133 resultados para Intravenous self-administration


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Iron supplementation in hemodialysis patients is fundamental to erythropoiesis, but may cause harmful effects. We measured oxidative stress using labile plasma iron (LPI) after parenteral iron replacement in chronic hemodialysis patients. Intravenous iron saccharate (100 mg) was administered in patients undergoing chronic hemodialysis (N = 20). LPI was measured by an oxidant-sensitive fluorescent probe at the beginning of dialysis session (T0), at 10 min (T1), 20 min (T2), and 30 min (T3) after the infusion of iron and at the subsequent session; P < 0.05 was significant. The LPI values were significantly raised according to the time of administration and were transitory: -0.02 +/- 0.20 mu mol/L at the beginning of the first session, 0.01 +/- 0.26 mu mol/L at T0, 0.03 +/- 0.23 mu mol/L at T1, 0.09 +/- 0.28 mmol/L at T2, 0.18 +/- 0.52 mmol/L at T3, and -0.02 +/- 0.16 mmol/L (P = 0.001 to 0.041) at the beginning of the second session. The LPI level in patients without iron supplementation was -0.06 +/- 0.16 mmol/L. Correlations of LPI according to time were T1, T2, and T3 vs. serum iron (P = 0.01, P = 0.007, and P = 0.0025, respectively), and T2 and T3 vs. transferrin saturation (P = 0.001 and P = 0.0003, respectively). LPI generation after intravenous saccharate administration is time-dependent and transitorily detected during hemodialysis. The LPI increment had a positive correlation to iron and transferrin saturation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Low to moderate doses of alcohol consumption induce heightened aggressive behavior in some, but not all individuals. Individual vulnerability for this nonadaptive behavior may be determined by an interaction of genetic and environmental factors with the sensitivity of alcohol`s effects on brain and behavior. We used a previously established protocol for alcohol oral self-administration and characterized alcohol-heightened aggressive (AHA) mice as compared with alcohol non-heightened (ANA) counterparts. A week later, we quantified mRNA steady state levels of several candidate genes in the serotonin [5-hydroxytryptamine (5-HT)] system in different brain areas. We report a regionally selective and significant reduction of all 5-HT receptor subtype transcripts, except for 5-HT(3), in the prefrontal cortex of AHA mice. Comparable gene expression profile was previously observed in aggressive mice induced by social isolation or by an anabolic androgenic steroid. Additional change in the 5-HT(1B) receptor transcripts was seen in the amygdala and hypothalamus of AHA mice. In both these areas, 5-HT(1B) mRNA was elevated when compared with ANA mice. In the hypothalamus, AHA mice also showed increased transcripts for 5-HT(2A) receptor. In the midbrain, 5-HT synthetic enzyme, 5-HT transporter and 5-HT receptors mRNA levels were similar between groups. Our results emphasize a role for postsynaptic over presynaptic 5-HT receptors in mice which showed escalated aggression after the consumption of a moderate dose of alcohol. This gene expression profile of 5-HT neurotransmission components in the brain of mice may suggest a vulnerability trait for alcohol-heightened aggression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to compare the pharmacokinetics of tetracycline in plasma, synovial fluid, and milk following either a single systemic intravenous (i.v.) injection or a single i.v. regional antibiosis (IVRA) administration of tetracycline hydrochloride to dairy cattle with papillomatous digital dermatitis (PDD). To this end, plasma and synovial fluid tetracycline concentrations were compared with the minimal inhibitory concentration (MIC) values of the major bacteria, which are known to cause digital diseases and thus assess its efficacy in PDD. Residual tetracycline concentrations in milk from cows treated by both methods were also determined. Twelve Holstein cows with various stages of PDD were randomly assigned to two groups of six animals. Group 1 received a single systemic i.v. injection of 10 mg/kg of tetracycline hydrochloride. Group 2 received 1000 mg of tetracycline hydrochloride by IVRA of the affected limb. Blood, synovial fluid and milk samples were taken prior to tetracycline administration (time 0 control), and then at 22, 45 and 82 min, and 2, 3, 4, 6, 8, 12, 24, 48, 72, 96, and 120 h following drug administration. Tetracycline concentrations were determined by high-performance liquid chromatography. Mean tetracycline plasma and milk concentrations in Group 1 were higher than Group 2. The opposite was observed for synovial fluid concentrations. Group 2 synovial fluid concentrations were higher than the MIC value over 24 h for the bacteria most frequently responsible for claw disease. Compared with i.v. administration, IVRA administration of tetracycline produced very high synovial fluid and low plasma and milk concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We studied the levels of immunoglobulins in colostrum, milk and sera from two common variable immunodeficiency (CVID) mothers (M1 and M2), and in sera from their newborn infants. During pregnancy they continued intravenous immunoglobulin therapy (IVIG). Antibody levels from maternal and cord blood collected at delivery and colostrum and milk, collected on the 3rd and 7th post-partum days, respectively, were analyzed. Although cord/maternal blood ratios of total immunoglobulins and subclasses, as well as specific antibodies differed between M1 and M2, both showed good placental transfer of anti-protein and anti-polysaccharide antibodies, despite lower cord/maternal blood ratios in M2. Anti-Streptococcus pneumoniae antibody avidity indexes were similar between paired maternal and cord serum. Both mothers` colostrum and milk samples showed only traces of IgA, and IgM and IgG levels in colostrum were within normal range in M1, whereas M2 presented elevated IgG and low IgM levels, when compared with healthy mothers. The study of colostrum and milk activity showed that they strongly inhibited enteropathogenic Escherichia coli adhesion in vitro. CVID patients must be informed about the relevance of regular IVIG administration during pregnancy, not only for their own health but also for their immune immature offspring. Breast-feeding should be encouraged as colostra from these CVID patients strongly inhibited E. coli adhesion to human epithelial cells thus providing immunological protection plus nutritional and psychological benefits for the infant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the relationship between malocclusion and self-perception of oral appearance/function, in 12/15-year-old Brazilian adolescents. The cluster sample consisted of 717 teenagers attending 24 urban public (n=611) and 5 rural public (n=107) schools in Maringá/PR. Malocclusion was measured using the Dental Aesthetic Index (DAI), in accordance with WHO recommendations. A parental questionnaire was applied to collect information on esthetic perception level and oral variables related to oral health. Univariate and multiple logistic regression analyses were performed. Multiple logistic regression confirmed that for 12-year-old, missing teeth (OR=2.865) and presence of openbite (open occlusal relationship) (OR=2.865) were risk indicators for speech capability. With regard to 15-year-old, presence of mandibular overjet (horizontal overlap) (OR=4.016) was a risk indicator for speech capability and molar relationship (OR=1.661) was a risk indicator for chewing capability. The impact of malocclusion on adolescents' life was confirmed in this study. Speech and chewing capability were associated with orthodontic deviations, which should be taken into consideration in oral health planning, to identify risk groups and improve community health services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the dentin shear bond strength of four adhesive systems (Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond) in regards to buccal and lingual surfaces and dentin depth. Forty extracted third molars had roots removed and crowns bisected in the mesiodistal direction. The buccal and lingual surfaces were fixed in a PVC/acrylic resin ring and were divided into buccal and lingual groups assigned to each selected adhesive. The same specimens prepared for the evaluation of superficial dentin shear resistance were used to evaluate the different depths of dentin. The specimens were identified and abraded at depths of 0.5, 1.0, 1.5 and 2.0 mm. Each depth was evaluated by ISO TR 11405 using an EMIC-2000 machine regulated at 0.5 mm/min with a 200 Kgf load cell. We performed statistical analyses on the results (ANOVA, Tukey and Scheffé tests). Data revealed statistical differences (p < 0.01) in the adhesive and depth variation as well as adhesive/depth interactions. The Adper Single Bond 2 demonstrated the highest mean values of shear bond strength. The Prompt L-Pop product, a self-etching adhesive, revealed higher mean values compared with Magic Bond DE and Self Etch Bond adhesives, a total and self-etching adhesive respectively. It may be concluded that the shear bond strength of dentin is dependent on material (adhesive system), substrate depth and adhesive/depth interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fisher's test (α=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (±4.29); II-8.57 (±3.19); III-7.97 (±2.16); IV-12.56 (±3.11); V-11.45 (±3.77); and VI-7.47 (±1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical substances used during biomechanical preparation of root canals can alter the composition of dentin surface and affect the interaction with restorative materials. OBJECTIVE: The purpose of this study was to evaluate the microtensile bond strength (µTBS) of a self-etching adhesive system to dentin irrigated with sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA). MATERIAL AND METHODS: Thirty human third molars were sectioned 3 mm below the occlusal surface, polished with 600- to 1200-grit silicon carbide papers, and randomly divided into 3 groups: G1 (control): no irrigating solution; G2: 1% NaOCl; and G3: 1% NaOCl followed by the application of 17% EDTA. The specimens received the self-etching adhesive system (XENO III - Dentsply), restored with microhybrid composite resin (Z250 - 3M ESPE), sectioned and trimmed to create 4 hourglass-shaped slabs of each tooth. The slabs were tested in microtensile strength in a universal testing machine (Emic DL 2000) at a crosshead speed of 0.5 mm/min until fracture. The results were analyzed statistically by ANOVA and Newman-Keuls test. RESULTS: Mean µTBS values and standard deviations in MPa were: G1 = 11.89 ± 4.22; G2 = 19.41 ± 5.32; G3 = 11.34 ± 4.73. 1% NaOCl increased the adhesive resistance significantly (p<0.001/F=22.5763). The application of 1% NaOCl/17% EDTA resulted in statistically similar µTBS to the control group. CONCLUSIONS: None of the irrigants affected negatively the µTBS of XENO III to dentin. The use of 1% NaOCl alone resulted in higher bond strength than the other treatments. The combination of 1% NaOCl and 17% EDTA produced similar bond strength to that of untreated dentin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate the morphology of glass (GF), carbon (CF) and glass/carbon (G/CF) fiber posts and their bond strength to self or dual-cured resin luting agents. MATERIAL AND METHODS: Morphological analysis of each post type was conducted under scanning electron microscopy (SEM). Bond strength was evaluated by microtensile test after bisecting the posts and re-bonding the two halves with the luting agents. Data were subjected to two-way ANOVA and Tukey's test (α=0.05). Failure modes were evaluated under optical microscopy and SEM. RESULTS: GF presented wider fibers and higher amount of matrix than CF, and G/CF presented carbon fibers surrounded by glass fibers, and both involved by matrix. For CF and GF, the dual-cured material presented significantly higher (p<0.05) bond strength than the self-cured agent. For the dual agent, CF presented similar bond strength to GF (p>0.05), but higher than that of G/CF (p<0.05). For the self-cured agent, no significant differences (p>0.05) were detected, irrespective of the post type. For GF and G/CF, all failures were considered mixed, while a predominance of adhesive failures was detected for CF. CONCLUSION: The bonding between fiber posts and luting agents was affected by the type of fibers and polymerization mode of the cement. When no surface treatment of the post is performed, the bonding between glass fiber post and dual-cured agent seems to be more reliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because a greater research effort has been directed to analyzing the adhesive effectiveness of self etch primers to dentin, the aim of this study was to evaluate, by microtensile testing, the bond strength to enamel of a composite resin combined with a conventional adhesive system or with a self-etching primer adhesive, used according to its original prescription or used with previous acid etching. Thirty bovine teeth were divided into 3 groups with 10 teeth each (n= 10). In one of the groups, a self-etching primer (Clearfil SE Bond - Kuraray) was applied in accordance with the manufacturer's instructions and, in the other, it was applied after previous acid etching. In the third group, a conventional adhesive system (Scotchbond Multipurpose Plus - 3M-ESPE) was applied in accordance with the manufacturer's instructions. The results obtained by analysis of variance revealed significant differences between the adhesive systems (F = 22.31). The self-etching primer (Clearfil SE Bond) presented lower enamel bond strength values than the conventional adhesive system (Scotchbond Multipurpose Plus) (m = 39.70 ± 7.07 MPa) both when used according to the original prescription (m = 27.81 ± 2.64 MPa) and with previous acid etching (m = 25.08 ± 4.92 MPa).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the tensile bond strength of a self-etching adhesive system to three different dentinal substrates. Primary molar teeth that had been recently exfoliated (RE), with unknown time of exfoliation (UT), and extracted due to prolonged retention (PR) were used for this investigation. Ten primary molar teeth of each group were cut in the middle following the mesio-distal direction, creating a total of twenty specimens per group. The specimens were included in acrylic resin and had a flat dentin surface exposed. The self-etching adhesive system was applied to this surface and a 3-millimeter high cone with diameter of 2 mm in the adhesion area was constructed using composite resin. The specimens were stored in distilled water at 37ºC for 24 hours. Fifteen specimens of each substrate were used for the tensile bond test (n = 15) and 5 had the interface analyzed by scanning electron microscopy (SEM). The data was examined by one-way ANOVA and presented no significant differences between groups (p = 0.5787). The mean values obtained for RE, UT and PR were 18.39 ± 9.70, 19.41 ± 7.80, and 23.30 ± 9.37 MPa, respectively. Any dentinal substrates of primary teeth studied are safe for tensile bond strength tests with adhesive systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the completion rates and performance of the Brazilian version of the Oral Health Impact Profile (OHIP14) when applied as an interview or in its original self-reported form. A convenience sample of 74 adult patients was selected in a Dental Clinic (University of Araras, Brazil). One examiner administered the instrument in both formats to participants with an interval of 2 weeks between each administration. Data about dental health condition and socioeconomic status were collected and associated with total OHIP14 scores in both formats using linear regression analyses. No differences were found in the total scores and in each subscale of the OHIP14 according to the form of administration. Higher values of completion were found in the interview format. More severe impacts were recorded in the interview format than in the questionnaire format. Higher values of total OHIP-14 scores in both formats were related to the presence of dental caries. Total OHIP14 scores were not influenced by the method of administration. However, the use of the OHIP14 in the questionnaire format may result in lower completion rates and loss of data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cetamina tem demonstrado efeito analgésico em doses subanestésicas, além da manutenção da estabilidade dos parâmetros fisiológicos. O estudo objetivou avaliar os efeitos cardiorrespiratórios e a analgesia pós-operatória da cetamina administrada por via epidural, por infusão intravenosa contínua ou pela associação de ambas, em cães submetidos à osteossíntese de fêmur. Foram utilizadas 25 cadelas, hígidas, distribuídas aleatoriamente em quatro grupos: CEP (2mg kg-1 de cetamina associada à lidocaína 2% via epidural), CIV (lidocaína 2% via epidural e 1mg kg-1 de cetamina IV seguido de infusão contínua IV com 100µg kg min-1 da mesma), CIVEP (2mg kg-1 de cetamina associada à lidocaína 2% via epidural e 1mg kg-1 de cetamina IV, seguido de infusão contínua IV com 100µg kg min-1) e CON (anestesia epidural com lidocaína 2%). Avaliaram-se FC, f, PAS, PAM, PAD, T°C, tempo de bloqueio motor e analgesia pós-operatória por meio de escala analógica visual. Houve elevação da FC no CIV e diminuição desse parâmetro no CEP. As pressões arteriais mantiveram-se dentro dos valores fisiológicos e não foram observadas diferenças na f e T°C. O tempo de duração do bloqueio anestésico foi potencializado nos grupos que receberam cetamina epidural, diferindo significativamente em relação ao controle. O tempo para a analgesia resgate não diferiu entre os grupos. Conclui-se que a administração de cetamina pela via epidural, por infusão contínua intravenosa ou pela associação de ambas promoveu estabilidade cardiorrespiratória no período transcirúrgico, porém não foi capaz de prolongar a duração da analgesia pós-operatória em cães submetidos à osteossíntese de fêmur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A contemporaneidade contempla formas de estruturação da subjetividade amplamente perpassadas por condições de existência socioculturais e econômicas. Estas, por sua vez, têm promovido laços intersubjetivos frágeis, cujo funcionamento psíquico pode ter uma organização de base "falso-self". Autores também demonstram que diversas instituições atuais se tornaram "fluidas" na passagem da modernidade para a "modernidade líquida". Isto contribuiu para a perda de referências sólidas que, outrora, davam sentido e direcionamento para o ser humano. Em decorrência há uma interferência direta na construção da "confiança madura", visto que os sinais de angústia da contemporaneidade podem ser um desorganizador do funcionamento psíquico, além de promoverem o isolamento, a desconfiança no ambiente e no outro, laços mal-atados e funcionamentos de base "falso-self".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Compare parents' reports of youth problems (PRYP) with adolescent problems self-reports (APSR) pre/post behavioral treatment of nocturnal enuresis (NE) based on the use of a urine alarm. MATERIALS AND METHODS: Adolescents (N = 19) with mono-symptomatic (primary or secondary) nocturnal enuresis group treatment for 40 weeks. Discharge criterion was established as 8 weeks with consecutive dry nights. PRYP and APSR were scored by the Child Behavior Checklist (CBCL) and Youth Self-Report (YSR). RESULTS: Pre-treatment data: 1) Higher number of clinical cases based on parent report than on self-report for Internalizing Problems (IP) (13/19 vs. 4/19), Externalizing Problems (EP) (7/19 vs. 5/19) and Total Problem (TP) (11/19 vs. 5/19); 2) Mean PRYP scores for IP (60.8) and TP (61) were within the deviant range (T score ≥ 60); while mean PRYP scores for EP (57.4) and mean APSR scores (IP = 52.4, EP = 49.5, TP = 52.4) were within the normal range. Difference between PRYP' and APSR' scores was significant. Post treatment data: 1) Discharge for majority of the participants (16/19); 2) Reduction in the number of clinical cases on parental evaluation: 9/19 adolescents remained within clinical range for IP, 2/19 for EP, and 7/19 for TP. 3) All post-treatment mean scores were within the normal range; the difference between pre and post evaluation scores was significant for PRYP. CONCLUSIONS: The behavioral treatment based on the use of urine alarm is effective for adolescents with mono-symptomatic (primary and secondary) nocturnal enuresis. The study favors the hypothesis that enuresis is a cause, not a consequence, of other behavioral problems.