221 resultados para Dent molar
Resumo:
Statement of problem. Dental fractures can occur in endodontically treated teeth restored with posts. Purpose. The purpose of this study was to evaluate the in vitro fracture resistance of roots with glass-fiber and metal posts of different lengths. Material and methods. Sixty endodontically treated maxillary canines were embedded in acrylic resin, except for 4 mm of the cervical area, after removing the clinical crowns. The post spaces were opened with a cylindrical bur at low speed attached to a surveyor, resulting in preparations with lengths of 6 mm (group 6 mm), 8 mm (group 8 mm), or 10 mm (group 10 mm). Each group was divided into 2 subgroups according to the post material: cast post and core or glass-fiber post (n=30). The posts were luted with dual-polymerizing resin cement (Panavia F). Cast posts and cores of Co-Cr (Resilient Plus) crowns were made and cemented with zinc phosphate. Specimens were subjected to increasing compressive load (N) until fracture. Data were analyzed with 2-way ANOVA and the Tukey-Kramer test (alpha=.05). Results. The ANOVA analysis indicated significant differences (P<.05) among the groups, and the Tukey test revealed no significant difference among the metal posts of 6-mm length (26.5 N +/- 13.4), 8-mm length (25.2 N +/- 13.9), and 10-mm length (17.1 N +/- 5.2). Also, in the glass-fiber post group, there was no significant difference when posts of 8-mm length (13.4 N +/- 11.0) were compared with the 6-mm (6.9 N +/- 4.6) and 10-mm (31.7 N +/- 13.1) groups. The 10-mm-long post displayed superior fracture resistance, and the 6-mm-long post showed significantly lower mean values (P<.001). Conclusions. Within the limitations of this study, it was concluded that the glass-fiber post represents a viable alternative to the cast metal post, increasing the resistance to fracture of endodontically treated canines. (J Prosthet Dent 2009;101:183-188)
Resumo:
Purpose: To assess, by a crossover 2 x 2 in situ study, the speculated protective role of a sodium bicarbonate-containing toothpaste in controlling erosive lesions. Methods: Bovine enamel slabs were sterilized, and submitted to baseline Knoop microhardness measurements. After a 3-day lead-in period, 14 volunteers wore palatal acrylic appliances containing six enamel slabs (three on each side), for 4 consecutive days. On the first day, appliances with contained specimens were placed in the oral cavity to allow salivary pellicle formation. On the subsequent days, half of the enamel slabs were immersed extraorally in a lemonade-like soft drink for 90 seconds, twice daily. On both of these occasions, the appliance was dipped in toothpaste slurry of either a sodium bicarbonate-containing toothpaste or a regular counterpart for 60 seconds. Following a 3-day washout period, a new set of enamel slabs were mounted and the volunteers started the second period using the alternate dentifrice. Results: ANOVA (alpha = 0.05) showed no statistically significant difference between enamel treated with regular and sodium bicarbonate-based dentifrices, regardless of whether specimens were eroded or not (P=0.8430). Acid-challenged specimens revealed lower microhardness values than uneroded samples. (Am J Dent 2008;21:300-302).
Resumo:
Background. Osteogenesis imperfecta (OI), also known as ""brittle bone disease,"" can be difficult to diagnose in its mild form. The authors describe a clinical case of a diagnosis of dentinogenesis imperfecta (DI), In which a literature review combined with an analysis of dental alterations led to indications of OI involvement. Case Description. Since DI can be associated with OI, the authors reviewed correlated studies and obtained a new medical history from the patient. They then conducted a radiographic and clinical examination of the dentition and submitted an affected third molar to scanning electron microscopy analysis. They compared their findings with descriptions of OI type I dental alterations in the literature and confirmed their diagnosis by means of a medical evaluation. Clinical Implications. In cases in which DI is diagnosed, patients should be examined carefully and the occurrence of OI should be considered `since, in its mild form, it might be misdiagnosed.
Resumo:
There is no consensus in literature regarding the best plan for prosthetic rehabilitation with partial multiple adjacent implants to minimize stress generated in the bone-implant interface. The aim of this study was to evaluate the biomechanical behavior of cemented fixed partial dentures, splinted and nonsplinted, on Morse taper implants and with different types of coating material (ceramic and resin), using photoelastic stress analysis. A photoelastic model of an interposed edentulous space, missing a second premolar and a first molar, and rehabilitated with 4 different types of cemented crowns and supported by 2 adjacent implants was used. Groups were as follows: UC, splinted ceramic crowns; IC, nonsplinted ceramic crowns; UR, splinted resin crowns; and IR, nonsplinted resin crowns. Different vertical static loading conditions were performed: balanced occlusal load, 10 kgf; simultaneous punctiform load on the implanted premolar and molar, 10 kgf; and alternate punctiform load on the implanted premolar and molar, 5 kgf. Changes in stress distribution were analyzed in a polariscope, and digital photographs were taken of each condition to allow comparison of stress pattern distribution around the implants. Cementation of the fixed partial dentures generated stresses between implants. Splinted restorations distributed the stresses more evenly between the implants than nonsplinted when force was applied. Ceramic restorations presented better distribution of stresses than resin restorations. Based on the results obtained, it was concluded that splinted ceramic restorations promote better stress distribution around osseointegrated implants when compared with nonsplinted crowns; metal-ceramic restorations present less stress concentration and magnitude than metal-plastic restorations.
Resumo:
This study compared splinted and non-splinted implant-supported prosthesis with and without a distal proximal contact using a digital image correlation method. An epoxy resin model was made with acrylic resin replicas of a mandibular first premolar and second molar and with threaded implants replacing the second premolar and first molar. Splinted and non-splinted metal-ceramic screw-retained crowns were fabricated and loaded with and without the presence of the second molar. A single-camera measuring system was used to record the in-plane deformation on the model surface at a frequency of 1.0 Hz under a load from 0 to 250 N. The images were then analyzed with specialist software to determine the direct (horizontal) and shear strains along the model. Not splinting the crowns resulted in higher stress transfer to the supporting implants when the second molar replica was absent. The presence of a second molar and an effective interproximal contact contributed to lower stress transfer to the supporting structures even for non-splinted restorations. Shear strains were higher in the region between the molars when the second molar was absent, regardless of splinting. The opposite was found for the region between the implants, which had higher shear strain values when the second molar was present. When an effective distal contact is absent, non-splinted implant-supported restorations introduce higher direct strains to the supporting structures under loading. Shear strains appear to be dependent also on the region within the model, with different regions showing different trends in strain changes in the absence of an effective distal contact. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Modified fluorcanasite glasses were fabricated by either altering the molar ratios of Na(2)O and CaO or by adding P(2)O(5) to the parent stoichiometric glass compositions. Glasses were converted to glass-ceramics by a controlled two-stage heat treatment process. Rods (2 mm x 4 mm) were produced using the conventional lost-wax casting technique. Osteoconductive 45S5 bioglass was used as a reference material. Biocompatibility and osteoconductivity were investigated by implantation into healing defects (2 mm) in the midshaft of rabbit femora. Tissue response was investigated using conventional histology and scanning electron microscopy. Histological and histomorphometric evaluation of specimens after 12 weeks implantation showed significantly more bone contact with the surface of 45S5 bioglass implants when compared with other test materials. When the bone contact for each material was compared between experimental time points, the Glass-Ceramic 2 (CaO rich) group showed significant difference (p = 0.027) at 4 weeks, but no direct contact at 12 weeks. Histology and backscattered electron photomicrographs showed that modified fluorcanasite glass-ceramic implants had greater osteoconductivity than the parent stoichiometric composition. Of the new materials, fluorcanasite glass-ceramic implants modified by the addition of P(2)O(5) showed the greatest stimulation of new mineralized bone tissue formation adjacent to the implants after 4 and 12 weeks implantation. (C) 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 94A: 760-768, 2010
Resumo:
Aim To evaluate the influence of magnesium-enriched hydroxyapatite (MHA) (SintLife (R)) on bone contour preservation and osseointegration at implants placed immediately into extraction sockets. Material and methods In the mandibular pre-molar region, implants were installed immediately into extraction sockets of six Labrador dogs. MHA was placed at test sites, while the control sites did not receive augmentation materials. Implants were intended to heal in a submerged mode. After 4 months of healing, the animals were sacrificed, and ground sections were obtained for histomorphometric evaluation. Results After 4 months of healing, one control implant was not integrated leaving n=5 test and control implants for evaluation. Both at the test and the control sites, bone resorption occurred. While the most coronal bone-to-implant contact was similar between test and control sites, the alveolar bony crest outline was maintained to a higher degree at the buccal aspect of the test sites (loss: 0.7 mm) compared with the control sites (loss: 1.2 mm), even though this difference did not reach statistical significance. Conclusions The use of MHA to fill the defect around implants placed into the alveolus immediately after tooth extraction did not contribute significantly to the maintenance of the contours of the buccal alveolar bone crest. To cite this article:Caneva M, Botticelli D, Stellini E, Souza SLS, Salata LA, Lang NP. Magnesium-enriched hydroxyapatite at immediate implants: a histomorphometric study in dogs.Clin. Oral Impl. Res. 22, 2011; 512-517doi: 10.1111/j.1600-0501.2010.02040.x.
Resumo:
Background: The aim of this study was to evaluate root coverage of gingival recessions and to compare graft vascularization in smokers and non-smokers. Methods: Thirty subjects, 15 smokers and 15 non-smokers, were selected. Each subject had one Miller Class I or II recession in a non-molar tooth. Clinical measurements of probing depth (PD), relative clinical attachment level (CAL), gingival recession (GR), and width of keratinized tissue (KT) were determined at baseline and 3 and 6 months after surgery. The recessions were treated surgically with a coronally positioned flap associated with a subepithelial connective tissue graft. A small portion of this graft was prepared for immunohistochemistry. Blood vessels were identified and counted by expression of factor VIII-related antigen-stained endothelial cells. Results: Intragroup analysis showed that after 6 months there a was gain in CAL, a decrease in GR, and an increase in KT for both groups (P<0.05), whereas changes in PD were not statistically significant. Smokers had less root coverage than non-smokers (58.02% +/- 19.75% versus 83.35% +/- 18.53%; P<0.05). Furthermore, the smokers had more GR (1.48 +/- 0.79 mm versus 0.52 +/- 0.60 mm) than the nonsmokers (P<0.05). Histomorphometry of the donor tissue revealed a blood vessel density of 49.01 +/- 11.91 vessels/200x field for non-smokers and 36.53 +/- 10.23 vessels/200x field for smokers (P<0.05). Conclusion: Root coverage with subepithelial connective tissue graft was negatively affected by smoking, which limited and jeopardized treatment results.
Resumo:
Background: Previous studies have pointed out that the mere elevation of the maxillary sinus membrane promotes bone formation without the use of augmentation materials. Purpose: This experimental study aimed at evaluating if the two-stage procedure for sinus floor augmentation could benefit from the use of a space-making device in order to increase the bone volume to enable later implant installation with good primary stability. Materials and Methods: Six male tufted capuchin primates (Cebus apella) were subjected to extraction of the three premolars and the first molar on both sides of the maxilla to create an edentulous area. The sinuses were opened using the lateral bone-wall window technique, and the membrane was elevated. One resorbable space-making device was inserted in each maxillary sinus, and the bone window was returned in place. The animals were euthanatized after 6 months, and biopsy blocks containing the whole maxillary sinus and surrounding soft tissues were prepared for ground sections. Results: The histological examination of the specimens showed bone formation in contact with both the schneiderian membrane and the device in most cases even when the device was displaced. The process of bone formation indicates that this technique is potentially useful for two-stage sinus floor augmentation. The lack of stabilization of the device within the sinus demands further improvement of space-makers for predictable bone augmentation. Conclusions: It is concluded that (1) the device used in this study did not trigger any important inflammatory reaction; (2) when the sinus membrane was elevated, bone formation was a constant finding; and (3) an ideal space-making device should be stable and elevate the membrane to ensure a maintained connection between the membrane and the secluded space.
Resumo:
Aim To study osseointegration and bone-level changes at implants installed using either a standard or a reduced diameter bur for implant bed preparation. Material and methods In six Labrador dogs, the first and second premolars were extracted bilaterally. Subsequently, mesial roots of the first molars were endodontically treated and distal roots, including the corresponding part of the crown, were extracted. After 3 months of healing, flaps were elevated and recipient sites were prepared in all experimental sites. The control site was prepared using a standard procedure, while the test site was prepared using a drill with a 0.2 mm reduced diameter than the standard one used in the contra-lateral side. After 4 months of healing, the animals were euthanized and biopsies were obtained for histological processing and evaluation. Results With the exception of one implant that was lost, all implants were integrated in mineralized bone. The alveolar crest underwent resorption at control as well as at test sites (buccal aspect similar to 1 mm). The most coronal contact of bone-to-implant was located between 1.2 and 1.6 mm at the test and between 1.3 and 1.7 mm at the control sites. Bone-to-implant contact percentage was between 49% and 67%. No statistically significant differences were found for any of the outcome variables. Conclusions After 4 months of healing, lateral pressure to the implant bed as reflected by higher insertion torques (36 vs. 15 N cm in the premolar and 19 vs. 7 N cm in the molar regions) did not affect the bone-to-implant contact. To cite this article:Pantani F, Botticelli D, Garcia IR Jr., Salata LA, Borges GJ, Lang NP. Influence of lateral pressure to the implant bed on osseointegration: an experimental study in dogs.Clin. Oral Impl. Res. 21, 2010; 1264-1270.doi: 10.1111/j.1600-0501.2009.01941.x.
Resumo:
The purpose of this study was to evaluate ex vivo the accuracy an electronic apex locator during root canal length determination in primary molars. Methods: One calibrated examiner determined the root canal length in 15 primary molars (total=34 root canals) with different stages of root resorption. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using an electronic apex locator (Digital Signal Processing). Data were analyzed statistically using the intraclass correlation (ICC) test. Results: Comparing the actual and electronic root canal length measurements in the primary teeth showed a high correlation (ICC=0.95) Conclusions: The Digital Signal Processing apex locator is useful and accurate for apex foramen location during root canal length measurement in primary molars. (Pediatr Dent 200937:320-2) Received April 75, 2008 vertical bar Lost Revision August 21, 2008 vertical bar Revision Accepted August 22, 2008
Resumo:
Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.
Resumo:
Purpose: The purpose of this study was to evaluate, in vitro, the contamination of toothbrushes and pacifiers by Streptococcus mutans, and the efficacy of microwave and chlorhexidine for their disinfection. Methods: Sixty pacifiers and 60 toothbrushes were contaminated with S mutans and then divided into groups according to the disinfection protocol: Group 1-chlorhexidine solution; Group 2-microwave sterilization; and Group 3-sterile tap water. The devices were evaluated microbiologically as to the formation of S mutans colonies/biofilms and were examined by scanning electron microscopy. The results were submitted for statistical analysis by Friedman`s test at a 5% significance level. Results: The results of both types of evaluation showed a large number of S mutans colonies/biofilms after spraying with sterile tap water, and chlorhexidine spraying and microwaving were effective in eliminate colonies/biofilms. Groups 1 and 2 were statistically similar to each other (P>.05) and differed significantly from Group 3 (P<.05). Conclusions: The 0.12% chlorhexidine solution spray and 7 minutes of microwave irradiation were effective for disinfection of pacifiers and toothbrushes. (Pediatr Dent 2011;33:10-3) Received July 29, 2009 I Last Revision January 26, 2010 I Accepted March 10, 2010
Resumo:
Purpose: This clinical study aimed to evaluate initial, 4-months, and 1-year stability of immediately loaded dental implants inserted according to a protocol of lower rehabilitation with prefabricated bars. Materials and Methods: The sample was composed of 11 edentulous patients. In each patient, 4 interforaminal implants were inserted. Immediately after implant installation, resonance frequency analysis (RFA) for each fixation was registered as well as after 4 months and 1 year with the prosthetic bar removed as it is a screwed system. Results: The clinical implant survival rate was 100%. The RFA showed an increase in stability after 4 months from 64.09 +/- 648 to 64.31 +/- 4.96 and I year, 67.11 +/- 4.37. The analysis of variance showed a statistically significant result (P = 0.015) among implant stability quotient values for the different periods evaluated. Tukey test results showed statistically significant differences between 1-year results and the initial periods but there was no statistically significant difference between initial and 4-month results (P > 0.05). Conclusion: These preliminary 1-year results indicate that immediate loading of mandibular dental implants using the studied prefabricated bars protocol is a reliable treatment as it is in accordance with the results described in the literature for other similar techniques. (Implant Dent 2009; 18:530-538)
Resumo:
Statement of problem. Color stability is an important factor to ensure the long-term clinical success of ceramic restorations. There is a lack of information on how color is affected by fabrication procedures, such as the number of firings. Purpose. The purpose of this study was to evaluate the effects that the number of firings and type of substrate have on the color stability of dental ceramic submitted to artificial accelerated aging. Material and methods. Sixty specimens were fabricated: 30 metal ceramic (Verabond II + IPS d.SIGN) and 30 all-ceramic (IPS d.SIGN). Specimens were divided into 3 groups (n=10), and submitted to 2, 3, or 4 firings (+/- 900 degrees C), respectively, according to the manufacturer`s instructions. Color readings were obtained with a spectro photometer before and after artificial accelerated aging, and L*, a*, and b* coordinates and total color variation (Delta E) were analyzed (2-way ANOVA, Bonferroni, (alpha=05). Results. For metal ceramic specimens, differences for the L* coordinates were significant (P<.05) only for the group submitted to 3 firings. With respect to the all-ceramic specimens, smaller L* coordinates were obtained for greater a* and b* coordinates, indicating that the greater the number of firings, the darker and more reddish/yellowish the specimen. All Delta E values, for all groups, were below 1.0. All-ceramic specimens submitted to 3 and 4 firings presented Delta E means differing statistically (P<.05) from those of the metal ceramic group. Conclusions. The type of substrate and number of firings affected the color stability of the ceramic material tested. Artificial accelerated aging did not produce perceptible color stability changes (Delta E<1.0). (J Prosthet Dent 2009-101:13-18)