20 resultados para visual terrain analysis
em Universidad de Alicante
Resumo:
Social Rankings es una aplicación web que realiza un seguimiento en tiempo real de entidades en las redes sociales. Detecta y analiza las opiniones sobre estas entidades utilizando técnicas de análisis de sentimientos para generar un informe visual de su valoración y su evolución en el tiempo.
Resumo:
PURPOSE: To evaluate and compare the visual, refractive, contrast sensitivity, and aberrometric outcomes with a diffractive bifocal and trifocal intraocular lens (IOL) of the same material and haptic design. METHODS: Sixty eyes of 30 patients undergoing bilateral cataract surgery were enrolled and randomly assigned to one of two groups: the bifocal group, including 30 eyes implanted with the bifocal diffractive IOL AT LISA 801 (Carl Zeiss Meditec, Jena, Germany), and the trifocal group, including eyes implanted with the trifocal diffractive IOL AT LISA tri 839 MP (Carl Zeiss Meditec). Analysis of visual and refractive outcomes, contrast sensitivity, ocular aberrations (OPD-Scan III; Nidek, Inc., Gagamori, Japan), and defocus curve were performed during a 3-month follow-up period. RESULTS: No statistically significant differences between groups were found in 3-month postoperative uncorrected and corrected distance visual acuity (P > .21). However, uncorrected, corrected, and distance-corrected near and intermediate visual acuities were significantly better in the trifocal group (P < .01). No significant differences between groups were found in postoperative spherical equivalent (P = .22). In the binocular defocus curve, the visual acuity was significantly better for defocus of -0.50 to -1.50 diopters in the trifocal group (P < .04) and -3.50 to -4.00 diopters in the bifocal group (P < .03). No statistically significant differences were found between groups in most of the postoperative corneal, internal, and ocular aberrations (P > .31), and in contrast sensitivity for most frequencies analyzed (P > .15). CONCLUSIONS: Trifocal diffractive IOLs provide significantly better intermediate vision over bifocal IOLs, with equivalent postoperative levels of visual and ocular optical quality.
Resumo:
Background: The aim was to evaluate the visual performance achieved with a new multifocal hybrid contact lens and to compare it with that obtained with two other currently available multifocal soft contact lenses. Methods: This pilot prospective comparative study comprised a total of 16 presbyopic eyes of eight patients ranging in age from 43 to 58 years. All patients were fitted with three different models of multifocal contact lens: Duette multifocal (SynergEyes), Air Optix AQUA multifocal (Alcon) and Biofinity multifocal (CooperVision). Fittings were performed randomly in each patient according to a random number sequence, with a wash-out period between fittings of seven days. At two weeks post-fitting, visual, photopic contrast sensitivity and ocular aberrometry were evaluated. Results: No statistically significant differences were found in distance and near visual acuity achieved with the three different types of multifocal contact lens (p ≥ 0.05). Likewise, no significant differences between lenses were found in the monocular and binocular defocus curve (p ≥ 0.10). Concerning contrast sensitivity, better monocular contrast sensitivities for 6, 12 and 18 cycles per degree were found with the Duette and Air Optix multifocal compared to Biofinity (p = 0.02). Binocularly, differences between lenses were not significant (p ≥ 0.27). Furthermore, trefoil aberration was significantly higher with Biofinity multifocal (p < 0.01) and Air Optix (p = 0.01) multifocal compared to Duette. Conclusions: The Duette multifocal hybrid contact lens seems to provide similar visual quality outcomes in presbyopic patients with low corneal astigmatism, when compared with other soft multifocal contact lenses. This preliminary result should be confirmed in studies with larger samples.
Resumo:
This thesis explores the role of multimodality in language learners’ comprehension, and more specifically, the effects on students’ audio-visual comprehension when different orchestrations of modes appear in the visualization of vodcasts. Firstly, I describe the state of the art of its three main areas of concern, namely the evolution of meaning-making, Information and Communication Technology (ICT), and audio-visual comprehension. One of the most important contributions in the theoretical overview is the suggested integrative model of audio-visual comprehension, which attempts to explain how students process information received from different inputs. Secondly, I present a study based on the following research questions: ‘Which modes are orchestrated throughout the vodcasts?’, ‘Are there any multimodal ensembles that are more beneficial for students’ audio-visual comprehension?’, and ‘What are the students’ attitudes towards audio-visual (e.g., vodcasts) compared to traditional audio (e.g., audio tracks) comprehension activities?’. Along with these research questions, I have formulated two hypotheses: Audio-visual comprehension improves when there is a greater number of orchestrated modes, and students have a more positive attitude towards vodcasts than traditional audios when carrying out comprehension activities. The study includes a multimodal discourse analysis, audio-visual comprehension tests, and students’ questionnaires. The multimodal discourse analysis of two British Council’s language learning vodcasts, entitled English is GREAT and Camden Fashion, using ELAN as the multimodal annotation tool, shows that there are a variety of multimodal ensembles of two, three and four modes. The audio-visual comprehension tests were given to 40 Spanish students, learning English as a foreign language, after the visualization of vodcasts. These comprehension tests contain questions related to specific orchestrations of modes appearing in the vodcasts. The statistical analysis of the test results, using repeated-measures ANOVA, reveal that students obtain better audio-visual comprehension results when the multimodal ensembles are constituted by a greater number of orchestrated modes. Finally, the data compiled from the questionnaires, conclude that students have a more positive attitude towards vodcasts in comparison to traditional audio listenings. Results from the audio-visual comprehension tests and questionnaires prove the two hypotheses of this study.
Resumo:
Póster presentado en OPTYKA Optical Fair 2012, Poznan, Polonia, 9-10 noviembre 2012.
Resumo:
Retinal image quality is commonly analyzed through parameters inherited from instrumental optics. These parameters are defined for ‘good optics’ so they are hard to translate into visual quality metrics. Instead of using point or artificial functions, we propose a quality index that takes into account properties of natural images. These images usually show strong local correlations that help to interpret the image. Our aim is to derive an objective index that quantifies the quality of vision by taking into account the local structure of the scene, instead of focusing on a particular aberration. As we show, this index highly correlates with visual acuity and allows inter-comparison of natural images around the retina. The usefulness of the index is proven through the analysis of real eyes before and after undergoing corneal surgery, which usually are hard to analyze with standard metrics.
Resumo:
This paper aims to assess the discussion forums being used in the programme Especialista Universitario online sobre Tecnologías de la Información y la Comunicación, taught at the University of Alicante, on the basis of the analysis model suggested by Kay (2004). In such a model, it is essential to represent graphically the forum activity so that the visual representation may improve analysis. This research has allowed reaching results which define the forum activity and has contributed with a proposal for multi analysis in the area of assessing participation in communication within online discussion forums.
Resumo:
Las teorías cognitivas han demostrado que el pensamiento humano se encuentra corporeizado; es decir, que accedemos a la realidad mediante nuestros sentidos y no podemos huir de ellos. Para entender y manejar conceptos abstractos utilizamos proyecciones metafóricas basadas en sensaciones corporales. De ahí la ubicuidad de la metáfora en el lenguaje cotidiano. Aunque esta afirmación ha sido ampliamente probada con el análisis del corpus verbal en distintas lenguas, apenas existen investigaciones en el corpus audiovisual. Si las metáforas primarias forman parte de nuestro inconsciente cognitivo, son inherentes al ser humano y consecuencia de la naturaleza del cerebro, deben generar también metáforas visuales. En este artículo, se analizan y discuten una serie de ejemplos para comprobarlo.
Resumo:
Objectives: In Europe, 25% of workers use video display terminals (VDTs). Occupational health surveillance has been considered a key element in the protection of these workers. Nevertheless, it is unclear if guidelines available for this purpose, based on EU standards and available evidence, meet currently accepted quality criteria. The aim of this study was to appraise three sets of European VDT guidelines (UK, France, Spain) in which regulatory and evidence-based approaches for visual health have been formulated and recommendations for practice made. Methods: Three independent appraisers used an adapted AGREE instrument with seven domains to appraise the guidelines. A modified nominal group technique approach was used in two consecutive phases: first, individual evaluation of the three guidelines simultaneously, and second, a face-to-face meeting of appraisers to discuss scoring. Analysis of ratings obtained in each domain and variability among appraisers was undertaken (correlation and kappa coefficients). Results: All guidelines had low domain scores. The domain evaluated most highly was Scope and purpose, while Applicability was scored minimally. The UK guidelines had the highest overall score, and the Spanish ones had the lowest. The analysis of reliability and differences between scores in each domain showed a high level of agreement. Conclusions: These results suggest current guidelines used in these countries need an update. The formulation of evidence-base European guidelines on VDT could help to reduce the significant variation of national guidelines, which may have an impact on practical application.
Resumo:
Background To evaluate the intraocular lens (IOL) position by analyzing the postoperative axis of internal astigmatism as well as the higher-order aberration (HOA) profile after cataract surgery following the implantation of a diffractive multifocal toric IOL. Methods Prospective study including 51 eyes with corneal astigmatism of 1.25D or higher of 29 patients with ages ranging between 20 and 61 years old. All cases underwent uneventful cataract surgery with implantation of the AT LISA 909 M toric IOL (Zeiss). Visual, refractive and corneal topograpy changes were evaluated during a 12-month follow-up. In addition, the axis of internal astigmatism as well as ocular, corneal, and internal HOA (5-mm pupil) were evaluated postoperatively by means of an integrated aberrometer (OPD Scan II, Nidek). Results A significant improvement in uncorrected distance and near visual acuities (p < 0.01) was found, which was consistent with a significant correction of manifest astigmatism (p < 0.01). No significant changes were observed in corneal astigmatism (p = 0.32). With regard to IOL alignment, the difference between the axes of postoperative internal and preoperative corneal astigmatisms was close to perpendicularity (12 months, 87.16° ± 7.14), without significant changes during the first 6 months (p ≥ 0.46). Small but significant changes were detected afterwards (p = 0.01). Additionally, this angular difference correlated with the postoperative magnitude of manifest cylinder (r = 0.31, p = 0.03). Minimal contribution of intraocular optics to the global magnitude of HOA was observed. Conclusions The diffractive multifocal toric IOL evaluated is able to provide a predictable astigmatic correction with apparent excellent levels of optical quality during the first year after implantation.
Resumo:
Background To analyze and compare the relationship between anterior and posterior corneal shape evaluated by a tomographic system combining the Scheimpflug photography and Placido-disc in keratoconus and normal healthy eyes, as well as to evaluate its potential diagnostic value. Methods Comparative case series including a sample of 161 eyes of 161 subjects with ages ranging from 7 to 66 years and divided into two groups: normal group including 100 healthy eyes of 100 subjects, and keratoconus group including 61 keratoconus eyes of 61 patients. All eyes received a comprehensive ophthalmologic examination including an anterior segment analysis with the Sirius system (CSO). Antero-posterior ratios for corneal curvature (k ratio) and shape factor (p ratio) were calculated. Logistic regression analysis was used to evaluate if some antero–posterior ratios combined with other clinical parameters were predictors of the presence of keratoconus. Results No statistically significant differences between groups were found in the antero–posterior k ratios for 3-, 5- and 7-mm diameter corneal areas (p ≥ 0.09). The antero–posterior p ratio for 4.5- and 8-mm diameter corneal areas was significantly higher in the normal group than in the keratoconus group (p < 0.01). The k ratio for 3, 5, and 7 mm was significantly higher in the keratoconus grade IV subgroup than in the normal group (p < 0.01). Furthermore, significant differences were found in the p ratio between the normal group and the keratoconus grade II subgroup (p ≤ 0.01). Finally, the logistic regression analysis identified as significant independent predictors of the presence of keratoconus (p < 0.01) the 8-mm anterior shape factor, the anterior chamber depth, and the minimal corneal thickness. Conclusions The antero-posterior k and p ratios are parameters with poor prediction ability for keratoconus, in spite of the trend to the presence of more prolate posterior corneal surfaces compared to the anterior in keratoconus eyes.
Resumo:
The retina is a very complex neural structure, which performs spatial, temporal, and chromatic processing on visual information and converts it into a compact ‘digital’ format composed of neural impulses. This paper presents a new compiler-based framework able to describe, simulate and validate custom retina models. The framework is compatible with the most usual neural recording and analysis tools, taking advantage of the interoperability with these kinds of applications. Furthermore it is possible to compile the code to generate accelerated versions of the visual processing models compatible with COTS microprocessors, FPGAs or GPUs. The whole system represents an ongoing work to design and develop a functional visual neuroprosthesis. Several case studies are described to assess the effectiveness and usefulness of the framework.
Resumo:
International conference presentations represent one of the biggest challenges for academics using English as a Lingua Franca (ELF). This paper aims to initiate exploration into the multimodal academic discourse of oral presentations, including the verbal, written, non-verbal material (NVM) and body language modes. It offers a Systemic Functional Linguistic (SFL) and multimodal framework of presentations to enhance mixed-disciplinary ELF academics' awareness of what needs to be taken into account to communicate effectively at conferences. The model is also used to establish evaluation criteria for the presenters' talks and to carry out a multimodal discourse analysis of four well-rated 20-min talks, two from the technical sciences and two from the social sciences in a workshop scenario. The findings from the analysis and interviews indicate that: (a) a greater awareness of the mode affordances and their combinations can lead to improved performances; (b) higher reliance on the visual modes can compensate for verbal deficiencies; and (c) effective speakers tend to use a variety of modes that often overlap but work together to convey specific meanings. However, firm conclusions cannot be drawn on the basis of workshop presentations, and further studies on the multimodal analysis of ‘real conferences’ within specific disciplines are encouraged.
Resumo:
Objetivo: Evaluar la eficacia del tratamiento en 3 casos de exotropia intermitente (XT(i)) mediante ejercicios de terapia visual, completando la exploración clínica con Videooculografia-30 y evidenciar la potencial aplicabilidad de esta tecnología para dicho propósito. Métodos: Exponemos los cambios ocurridos tras ejercicios de terapia visual en una mujer de 36 años con XT(i) de -25 dioptrías prismáticas (dp) de lejos y 18 dp de cerca; Un niño de 10 años de edad con 8 dp de XT(i) en posición primaria, asociados a +6 dp de hipotropia izquierda; y un hombre de 63 años con XT(i) de 6 dp en posición primaria asociada a +7 dp de hipertropia derecha. Todos los pacientes presentaron buena agudeza visual corregida en ambos ojos. La inestabilidad de la desviación ocular se evidenció mediante análisis de VOG-30, revelando la presencia de components verticales y torsionales. Se realizaron ejercicios de terapia visual, incluyendo diferentes tipos de ejercicios de vergencias, acomodación y percepción de la diplopía. Resultados: Tras la terapia visual se obtuvieron excelentes rangos de vergencias fusionales y de punto próximo de convergencia («hasta la nariz»). El examen mediante VOG-3D (Sensoro Motoric lnstruments, Teltow, Germany) confirmó la compensación de la desviación con estabilidad del alineamiento ocular. Se observó una significativa mejora después de la terapia en los components verticals y torsionales, lo cuales se hicieron más estables. Los pacientes se mostraron muy satisfechos de los resultados obtenidos. Conclusión: La VOG-3D es una técnica útil para dotamos de un método objetivo de registro de la compensación y estabilidad de la desviación ocular después de realizar ejercicios de terapia visual en casos de XT(i), ofreciéndonos un detallado análisis de la mejoría de los components verticales y torsionales.
Resumo:
Our purpose is to report alterations in contrast sensitivity function (CSF) and in the magno, parvo and koniocellular visual pathways by means of a multichannel perimeter in case of an essential tremor (ET). A complete evaluation of the visual function was performed in a 69-year old patient, including the analysis of the chromatic discrimination by the Fansworth–Munsell 100 hue test, the measurement of the CSF by the CSV-1000E test, and the detection of potential alteration patterns in the magno, parvo and koniocellular visual pathways by means of a multichannel perimeter. Visual acuity and intraocular pressure (IOP) were within the ranges of normality in both eyes. No abnormalities were detected in the fundoscopic examination and in the optical coherence tomography (OCT) exam. The results of the color vision examination were also within the ranges of normality. A significant decrease in the achromatic CSFs for right eye (RE) and left eye (LE) was detected for all spatial frequencies. The statistical global values provided by the multichannel perimeter confirms that there were significant absolute sensitivity losses compared to the normal pattern in RE. In the LE, only a statistically significant decrease in sensitivity was detected for the blue-yellow (BY) channel. The pattern standard deviation (PSD) values obtained in our patient indicated that there were significant localized losses compared to the normality pattern in the achromatic channel of the RE and in the red-green (RG) channel of the LE. Some color vision alterations may be present in ET that cannot be detected with conventional color vision tests, such as the FM 100 Hue.