8 resultados para Validation of test results

em Universidad de Alicante


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction. To date, no rating scales for detecting apathy in Parkinson’s disease (PD) patients have been validated in Spanish. For this reason, the aim of this study was to validate a Spanish version of Lille apathy rating scale (LARS) in a cohort of PD patients from Spain. Participants and Methods. 130 PD patients and 70 healthy controls were recruited to participate in the study. Apathy was measured using the Spanish version of LARS and the neuropsychiatric inventory (NPI). Reliability (internal consistency, test-retest, and interrater reliability) and validity (construct, content, and criterion validity) were measured. Results. Interrater reliability was 0.93. Cronbach’s α for LARS was 0.81. The test-retest correlation coefficient was 0.97. The correlation between LARS and NPI scores was 0.61. The optimal cutoff point under the ROC curve was , whereas the value derived from healthy controls was . The prevalence of apathy in our population tested by LARS was 42%. Conclusions. The Spanish version of LARS is a reliable and useful tool for diagnosing apathy in PD patients. Total LARS score is influenced by the presence of depression and cognitive impairment. However, both disorders are independent identities with respect to apathy. The satisfactory reliability and validity of the scale make it an appropriate instrument for screening and diagnosing apathy in clinical practice or for research purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The “Mackey Childbirth Satisfaction Rating Scale” (MCSRS) is a complete non-validated scale which includes the most important factors associated with maternal satisfaction. Our primary purpose was to describe the internal structure of the scale and validate the reliability and validity of concept of its Spanish version MCSRS-E. Methods: The MCSRS was translated into Spanish, back-translated and adapted to the Spanish population. It was then administered following a pilot test with women who met the study participant requirements. The scale structure was obtained by performing an exploratory factorial analysis using a sample of 304 women. The structures obtained were tested by conducting a confirmatory factorial analysis using a sample of 159 women. To test the validity of concept, the structure factors were correlated with expectations prior to childbirth experiences. McDonald’s omegas were calculated for each model to establish the reliability of each factor. The study was carried out at four University Hospitals; Alicante, Elche, Torrevieja and Vinalopo Salud of Elche. The inclusion criteria were women aged 18–45 years old who had just delivered a singleton live baby at 38–42 weeks through vaginal delivery. Women who had difficulty speaking and understanding Spanish were excluded. Results: The process generated 5 different possible internal structures in a nested model more consistent with the theory than other internal structures of the MCSRS applied hitherto. All of them had good levels of validation and reliability. Conclusions: This nested model to explain internal structure of MCSRS-E can accommodate different clinical practice scenarios better than the other structures applied to date, and it is a flexible tool which can be used to identify the aspects that should be changed to improve maternal satisfaction and hence maternal health.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: To develop and validate an item bank to measure mobility in older people in primary care and to analyse differential item functioning (DIF) and differential bundle functioning (DBF) by sex. Methods: A pool of 48 mobility items was administered by interview to 593 older people attending primary health care practices. The pool contained four domains based on the International Classification of Functioning: changing and maintaining body position, carrying, lifting and pushing, walking and going up and down stairs. Results: The Late Life Mobility item bank consisted of 35 items, and measured with a reliability of 0.90 or more across the full spectrum of mobility, except at the higher end of better functioning. No evidence was found of non-uniform DIF but uniform DIF was observed, mainly for items in the changing and maintaining body position and carrying, lifting and pushing domains. The walking domain did not display DBF, but the other three domains did, principally the carrying, lifting and pushing items. Conclusions: During the design and validation of an item bank to measure mobility in older people, we found that strength (carrying, lifting and pushing) items formed a secondary dimension that produced DBF. More research is needed to determine how best to include strength items in a mobility measure, or whether it would be more appropriate to design separate measures for each construct.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To validate clinically a new method for estimating the corneal power (P,) using a variable keratometric index (nkadj) in eyes with previous laser refractive surgery. Setting. University of Alicante and Medimar International Hospital (Oftalmar), Alicante, (Spain). Design. Retrospective case series. Methods. This retrospective study comprised 62 eyes of 62 patients that had undergone myopic LASIK surgery. An algorithm for the calculation of 11kadj was used for the estimation of the adjusted keratometric corneal power (Pkadj). This value was compared with the classical keratometric corneal power (Pk), the True Net Power (TNP), and the Gaussian corneal power (PcGauss). Likewise, Pkadj was compared with other previously described methods. Results. Differences between PcGauss and P, values obtained with all methods evaluated were statistically significant (p < 0.01). Differences between Pkadj and PcGauss were in the limit of clinical significance (p < 0.01, loA [ - 0.33,0.60] D). Differences between Pkadj and TNP were not statistically and clinically significant (p = 0.319, loA [- 0.50,0.44] D). Differences between Pkadj and previously described methods were statistically significant (p < 0.01), except with PcHaigisL (p = 0.09, loA [ - 0.37,0.29] D). Conclusion. The use of the adjusted keratometric index (nkadj) is a valid method to estimate the central corneal power in corneas with previous myopic laser refractive surgery, providing results comparable to PcHaigisL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Iterative Closest Point algorithm (ICP) is commonly used in engineering applications to solve the rigid registration problem of partially overlapped point sets which are pre-aligned with a coarse estimate of their relative positions. This iterative algorithm is applied in many areas such as the medicine for volumetric reconstruction of tomography data, in robotics to reconstruct surfaces or scenes using range sensor information, in industrial systems for quality control of manufactured objects or even in biology to study the structure and folding of proteins. One of the algorithm’s main problems is its high computational complexity (quadratic in the number of points with the non-optimized original variant) in a context where high density point sets, acquired by high resolution scanners, are processed. Many variants have been proposed in the literature whose goal is the performance improvement either by reducing the number of points or the required iterations or even enhancing the complexity of the most expensive phase: the closest neighbor search. In spite of decreasing its complexity, some of the variants tend to have a negative impact on the final registration precision or the convergence domain thus limiting the possible application scenarios. The goal of this work is the improvement of the algorithm’s computational cost so that a wider range of computationally demanding problems from among the ones described before can be addressed. For that purpose, an experimental and mathematical convergence analysis and validation of point-to-point distance metrics has been performed taking into account those distances with lower computational cost than the Euclidean one, which is used as the de facto standard for the algorithm’s implementations in the literature. In that analysis, the functioning of the algorithm in diverse topological spaces, characterized by different metrics, has been studied to check the convergence, efficacy and cost of the method in order to determine the one which offers the best results. Given that the distance calculation represents a significant part of the whole set of computations performed by the algorithm, it is expected that any reduction of that operation affects significantly and positively the overall performance of the method. As a result, a performance improvement has been achieved by the application of those reduced cost metrics whose quality in terms of convergence and error has been analyzed and validated experimentally as comparable with respect to the Euclidean distance using a heterogeneous set of objects, scenarios and initial situations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to examine the validity of the Spanish version of the Distance Education Learning Environments Survey (Sp-DELES). This instrument assesses students’ perceptions of virtual learning environments using six scales: Instructor Support, Student Interaction and Collaboration, Personal Relevance, Authentic Learning, Active Learning, and Autonomy. Further, the Sp-DELES includes an additional scale that assesses students’ Satisfaction with their classes. The original DELES has been used in at least 27 independent studies with strong reliability and validity. For this study, we sampled 265 students from the University of Alicante enrolled in various hybrid and distance education courses taught by the Department of Health Psychology. We analysed the Sp-DELES for validity using principal component factor analysis with varimax rotation, and for reliability using Cronbach’s alpha. The Sp-DELES exhibited good reliability (Cronbach’s alpha for the scales ranging from 0.86 to 0.97) and the original six-factor structure was replicated and accounted for 72.9 % of the total variance. Overall the results are consistent with those of the original English-language version of the instrument. The Sp-DELES has proven to be a reliable and valid instrument for assessing psychosocial learning environments in tertiary-level hybrid and distance-education settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study of digital competence remains an issue of interest for both the scientific community and the supranational political agenda. This study uses the Delphi method to validate the design of a questionnaire to determine the perceived importance of digital competence in higher education. The questionnaire was constructed from different framework documents in digital competence standards (NETS, ACLR, UNESCO). The triangulation of non-parametric techniques made it possible to consolidate the results obtained through the Delphi panel, the suitability of which was highlighted through the expert competence index (K). The resulting questionnaire emerges as a good tool for undertaking future national and international studies on digital competence in higher education.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are many models in the literature that have been proposed in the last decades aimed at assessing the reliability, availability and maintainability (RAM) of safety equipment, many of them with a focus on their use to assess the risk level of a technological system or to search for appropriate design and/or surveillance and maintenance policies in order to assure that an optimum level of RAM of safety systems is kept during all the plant operational life. This paper proposes a new approach for RAM modelling that accounts for equipment ageing and maintenance and testing effectiveness of equipment consisting of multiple items in an integrated manner. This model is then used to perform the simultaneous optimization of testing and maintenance for ageing equipment consisting of multiple items. An example of application is provided, which considers a simplified High Pressure Injection System (HPIS) of a typical Power Water Reactor (PWR). Basically, this system consists of motor driven pumps (MDP) and motor operated valves (MOV), where both types of components consists of two items each. These components present different failure and cause modes and behaviours, and they also undertake complex test and maintenance activities depending on the item involved. The results of the example of application demonstrate that the optimization algorithm provide the best solutions when the optimization problem is formulated and solved considering full flexibility in the implementation of testing and maintenance activities taking part of such an integrated RAM model.