7 resultados para Translating and interpreting -- Evaluation

em WestminsterResearch - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: NF2 patients develop multiple nervous system tumors including bilateral vestibular schwannomas (VS). The tumors and their surgical treatment are associated with deafness, neurological disability, and mortality. Medical treatment with bevacizumab has been reported to reduce VS growth and to improve hearing. In addition to evaluating these effects, this study also aimed to determine other important consequences of treatment including patient-reported quality of life and the impact of treatment on surgical VS rates. Methods: Patients treated with bevacizumab underwent serial prospective MRI, audiology, clinical, CTCAE-4.0 adverse events, and NFTI-QOL quality-of-life assessments. Tumor volumetrics were classified according to the REiNs criteria and annual VS surgical rates reviewed. Results: Sixty-one patients (59% male), median age 25 years (range, 10–57), were reviewed. Median follow-up was 23 months (range, 3–53). Partial volumetric tumor response (all tumors) was seen in 39% and 51% had stabilization of previously growing tumors. Age and pretreatment growth rate were predictors of response. Hearing was maintained or improved in 86% of assessable patients. Mean NFTI-QOL scores improved from 12.0 to 10.7 (P < .05). Hypertension was observed in 30% and proteinuria in 16%. Twelve treatment breaks occurred due to adverse events. The rates of VS surgery decreased after the introduction of bevacizumab. Conclusion: Treatment with bevacizumab in this large, UK-wide cohort decreased VS growth rates and improved hearing and quality of life. The potential risk of surgical iatrogenic damage was also reduced due to an associated reduction in VS surgical rates. Ongoing follow-up of this cohort will determine the long-term benefits and risks of bevacizumab treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study examined the factorial and construct validity of a Standard Chinese translation of the Body Appreciation Scale (BAS-2; Tylka & Wood-Barcalow, 2015b). Participants were 191 women and 154 men from mainland China who were resident in Hong Kong at the time of recruitment. Results of confirmatory factor analysis indicated that the one-dimensional model of the BAS-2, in which all 10 items loaded onto the same factor, had adequate fit and was invariant across sex. Body appreciation scores had good internal consistency and were significantly correlated with self-esteem and life satisfaction, and, in women, with weight discrepancy and body mass index. There were no significant differences in body appreciation scores between women and men. The present findings suggest that the Standard Chinese translation of the BAS-2 has the same one-dimensional factor structure as its parent scale and may facilitate cross-cultural studies of positive body image.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The inherent analogue nature of medical ultrasound signals in conjunction with the abundant merits provided by digital image acquisition, together with the increasing use of relatively simple front-end circuitries, have created considerable demand for single-bit  beamformers in digital ultrasound imaging systems. Furthermore, the increasing need to design lightweight ultrasound systems with low power consumption and low noise, provide ample justification for development and innovation in the use of single-bit  beamformers in ultrasound imaging systems. The overall aim of this research program is to investigate, establish, develop and confirm through a combination of theoretical analysis and detailed simulations, that utilize raw phantom data sets, suitable techniques for the design of simple-to-implement hardware efficient  digital ultrasound beamformers to address the requirements for 3D scanners with large channel counts, as well as portable and lightweight ultrasound scanners for point-of-care applications and intravascular imaging systems. In addition, the stability boundaries of higher-order High-Pass (HP) and Band-Pass (BP) Σ−Δ modulators for single- and dual- sinusoidal inputs are determined using quasi-linear modeling together with the describing-function method, to more accurately model the  modulator quantizer. The theoretical results are shown to be in good agreement with the simulation results for a variety of input amplitudes, bandwidths, and modulator orders. The proposed mathematical models of the quantizer will immensely help speed up the design of higher order HP and BP Σ−Δ modulators to be applicable for digital ultrasound beamformers. Finally, a user friendly design and performance evaluation tool for LP, BP and HP  modulators is developed. This toolbox, which uses various design methodologies and covers an assortment of  modulators topologies, is intended to accelerate the design process and evaluation of  modulators. This design tool is further developed to enable the design, analysis and evaluation of  beamformer structures including the noise analyses of the final B-scan images. Thus, this tool will allow researchers and practitioners to design and verify different reconstruction filters and analyze the results directly on the B-scan ultrasound images thereby saving considerable time and effort.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper focuses on the role that can be played by urban consolidation centres (UCCs) in reducing freight traffic and its environmental impacts in towns and cities. It is based on the before and after evaluation of a trial led by a major stationery and office supplies company in which urban freight deliveries in central London made from a depot in the suburbs using diesel vehicles were replaced with the use of an urban micro-consolidation centre located in the delivery area together with the use of electrically-assisted cargo tricycles and electric vans. The results show that the total distance travelled and the CO2eq emissions per parcel delivered fell by 20% and 54% respectively as a result of this delivery system. However, the evaluation has also indicated that the distance travelled per parcel rose substantially in the City of London delivery area as a result of the electric vehicles having far smaller load limits in both weight and volume compared with diesel vans. But, at the same time, the trial system was able to virtually eliminate CO2eq emissions per parcel delivered in the City of London. The trial proved successful from the company's perspective in transport, environmental and financial terms. The company therefore decided to continue the operation beyond the end of the trial with it being officially launched during 2010.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, an evaluation of unwanted effects in Multiple Input Multiple Output (MIMO) transmitters is described. Complete 2×2 and 4×4 MIMO Orthogonal Frequency Division Multiplex (OFDM) transmitters are simulated for the purpose of quantifying all potential unwanted effects such as Power Amplifiers' (PAs) nonlinearity, linear and nonlinear crosstalk, and IQ modulator imperfections. An experimental analysis of a 2×2 MIMO transmitter using two-tones and WCDMA signal is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims To use a MS2 bacteriophage model to compare three hand-drying methods, paper towels (PT), a warm air dryer (WAD) and a jet air dryer (JAD), for their potential to disperse viruses and contaminate the immediate environment during use. Methods and Results Participants washed their gloved hands with a suspension of MS2 bacteriophage and hands were dried with one of the three hand-drying devices. The quantity of MS2 present in the areas around each device was determined using a plaque assay. Samples were collected from plates containing the indicator strain, placed at varying heights and distances and also from the air. Over a height range of 0.15-1.65 m, the JAD dispersed an average of >60 and >1300-fold more plaque-forming units (pfu) compared to the WAD and PT (P <0.0001), respectively. The JAD dispersed an average of >20 and >190-fold more pfu in total compared to WAD and PT at all distances tested up to 3 m (P <0.01), respectively. Air samples collected around each device 15 minutes after use indicated that the JAD dispersed an average of >50 and >100-fold more pfu compared to the WAD and PT (P <0.001), respectively. Conclusions Use of the JAD lead to significantly greater and further dispersal of MS2 bacteriophage from artificially contaminated hands when compared to the WAD and PT. Significance and Impact of Study The choice of hand drying device should be considered carefully in areas where infection prevention concerns are paramount, such as healthcare settings and the food industry.