147 resultados para Dual compressible hybrid quantum secret sharing schemes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of improved microbiological procedures associated with molecular techniques has increased the identification of Candida bloodstream infections, even if the isolation of more than one species by culture methods remains uncommon. We report the cases of two children presenting with severe gastrointestinal disorders and other risk factors that contribute to Candida infections. In the first patient, C. albicans DNA was initially detected by a nested-amplification and C. tropicalis was found later during hospitalization, while blood cultures were persistently negative. In the second child, there was amplification of C. albicans and C. glabrata DNA in the same samples, but blood cultures yielded only C. albicans. Both patients received antifungal therapy but had unfavorable outcomes. These two cases illustrate that PCR was more successful than culture methods in detecting Candida in the bloodstream of high risk children, and was also able to detect the presence of more than one species in the same patient that might impact therapy when the fungi are resistant to azole compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevention and treatment of diseases related to changes in body composition require accurate methods for the measurement of body composition. However, few studies have dealt specifically with the assessment of body composition of undernourished older subjects by different methodologies. To assess the body composition of undernourished older subjects by two different methods, dual energy x-ray absorptiometry (DXA) and bioelectric impedance (BIA), and to compare results with those of an eutrophic group. The study model was cross-sectional; the study was performed at the University Hospital of the School of Medicine of Ribeiro Preto, University of So Paulo, Brazil. Forty-one male volunteers aged 62 to 91 years. The groups were selected on the basis of anamnesis, physical examination and nutritional assessment according to the Mini Nutritional Assessment (MNA) score. Body composition was assessed by DXA and BIA. Body weight, arm and calf circumference, body mass index (BMI), fat free mass (FFM) and fat mass (FM) were significantly lower in the undernourished group as compared to the eutrophic group. There were no significant differences between FFM and FM mean values determined by DXA and BIA in both groups, but the agreement between methods in the undernourished group was less strong. Our results suggest caution when BIA is to be applied in studies including undernourished older subjects. This study does not support BIA as an accurate method for the individual assessment of body composition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims. The use of hemodialysis temporary dual-lumen catheters is often complicated by infections, which may be a significant cause of death among patients with end stage renal disease (ESRD). The aim of this study was to assess the incidence of bacteremia and bacterial colonization related to non-tunneled, non-cuffed, dual-lumen temporary catheters in patients with ESRD submitted to hemodialysis. Methods. This study included 29 patients with ESRD. After catheter implantation, patients were monitored throughout the period of catheter permanence by means of blood samples collected weekly from a peripheral vein. Bacteria were isolated and identified according to CLSI recommendations. When catheters were removed for any reason, their tips were evaluated microbiologically. Results. A total of 194 blood samples from the 29 patients implanted with 55 catheters were analyzed. Of these, 15.5% (30 samples) demonstrated bacterial growth, principally Staphylococcus epidermidis (64.5%). Twenty patients (68.9%) presented at least one positive blood culture during follow-up. The median time for catheter colonization was 18.5 days (95% CI: 16.8-30.3). Of the 55 catheters implanted, 28 (50.9%) showed bacterial colonization, corresponding to 23.4 episodes/1000 catheter/days and 9.2 episodes of bacteremia /1000 catheter/days. Fifteen of 28 catheter tips analyzed showed bacterial growth (53.5%). In 14 of these (93.3%), there was agreement between the isolates from the catheter tip and blood cultures. Of 24 episodes of positive blood cultures from 20 different patients in 17 episodes (70.8%), the patients showed no clinical signs or symptoms of bacteremia. Conclusions. The high incidence of catheter colonization, the correlation between blood and catheter tip cultures, and the occurrence of frequent cases of asymptomatic bacteremia justify the proposal of routine peripheral blood collections to monitor patients undergoing hemodialysis with temporary dual-lumen catheters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrogen Sulfide (H2S) is an endogenous gas involved in several biological functions, including modulation of nociception. However, the mechanisms involved in such modulation are not fully elucidated. The present Study demonstrated that the pretreatment of mice with PAG, a H2S synthesis inhibitor, reduced LPS-induced mechanical paw hypernociception. This inhibition of hypernociception was associated with the prevention of neutrophil recruitment to the plantar tissue. Conversely, PAG had no effect on LPS-induced production of the hypernociceptive cytokines, TNF-alpha, IL-1 beta and CXCL1/KC and on hypernociception induced by PGE(2), a directly acting hypernociceptive mediator. In contrast with the pro-nociceptive role of endogenous H2S. systemic administration of NaHS, a H2S donor, reduced LPS-induced mechanical hypernociception in mice. Moreover, this treatment inhibited mechanical hypernociception induced by PGE(2), suggesting a direct effect of H2S on nociceptive neurons. The antinociceptive mechanism of exogenous H2S depends on K-(ATP)(+) channels since the inhibition of PGE(2) hypernociception by NaHS was prevented by glibenclamide (K-(ATP)(+) channel blocker). Finally, NaHS did not alter the thermal nociceptive threshold in the hot-plate test, confirming that its effect is mainly peripheral. Taken together, these results suggest that H2S has a dual role in inflammatory hypernociception: 1. an endogenous pro-nociceptive effect due to up-regulation of neutrophil migration. and 2. an antinociceptive effect by direct blockade of nociceptor sensitization modulating K-(ATP)(+) channels. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Illegitimate V(D)J-recombination in lymphoid malignancies involves rearrangements in immunoglobulin or T-cell receptor genes, and these rearrangements may play a role in oncogenic events. High frequencies of TRGV-BJ hybrid gene (rearrangement between the TRB and TRG loci at 7q35 and 7p14-15, respectively) have been detected in lymphocytes from patients with ataxia telangiectasia (AT), and also in patients with lymphoid malignancies. Although the TRGV-BJ gene has been described only in T-lymphocytes, we previously detected the presence of TRGV-BJ hybrid gene in the genomic DNA extracted from SV40-transformed AT5BIVA fibroblasts from an AT patient. Aiming to determine whether the AT phenotype or the SV40 transformation could be responsible for the production of the hybrid gene by illegitimate V(D)J-recombination, DNA samples were extracted from primary and SV40-transformed (normal and AT) cell lines, following Nested-PCR with TRGV- and TRBJ-specific primers. The hybrid gene was only detected in SV40-transformed fibroblasts (AT-5BIVA and MRC-5). Sequence alignment of the cloned PCR products using the BLAST program confirmed that the fragments corresponded to the TRGV-BJ hybrid gene. The present results indicate that the rearrangement can be produced in nonlymphoid cells, probably as a consequence of the genomic instability caused by the SV40-transformation, and independently of ATM gene mutation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we consider solutions to the three-dimensional Schrodinger equation of the form psi(r) = u(r)/r, where u(0) not equal 0. The expectation value of the kinetic energy operator for such wavefunctions diverges. We show that it is possible to introduce a potential energy with an expectation value that also diverges, exactly cancelling the kinetic energy divergence. This renormalization procedure produces a self-adjoint Hamiltonian. We solve some problems with this new Hamiltonian to illustrate its usefulness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The effects of short-term 5-day and long-term 30-day hyperprolactinemia induced by domperidone (1.7 mg/kg/day, s.c.) or ectopic pituitary graft on the acute inflammatory response induced by carrageenan were evaluated in male rats. Both models of hyperprolactinemia effectively increased serum prolactin (PRL) levels. Methods: The volume in milliliters of inflammatory edema was measured by plethysnnography 1, 2, 3, 4, 6, 8 and 24 h after carrageenan injection. The areas under the inflammatory time-response curves were compared. Additionally, the effects of hyperprolactinemia on body weight and serum corticosterone levels were evaluated. Results: In both domperidone-treated and pituitary graft-implanted animals, short-term 5-day hyperprolactinemia increased the inflammatory response, while long-term 30-day hyperprolactinemia had anti-inflammatory effects. Body weight was not affected by either short- or long-term hyperprolactinennia. Conclusion: These results show that PRL has biphasic effects on the carrageenan-induced inflammatory response. Copyright (C) 2011 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study aimed to determine whether the micro-hardness of a composite resin is modified by the light units or by the thickness of the increment. Composite resin disks were divided into 15 groups (n = 5), according to the factors under study: composite resin thickness (0 mm, 1 mm, 2 mm , 3 mm and 4 mm) and light units. The light activation was performed with halogen light (HL) (40 s, 500 mW/cm(2)), argon ion laser (AL) (30 s, 600 mW/cm(2)) or light-emitting diode (LED) (30 s, 400 mW/cm(2)). Vickers micro-hardness tests were performed after 1 week and were carried out on the top surface (0 mm-control) and at different depths of the samples. Analysis of variance (ANOVA) and Tukey tests (P a parts per thousand currency signaEuro parts per thousand 0.05) revealed no statistically significant difference among the light units for the groups of 0 mm and 1 mm thickness. At 2 mm depth, the AL was not statistically different from the HL, but the latter showed higher micro-hardness values than the LED. In groups with 3 mm and 4 mm thickness, the HL also showed higher micro-hardness values than the groups activated by the AL and the LED. Only the HL presented satisfactory polymerization with 3 mm of thickness. With a 4 mm increment no light unit was able to promote satisfactory polymerization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to evaluate the microtensile bond strength (mu TBS) and hybrid layer morphology of different adhesive systems, either followed by treatment with Nd:YAG laser irradiation or not. Previous studies have shown the effects of Nd:YAG laser irradiation on the dentin surface at restoration margins, but there are few reports about the significance of the irradiation on the hybrid layer. Materials and Methods: The flattened coronal and root dentin samples of 24 bovine teeth were randomly divided into 8 groups, according to the adhesive system used - Scotchbond Multi Purpose (SBMP) or Clearfil SE Bond (CSEB) - and were either irradiated with Nd:YAG or not, with different parameters: 0.8 W/10 Hz, 0.8 W/20 Hz, 1.2 W/10 Hz, 1.2 W/20 Hz. The left sides of specimens were the control groups, and right sides were irradiated. A composite crown was built over bonded surfaces and stored in water (24 h at 37 degrees C). Specimens were sectioned vertically into slabs that were subjected to mu TBS testing and observed by SEM. Results: Control groups (27.81 +/- 1.38) showed statistically higher values than lased groups (21.37 +/- 0.99), and CSEB control group values (31.26 +/- 15.71) were statistically higher than those of SBMP (24.3 +/- 10.66). There were no significant differences between CSEB (20.34 +/- 10.01) and SBMP (22.43 +/- 9.82) lased groups. Among parameters tested, 0.8 W/10 Hz showed the highest value (25.54 +/- 11.74). Nd:YAG laser irradiation caused dentin to melt under the adhesive layer of both adhesive systems tested. Conclusion: With the parameters used in this study, Nd:YAG laser irradiation of the hybrid layer promoted morphological changes in dentin and negatively influenced the bond strength of both adhesive systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In many adult tissues, mesenchymal stem cells (MSCs) are closely associated with perivascular niches and coexpress many markers in common with pericytes. The ability of pericytes to act as MSCs, however, remains controversial. By using genetic lineage tracing, we show that some pericytes differentiate into specialized tooth mesenchyme-derived cells-odontoblasts-during tooth growth and in response to damage in vivo. As the pericyte-derived mesenchymal cell contribution to odontoblast differentiation does not account for all cell differentiation, we identify an additional source of cells with MSC-like properties that are stimulated to migrate toward areas of tissue damage and differentiate into odontoblasts. Thus, although pericytes are capable of acting as a source of MSCs and differentiating into cells of mesenchymal origin, they do so alongside other MSCs of a nonpericyte origin. This study identifies a dual origin of MSCs in a single tissue and suggests that the pericyte contribution to MSC-derived mesenchymal cells in any given tissue is variable and possibly dependent on the extent of the vascularity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The purpose of this study was to evaluate how curing protocol affects the extent of polymerization of dual-cured resin cements. Methods. Four commercial resin cements were used (DuoLink, Panavia F 2.0, Variolink II and Enforce). The extent of polymerization of the resin cements cured under different conditions was measured using a (1)H Stray-Field MRI method, which also enabled to probe molecular mobility in the kHz frequency range. Results. Resin cements show well distinct behaviours concerning chemical cure. Immediate photo-activation appears to be the best choice for higher filler loaded resin cements (Panavia F 2.0 and Variolink). A photo-activation delay (5 min) did not induce any significant difference in the extent of polymerization of all cements. Significance. The extent of polymerization of dual-cured resin cements considerably changed among products under various curing protocols. Clinicians should optimize the materials choice taking into account the curing characteristics of the cements. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the biomechanical fixation, bone-to-implant contact (BIC), and bone morphology of screw-type root-form implants with healing chambers with as-machined or dual acid-etched (DAE) surfaces in a canine model. Materials and Methods: The animal model included the placement of machined (n = 24) and DAE (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Following euthanasia, half of the specimens were subjected to biomechanical testing (torque to interface failure) and the other half were processed for histomorphologic and histomorphometric (%BIC) assessments. Statistical analyses were performed by one-way analysis of variance at the 95% confidence level and the Tukey post hoc test for multiple comparisons. Results: At 4 weeks, the DAE surface presented significantly higher mean values for torque to interface failure overall. A significant increase in %BIC values occurred for both groups over time. For both groups, bone formation through the classic appositional healing pathway was observed in regions where intimate contact between the implant and the osteotomy walls occurred immediately after implantation. Where contact-free spaces existed after implantation (healing chambers), an intramembranous-like healing mode with newly formed woven bone prevailed. Conclusions: In the present short-term evaluation, no differences were observed in BIC between groups; however, an increase in biomechanical fixation was seen from 2 to 4 weeks with the DAE surface. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:75-82