2 resultados para virus mutant

em WestminsterResearch - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of hand hygiene in reducing the spread of pathogens has been long established and this has been highlighted recently in initiatives such as the NHS’s ‘clean your hands’ campaign. However, much of the focus on hand hygiene has concerned effective hand washing; there has been less emphasis on hand drying and its role in hygienic practices. This study aimed to compare three hand drying methods namely paper towels, a warm air dryer and a jet air dryer for their relative ability to disseminate virus particles into the washroom environment during hand drying. A bacteriophage model was used to compare these methods; hands were artificially contaminated with MS2 phage and dried using each device. Both air sampling and contact plates were assessed and a plaque assay was used to quantify virus dissemination. Samples were collected at set times, heights, angles and distances around each device. Both air sampling and contact plate results indicated that the jet air dryer produced significantly more virus dispersal than either paper towels or the warm air dryer in terms of quantity, distance travelled and the time spent circulating in the air around the device and potentially in the washroom environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To use a MS2 bacteriophage model to compare three hand-drying methods, paper towels (PT), a warm air dryer (WAD) and a jet air dryer (JAD), for their potential to disperse viruses and contaminate the immediate environment during use. Methods and Results Participants washed their gloved hands with a suspension of MS2 bacteriophage and hands were dried with one of the three hand-drying devices. The quantity of MS2 present in the areas around each device was determined using a plaque assay. Samples were collected from plates containing the indicator strain, placed at varying heights and distances and also from the air. Over a height range of 0.15-1.65 m, the JAD dispersed an average of >60 and >1300-fold more plaque-forming units (pfu) compared to the WAD and PT (P <0.0001), respectively. The JAD dispersed an average of >20 and >190-fold more pfu in total compared to WAD and PT at all distances tested up to 3 m (P <0.01), respectively. Air samples collected around each device 15 minutes after use indicated that the JAD dispersed an average of >50 and >100-fold more pfu compared to the WAD and PT (P <0.001), respectively. Conclusions Use of the JAD lead to significantly greater and further dispersal of MS2 bacteriophage from artificially contaminated hands when compared to the WAD and PT. Significance and Impact of Study The choice of hand drying device should be considered carefully in areas where infection prevention concerns are paramount, such as healthcare settings and the food industry.