animals Forty healthy bitches, aged 1-6 years, weighing 10-35 kg Methods The animals were randomly divided into four groups and received their respective treatments immediately after surgery: placebo group (0.9% saline solution), D15 group (metamizol 15 mg kg(-1) IV), D25 group (metamizol 25 mg kg(-1) IV), D35 group (metamizol 35 mg kg(-1) IV). The following variables were measured: sedation, pulse rate (PR). respiratory rate (f(R)). arterial blood pressure (ABP), plasma catecholamines. serum cortisol, blood urea nitrogen (BUN) and creatinine metabolites. albumin, alanine aminotransferase (ALT), alkaline phosphatase (ALP). hemogram. platelet counts and level of analgesia which was assessed by visual analog (VAS). descriptive and behavioral scales. Patients were monitored for 48 hours after the administration of the analgesic agent. Rescue analgesia (tramadol, 2 mg kg(-1), intramuscularly) was provided for animals with pain scores >= 4, as determined by the VAS or descriptive scale. Results The D25 and D35 groups showed equivalent post-operative analgesia, as shown by decreased pain scores, according to the three different pain scales, and fewer animals that required rescue analgesia. Significantly lower serum cortisol concentrations were observed in the D25 and D35 groups when compared to the placebo and D15 groups. No hematologic, renal, hepatic or clinical adverse effects were observed during the treatment. Conclusions and clinical relevance Metamizol administered intravenously at 25 or 35 mg kg(-1) can provide adequate post-operative analgesia in bitches undergoing ovariohysterectomy.
Resumo:
Nine ruminally cannulated cows fed different energy sources were used to evaluate an avian-derived polyclonal antibody preparation (PAP-MV) against the specific ruminal bacteria Streptococcus bovis, Fusobacterium necrophorum, Clostridium aminophilum, Peptostreptococcus anaerobius, and Clostridium stick-landii and monensin (MON) on ruminal fermentation patterns and in vivo digestibility. The experimental design was three 3 x 3 Latin squares distinguished by the main energy source in the diet [dry-ground corn grain (CG), high-moisture corn silage (HMCS), or citrus pulp (CiPu)]. Inside each Latin square, animals received one of the feed additives per period [none (CON), MON, or PAP-MV]. Dry matter intake and ruminal fermentation variables such as pH, total short-chain fatty acids (tSCFA), which included acetate, propionate, and butyrate, as well as lactic acid and NH(3)-N concentration were analyzed in this trial. Total tract DM apparent digestibility and its fractions were estimated using chromic oxide as an external marker. Each experimental period lasted 21 d. Ruminal fluid sampling was carried out on the last day of the period at 0, 2, 4, 6, 8, 10, and 12 h after the morning meal. Ruminal pH was higher (P = 0.006) 4 h postfeeding in MON and PAP-MV groups when compared with CON. Acetate: propionate ratio was greater in PAP-MV compared with MON across sampling times. Polyclonal antibodies did not alter (P > 0.05) tSCFA, molar proportion of acetate and butyrate, or lactic acid and NH(3)-N concentration. Ruminal pH was higher (P = 0.01), 4 h postfeeding in CiPu diets compared with CG and HMCS. There was no interaction between feed additive and energy source (P > 0.05) for any of the digestibility coefficients analyzed. Starch digestibility was less (P = 0.008) in PAP-MV when compared with CON and MON. In relation to energy sources, NDF digestibility was greater (P = 0.007) in CG and CiPu vs. the HMCS diet. The digestibility of ADF was greater (P = 0.002) in CiPu diets followed by CG and HMCS. Feeding PAP-MV or monensin altered ruminal fermentation patterns and digestive function in cows; however, those changes were independent of the main energy source of the diet.
Resumo:
Objective To assess the effect of halothane (H), isoflurane (I) or sevoflurane (S) on the bispectral index (BIS), and the effect of the addition of meperidine in dogs subjected to ovariohysterectomy. Study design Prospective, randomized, blinded, clinical trial. Animals Forty-eight female mixed-breed dogs, with weights varying from 10 to 25 kg. Methods All dogs were premedicated with acepromazine (A) (0.1 mg kg(-1) IM) or A and meperidine (M) (3 mg kg(-1) IM) and they were divided into six groups of eight animals (AH, AMH, AI, AMI, AS, and AMS). Fifteen minutes after premedication they were anesthetized with propofol (5 mg kg(-1) IV) and then orotracheally intubated. Anesthesia was maintained with halothane, isoflurane or sevoflurane, respectively. The BIS, E`(anest) variables were recorded at 15 minutes after administering pre-anesthetic medication (T0); 10 minutes of anesthesia maintenance (T1); right ovarian pedicle ligation (T2); muscle suturing (T3); skin suture (T4) and 10 minutes after terminating the inhalant anesthetic (T5), respectively. Results BIS values were decreased at all times when compared to the baseline values in all groups (p < 0.05). In the comparative assessment between groups, the values obtained at T0 and T1 were similar for all groups. At T2, the values in AMH were lower than those obtained in AI, AMI and AS (p < 0.05). At the same time significantly higher values were found for AI when compared to AMS (p < 0.01). There was a correlation between the bispectral index and the expired anesthetic fraction in all groups. Conclusions and clinical relevance Within groups given the same inhalant anesthetic the bispectral index was a good indicator for the degree of hypnosis in dogs, indicating a good correlation with the amount of anesthetic and the nociceptive stimulation. BIS was a less reliable indicator of relative anesthetic depth when comparing equipotent end-tidal concentrations between the three inhalants.
Resumo:
Objective: To study the effect of freeze-thaw on embryos derived from intracytoplasmic sperm injection (ICSI) using surgically retrieved and ejaculated spermatozoa. Design: Retrospective study. Setting: Private IVF center. Patient(s): Three hundred eighty-three patients undergoing frozen-thawed ET cycles. Intervention(s): Testicular sperm aspiration (TESA) or percutaneous epididymal sperm aspiration (PESA) were the sperm surgical retrieval methods used for ICSI. Embryos resulting from ICSI using Surgically retrieved and ejaculated spermatozoa were frozen, thawed, and transferred. Main Outcome Measure(s): Post-thaw survival, implantation, and pregnancy rates. Result(s): No differences were found between the ejaculated sperm and TESA/PESA groups in terms of post-thaw survival rate (68.4% vs. 66.1%, respectively), pregnancy rate (20.1% vs. 16.1%), and implantation rate (10.6% vs. 12.7%). Similar results were found for those variables when comparing TESA and PESA groups. Conclusion(s): Cleavage embryos arising from ICSI cycles using testicular and epididymal spermatozoa can be frozen with survival, pregnancy,and implantation rates comparable to those obtained with ejaculated spermatozoa. (Fertil Steril (R) 2009;91:727-32. (C) 2009 by American Society for Reproductive Medicine.)
Resumo:
Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.
Resumo:
Purpose: The purpose of this study was to assess the influence of adhesive area delimitation on the microshear bond strength of different adhesives to dentin. Materials and Methods: Eighteen bovine incisors were sectioned and the exposed dentin surfaces were prepared with 600-grit SIC paper. These teeth were randomly divided into three groups, according to the adhesive to be applied: two-step etch-and-rinse Adper Single Bond 2 (3M ESPE), two-step self-etching Clearfil SE Bond (Kuraray), and one-step Clearfil S(3) Bond (Kuraray). On each dentin surface, 4 samples were built up with the composite resin Z100 (3M ESPE); on 2 of these, a suggested area delimitation technique was employed. After 24 h of storage in water at 37 degrees C, samples were subjected to the microshear bond strength test, and the failure modes were evaluated under optical and scanning electron microscopes. The obtained results were statistical analyzed using two-way ANOVA and Tukey`s test. Results: Groups without area delimitation presented significantly higher bond strength results (p < 0.05) and a higher incidence of cohesive failures. In these groups, fractures tended to occur beyond the limits of the actual adhesive area, while the area restriction technique succeeded in avoiding this phenomenon. The three adhesives performed similarly when area delimitation was employed (p > 0.05), but Clearfil S(3) Bond showed significantly higher bond strength results when no area delimitation was taken into account (p < 0.05). Conclusion: The extension of the adhesive area beyond the limits of the composite cylinder may play an important role in the results of microshear bond strength tests, while the suggested area delimitation technique may lead to less questionable outcomes.
Resumo:
Background. Dental erosion is a multifactorial disease and is associated with dietary habits in infancy and adolescence. Aim. To investigate possible associations among dental erosion and diet, medical history and lifestyle habits in Brazilian schoolchildren. Design. The sample consisted of a random single centre cluster of 414 adolescents (12- and 16-years old) of both genders from private and public schools in Bauru (Brazil). The O`Brien [Children`s Dental Health in the United Kingdom, 1993 (1994) HMSO, London] index was used for dental erosion assessment. Data on medical history, rate and frequency of food and drinks consumption, and lifestyle habits were collected by a self-reported questionnaire. Odds ratios with 95% confidence intervals were used to assess the univariate relationships between variables. Analysis of questionnaire items was performed by multiple logistic regression analysis. The statistical significance level was set at 5%. Results. The erosion present group comprised 83 subjects and the erosion absent group 331. There were no statistically significant correlations among dental erosion and the consumption of food and drinks, medical history, or lifestyle habits. Conclusion. The results indicate that there was no correlation between dental erosion and the risk factors analysed among adolescents in Bauru/Brazil and further investigations are necessary to clarify the multifactorial etiology of this condition.
Resumo:
This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.
Resumo:
Background: Understanding how clinical variables affect stress distribution facilitates optimal prosthesis design and fabrication and may lead to a decrease in mechanical failures as well as improve implant longevity. Purpose: In this study, the many clinical variations present in implant-supported prosthesis were analyzed by 3-D finite element method. Materials and Method: A geometrical model representing the anterior segment of a human mandible treated with 5 implants supporting a framework was created to perform the tests. The variables introduced in the computer model were cantilever length, elastic modulus of cancellous bone, abutment length, implant length, and framework alloy (AgPd or CoCr). The computer was programmed with physical properties of the materials as derived from the literature, and a 100N vertical load was used to simulate the occlusal force. Images with the fringes of stress were obtained and the maximum stress at each site was plotted in graphs for comparison. Results: Stresses clustered at the elements closest to the loading point. Stress increase was found to be proportional to the increase in cantilever length and inversely proportional to the increase in the elastic modulus of cancellous bone. Increasing the abutment length resulted in a decrease of stress on implants and framework. Stress decrease could not be demonstrated with implants longer than 13 mm. A stiffer framework may allow better stress distribution. Conclusion: The relative physical properties of the many materials involved in an implant-supported prosthesis system affect the way stresses are distributed.
Resumo:
Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.
Resumo:
This study evaluated the effect of core-design modification on the characteristic strength and failure modes of glass-infiltrated alumina (In-Ceram) (ICA) compared with porcelain fused to metal (PFM). Premolar crowns of a standard design (PFMs and ICAs) or with a modified framework design (PFMm and ICAm) were fabricated, cemented on dies, and loaded until failure. The crowns were loaded at 0.5 mm min(-1) using a 6.25 mm tungsten-carbide ball at the central fossa. Fracture load values were recorded and fracture analysis of representative samples were evaluated using scanning electron microscopy. Probability Weibull curves with two-sided 90% confidence limits were calculated for each group and a contour plot of the characteristic strength was obtained. Design modification showed an increase in the characteristic strength of the PFMm and ICAm groups, with PFM groups showing higher characteristic strength than ICA groups. The PFMm group showed the highest characteristic strength among all groups. Fracture modes of PFMs and of PFMm frequently reached the core interface at the lingual cusp, whereas ICA exhibited bulk fracture through the alumina core. Core-design modification significantly improved the characteristic strength for PFM and for ICA. The PFM groups demonstrated higher characteristic strength than both ICA groups combined.
Resumo:
Objective. To evaluate the influence of shaft design on the shaping ability of 3 rotary nickel-titanium (NiTi) systems. Study design. Sixty curved mesial canals of mandibular molars were used. Specimens were scanned by spiral tomography before and after canal preparation using ProTaper, ProFile, and ProSystem GT rotary instruments. One-millimeter-thick slices were scanned from the apical end point to the pulp chamber. The cross-sectional images from the slices taken earlier and after canal preparation at the apical, coronal, and midroot levels were compared. Results. The mean working time was 137.22 +/- 5.15 s. Mean transportation, mean centering ratio, and percentage of area increase were 0.022 +/- 0.131 mm, 0.21 +/- 0.11, and 76.90 +/- 42.27%, respectively, with no statistical differences (P > .05). Conclusions. All instruments were able to shape curved mesial canals in mandibular molars to size 30 without significant errors. The differences in shaft designs seemed not to affect their shaping capabilities.