159 resultados para Data reliability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To compare pelvic floor muscle (PFM) strength between women undergoing vaginal delivery, cesarean section, and nulliparae, investigating the factors associated with PFM strength, and observing the correlation between vaginal digital palpation and use of a perineometer. Methods. A cross-sectional study was conducted, including 31 women following vaginal delivery, 30 women following cesarean section, and 30 nulliparous women. PFM strength was measured by vaginal digital palpation and use of a perineometer. Multiple linear regression analysis with adjustment for covariables was used to compare the mean PFM strength and identify its associated factors. Results. The mean PFM strength of women undergoing vaginal delivery and cesarean section was 25.6 +/- 14.5 cmH(2)O and 39.6 +/- 22.0 cmH(2)O (p < 0.01, adjusted for covariables), respectively. A correlation was observed between measurements of PFM strength obtained by vaginal digital palpation and use of a perineometer (tau = 0.82; p < 0.01). The non-white race/ethnicity was negatively associated with PFM strength (coefficient: -10.2424; p = 0.02). Conclusions. A lower PFM strength was observed in women with a history of vaginal delivery compared to those undergoing cesarean section. Non-white race/ethnicity negatively affected PFM strength. Our data suggest that vaginal digital palpation may be used in clinical practice because of its expressive correlation with use of a perineometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Historically, the cure rate model has been used for modeling time-to-event data within which a significant proportion of patients are assumed to be cured of illnesses, including breast cancer, non-Hodgkin lymphoma, leukemia, prostate cancer, melanoma, and head and neck cancer. Perhaps the most popular type of cure rate model is the mixture model introduced by Berkson and Gage [1]. In this model, it is assumed that a certain proportion of the patients are cured, in the sense that they do not present the event of interest during a long period of time and can found to be immune to the cause of failure under study. In this paper, we propose a general hazard model which accommodates comprehensive families of cure rate models as particular cases, including the model proposed by Berkson and Gage. The maximum-likelihood-estimation procedure is discussed. A simulation study analyzes the coverage probabilities of the asymptotic confidence intervals for the parameters. A real data set on children exposed to HIV by vertical transmission illustrates the methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the intra-and inter-rater reliability of pressure pain threshold (PPT) and manual palpation (MP) of orofacial structures in symptomatic and symptom-free children for temporomandibular disorders (TMD). Fourteen children reporting pain in masticatory muscles or the temporomandibular joint and 16 symptom-free children were randomly assessed on three different occasions: by rater-1 in the first and third session and by rater-2 in the second session. The trained raters applied algometry and MP as recommended by the Research Diagnostic Criteria for TMD. Intraclass correlation coefficients and the Kappa statistic were used to assess the levels of reliability of PPT and MP, respectively. Excellent intra-and inter-rater reliability levels were observed for PPT values at most of the examined sites for symptom-free children and excellent and moderate reliability levels for children reporting pain. For MP, moderate and poor intra-rater and inter-rater reliability levels were observed for most sites in both groups. Algometry showed higher reliability levels for both groups of children and is recommended for pain assessment in children in association with MP. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To perform a psychometric analysis of the Brazilian version of the Brief Social Phobia Scale (BSPS). Materials and methods: Hundred and seventy-eight university students of both genders aged on average 21.2 years and identified as Social Anxiety Disorder (SAD) cases and non-cases was studied, with the structured clinical interview for DSM-IV being used as a parameter. The different instruments were applied in an individual manner in the presence of a rater and of an observer. Results: The BSPS showed adequate internal consistency (0.48-0.88) and concurrent and divergent validity with the Beck Anxiety Inventory (BAI) (0.21-0.62), Social Phobia Inventory (0.24-0.82) and Self Statements During Public Speaking Scale (SSPS) (0.23-0.31). Discriminative validity revealed a sensitivity of 0.88-0.90 and a specificity of 0.81(0.83 for cut-off notes of 18/19. Factorial analysis demonstrated the presence of six factors that jointly explained 71.79% of data variance. Construct validity indicated some limits of the scale regarding the diagnosis of SAD. Inter-rater reliability was strong (0.86-1.00, p < 0.001). Conclusions: The BSPS is adequate for use with university students, although further studies in different cultures, samples and contexts are still necessary. (C) 2009 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pharmacological profile of cannabidiol (CBD) has several characteristics in common with drugs known to benefit bipolar affective disorder (BAD), leading to the hypothesis that CBD may have therapeutic properties in BAD. Therefore, the aim of the present report was to directly investigate for the first time the efficacy and safety of CBD in two patients with BAD. Both patients met DSM IV criteria for bipolar I disorder experiencing a manic episode without comorbid conditions. This was an inpatient study, and the efficacy, tolerability and side effects were assessed. Both patients received placebo for the initial 5 days and CBD from the 6th to 30th day (initial oral dose of 600 mg reaching 1200 mg/day). From the 6th to the 20th day, the first patient (a 34-year-old woman) received adjunctive olanzapine (oral dose of 10-15 mg). On day 31, CBD treatment was discontinued and replaced by placebo for 5 days. The first patient showed symptoms improvement while on olanzapine plus CBD, but showed no additional improvement during CBD monotherapy. The second patient (a 36-year-old woman) had no symptoms improvement with any dose of CBD during the trial. Both patients tolerated CBD very well and no side-effects were reported. These preliminary data suggest that CBD may not be effective for the manic episode of BAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Play is an indication of a children`s development. Purpose. Organize a culturally adapt the Child-Initiated Pretend Play Assessment to Brazilian population. Method. Translation and cultural adaptation procedures consisted of translation, synthesis, back translation, author`s approval, and pretest of the assessment. For the pretest, 14 typically developing children were assessed. Was evaluated the use of play materials, duration of the assessment, and reliability. Findings. Play materials and duration of the assessment were appropriate for Brazilian children. Analysis of intra-rater reliability showed good agreement ranging from 0.90 to 1.00. Inter-rater reliability showed good to moderate agreement for five items ranging from 0.76 to 0.59. Four items showed chance to poor agreement (rho = -0.13 to 0.50). Implications. Results of the pretest indicate the Brazilian version of the ChIPPA is potentially useful for Brazilian children. ChIPPA training in Portuguese in Brazil with play observation feedback is recommended to improve inter-rater reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Clinical evaluation of the stomatognathic system is indispensable for the diagnosis of orofacial myofunctional disorders. In order to obtain a more precise diagnosis, the protocol of orofacial myofunctional evaluation with scores (OMES protocol) (Int. J. Pediatr. Otorhinolaryngol. 72 (2008) 367-375) was expanded in terms of number of items and scale amplitude. The proposal of this study is to describe the expanded OMES protocol (OMES-E) for the evaluation of children. Validity of the protocol, reliability of the examiners and agreement between them were analyzed, as also were the sensitivity, specificity and predictive values of the instrument. Methods: The sample consisted of videorecorded images of 50 children, 25 boys (mean age = 8.4 years, SD = 1.8) and 25 girls (mean age = 8.2 years, SD = 1.7) selected at random from 200 samples. Three speech therapists prepared for orofacial myofunctional evaluation participated as examiners (E). The OMES and OMES-E protocols were used for evaluation on different days. E1 evaluated all images, E2 analyzed children with recordings from 1 to 25 and E3 analyzed children with recordings from 26 to 50. The validity of OMES-E was analyzed by comparing the instrument to the OMES protocol using the Pearson correlation test complemented with the split-half reliability test (p < 0.05). The linear weighted Kappa coefficient of agreement (Kw`), the sensitivity, specificity and predictive values and the prevalence of OMD were calculated. Results: There was a statistically significant correlation between the OMES and OMES-E protocols (0.79 > r < 0.94, p < 0.01) and a significant test-retest correlation with the OMES-E (0.75 > r < 0.86, p < 0.01), with a reliability range of 0.86-0.93. The correlation and reliability coefficients between examiners were: E1 x E2 (r = 0.74, 0.84), E1 x E3 (r = 0.70, 0.83) (p < 0.01). Kw` coefficients with moderate and good strength predominated. The OMES-E protocol presented mean sensitivity = 0.91, specificity = 0.77, positive predictive value = 0.87 and negative predictive value = 0.85. The mean prevalence of OMD was 0.58. Conclusion: The OMES-E protocol is valid and reliable for orofacial myofunctional evaluation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>The determination of normal parameters is an important procedure in the evaluation of the stomatognathic system. We used the surface electromyography standardization protocol described by Ferrario et al. (J Oral Rehabil. 2000;27:33-40, 2006;33:341) to determine reference values of the electromyographic standardized indices for the assessment of muscular symmetry (left and right side, percentage overlapping coefficient, POC), potential lateral displacing components (unbalanced contractile activities of contralateral masseter and temporalis muscles, TC), relative activity (most prevalent pair of masticatory muscles, ATTIV) and total activity (integrated areas of the electromyographic potentials over time, IMPACT) in healthy Brazilian young adults, and the relevant data reproducibility. Electromyography of the right and left masseter and temporalis muscles was performed during maximum teeth clenching in 20 healthy subjects (10 women and 10 men, mean age 23 years, s.d. 3), free from periodontal problems, temporomandibular disorders, oro-facial myofunctional disorder, and with full permanent dentition (28 teeth at least). Data reproducibility was computed for 75% of the sample. The values obtained were POC Temporal (88 center dot 11 +/- 1 center dot 45%), POC masseter (87 center dot 11 +/- 1 center dot 60%), TC (8 center dot 79 +/- 1 center dot 20%), ATTIV (-0 center dot 33 +/- 9 center dot 65%) and IMPACT (110 center dot 40 +/- 23 center dot 69 mu V/mu V center dot s %). There were no statistical differences between test and retest values (P > 0 center dot 05). The Technical Errors of Measurement (TEM) for 50% of subjects assessed during the same session were 1 center dot 5, 1 center dot 39, 1 center dot 06, 3 center dot 83 and 10 center dot 04. For 25% of the subjects assessed after a 6-month interval, the TEM were 0 center dot 80, 1 center dot 03, 0 center dot 73, 12 center dot 70 and 19 center dot 10. For all indices, there was good reproducibility. These electromyographic indices could be used in the assessment of patients with stomatognathic dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quality of life (QOL) has been extensively studied in clinical trials and in research on chronic degenerative diseases and dementia. The aim of this study was to assess the reliability and construct validity of the Brazilian version of the QOL scale in Alzheimer`s disease (AD; QOL-AD). The QOL-AD was administered to 60 patients with mild or moderate AD and to their caregivers. The construct validation was accomplished through correlations amongst total scores of patients` and caregivers` reports on patients` quality of life (PQOL and C-PQOL, respectively), and data related to cognitive impairment, depressive symptoms, functional performance, behavioral disturbances and a generic instrument of quality of life (WHOQOL-brief), as well as correlation of total score of caregivers` reports on their own quality of life (CQOL) with the measurements cited above, QOL-AD patient reports, and depressive symptoms. The reliability was high for PQOL, C-PQOL, and CQOL versions (Cronbach`s alpha = 0.80, 0.83, and 0.86, respectively). We observed significant correlations in the construct validity of all three versions regarding the variables associated with the disease and also with WHOQOL-brief. The scale took, on average, six min for each version. The results indicate reliability and construct validity of the Brazilian version of the QOL-AD in the studied sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the reliability of two- and three-dimensional ultrasonographic measurement of the thickness of the lower uterine segment (LUS) in pregnant women by transvaginal and transabdominal approaches. Methods This was a study of 30 pregnant women who bad bad at least one previous Cesarean section and were between 36 and 39 weeks` gestation, with singleton pregnancies in cephalic presentation. Sonographic examinations were performed by two observers using both 4-7-MHz transabdominal and 5-8-MHz transvaginal volumetric probes. LUS measurements were performed using two- and three-dimensional ultrasound, evaluating the entire LUS thickness transabdominally and the LUS muscular thickness transvaginally. Each observer measured the LUS four times by each method. Reliability was analyzed by comparing the mean of the absolute differences, the intraclass correlation coefficients, the 95% limits of agreement and the proportion of differences <1 mm. Results Transvaginal ultrasound provided greater reliability in LUS measurements than did transabdominal ultrasound. The use of three-dimensional ultrasound improved significantly the reliability of the LUS muscular thickness measurement obtained transvaginally. Conclusions Ultrasonographic measurement of the LUS muscular thickness transvaginally appears more reliable than does that of the entire LUS thickness transabdominally. The use of three-dimensional ultrasound should be considered to improve measurement reliability. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the inter-rater reliability of the modified Oxford Grading Scale and the Peritron manometer. Design All participants were evaluated twice, first by one examiner and 30 days later by a second examiner. Measurements of vaginal squeeze pressure were compared with the results from the palpation test. Participants Nineteen women with a mean age of 23.7 years (range 21 to 28 years). Results Inter-rater reliability for vaginal palpation was fair (kappa = 0.33, 95% confidence interval 0.09 to 0.57). Using the Peritron manometer, the difference between examiners was less than 10 cmH(2)O in 11 of the 19 (58%) cases. The palpation test did not differentiate between weak, moderate, good and strong muscle contractions. This study found fair inter-rater reliability for the modified Oxford Grading Scale and moderate inter-rater reliability for the Peritron manometer. Conclusions The inter-rater reliability of vaginal squeeze pressure measurement using the Peritron manometer is acceptable and can be used in re-evaluations performed by different examiners in clinical practice. However, for research purposes, the ideal situation would be for a single examiner to assess and re-assess the subject. Vaginal palpation is important in the clinical assessment of correctness of a pelvic floor muscle contraction, but this study does not support the use of the modified Oxford Grading Scale as a reliable and valid method to measure and differentiate pelvic floor muscle strength. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Comparative genomic hybridization (CGH) is a valuable alternative to fluorescence in situ hybridization (FISH) for preimplantation genetic screening (PGS) because it allows full karyotype analysis. However, this approach requires the cryopreservation of biopsied embryos until results are available. The aim of this study is to reduce the hybridization period of CGH, in order to make this short-CGH technique suitable for PGS of Day-3 embryos, avoiding the cryopreservation step. METHODS: Thirty-two fibroblasts from six aneuploid cell lines (Coriell) and 48 blastomeres from 10 Day-4 embryos, discarded after PGS by FISH with 9 probes (9-chr-FISH), were analysed by short-CGH. A reanalysis by the standard 72 h-CGH and FISH using telomeric probes was performed when no concordant results between short-CGH and FISH diagnosis were observed. The short-CGH was subsequently applied in a clinical case of advanced maternal age. RESULTS: In 100% of the fibroblasts analysed, the characteristic aneuploidies of each cell line were detected by short-CGH. The results of the 48 blastomeres screened by short-CGH were supported by both 72 h-CGH results and FISH reanalysis. The chromosomes most frequently involved in aneuploidy were 22 and 16, but aneuploidies for the other chromosomes, excepting 1, 10 and 13, were also detected. Forty-one of the 94 aneuploid events observed (43.6%) corresponded to chromosomes which are not analysed by 9-chr-FISH. CONCLUSIONS: We have performed a preliminary validation of the short-CGH technique, including one clinical case, suggesting this approach may be applied to Day-3 aneuploidy analysis, thereby avoiding embryo cryopreservation and perhaps helping to improve implantation rate after PGS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To determine the slow crack growth (SCG) and Weibull parameters of five dental ceramics: a vitreous porcelain (V), a leucite-based porcelain (D), a leucite-based glass-ceramic (E1), a lithium disilicate glass-ceramic (E2) and a glass-infiltrated alumina composite (IC). Methods. Eighty disks (empty set 12mm x 1.1mm thick) of each material were constructed according to manufacturers` recommendations and polished. The stress corrosion susceptibility coefficient (n) was obtained by dynamic fatigue test, and specimens were tested in biaxial flexure at five stress rates immersed in artificial saliva at 37 degrees C. Weibull parameters were calculated for the 30 specimens tested at 1MPa/s in artificial saliva at 37 degrees C. The 80 specimens were distributed as follows: 10 for each stress rate (10(-2), 10(-1), 10(1), 10(2) MPa/s), 10 for inert strength (10(2) MPa/s, silicon oil) and 30 for 10(0) MPa/s. Fractographic analysis was also performed to investigate the fracture origin. Results. E2 showed the lowest slow crack growth susceptibility coefficient (17.2), followed by D (20.4) and V (26.3). E1 and IC presented the highest n values (30.1 and 31.1, respectively). Porcelain V presented the lowest Weibull modulus (5.2). All other materials showed similar Weibull modulus values, ranging from 9.4 to 11.7. Fractographic analysis indicated that for porcelain D, glass-ceramics E1 and E2, and composite IC crack deflection was the main toughening mechanism. Significance. This study provides a detailed microstructural and slow crack growth characterization of widely used dental ceramics. This is important from a clinical standpoint to assist the clinician in choosing the best ceramic material for each situation as well as predicting its clinical longevity. It also can be helpful in developing new materials for dental prostheses. (c) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.