9 resultados para non destructive testing
em Universidad de Alicante
Resumo:
This paper shows the results of an experimental analysis on the bell tower of “Chiesa della Maddalena” (Mola di Bari, Italy), to better understand the structural behavior of slender masonry structures. The research aims to calibrate a numerical model by means of the Operational Modal Analysis (OMA) method. In this way realistic conclusions about the dynamic behavior of the structure are obtained. The choice of using an OMA derives from the necessity to know the modal parameters of a structure with a non-destructive testing, especially in case of cultural-historical value structures. Therefore by means of an easy and accurate process, it is possible to acquire in-situ environmental vibrations. The data collected are very important to estimate the mode shapes, the natural frequencies and the damping ratios of the structure. To analyze the data obtained from the monitoring, the Peak Picking method has been applied to the Fast Fourier Transforms (FFT) of the signals in order to identify the values of the effective natural frequencies and damping factors of the structure. The main frequencies and the damping ratios have been determined from measurements at some relevant locations. The responses have been then extrapolated and extended to the entire tower through a 3-D Finite Element Model. In this way, knowing the modes of vibration, it has been possible to understand the overall dynamic behavior of the structure.
Resumo:
La principal aportación del trabajo es la formulación de una alternativa que facilita la determinación experimental del factor de pérdidas y, en consecuencia, mejorar las predicciones de aislamiento a ruido aéreo para vidrios con una o más capas intermedias sea cual fuere su naturaleza. Además, se realiza una revisión de las normativas relacionadas con los ensayos de los parámetros mecánicos necesarios para la caracterizar los vidrios, centrándonos en los monolíticos y los laminados. En efecto, uno de los problemas que se plantea en el contexto de la acústica de la edificación actualmente es el de cumplir con los requisitos de aislamiento acústico a ruido aéreo en fachada que exige el vigente Código Técnico de la Edificación (CTE). Como sabemos, en la fachada podemos distinguir la parte ciega y la parte hueca. La parte más débil en lo concerniente a aislamiento a ruido aéreo es la hueca (compuesta por el vidrio, carpintería y otros elementos). Si la carpintería es la adecuada, la superficie de vidrio se convierte en el elemento limitante. El Catálogo de Elementos Constructivos (CEC) del CTE, la propia norma UNE-EN 12758:2011, así como algunos, cada vez más, fabricantes ofrecen datos del aislamiento de vidrios simples, vidrios laminados y vidrios dobles. En el caso de vidrios laminados, estos datos se limitan únicamente en los que tienen un sola lámina intermedia y, además, no acústicos. Podemos hablar, por tanto, de una laguna de información en este sentido. Para obtener predicciones fiables de aislamiento acústico a ruido aéreo de particiones multicapa, como pueden ser los vidrios laminados es necesario disponer de las características mecánicas y una de las más relevantes es el factor de pérdidas.
Resumo:
Commercial off-the-shelf microprocessors are the core of low-cost embedded systems due to their programmability and cost-effectiveness. Recent advances in electronic technologies have allowed remarkable improvements in their performance. However, they have also made microprocessors more susceptible to transient faults induced by radiation. These non-destructive events (soft errors), may cause a microprocessor to produce a wrong computation result or lose control of a system with catastrophic consequences. Therefore, soft error mitigation has become a compulsory requirement for an increasing number of applications, which operate from the space to the ground level. In this context, this paper uses the concept of selective hardening, which is aimed to design reduced-overhead and flexible mitigation techniques. Following this concept, a novel flexible version of the software-based fault recovery technique known as SWIFT-R is proposed. Our approach makes possible to select different registers subsets from the microprocessor register file to be protected on software. Thus, design space is enriched with a wide spectrum of new partially protected versions, which offer more flexibility to designers. This permits to find the best trade-offs between performance, code size, and fault coverage. Three case studies have been developed to show the applicability and flexibility of the proposal.
Resumo:
The paper presents the analysis of an important historical building: the Saint James Theater in the city of Corfù (Greece) actually used as the Municipality House. The building, located in the center of the city, is made of carves stones and is characterized by a stocky shape and by the presence of wooden floors. The study deals with the structural identification of such structure through the analysis of its ambient vibrations recorded by means of accelerometers with high accuracy. A full dynamic testing was developed using ambient vibrations to identify the main modal parameters and to make a non-destructive characterization of this building. The results of these dynamic tests are compared with the modal analysis of a complex finite element (FE) simulation of the structure. This analysis may present several problems and uncertainties for this stocky building. Due to the presence of wooden floors, the local modes can be highly excited and, as a consequence, the evaluation of the structural modal parameters presents some difficulties.
Resumo:
The San Julián’s stone is the main material used to build the most important historical buildings in Alicante city (Spain). This paper describes the analysis developed to obtain the relationship between the static and the dynamic modulus of this sedimentary rock heated at different temperatures. The rock specimens have been subjected to heating processes at different temperatures to produce different levels of weathering on 24 specimens. The static and dynamic modulus has been measured for every specimen by means of the ISRM standard and ultrasonic tests, respectively. Finally, two analytic formulas are proposed for the relationship between the static and the dynamic modulus for this stone. The results have been compared with some relationships proposed by different researchers for other types of rock. The expressions presented in this paper can be useful for the analysis, using non-destructive techniques, of the integrity level of historical constructions built with San Julián’s stone affected by fires.
Resumo:
This work discusses the results from tests which were performed in order to study the effect of high temperatures in the physical and mechanical properties of a calcarenite (San Julian's stone). Samples, previously heated at different temperatures (from 105 °C to 600 °C), were tested. Non-destructive tests (porosity and ultrasonic wave propagation) and destructive tests (uniaxial compressive strength and slake durability test) were performed over available samples. Furthermore, the tests were carried out under different conditions (i.e. air-cooled and water-cooled) in order to study the effect of the fire off method. The results show that uniaxial compressive strength and elastic parameters (i.e. elastic modulus and Poisson's ratio), decrease as the temperature increases for the tested range of temperatures. A reduction of the uniaxial compressive strength up to 35% and 50% is observed in air-cooled and water-cooled samples respectively when the samples are heated to 600 °C. Regarding the Young's modulus, a fall over 75% and 78% in air-cooled and water-cooled samples respectively is observed. Poisson's ratio also declines up to 44% and 68% with the temperature in air-cooled and water-cooled samples respectively. Slake durability index also exhibits a reduction with temperature. Other physical properties, closely related with the mechanical properties of the stone, are porosity, attenuation and propagation velocity of ultrasonic waves in the material. All exhibit considerable changes with temperature.
Resumo:
The moisture content and its spatial distribution has a great influence on the durability properties of concrete structures. Several non-destructive techniques have been used for the determination of the total water content, but moisture distribution is difficult to determine. In this paper impedance spectroscopy is used to study the water distribution in concrete samples with controlled and homogeneously distributed moisture contents. The technique is suitable for the determination of water distribution inside the sample, using the appropriate equivalent circuits. It is shown that using the selected drying procedures there is no change in the solid phase of the samples, although the technique can only be used for the qualitative study of variations in the solid phase when samples are too thick. The results of this work show that for a wide range of concrete percentages of saturation, from full to 18 % saturation, practically all the pores keep at least a thin layer of electrolyte covering their walls, since the capacitance measurement results are practically independent of the saturation degree.
Resumo:
El uso específico de la termografía infrarroja como técnica no destructiva permite el estudio de sistemas constructivos en edificios históricos (caracterización de materiales, disposición constructiva o identificación de elementos originales). Así, se muestra una aplicación práctica en templos en la provincia de Alicante construidos entre finales del siglo XVII y principios del xix, donde se analiza la complementariedad de las imágenes termográficas de 140 cúpulas (junto con datos recopilados in situ, dibujos originales y levantamiento de planos) como herramienta de estudio en fases de análisis previas a una restauración. En conclusión, la investigación detalla una aplicación termográfica al estudio de distintos aspectos como el reconocimiento de materiales empleados (90,71 % ladrillo macizo, 6,43 % ladrillo hueco y 2,86 % piedra), variaciones de espesor interior y exterior (75,71 % perfil apuntado, 17,86 % perfil semiesférico y 6,43 % perfil rebajado), caracterización de grietas/fisuras (estado de conservación) e identificación de cúpulas originales (96,43 %) o restauradas (3,57 %).
Resumo:
Integrity assurance of configuration data has a significant impact on microcontroller-based systems reliability. This is especially true when running applications driven by events which behavior is tightly coupled to this kind of data. This work proposes a new hybrid technique that combines hardware and software resources for detecting and recovering soft-errors in system configuration data. Our approach is based on the utilization of a common built-in microcontroller resource (timer) that works jointly with a software-based technique, which is responsible to periodically refresh the configuration data. The experiments demonstrate that non-destructive single event effects can be effectively mitigated with reduced overheads. Results show an important increase in fault coverage for SEUs and SETs, about one order of magnitude.