44 resultados para City Clouds
Resumo:
This work describes the seasonal and diurnal variations of downward longwave atmospheric irradiance (LW) at the surface in Sao Paulo, Brazil, using 5-min-averaged values of LW, air temperature, relative humidity, and solar radiation observed continuously and simultaneously from 1997 to 2006 on a micrometeorological platform, located at the top of a 4-story building. An objective procedure, including 2-step filtering and dome emission effect correction, was used to evaluate the quality of the 9-yr-long LW dataset. The comparison between LW values observed and yielded by the Surface Radiation Budget project shows spatial and temporal agreement, indicating that monthly and annual average values of LW observed in one point of Sao Paulo can be used as representative of the entire metropolitan region of Sao Paulo. The maximum monthly averaged value of the LW is observed during summer (389 +/- 14 W m(-2): January), and the minimum is observed during winter (332 +/- 12 W m(-2); July). The effective emissivity follows the LW and shows a maximum in summer (0.907 +/- 0.032; January) and a minimum in winter (0.818 +/- 0.029; June). The mean cloud effect, identified objectively by comparing the monthly averaged values of the LW during clear-sky days and all-sky conditions, intensified the monthly average LW by about 32.0 +/- 3.5 W m(-2) and the atmospheric effective emissivity by about 0.088 +/- 0.024. In August, the driest month of the year in Sao Paulo, the diurnal evolution of the LW shows a minimum (325 +/- 11 W m(-2)) at 0900 LT and a maximum (345 12 W m-2) at 1800 LT, which lags behind (by 4 h) the maximum diurnal variation of the screen temperature. The diurnal evolution of effective emissivity shows a minimum (0.781 +/- 0.027) during daytime and a maximum (0.842 +/- 0.030) during nighttime. The diurnal evolution of all-sky condition and clear-sky day differences in the effective emissivity remain relatively constant (7% +/- 1%), indicating that clouds do not change the emissivity diurnal pattern. The relationship between effective emissivity and screen air temperature and between effective emissivity and water vapor is complex. During the night, when the planetary boundary layer is shallower, the effective emissivity can be estimated by screen parameters. During the day, the relationship between effective emissivity and screen parameters varies from place to place and depends on the planetary boundary layer process. Because the empirical expressions do not contain enough information about the diurnal variation of the vertical stratification of air temperature and moisture in Sao Paulo, they are likely to fail in reproducing the diurnal variation of the surface emissivity. The most accurate way to estimate the LW for clear-sky conditions in Sao Paulo is to use an expression derived from a purely empirical approach.
Resumo:
This study investigates how the summer thunderstorms developed over the city of Sao Paulo and if the pollution might affect its development or characteristics during the austral summer (December-January-February-March, DJFM months). A total of 605 days from December 1999 to March 2004 was separated as 241 thunderstorms days (TDs) and 364 non-thunderstorm days (NTDs). The analyses are performed by using hourly measurements of air temperature (T), web-bulb temperature (Tw), surface atmospheric pressure (P), wind velocity and direction, rainfall and thunder and lightning observations collected at the Meteorological Station of the University of Sao Paulo in conjunction with aerosol measurements obtained by AERONET (Aerosol Robotic Network), and the NCEP-DOE (National Centers for Environmental Prediction Department of Energy) reanalysis and radiosondes. The wind diurnal cycle shows that for TDs the morning flow is from the northwest rotating to the southeast after 16: 00 local time (LT) and it remains from the east until the night. For the NTDs, the wind is well characterized by the sea-breeze circulation that in the morning has the wind blowing from the northeast and in the afternoon from the southeast. The TDs show that the air temperature diurnal cycle presents higher amplitude and the maximum temperature of the day is 3.2 degrees C higher than in NTDs. Another important factor found is the difference between moisture that is higher during TDs. In terms of precipitation, the TDs represent 40% of total of days analyzed and those days are responsible for more than 60% of the total rain accumulation during the summer, for instance 50% of the TDs had more than 15.5mm day(-1) while the NTDs had 4 mm day(-1). Moreover, the rainfall distribution shows that TDs have higher rainfall rate intensities and an afternoon precipitation maximum; while in the NTDs there isn`t a defined precipitation diurnal cycle. The wind and temperature fields from NCEP reanalysis concur with the local weather station and radiosonde observations. The NCEP composites show that TDs are controlled by synoptic circulation characterized by a pre-frontal situation, with a baroclinic zone situated at southern part of Sao Paulo. In terms of pollution, this study employed the AERONET data to obtain the main aerosol characteristics in the atmospheric column for both TDs and NTDs. The particle size distribution and particle volume size distribution have similar concentrations for both TDs and NTDs and present a similar fine and coarse mode mean radius. In respect to the atmospheric loading, the aerosol optical depth (AOD) at different frequencies presented closed mean values for both TDs and NTDs that were statistically significant at 95% level. The spectral dependency of those values in conjunction with the Angstrom parameter reveal the higher concentration of the fine mode particles that are more likely to be hygroscopic and from urban areas. In summary, no significant aerosol effect could be found on the development of summer thunderstorms, suggesting the strong synoptic control by the baroclinic forcing for deep convective development. (C) 2010 Published by Elsevier B. V.
Resumo:
Piperaceae species have been placed among the basal angiosperm and are adapted to a variety of habitats including moist forests, secondary vegetation and dry high lands. The major anatomical/morphology features are of small trees, vines, and shrubs for Piper species, while the epiphytic and succulent characteristics are predominant forms among Peperomia species. Their secondary chemistry can be mostly represented by amides, phenylpropanoids/lignoids, and chromenes in addition to a phletoria of biosynthetically mixed-origin secondary compounds. Although several amides and lignans are known as insecticides, several phytophagous insects, among which some considered pests of economic importance, have been observed feeding vigorously on Piperaceae species. Herein we describe the feeding preferences of fourteen phytophagous species of Coleoptera, Lepidoptera and Hemiptera over approximately fifty Piperaceae species observed in São Paulo, SP, Brazil, in a long-term basis.
Resumo:
The present research deals with two mural paintings made in 1947 with the fresco technique by Fulvio Pennacchi in the Catholic Chapel of the Hospital das Clínicas (São Paulo City, Brazil), namely the Virgin Annunciation and the Supper at Emmaus. This study regards the materials and painting techniques used by the artist, based on historical research,on in situ observations and laboratory analytical techniques (stereomicroscopy,scanning electron microscopy with an energy dispersive spectrometer, X-ray diffractometry, electron microprobe, images obtained with UV-light), aiming to improve the methods of characterization of objects of our cultural heritage, and to enhance its preservation accordingly. The results lead to the identification of the plaster components and of distinct layers in the frescoes, besides further information on grain size, impurities and textures, composition of pigments, and features of deterioration, such as efflorescences. The degree of degradation of the murals painting was assessed by this way. Our data suggest that a single layer of plaster was used by Pennacchi, as a common mortar with fine- and medium-grained aggregates. Differences in texture were obtained by adding gypsum to the plaster.
Resumo:
OBJECTIVE: To evaluate suicide seasonality in the city of São Paulo within an urban area and tropical zone. METHOD: Suicides were evaluated using the chi-square test and analysis of variance (ANOVA) by comparing monthly, quarterly and half-yearly variations, differentiating by gender. Analyses of time series were carried out using the autocorrelation function and periodogram, while the significance level for seasonality was confirmed with the Fisher's test. RESULTS: The suicides of the period between 1979 and 2003 numbered 11,434 cases. Differences were observed in suicides occurring in Spring and Autumn for the total sample (ANOVA: p-value = 0.01), and in the male sample (ANOVA: p-value = 0.02). For the analysis of time series, seasonality was significant only for the period of 7 months in the male sample (p-value = 0.04). DISCUSSION: In this study, no significant seasonal differences were observed in the occurrences of suicides, with the exception of the male sample. The differences observed did not correspond with the pattern described in studies carried out in temperate zones. Some of the climatic particularities of the tropical zone might explain the atypical pattern of seasonality of suicides found in large populations within an urban area and tropical zone.
Resumo:
The network of HIV counseling and testing centers in São Paulo, Brazil is a major source of data used to build epidemiological profiles of the client population. We examined HIV-1 incidence from November 2000 to April 2001, comparing epidemiological and socio-behavioral data of recently-infected individuals with those with long-standing infection. A less sensitive ELISA was employed to identify recent infection. The overall incidence of HIV-1 infection was 0.53/100/year (95% CI: 0.31-0.85/100/year): 0.77/100/year for males (95% CI: 0.42-1.27/100/year) and 0.22/100/ year (95% CI: 0.05-0.59/100/year) for females. Overall HIV-1 prevalence was 3.2% (95% CI: 2.8-3.7%), being 4.0% among males (95% CI: 3.3-4.7%) and 2.1% among females (95% CI: 1.6-2.8%). Recent infections accounted for 15% of the total (95% CI: 10.2-20.8%). Recent infection correlated with being younger and male (p = 0.019). Therefore, recent infection was more common among younger males and older females.
Resumo:
OBJECTIVE: To analyze the monounsaturated and polyunsaturated trans fatty acid intake among the general population. METHODS: A cross-sectional study was conducted in São Paulo, Southeastern Brazil, in 2003, on a representative sample of 2,298 male and female subjects, including 803 adolescents (12 to 19 years), 713 adults (20 to 59 years) and 782 elderly people (60 years or over). Food intake was measured using 24-hour recall. Mean trans fatty acid intake was described according to gender and age group. RESULTS: The mean trans fatty acid intake was 5.0 g/day (SE = 0.1), accounting for 2.4% (SE = 0.1) of total energy and 6.8% (SE = 0.1) of total lipids. The adolescents had the highest mean intake levels (7.4 g/day; 2.9% of energy) while the adults and the elderly had similar intake (2.2% of energy for both; 6.4% of lipids and 6.5% of lipids, respectively). The mean trans fatty acid intake among adult and elderly women (approximately 2.5% of energy and 7.0% of lipids) was higher than among men in the same age group. The food item with the highest contribution towards trans fatty acids was margarine, accounting for more than 30% of total intake, followed by filled cookies among adolescents and meat among adults and the elderly. CONCLUSIONS: The trans fatty acid intake is above the level recommended by the World Health Organization. Replacement of the trans fatty acids in manufactured food items may be an effective measure for reducing trans fatty acid intake in Brazil.
Resumo:
The present study assessed the prevalence of anti-Leishmania spp. antibodies in dogs from the city of Monte Negro, State of Rondônia, Brazil. ELISA (NE > 3) and IFAT (>1:40) were used to evaluate 161 serum samples collected from rural dogs from Monte Negro. Forty-five (27.9%) dogs were positive by ELISA tests and five (3.1%) were positive by IFAT. The present study showed for the first time the frequency of exposure to Leishmania spp. in dogs in the State of Rondônia, Amazon Region.
Resumo:
INTRODUCTION: Spotted fevers are emerging zoonoses caused by Rickettsia species in the spotted fever group (SFG). Rickettsia rickettsii is the main etiologic agent of Brazilian spotted fever (BSF) and it is transmitted by Amblyomma spp. ticks. METHODS: The study aimed to investigate SFG rickettsiae in the Arthur Thomas Municipal Park in Londrina, PR, by collecting free-living ticks and ticks from capybaras and blood samples from personnel working in these areas. Samples from A. dubitatum and A. cajennense were submitted for PCR in pools to analyze the Rickettsia spp. gltA (citrate synthase gene). RESULTS: All the pools analyzed were negative. Human sera were tested by indirect immunofluorescence assay with R. rickettsii and R. parkeri as antigens. Among the 34 sera analyzed, seven (20.6%) were reactive for R. rickettsii: four of these had endpoint titers equal to 64, 2 titers were 128 and 1 titer was 256. None of the samples were reactive for R. parkeri. An epidemiological questionnaire was applied to the park staff, but no statistically significant associations were identified. CONCLUSIONS: The serological studies suggest the presence of Rickettsiae related to SFG that could be infecting the human population studied; however, analysis of the ticks collected was unable to determine which species may be involved in transmission to humans.
Resumo:
The presence of mutations associated with integrase inhibitor (INI) resistance among INI-naive patients may play an important clinical role in the use of those drugs Samples from 76 HIV-1-infected subjects naive to INIs were submitted to direct sequencing. No differences were found between naive (25%) subjects and subjects on HAART (75%). No primary mutation associated with raltegravir or elvitegravir resistance was found. However, 78% of sequences showed at least one accessory mutation associated with resistance. The analysis of the 76 IN sequences showed a high polymorphic level on this region among Brazilian HIV-1-infected subjects, including a high prevalence of aa substitutions related to INI resistance. The impact of these findings remains unclear and further studies are necessary to address these questions.
Resumo:
Blood serum samples were collected from 451 bats captured within the Sao Paulo city from April 2007 to November 2008, and individually tested by indirect immunofluorescence assay against antigens derived from five Rickettsia species reported to occur in Brazil: the spotted fever group (SFG) species R. rickettsii, R. parkeri, R. amblyommii, R. rhipicephali, and the ancestral group species R. bellii. For this purpose, an anti-bat immunoglobulin G was produced and used in the present study. Overall, 8.6% (39/451), 9.5% (34/358), 7.8% (28/358), 1.1% (4/358), and 0% (0/358) serum samples were reactive to R. rickettsii, R. parkeri, R. amblyommii, R. rhipicephali, and R. bellii, respectively. Endpoint titers of reactive sera ranged from 64 to 256. From 20 bat species of 3 different families (Molossidae, Vespertilionidae, and Phyllostomidae), 46 animals were shown to be reactive to at least one rickettsial antigen. Seropositivity per bat species ranged from 0% to 33.3%. Most of the serologically positive sera reacted with two or more rickettsial antigens. Seropositivity for SFG rickettsial antigens in the absence of reactivity against R. bellii (ancestral group species) suggests that bats from Sao Paulo city can be infected by SFG rickettsiae. The possible role of soft ticks in serving as vectors of SFG rickettsiae to bats within the Sao Paulo city, associated to its public health risks, is discussed.
Resumo:
Multifilter rotating shadowband radiometer (MFRSR) calibration values for aerosol optical depth (AOD) retrievals were determined by means of the general method formulated by Forgan [Appl. Opt. 33, 4841 (1994)] at a polluted urban site. The obtained precision is comparable with the classical method, the Langley plot, applied on clean mountaintops distant of pollution sources. The AOD retrieved over Sao Paulo City with both calibration procedures is compared with the Aerosol Robotic Network data. The observed results are similar, and, except for the shortest wavelength (415 nm), the MFRSR`s AOD is systematically overestimated by similar to 0.03. (c) 2008 Optical Society of America.
Resumo:
The city of Maringa, located in the Northwest of Parana State, Brazil, was part of an extensive area colonized by the Companhia de Terras Norte do Parana replaced by the Companhia Melhoramentos Norte do Parana. Starting from a modem project elaborated in midlles of 1940's, Maringa emerged quickly amid the forest. We analyzed the initial plan, the projects for the reformulation of the central area and the tendencies of the public actions in the urban area that turn for real estate promotion and disrespect the popular participation. In its regional scale, Maringa follows the same orientation of cities that are used by the The obsession for the modernity takes to the systematic construction of new spaces that substitute the memory and the urban history in projects that reconduct to the aestheticization and the spectacularization of the urban landscape of Maringa.
Resumo:
As a contribution to the Large-Scale Biosphere-Atmosphere Experiment in Amazonia - Cooperative LBA Airborne Regional Experiment (LBA-CLAIRE-2001) field campaign in the heart of the Amazon Basin, we analyzed the temporal and spatial dynamics of the urban plume of Manaus City during the wet-to-dry season transition period in July 2001. During the flights, we performed vertical stacks of crosswind transects in the urban outflow downwind of Manaus City, measuring a comprehensive set of trace constituents including O(3), NO, NO(2), CO, VOC, CO(2), and H(2)O. Aerosol loads were characterized by concentrations of total aerosol number (CN) and cloud condensation nuclei (CCN), and by light scattering properties. Measurements over pristine rainforest areas during the campaign showed low levels of pollution from biomass burning or industrial emissions, representative of wet season background conditions. The urban plume of Manaus City was found to be joined by plumes from power plants south of the city, all showing evidence of very strong photochemical ozone formation. One episode is discussed in detail, where a threefold increase in ozone mixing ratios within the atmospheric boundary layer occurred within a 100 km travel distance downwind of Manaus. Observation-based estimates of the ozone production rates in the plume reached 15 ppb h(-1). Within the plume core, aerosol concentrations were strongly enhanced, with Delta CN/Delta CO ratios about one order of magnitude higher than observed in Amazon biomass burning plumes. Delta CN/Delta CO ratios tended to decrease with increasing transport time, indicative of a significant reduction in particle number by coagulation, and without substantial new particle nucleation occurring within the time/space observed. While in the background atmosphere a large fraction of the total particle number served as CCN (about 60-80% at 0.6% supersaturation), the CCN/CN ratios within the plume indicated that only a small fraction (16 +/- 12 %) of the plume particles were CCN. The fresh plume aerosols showed relatively weak light scattering efficiency. The CO-normalized CCN concentrations and light scattering coefficients increased with plume age in most cases, suggesting particle growth by condensation of soluble organic or inorganic species. We used a Single Column Chemistry and Transport Model (SCM) to infer the urban pollution emission fluxes of Manaus City, implying observed mixing ratios of CO, NO(x) and VOC. The model can reproduce the temporal/spatial distribution of ozone enhancements in the Manaus plume, both with and without accounting for the distinct (high NO(x)) contribution by the power plants; this way examining the sensitivity of ozone production to changes in the emission rates of NO(x). The VOC reactivity in the Manaus region was dominated by a high burden of biogenic isoprene from the background rainforest atmosphere, and therefore NO(x) control is assumed to be the most effective ozone abatement strategy. Both observations and models show that the agglomeration of NO(x) emission sources, like power plants, in a well-arranged area can decrease the ozone production efficiency in the near field of the urban populated cores. But on the other hand remote areas downwind of the city then bear the brunt, being exposed to increased ozone production and N-deposition. The simulated maximum stomatal ozone uptake fluxes were 4 nmol m(-2) s(-1) close to Manaus, and decreased only to about 2 nmol m(-2) s(-1) within a travel distance >1500 km downwind from Manaus, clearly exceeding the critical threshold level for broadleaf trees. Likewise, the simulated N deposition close to Manaus was similar to 70 kg N ha(-1) a(-1) decreasing only to about 30 kg N ha(-1) a(-1) after three days of simulation.
Resumo:
In-situ measurements in convective clouds (up to the freezing level) over the Amazon basin show that smoke from deforestation fires prevents clouds from precipitating until they acquire a vertical development of at least 4 km, compared to only 1-2 km in clean clouds. The average cloud depth required for the onset of warm rain increased by similar to 350 m for each additional 100 cloud condensation nuclei per cm(3) at a super-saturation of 0.5% (CCN0.5%). In polluted clouds, the diameter of modal liquid water content grows much slower with cloud depth (at least by a factor of similar to 2), due to the large number of droplets that compete for available water and to the suppressed coalescence processes. Contrary to what other studies have suggested, we did not observe this effect to reach saturation at 3000 or more accumulation mode particles per cm(3). The CCN0.5% concentration was found to be a very good predictor for the cloud depth required for the onset of warm precipitation and other microphysical factors, leaving only a secondary role for the updraft velocities in determining the cloud drop size distributions. The effective radius of the cloud droplets (r(e)) was found to be a quite robust parameter for a given environment and cloud depth, showing only a small effect of partial droplet evaporation from the cloud's mixing with its drier environment. This supports one of the basic assumptions of satellite analysis of cloud microphysical processes: the ability to look at different cloud top heights in the same region and regard their r(e) as if they had been measured inside one well developed cloud. The dependence of r(e) on the adiabatic fraction decreased higher in the clouds, especially for cleaner conditions, and disappeared at r(e)>=similar to 10 mu m. We propose that droplet coalescence, which is at its peak when warm rain is formed in the cloud at r(e)=similar to 10 mu m, continues to be significant during the cloud's mixing with the entrained air, cancelling out the decrease in r(e) due to evaporation.