159 resultados para Optical Imaging
Resumo:
PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716
Resumo:
OBJECTIVES We sought to assess the prognostic value and risk classification improvement using contemporary single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) to predict all-cause mortality. BACKGROUND Myocardial perfusion is a strong estimator of prognosis. Evidence published to date has not established the added prognostic value of SPECT-MPI nor defined an approach to detect improve classification of risk in women from a developing nation. METHODS A total of 2,225 women referred for SPECT-MPI were followed by a mean period of 3.7 +/- 1.4 years. SPECT-MPI results were classified as abnormal on the presence of any perfusion defect. Abnormal scans were further classified as with mild/moderate reversible, severe reversible, partial reversible, or fixed perfusion defects. Risk estimates for incident mortality were categorized as <1%/year, 1% to 2%/year, and >2%/year using Cox proportional hazard models. Risk-adjusted models incorporated clinical risk factors, left ventricular ejection fraction (LVEF), and perfusion variables. RESULTS All-cause death occurred in 139 patients. SPECT-MPI significantly risk stratified the population; patients with abnormal scans had significantly higher death rates compared with patients with normal scans, 13.1% versus 4.0%, respectively (p < 0.001). Cox analysis demonstrated that after adjusting for clinical risk factors and LVEF, SPECT-MPI improved the model discrimination (integrated discrimination index = 0.009; p = 0.02), added significant incremental prognostic information (global chi-square increased from 87.7 to 127.1; p < 0.0001), and improved risk prediction (net reclassification improvement = 0.12; p = 0.005). CONCLUSIONS SPECT-MPI added significant incremental prognostic information to clinical and left ventricular functional variables while enhancing the ability to classify this Brazilian female population into low-and high-risk categories of all-cause mortality. (J Am Coll Cardiol Img 2011;4:880-8) (C) 2011 by the American College of Cardiology Foundation
Resumo:
Carotid artery stenosis due to arteriosclerosis increases the risk of cerebral ischemia via embolic phenomena or reduced blood flow. The changes in cerebral perfusion that may occur after treatment are not clearly understood. This study evaluated the changes in cerebral microcirculation following carotid angioplasty with stenting (CAS) under cerebral protection with filters using ultrafast gradient echo (GRE) perfusion weighted imaging (PWI) with magnetic resonance imaging (MRI). Prospectively, 21 cervical carotid stenosis patients, mean age 69.95 years, underwent MRI 12 h before and 72 h after CAS. PWI parameters were collected for statistical analysis: cerebral blood volume (CB V), mean transit time (MTT) and time to peak (TTP). Statistical analysis was applied to absolute parameters and to values normalized against those from the contralateral parenchyma. The main finding of this study was improved hemodynamics for the normalized data after CAS, shown by reduced MTT (p<0.001) and TTP (p=0.019) in the territory fed by the middle cerebral artery ipsilateral to the CAS. Absolute data showed increased blood volume in the cerebral hemispheres after CAS, which was more accentuated on the stent side (p=0.016) than the contralateral side (p=0.029). Early improvements in cerebral perfusion, mainly seen in the normalized data, were clearly demonstrated in the timing parameters - TTP & MTT - after CAS.
Resumo:
Endometriosis is a common multifocal gynecologic disease that manifests during the reproductive years, often causing chronic pelvic pain and infertility. It may occur as invasive peritoneal fibrotic nodules and adhesions or as ovarian cysts with hemorrhagic content. Although findings at physical examination may be suggestive, imaging is necessary for definitive diagnosis, patient counseling, and treatment planning. The imaging techniques that are most useful for preoperative disease mapping are transvaginal ultrasonography (US) after bowel preparation, and magnetic resonance (MR) imaging. Initial transvaginal US is a reliable technique for detecting rectosigmoid endometriotic lesions. MR imaging is indicated as a complementary examination in complex cases of endometriosis with extensive adhesions and ureteral involvement. Peritoneal endometriotic implants are typically hypoechoic on transvaginal US images and demonstrate low signal intensity on T2-weighted MR images. Endometriotic implants most commonly are found in retrocervical and rectosigmoid sites, followed by the vagina, bladder, and ureters. Cysts with low-level internal echoes and echogenic peripheral foci at transvaginal US are suggestive of endometriomas. MR imaging has high specificity for identifying endometriomas, which are characterized by high signal intensity on T1-weighted images and low signal intensity on T2-weighted images. Correlation of the radiologic imaging features of endometriotic lesions with their laparoscopic appearances may help improve individual proficiency in the radiologic diagnosis of endometriosis. Supplemental material available at http:// radiographics.rsna.org/lookup/suppl/doi: 10.1148/rg.314105193/-/DC1. (C) RSNA, 2011 radiographics.rsna.org
Resumo:
PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093
Resumo:
Background Chronic aortic valve disease (AVD) is characterized by progressive accumulation of interstitial myocardial fibrosis (MF). However, assessment of MF accumulation has only been possible through histologic analyses of endomyocardial biopsies. We sought to evaluate contrast-enhanced magnetic resonance imaging (ce-MRI) as a noninvasive method to identify the presence of increased MF in patients with severe AVD. Methods Seventy patients scheduled to undergo aortic valve replacement surgery were examined by cine and ce-MRI in a 1.5-T scanner. Cine images were used for the assessment of left ventricular (LV) volumes, mass, and function. Delayed-enhancement images were used to characterize the regions of MF. In addition, histologic analyses of myocardial samples obtained during aortic valve replacement surgery were used for direct quantification of interstitial MF. Ten additional subjects who died of noncardiac causes served as controls for the quantitative histologic analyses. Results Interstitial MF determined by histopathologic analysis was higher in patients with AVID than in controls (2.7% +/- 2.0% vs 0.6% +/- 0.2%, P =.001). When compared with histopathologic results, ce-MRI demonstrated a sensitivity of 74%, a specificity of 81%, and an accuracy of 76% to identify AVD patients with increased interstitial MF There was a significant inverse correlation between interstitial MF and LV ejection fraction (r = -0.67, P <.0001). Accordingly, patients with identifiable focal regions of MF by ce-MRI exhibited worse LV systolic function than those without MF (45% +/- 14% vs 65% +/- 14%, P <.0001). Conclusions Contrast-enhanced MRI allows for the noninvasive detection of focal regions of MF in patients with severe AVD. Moreover, patients with identifiable MF by ce-MRI exhibited worse LV functional parameters. (Am Heart J 2009; 157:361-8.)
Resumo:
Our purpose was to study the determinants of coronary and carotid subclinical atherosclerosis, aortic stiffness and their relation with inflammatory biomarkers in familial hypercholesterolemia (FH) subjects. Furthermore, we evaluated the agreement degree of imaging and inflammatory markers` severity used for coronary heart disease (CHD) prediction. Coronary calcium scores (CCS), carotid intima media thickness (IMT), carotid-femoral pulse wave velocity (PWV), C reactive protein (CRP) and white blood cells count (WBC) were determined in 89 FH patients (39 +/- 14 years, mean LDL-C=279 mg/dl) and in 31 normal subjects (NL). The following values were considered as imaging and biomarkers` severity: CCS > 75th% for age and sex, IMT > 900 mu m, PWV > 12 m/s, and CRP > 3 mg/l. Coronary artery calcification (CAC) prevalence and severity, IMT, PWV and WBC values were higher in FH than in NL (all parameters, p < 0.05). After multivariate analysis, the following variables were considered independent determinants of (1) IMT: systolic blood pressure, 10-year CHD risk by Framingham risk scores (FRS) and apolipoprotein B (r(2)=0.33); (2) PWV: age (r(2)=0.35); (3) CAC as a continuous variable: male gender and LDL-cholesterol year score (LYS) (r(2)=0.32); (4) presence of CAC as dichotomous variable: FRS (p=0.0027) and LYS (p=0.0228). With the exception of a moderate agreement degree between IMT and PWV severity (kappa=0.5) all other markers had only a slight agreement level (kappa < 0.1). In conclusion, clinical parameters poorly explained IMT, CAC and PWV variability in FH subjects. Furthermore, imaging markers and inflammatory biomarkers presented a poor agreement degree of their severity for CHD prediction. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Purpose: The purpose of our study was to compare signal characteristics and image qualities of MR imaging at 3.0 T and 1.5 T in patients with diffuse parenchymal liver disease. Materials and methods: 25 consecutive patients with diffuse parenchymal liver disease underwent abdominal MR imaging at both 3.0 T and 1.5 T within a 6-month interval. A retrospective study was conducted to obtain quantitative and qualitative data from both 3.0 T and 1.5 T MRI. Quantitative image analysis was performed by measuring the signal-to-noise ratios (SNRs) and the contrast-to-noise ratios (CNRs) by the Students t-test. Qualitative image analysis was assessed by grading each sequence on a 3- and 4-point scale, regarding the presence of artifacts and image quality, respectively. Statistical analysis consisted of the Wilcoxon signed-rank test. Results: the mean SNRs and CNRs of the liver parenchyma and the portal vein were significantly higher at 3.0 T than at 1.5 T on portal and equilibrium phases of volumetric interpolated breath-hold examination (VIBE) images (P < 0.05). The mean SNRs were significantly higher at 3.0 T than at 1.5 T on T1-weighted spoiled gradient echo (SGE) images (P < 0.05). However, there were no significantly differences on T2-weighted short-inversion-time inversion recovery (STIR) images. Overall image qualities of the 1.5 T noncontrast T1- and T2-weighted sequences were significantly better than 3.0 T (P < 0.01). In contrast, overall image quality of the 3.0 T post-gadolinium VIBE sequence was significantly better than 1.5 T (P< 0.01). Conclusions: MR imaging of post-gadolinium VIBE sequence at 3.0 T has quantitative and qualitative advantages of evaluating for diffuse parenchymal liver disease. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Purpose: To evaluate the diagnostic image quality of post-gadolinium water excitation-magnetization-prepared rapid gradient-echo (WE-MPRAGE) sequence in abdominal examinations of noncooperative patients at 1.5 Tesla (T) and 3.0T MRI. Materials and Methods: Eighty-nine consecutive patients (48 males and 41 females; mean age +/- standard deviation, 54.6 +/- 16.6 years) who had MRI examinations including postgadolinium WE-MPRAGE were included in the study. Of 89 patients, 33 underwent noncooperative protocol at 1.5T. 10 under-went noncooperative protocol at 3.0T, and 46 underwent cooperative protocol at 3.0T. Postgadolinium WE-MPRAGE, MPRAGE, and three-dimensional gradient-echo sequences of these three different groups were qualitatively evaluated for image quality, extent of artifacts, lesion conspicuity, and homogeneity of fat-attenuation by two reviewers retrospectively, independently, and blindly. The results were compared using Wilcoxon signed rank and Mann-Whitney U tests. Kappa statistics were used to measure the extent of agreement between the reviewers. Results: The average scores indicated that the images were diagnostic for WE-MPRAGE at 1.5T and 3.0T in noncooperative patients. WE-MPRAGE achieved homogenous fat-attenuation in 31/33 (94%) of noncooperative patients at 1.5T and 10/10 (100%) of noncooperative patients at 3.0T. WE-MPRAGE at 3.0T had better results for image quality, extent of artifacts, lesion conspicuity and homogeneity of fat-attenuation compared with WE-MPRAGE at 1.5T. in noncooperative patients (P = 0.0008, 0.0006, 0.0024, and 0.0042: respectively). Kappa statistics varied between 0.76 and 1.00, representing good to excellent agreement. Conclusion: WE-MPRAGE may be used as a T1-weighted postgadolinium fat-attenuated sequence in noncooperative patients, particularly at 3.0T MRI.
Resumo:
Kallmann syndrome (KS), characterized by the association of hypogonadotropic hypogonadism and anosmia, may present many other phenotypic abnormalities, including neurologic features as involuntary movements, called mirror movements (MM). MM etiology probably involves a complex mechanism comprising corticospinal tract abnormal development associated with deficient contralateral motor cortex inhibitory system. In this study, in order to address previous hypotheses concerning MM etiology, we identified and quantified white matter (WM) alterations in 21 KS patients, comparing subjects with and without MM and 16 control subjects, using magnetization transfer ratio (MTR) and T2 relaxometry (R2). Magnetization transfer and 12 double-echo images were acquired in a 1.5 T system. MTR and R2 were calculated pixel by pixel to initially create individual maps, and then, group average maps, co-registered with MNI305 stereotaxic coordinate system. After analysis of selected regions of interest, we demonstrated areas with higher 12 relaxation time and lower MTR values in KS patients, with and without MM, differently involving corticospinal tract projection, frontal lobes and corpus callosum. Higher MTR was observed only in pyramidal decussation when compared in both groups of patients with controls. In conclusion, we demonstrated that patients with KS have altered WM areas, presenting in a different manner in patients with and without MM. These data suggest axonal loss or disorganization involving abnormal pyramidal tracts and other associative/connective areas, relating to the presence or absence of MM. We also found a different pattern of alteration in pyramidal decussation, which can represent the primary area of neuronal disarrangement. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The present study compared two heating methods currently used for antigen retrieval (AR) immunostaining: the microwave oven and the steam cooker. Myosin-V, a molecular motor involved in vesicle transport, was used as a neuronal marker in honeybee Apis mellifera brains fixed in formalin. Overall, the steam cooker showed the most satisfactory AR results. At 100 degrees C, tissue morphology was maintained and revealed epitope recovery, while evaporation of the AR solution was markedly reduced; this is important for stabilizing the sodium citrate molarity of the AR buffer and reducing background effects. Standardization of heat-mediated AR of formalin-fixed and paraffin-embedded tissue sections results in more reliable immunostaining of the honeybee brain.
Resumo:
The current study describes the morphologic macular features in two eyes that developed full-thickness macular holes in the setting of documented vitreofoveal separation. Using third-generation optical coherence tomography, complete vitreofoveal separation associated with the disruption of the inner foveal retina was documented in both cases. Five months after presentation, decreased vision and epiretinal membrane formation associated with development of a full-thickness macular hole were observed in the first patient. In the second patient, a full-thickness macular hole was demonstrated by optical coherence tomography 6 weeks after presentation. These findings suggest that full-thickness macular holes may develop in eyes with vitreofoveal separation. Evidence of the disturbance of the inner foveal architecture on optical coherence tomography indicates the potential role of factors other than anteroposterior or oblique vitreoretinal tractional forces in the genesis of some full-thickness macular holes.
Resumo:
Osteoarthritis (OA) is the most frequent form of arthritis, with major implications for individual and public health care without effective treatment available. The field of joint imaging, and particularly magnetic resonance (MR) imaging, has evolved rapidly owing to technical advances and the application of these to the field of clinical research. Cartilage imaging certainly is at the forefront of these developments. In this review, the different aspects of OA imaging and cartilage assessment, with an emphasis on recent advances, will be presented. The current role of radiography, including advances in the technology for joint space width assessment, will be discussed. The development of various MR imaging techniques capable of facilitating assessment of cartilage morphology and the methods for evaluating the biochemical composition of cartilage will be presented. Advances in quantitative morphologic cartilage assessment and semiquantitative whole-organ assessment will be reviewed. Although MR imaging is the most important modality in imaging of OA and cartilage, others such as ultrasonography play a complementary role that will be discussed briefly.
Resumo:
Knee osteoarthritis (OA) has to be considered a whole joint disease. Magnetic resonance imaging (MRI) allows superior assessment of all joint tissues that may be involved in OA, such as the subchondral bone, synovium, ligaments, and periarticular soft tissues. Reliable MRI-based scoring systems are available to assess and quantify these structures and associated pathology. Cross-sectional and longitudinal evaluation has enabled practitioners to understand their relevance in explaining pain and structural progression.