9 resultados para sample complexity
em WestminsterResearch - UK
Resumo:
In this paper, the performance and convergence time comparisons of various low-complexity LMS algorithms used for the coefficient update of adaptive I/Q corrector for quadrature receivers are presented. We choose the optimum LMS algorithm suitable for low complexity, high performance and high order QAM and PSK constellations. What is more, influence of the finite bit precision on VLSI implementation of such algorithms is explored through extensive simulations and optimum wordlengths established.
Resumo:
In this paper digital part of a self-calibrating quadrature-receiver is described, containing a digital calibration-engine. The blind source-separation-based calibration-engine eliminates the RF-impairments in real-time hence improving the receiver's performance without the need for test/pilot tones, trimming or use of power-hungry discrete components. Furthermore, an efficient time-multiplexed calibration-engine architecture is proposed and implemented on an FPGA utilising a reduced-range multiplier structure. The use of reduced-range multipliers results in substantial reduction of area as well as power consumption without a compromise in performance when compared with an efficiently designed general purpose multiplier. The performance of the calibration-engine does not depend on the modulation format or the constellation size of the received signal; hence it can be easily integrated into the digital signal processing paths of any receiver.
Resumo:
The finite length Gold codes used in satellite navigation systems limit their dynamic range, resulting in the introduction of unwanted peaks that can mask out signals of interest. In this paper, a novel cross-correlation interference mitigation technique dealing with this issue is introduced. A brief overview of the multiple access interference problem inherent in satellite navigation systems using the code division multiple access technique is followed by the details of the proposed method. Simulation case studies and analyses of the results detailing weak signal scenarios, carried out entirely using the Global Navigation System Scope, are presented. A comparison of the results is given in the conclusions section along with remarks on the performance of the proposed method and future work to be carried out.
Resumo:
This paper investigates applications of complexity theory in the social sphere and considers its potential contribution to enhance understanding of tourism policy making. Five concepts are identified to explore complex social circumstances and human interactions that influence policy. Social applications of complexity suggest a move towards localised and deeper studies to explore the dynamics of policy enactment in context. It suggests complexity theory might be used as a thinking tool to enable a more holistic approach to policy analysis and investigate policy in its context, considering interactions between different policies/programmes, and the implications of human agency.
Resumo:
This paper proposes a method for analysing the operational complexity in supply chains by using an entropic measure based on information theory. The proposed approach estimates the operational complexity at each stage of the supply chain and analyses the changes between stages. In this paper a stage is identified by the exchange of data and/or material. Through analysis the method identifies the stages where the operational complexity is both generated and propagated (exported, imported, generated or absorbed). Central to the method is the identification of a reference point within the supply chain. This is where the operational complexity is at a local minimum along the data transfer stages. Such a point can be thought of as a ‘sink’ for turbulence generated in the supply chain. Where it exists, it has the merit of stabilising the supply chain by attenuating uncertainty. However, the location of the reference point is also a matter of choice. If the preferred location is other than the current one, this is a trigger for management action. The analysis can help decide appropriate remedial action. More generally, the approach can assist logistics management by highlighting problem areas. An industrial application is presented to demonstrate the applicability of the method.
Resumo:
Indices of post awakening cortisol secretion (PACS), include the rise in cortisol(cortisol awakening response: CAR) and overall cortisol concentrations (e.g. area under the curve with reference to ground: AUCg) in the first 30—45 min. Both are commonly investigated in relation to psychosocial variables. Although sampling within the domestic setting is ecologically valid, participant non-adherence to the required timing protocol results in erroneous measurement of PACS and this may explain discrepancies in the literature linking these measures to trait well-being (TWB). We have previously shown that delays of little over 5 min(between awakening and the start of sampling) to result in erroneous CAR estimates. In this study, we report for the first time on the negative impact of sample timing inaccuracy (verified by electronic-monitoring) on the efficacy to detect significant relationships between PACS and TWB when measured in the domestic setting.Healthy females (N = 49, 20.5 ± 2.8 years) selected for differences in TWB collected saliva samples (S1—4) on 4 days at 0, 15, 30, 45 min post awakening, to determine PACS. Adherence to the sampling protocol was objectively monitored using a combination of electronic estimates of awakening (actigraphy) and sampling times (track caps).Relationships between PACS and TWB were found to depend on sample timing accuracy. Lower TWB was associated with higher post awakening cortisol AUCg in proportion to the mean sample timing accuracy (p < .005). There was no association between TWB and the CAR even taking into account sample timing accuracy. These results highlight the importance of careful electronic monitoring of participant adherence for measurement of PACS in the domestic setting. Mean sample timing inaccuracy, mainly associated with delays of >5 min between awakening and collection of sample 1 (median = 8 min delay), negatively impacts on the sensitivity of analysis to detect associations between PACS and TWB.
Resumo:
This paper presents a low complexity high efficiency decimation filter which can be employed in EletroCardioGram (ECG) acquisition systems. The decimation filter with a decimation ratio of 128 works along with a third order sigma delta modulator. It is designed in four stages to reduce cost and power consumption. The work reported here provides an efficient approach for the decimation process for high resolution biomedical data conversion applications by employing low complexity two-path all-pass based decimation filters. The performance of the proposed decimation chain was validated by using the MIT-BIH arrhythmia database and comparative simulations were conducted with the state of the art.