167 resultados para Radiology, Medical.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the effects of levonorgestrel-releasing intrauterine devices (LNG-IUD) and a gonadotropin-releasing hormone agonist (GnRHa) on uterine volume, uterine arteries pulsatility index (PI) and endometrial thickness before and after six months of endometriosis treatment. Sixty women aged 18-40 y were allocated randomly to one of two groups: LNG-IUDs were inserted in 30 women, and GnRHa monthly injections were performed on the other 30. All 60 women were submitted to transvaginal 2-D ultrasound scans on the day that the treatment started and then six months later. Measurements of uterine arteries PI, uterine volume and endometrial thickness were performed at both evaluations. The use of LNG-IUDs significantly decreased endometrial thickness (pre = 6.08 +/- 3.00 mm, post = 2.7 +/- 0.98 mm; mean +/- SD), as did the use of GnRHa (pre = 6.96 +/- 3.82 mm, post = 3.23 +/- 2.32 mm). The uterine volume decreased in the GnRHa group (pre = 86.67 +/- 28.38 cm(3), Post = 55.27 +/- 25.52 cm(3)), but not in the LNG-IUD group (pre = 75.77 +/- 20.88 cm(3), post = 75.97 +/- 26.62 cm(3)). Uterine arteries PI increased for both groups; however, the increase was higher in the GnRHa group (0.99 +/- 0.84 vs. 0.38 +/- 0.84, p = 0.007; PI increase in GnRHa and in LNG-IUD groups, respectively). In conclusion, levonorgestrel released directly onto the endometrium by the LNG-IUD induced smaller uterine changes than did the hypoestrogenism induced by GnRHa. Nevertheless, both promoted similar effects on endometrial thickness. (E-mail: wpmartins@gmail.com) (C) 2008 World Federation for Ultrasound in Medicine & Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the crown-rump length (CRL) and the fetal head and trunk (HT) volume between singletons and twins conceived after in vitro fertilization. Thirty pregnant patients submitted to embryo transfer were enrolled in this research. Ten conceived twins (20 dichorionic fetuses) while other 20 conceived singletons. The gestational age was calculated by adding 14 d to the number of days between the oocyte retrieval and the scheduled ultrasound. Three-dimensional ultrasound scans were performed weekly from 73 d (10 wk and 3 d) to 101 d (14 wk and 3 d) of gestational age. HT volume was assessed by VOCAL using 15 degrees step rotation on the manual mode. The measurement of CRL was performed by using the longitudinal plane of the fetus in the multiplanar view. The CRL and HT volume weekly relative increase were evaluated to compare the growth between singletons and twins. No significant difference was identified, in any analyzed week, when comparing the mean of CRL and HT volume between singletons and twins. Additionally, no significant difference between singletons and twins was noticed when comparing the weekly relative increase, both for CRL and HT volume. However, the weekly relative increase was significantly higher for HT volume than for CRL in every week studied for both singletons and twins. The total relative increase observed between 73 and 101 d was much higher for HT volume than for CRL: 679 +/- 39% versus 138 +/- 18% in singletons and 689 +/- 58% versus 139 +/- 21% in twins (HT volume and CRL, respectively), suggesting that HT volume could more accurately determine the gestational age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MRI is an important tool for investigating breast cancer. Although recognized as the method of choice for screening highrisk patients, and for other indications the role of MRI for lesion characterization remains controversial. Recently some authors have advocated the use of morphologic and postcontrast features for this purpose. Quantitative breast MRI techniques have not been applied extensively in breast diseases. Magnetization transfer (MT) is a quantitative MR technique commonly used to investigate neurological diseases. In breast diseases the use of MT has been limited to improving visualization of areas of enhancement in postcontrast images. The purpose of this study was to evaluate the feasibility and utility of MT in discriminating benign from malignant breast lesions. Fifty-two lesions, Bl-RADS 4 and 5, from 49 patients, were prospectively evaluated using the MT ratio (MTR). Patients were divided into two groups: benign and malignant lesions. The MTR of fat, pectoralis major muscle, fibroglandular tissue, and breast lesions were calculated. A statistically significant difference was found between MTR from benign and malignant lesions (P < 0.001). Preliminary results suggest that MT can be used to evaluate breast lesions. Further studies are necessary to better define the utility and applicability of this technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. Endothelial impairment evaluation by sonographic measurement of flow-mediated dilatation (FMD) has become broadly used. However, this method has 2 main caveats: the dilatation depends on the baseline arterial diameter, and a high precision level is required. Vasodilatation leads to an amplified fall in impedance. We hypothesized that assessment of the pulsatility index change (PI-C) 1 minute after 5-minute forearm compression might evaluate that fall in impedance. The aim of this study was to compare the PI-C with FMD. Methods. Flow-mediated dilatation and the PI-C were assessed in 51 healthy women aged between 35.1 and 67.1 years. We correlated both FMD and the PI-C with age, body mass index, waist circumference, cholesterol level, high-density lipoprotein level, glucose level, systolic and diastolic blood pressure, pulse pressure, brachial artery diameter, simplified Framingham score, intima-media thickness, and carotid stiffness index. Intraclass correlation coefficients between 2 FMD and PI-C measurements were also examined. Results. Only FMD correlated with baseline brachial diameter (r=-0.53). The PI-C had a high correlation with age, body mass index, waist circumference, cholesterol level, systolic blood pressure, pulse pressure, simplified Framingham score, and intima-media thickness. The correlation between FMD and the PI-C was high (r=-0.66). The PI-C had a higher intraclass correlation coefficient (0.991) than FMD (0.836) but not brachial artery diameter (0.989). Conclusions. The PI-C had a large correlation with various markers of cardiovascular risk. Additionally, PI-C measurement does not require offline analysis, extra software, or electrocardiography We think that the PI-C could be considered a marker of endothelial function. However, more studies are required before further conclusions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SETTING: Five medical schools in three cities in Rio de Janeiro State, Brazil, with different tuberculosis (TB) incidence rates. OBJECTIVE: To evaluate the prevalence of the booster phenomenon and its associated factors in a voting universally BCG-vaccinated TB-exposed population. DESIGN: A two-step tuberculin skin test (TST) was performed among undergraduate medical students. Boosting was defined as an induration >= 10 mm in the second TST (TST2), with an increase of at least 6 mm over the first TST (TST1). The association of boosting with independent variables was evaluated using multivariate analysis. RESULTS: Of the 764 participants (mean age 21.9 +/- 2.7 years), 672 (87.9%) had a BCG scar. The overall booster SUMMARY phenomenon prevalence was 8.4% (95%CI 6.5-10.6). Boosting was associated with TST1 reactions of 1-9 mm (aOR 2.5, 95%CI 1.04-5.9) and with BCG vaccination, mostly after infancy, i.e., after age two years (aOR 9.1, 95%,CI 1.2-70.7). CONCLUSION: The prevalence of the booster phenomenon was high. A two-step TST in young BCG-vaccinated populations, especially in those with TST1 reactions of 1-9 mm, can avoid misdiagnosis as a false conversion and potentially reduce unnecessary treatment for latent TB infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To describe knowledge, practices, and associated factors of medical students to prevent transmission of tuberculosis (TB) in five medical schools. Methods. Cross-sectional survey of undergraduate medical students in preclinical and in early and late clinical years. Information was obtained on sociodemographic profile, previous lectures on TB, knowledge about TB transmission, exposure to patients with active pulmonary TB, and use of respiratory protective masks. Results. Among 1 094 respondents, 575 (52.6%) correctly answered that coughing, speaking, and sneezing can transmit TB. Early [adjusted odds ratio = 4.0 (3.0, 5.5)] and late [adjusted odds ratio = 4.2 (3.1, 5.8)] clinical years were associated with correct answers, but having had previous lectures on TB was not. Among those who had previous lectures on TB, the rate of correct answers increased from 42.1% to 61.6%. Among 332 medical students who reported exposure to TB patients, 194 (58.4%) had not used protective masks. More years of clinical experience was associated with the use of masks [adjusted odds ratio = 2.9 (1.4, 6.1)], while knowledge was inversely associated with the use of masks [adjusted odds ratio = 0.4 (0.2, 0.6)]. Conclusions. Many medical students are not aware of the main routes of TB infection, and lectures on TB are not sufficient to change knowledge and practices. Regardless of knowledge about TB transmission, students engage in risky behaviors: more than two-thirds do not use a protective mask when examining an active TB case. We suggest innovative, effective active learning experiences to change this scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This literature review retakes the discussion of the profiles and competences of the information area professional, specifically, in the health field. Therefore, the aim here is to outline the new fields of performance for the informationist and the profiles required in the health context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoarthritis (OA) is the most frequent form of arthritis, with major implications for individual and public health care without effective treatment available. The field of joint imaging, and particularly magnetic resonance (MR) imaging, has evolved rapidly owing to technical advances and the application of these to the field of clinical research. Cartilage imaging certainly is at the forefront of these developments. In this review, the different aspects of OA imaging and cartilage assessment, with an emphasis on recent advances, will be presented. The current role of radiography, including advances in the technology for joint space width assessment, will be discussed. The development of various MR imaging techniques capable of facilitating assessment of cartilage morphology and the methods for evaluating the biochemical composition of cartilage will be presented. Advances in quantitative morphologic cartilage assessment and semiquantitative whole-organ assessment will be reviewed. Although MR imaging is the most important modality in imaging of OA and cartilage, others such as ultrasonography play a complementary role that will be discussed briefly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Posterior urethral valves (PUV) are the most common cause of renal impairment in boys during early childhood. Although antenatal suspicion of this pathology has become quite common in recent years, prenatal diagnosis remains challenging. The aim of this study was to evaluate the predictive value of different ultrasound criteria currently used to diagnose PUV. Methods We reviewed the antenatal and postnatal files of 54 male patients referred to our center from 2000 to 2006 after detection of fetal bilateral hydronephrosis. The following ultrasound criteria were evaluated in relation to the postnatal diagnosis of P U V: amniotic fluid volume, bladder wall thickness, bladder dilatation and the presence of the `keyhole sign`. Results Forty-two fetuses (77.8%) were suspected to have PUV on prenatal examination. Out of these, 29 (69.0%) had PUV confirmed postnatally. The sensitivity and specificity of the antenatal diagnosis of PUV were 94% and 43%, respectively. Increased bladder wall thickness and bladder dilatation were highly associated with the diagnosis of PUV (P < 0.001). However, a thick-walled bladder was observed in 39.1% and a dilated bladder in 47.8% of the infants with a postnatal diagnosis other than PUV. The presence of the keyhole sign was not found to predict a diagnosis of PUV (P = 0.27). Conclusion In this series the use of classical prenatal ultrasound signs to diagnose PUV showed high sensitivity but low specificity. The best diagnostic indicators were increased bladder wall thickness and dilatation of the bladder. The keyhole sign was not found to be a reliable predictor of PUV. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To quantitatively evaluate changes induced by the application of a femoral blood-pressure cuff (BPC) on run-off magnetic resonance angiography (MRA). which is a method generally previously proposed to reduce venous contamination in the leg. Materials and Methods: This study was Health Insurance Portability and Accountability Act (HIPAA)- and Institutional Review Board (IRB)-compliant, We used time-resolved gradient-echo gadolinium (Gd)-enhanced MRA to measure BPC effects on arterial, venous, and soft-tissue enhancement. Seven healthy volunteers (six men) were studied with the BPC applied at the mid-femoral level unilaterally using a 1.5T MR system after intravenous injection of Gd-BOPTA. Different statistical tools were used such as the Wilcoxon signed rank test and a cubic smoothing spline fit. Results: We found that BPC application induces delayed venous filling (as previously described), but also induces significant decreases in arterial inflow, arterial enhancement, vascular-soft tissue contrast, and delayed peak enhancement (which have not been previously measured). Conclusion: The potential benefits from using a BPC for run-off MRA must be balanced against the potential pitfalls, elucidated by our findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the reliability of two- and three-dimensional ultrasonographic measurement of the thickness of the lower uterine segment (LUS) in pregnant women by transvaginal and transabdominal approaches. Methods This was a study of 30 pregnant women who bad bad at least one previous Cesarean section and were between 36 and 39 weeks` gestation, with singleton pregnancies in cephalic presentation. Sonographic examinations were performed by two observers using both 4-7-MHz transabdominal and 5-8-MHz transvaginal volumetric probes. LUS measurements were performed using two- and three-dimensional ultrasound, evaluating the entire LUS thickness transabdominally and the LUS muscular thickness transvaginally. Each observer measured the LUS four times by each method. Reliability was analyzed by comparing the mean of the absolute differences, the intraclass correlation coefficients, the 95% limits of agreement and the proportion of differences <1 mm. Results Transvaginal ultrasound provided greater reliability in LUS measurements than did transabdominal ultrasound. The use of three-dimensional ultrasound improved significantly the reliability of the LUS muscular thickness measurement obtained transvaginally. Conclusions Ultrasonographic measurement of the LUS muscular thickness transvaginally appears more reliable than does that of the entire LUS thickness transabdominally. The use of three-dimensional ultrasound should be considered to improve measurement reliability. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semiquantitative assessment of the knee by expert magnetic resonance imaging readers is a powerful research tool for understanding the natural history of osteoarthritis (OA). Several reliable semiquantitative scoring systems have been applied to large observational cross-sectional and longitudinal epidemiologic studies and interventional clinical trials. Such evaluations have enabled understanding of the relevance of disease in structures within the knee joint to explain pain and progression of OA. Compositional imaging of cartilage has added to our ability to detect early degeneration before morphologic changes are present, which may help to prevent the permanent morphologic changes commonly seen in knee OA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The use of Onyx in the treatment of intracranial AVMs has increased the cure rate of endovascular embolization compared with the use of liquid adhesive agents. Inadvertent occlusion of the draining veins before the complete exclusion of the nidus constitutes a major risk of bleeding. We report a case series using the technique of double simultaneous arterial catheterization as an approach to achieve the complete, exclusion of the nidus before reaching the venous drainage, through a more controlled hemodynamic filling. MATERIALS AND METHODS: Between April 2008 and November 2009, 17 patients with brain AVMs were treated by the DACT. The mean age of the patients was 32.7 years (range, 6-54 years), with 9 females and 8 males. The clinical onset was characterized by intracranial hemorrhage in 8 patients and by seizures in 7. The size of the AVMs ranged from 13 to 54 mm (average, 26.2 mm). The DACT was always used with the objective of curing the AVM. RESULTS: All 17 patients completed the EVT. The average number of sessions conducted was 1.4 (range, 1-3 sessions), with the average injection amount of 6.9 mL of Onyx (range, 2-25.2 mL). Sixteen AVMs (94.1%) were angiographically cured by embolization. Clinical complications occurred in 2 patients (11.7%); 1 of these was permanent (5.9%). No deaths were registered. CONCLUSIONS: This preliminary series shows that the DACT presents satisfactory results when used with curative intent.