216 resultados para IDENTIFICATION TEST AUDIT


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was aimed at assessing the psychometric qualities of the fast alcohol screening test (FAST), and at comparing these qualities to those of the alcohol use disorders identification test (AUDIT) in three samples of Brazilian adults: (i) subjects attended at an emergency department (530); (ii) patients from a psychosocial care center (40); and (iii) university students (429). The structured clinical interview for diagnosis (SCID)-IV was used as gold standard. The FAST demonstrated high test-retest and interrater reliability coefficients, as well as high predictive and concurrent validity values. The results attest the validity and reliability of the Brazilian version of the FAST for the screening of indicators of alcohol abuse and dependence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The University of Pennsylvania Smell Identification Test (SIT) is the most cited olfactory test in the literature because it is easy to perform and there is high test-retest reliability. There were no standardized olfaction values in a normal Brazilian population. Aim: To measure the SIT score in a group of Brazilians, and to assess the level of difficulty when implementing the test. Study design: A cross-sectional study. Materials and Methods: The SIT was applied in 25 Brazilian volunteers of various income levels who presented no olfactory complaints. Following the test, subjects answered a questionnaire with a visual analog scale (VAS) for the level of difficulty. Results: The mean in the sample of Brazilians was 32.5 (SD: 3.48) our of 40; this is below what is considered normal for US citizens. The level of difficulty was on average 26 mm (SD: 24.68) in the VAS, but it trended towards easy; 4(16%) participants did not recognize some of the odors under `alternatives`. Conclusion: In this pilot study, there was evidence of good test applicability; the score of the sample of Brazilians was just below normosmia. Further studies are needed to confirm the existence of differences between people of different income levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This study was aimed at assessing the psychometric qualities of the abbreviated versions of the Alcohol Use Disorders Identification Test (AUDIT-3, AUDIT-4, AUDIT-C, AUDIT-PC, AUDIT-QF, FAST, and Five-Shot) and at comparing them to the 10-item AUDIT and the CAGE in 2 samples of Brazilian adults. Methods: The validity and internal consistency of the scales were assessed in a sample of 530 subjects attended at an emergency department and at a Psychosocial Care Center for Alcohol and Drugs. The Structured Clinical Interview for DSM-IV was used as the diagnostic comparative measure for the predictive validity assessment. The concurrent validity between the scales was analyzed by means of Pearson`s correlation coefficient. Results: The assessment of the predictive validity of the abbreviated versions showed high sensitivity (of 0.78 to 0.96) and specificity (of 0.74 to 0.94) indices, with areas under the curve as elevated as those of the AUDIT (0.89 and 0.92 to screen for abuse and 0.93 and 0.95 in the screening of dependence). The CAGE presented lower indices: 0.81 for abuse and 0.87 for dependence. The analysis of the internal consistency of the AUDIT and its versions exhibited Cronbach`s alpha coefficients between 0.83 and 0.94, while the coefficient for the CAGE was 0.78. Significant correlations were found between the 10-item AUDIT and its versions, ranging from 0.91 to 0.99. Again, the results for the CAGE were satisfactory (0.77), although inferior to the other instruments. Conclusions: The results obtained in this study confirm the validity of the abbreviated versions of the AUDIT for the screening of alcohol use disorders and show that their psychometric properties are as satisfactory as those of the 10-item AUDIT and the CAGE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: The aim of this paper was to compare the quantity and frequency of alcohol use and its associated negative consequences between two groups of college students who were identified as being ""risky drinkers."" Subjects were randomly allocated in a clinical trial to intervention or control groups. Methods: Risky drinking use was defined as Alcohol Use Disorders Identification Test (AUDIT) >= 8 and/or Rutgers Alcohol Problem Index (RAPI) >= 5 problems in the previous year. Students who had undergone the Brief Alcohol Screening and Intervention for College Students (BASICS) (N = 145 at baseline; 142 at 12 months, and 103 at 24 months, loss of 29.7%) were compared with a control group (N = 121 at baseline; 121 at 12 months and 113 at 24 months, loss of 9.3%), the nonintervention group. Variables included drinking frequency, quantity and peak consumption, dependence assessment, and family and friends` abuse assessment. Results: Treated students at a 24-month follow-up decreased quantity of alcohol use per occasion and lowered AUDIT and RAPI scores. Conclusions: This is the first brief intervention work on risky drinking with college students in Brazil and the results are encouraging. However, it is difficult to conduct individual prevention strategies in a country where culture fosters heavy drinking through poor public policy on alcohol and lack of law enforcement.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Standardized olfactory tests are now available to quantitatively assess disorders of olfaction. A Brazilian-Portuguese version of the University of Pennsylvania Smell Identification Test (UPSIT) is currently being developed specifically for the Brazilian population. The most recent Brazilian-Portuguese version of the UPSIT (UPSIT-Br2) was administered to 88 Brazilian subjects who had no history of neurological or otorhinolaryngological disease. UPSIT-Br2 scores decreased with age, were lower in men than in women, and were lower in subjects with lower income. The degree to which the poorer performance of subjects with lower socio-economic status reflects lack of familiarity with test items is not known. Although this version of the UPSIT provides a sensitive and useful test of smell function for the Brazilian population, a revision of some test items is needed to achieve comparable norms to those found using the North American UPSIT in the United States.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this study, the innovation approach is used to estimate the measurement total error associated with power system state estimation. This is required because the power system equations are very much correlated with each other and as a consequence part of the measurements errors is masked. For that purpose an index, innovation index (II), which provides the quantity of new information a measurement contains is proposed. A critical measurement is the limit case of a measurement with low II, it has a zero II index and its error is totally masked. In other words, that measurement does not bring any innovation for the gross error test. Using the II of a measurement, the masked gross error by the state estimation is recovered; then the total gross error of that measurement is composed. Instead of the classical normalised measurement residual amplitude, the corresponding normalised composed measurement residual amplitude is used in the gross error detection and identification test, but with m degrees of freedom. The gross error processing turns out to be very simple to implement, requiring only few adaptations to the existing state estimation software. The IEEE-14 bus system is used to validate the proposed gross error detection and identification test.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work deals with a procedure for model re-identification of a process in closed loop with ail already existing commercial MPC. The controller considered here has a two-layer structure where the upper layer performs a target calculation based on a simplified steady-state optimization of the process. Here, it is proposed a methodology where a test signal is introduced in a tuning parameter of the target calculation layer. When the outputs are controlled by zones instead of at fixed set points, the approach allows the continuous operation of the process without an excessive disruption of the operating objectives as process constraints and product specifications remain satisfied during the identification test. The application of the method is illustrated through the simulation of two processes of the oil refining industry. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Smell identification tests may be of routine clinical value in the differential diagnosis of PD but are subject to cultural variation and have not been systematically evaluated in the Brazilian population. We have applied culturally adapted translations of the University of Pennsylvania 40-item smell identification test (UPSIT-40) and the 16-item identification test from Sniffin` Sticks (SS-16) to nondemented Brazilian PD patients and controls. Pearson`s correlation coefficient between the test scores was 0.76 (95% CI 0.70-0.81, n = 204, P < 0.001). To calculate reliability measures for each test we used the diagnosis (either PD or control) as outcome variable for separate logistic regression analyses using the score in the UPSIT-40 or the SS-16 as a covariate. The SS-16 specificity was 89.0% with a sensitivity of 81.1% (106 PD and 118 controls). The UPSIT-40 specificity was 83.5% and its sensitivity 82.1% (95 PD and 109 controls). Regression curves were used to associate an individual`s smell test score with the probability of belonging to the PD, as opposed to the control group. Our data provide support for the use of the UPSIT-40 and SS-16 to help distinguish early PD from controls. (c) 2008 Movement Disorder Society

Relevância:

80.00% 80.00%

Publicador:

Resumo:

LRRK2 mutations can cause familial and sporadic Parkinson`s disease (PD) with Lewy-body pathology at post-mortem. Studies of olfaction in LRRK2 are sparse and incongruent. We applied a previously validated translation of the 16 item smell identification test from Sniffin` Sticks (SS-16) to 14 parkinsonian carriers of heterozygous G2019S LRRK2 mutation and compared with 106 PD patients and 118 healthy controls. The mean SS-16 score in LRRK2 was higher than in PD (p < 0.001, 95% CI for beta = -4.7 to -1.7) and lower than in controls (p = 0.007, 95% CI for beta = +0.6 to +3.6). In the LRRK2 group, subjects with low scores had significantly more dyskinesia. They also had younger age of onset, longer disease duration, and reported less frequently a family history of PD, but none of these other differences reached significance. Odor identification is diminished in LRRK2 parkinsonism but not to the same extent as in idiopathic PD. (C) 2010 Movement Disorder Society

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A way of coupling digital image correlation (to measure displacement fields) and boundary element method (to compute displacements and tractions along a crack surface) is presented herein. It allows for the identification of Young`s modulus and fracture parameters associated with a cohesive model. This procedure is illustrated to analyze the latter for an ordinary concrete in a three-point bend test on a notched beam. In view of measurement uncertainties, the results are deemed trustworthy thanks to the fact that numerous measurement points are accessible and used as entries to the identification procedure. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Marker assisted selection depends on the identification of tightly linked association between marker and the trait of interest. In the present work, functional (EST-SSRs) and genomic (gSSRs) microsatellite markers were used to detect putative QTLs for sugarcane yield components (stalk number, diameter and height) and as well as for quality parameters (Brix, Pol and fibre) in plant cane. The mapping population (200 individuals) was derived from a bi-parental cross (IACSP95-3018 x IACSP93-3046) from the IAC Sugarcane Breeding Program. As the map is under construction, single marker trait association analysis based on the likelihood ratio test was undertaken to detect the QTLs. Of the 215 single dose markers evaluated (1:1 and 3:1), 90 (42%) were associated with putative QTLs involving 43 microsatellite primers (18 gSSRs and 25 EST-SSRs). For the yield components, 41 marker/trait associations were found: 20 for height, 6 for diameter and 15 for stalk number. An EST-SSRs marker with homology to non-phototropic hypocotyls 4 (NPH4) protein was associated with a putative QTL with positive effect for diameter as also with a negative effect for stalk number. In relation to the quality parameters, 18 marker trait associations were found for Brix, 19 for Pol, and 12 for fibre. For fibre, 58% of the QTLs detected showed a negative effect on this trait. Some makers associated with QTLs with a negative effect for fibre showed a positive effect for Pol, reflecting the negative correlation generally observed between these traits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To identify the CAMCOG sub-items that best contribute for the identification of patients with mild cognitive impairment (MCI) and incipient Alzheimer`s disease (AD) in clinical practice. Methods: Cross-sectional assessment of 272 older adults (98 MCI, 82 AD, and 92 controls) with a standardized neuropsychological battery and the CAMCOG schedule. Backward logistic regression analysis with diagnosis (MCI and controls) as dependent variable and the sub-items of the CAMCOG as independent variable was carried out to determine the CAMCOG sub-items that predicted the diagnosis of MCI. Results: Lower scores on Language, Memory, Praxis, and Calculation CAMCOG sub-items were significantly associated with the diagnosis of MCI. A composite score obtained by the sum of these scores significantly discriminated MCI patients from comparison groups. This reduced version of the CAMCOG showed similar diagnostic accuracy than the original schedule for the identification of patients with MCI as compared to controls (AUC = 0.80 +/- 0.03 for the reduced CAMCOG; AUC = 0.79 +/- 0.03 for the original CAMCOG). Conclusion: This reduced version of the CAMCOG had similar diagnostic properties as the original CAMCOG and was faster and easier to administer, rendering it more suitable for the screening of subtle cognitive deficits in general clinical practice. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Identification of all important community members as well as of the numerically dominant members of a community are key aspects of microbial community analysis of bioreactor samples. A systematic study was conducted with artificial consortia to test whether denaturing gradient gel electrophoresis (DGCE) is a reliable technique to obtain such community data under conditions where results would not be affected by differences in DNA extraction efficiency from cells. A total of 27 consortia were established by mixing DNA extracted from Escherichia coli K12, Burkholderia cepacia and Stenotrophomonas maltophilia in different proportions. Concentrations of DNA of single organisms in the consortia were either 0.04, 0.4 or 4 ng/mu l. DGGE-PCR of genomic DNA with primer sets targeted at the V3 and V6-V8 regions of the 16S rDNA failed to detect the three community members in only 7% of consortia, but provided incorrect information about dominance or co-dominance for 85% and 89% of consortia with the primer sets for the V6-V8 and V3 regions, respectively. The high failure rate in detection of dominant B. cepacia with the primers for the V6-V8 region was attributable to a single nucleoticle primer mismatch in the target sequences of both, the forward and reverse primer. Amplification bias in PCR of E. coli and S. maltophilia for the V6-V8 region and for all three organisms for the V3 region occurred due to interference of genomic DNA in PCR-DGGE, since a nested PCR approach, where PCR-DGGE was started from mixtures of 16S rRNA genes of the organisms, provided correct information about the relative abundance of original DNA in the sample. Multiple bands were not observed in pure culture amplicons produced with the V6-V8 primer pair, but pure culture V3 DGGE profiles of E. coli, S. maltophilia and B. cepacia contained 5, 3 and 3 bands, respectively. These results demonstrate DGGE was suitable for identification of all important community members in the three-membered artificial consortium, but not for identification of the dominant organisms in this small community. Multiple DGGE bands obtained for single organisms with the V3 primer pair could greatly confound interpretation of DGGE profiles. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coccidiosis are the major parasitic diseases in poultry and other domestic animals including the domestic rabbit (Oryctolagus cuniculus). Eleven distinct Eimeria species have been identified in this host, but no PCR-based method has been developed so far for unequivocal species differentiation. In this work, we describe the development of molecular diagnostic assays that allow for the detection and discrimination of the 11 Eimeria species that infect rabbits. We determined the nucleotide sequences of the ITS1 ribosomal DNAs and designed species-specific primers for each species. We performed specificity tests of the assays using heterologous sets of primers and DNA samples, and no cross-specific bands were observed. We obtained a detection limit varying from 500 fg to 1 pg, which corresponds approximately to 0.8-1.7 sporulated oocysts, respectively. The test reported here showed good reproducibility and presented a consistent sensitivity with three different brands of amplification enzymes. These novel diagnostic assays will permit population surveys to be performed with high sensitivity and specificity, thus contributing to a better understanding of the epidemiology of this important group of coccidian parasites. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A real-time polymerase chain reaction (PCR) test was developed on the basis of the Leishmania glucose-6-phosphate dehydrogenase locus that enables identification and quantification of parasites. Using two independent pairs of primers in SYBR-Green assays, the test identified etiologic agents of cutaneous leishmaniasis belonging to both subgenera, Leishmania (Viannia) and Leishmania (Leishmania) in the Americas. Furthermore, use of TaqMan probes enables distinction between L. (V.) braziliensis or L. (V.) peruviania from the other L. (Viannia) species. All assays were negative with DNA of related trypanosomatids, humans, and mice. The parasite burden was estimated by normalizing the number of organisms per total amount of DNA in the sample or per host glyceraldehyde-3-phosphate dehydrogenase copies. The real-time PCR assay for L. (Leishmania) subgenus showed a good linear correlation with quantification on the basis of a limiting dilution assay in experimentally infected mice. The test successfully identifies and quantifies Leishmania in human biopsy specimens and represents a new tool to study leishmaniasis.