7 resultados para System components

em Universidad de Alicante


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to determine if legislation on violence against women (VAW) worldwide contains key components recommended by the Pan American Health Organization (PAHO) and the United Nations (UN) to help strengthen VAW prevention and provide better integrated victim protection, support, and care. A systematic search for VAW legislation using international legal databases and other electronic sources plus data from previous research identified 124 countries/territories with some type of VAW legislation. Full legal texts were found for legislation from 104 countries/territories. Those available in English, Portuguese, and Spanish were downloaded and compiled and the selection criteria applied (use of any of the common terms related to VAW, including intimate partner violence (IPV), and reference to at least two of six sectors (education, health, judicial system, mass media, police, and social services) with regard to VAW interventions (protection, support, and care). A final sample from 80 countries/territories was selected and analyzed for the presence of key components recommended by PAHO and the UN (reference to the term "violence against women" in the title; definitions of different types of VAW; identification of women as beneficiaries; and promotion of (reference to) the participation of multiple sectors in VAW interventions). Few countries/territories specifically identified women as the beneficiaries of their VAW legislation, including those that labeled their legislation "domestic violence" law ( n = 51), of which only two explicitly mentioned women as complainants/survivors. Only 28 countries/territories defined the main forms of VAW (economic, physical, psychological, and sexual) in their VAW legislation. Most highlighted the role of the judicial system, followed by that of social services and the police. Only 28 mentioned the health sector. Despite considerable efforts worldwide to strengthen VAW legislation, most VAW laws do not incorporate the key recommended components. Significant limitations were found in the legislative content, its application, and the extent to which it provided women with integrated protection, support, and care. In developing new VAW legislation, policymakers should consider the vital role of health services.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Semiotic components in the relations of complex systems depend on the Subject. There are two main semiotic components: Neutrosophic and Modal. Modal components are alethical and deontical. In this paper the authors applied the theory of Neutrosophy and Modal Logic to Deontical Impure Systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature and of other anterior segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography and Placido-disk technology. Setting: Vissum Corporation, Alicante, Spain. Design: Evaluation of technology. Methods: All keratoconus eyes had a comprehensive ophthalmologic examination including analysis with the Sirius system. Three consecutive measurements were obtained to assess the intrasubject repeatability of the following parameters: anterior and posterior corneal curvature and shape factor, white-to-white (WTW) corneal diameter, central and minimum corneal thickness, and anterior chamber depth (ACD). The within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC) were calculated. Results: This study comprised 61 eyes of 61 patients ranging in age from 14 to 64 years. For anterior and posterior corneal curvatures and power vector components, the Sw was 0.29 mm or less in all cases. The ICC was above 0.990 in all cases except the flattest curvature of the posterior corneal surface at 3.0 mm, which was 0.840 (moderate agreement), and the posterior power vector J0, which was 0.665 (poor agreement), 0.752, and 0.758 (moderate agreement) for 3.0 mm, 5.0 mm, and 7.0 mm, respectively. In shape factor measurements, the Sw was 0.12 or less in all cases and the ICC ranged between 0.989 and 0.999. Pachymetry, ACD, and WTW had ICC values very close to 1. Conclusion: The new topography system provided repeatable measurements of corneal shape and other anatomic parameters in eyes with keratoconus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose – This paper aims to refer to a subjective approach to a type of complex system: human ecosystems, referred to as deontical impure systems (DIS) to capture a set of properties fundamental to the distinction between human and natural ecosystems. There are four main phenomenological components: directionality, intensity, connection energy and volume. The paper establishes thermodynamics of deontical systems based on the Law of Zipf and the temperature of information. Design/methodology/approach – Mathematical and logical development of human society structure. Findings – A fundamental question in this approach to DIS is the intensity or forces of a relation. Concepts are introduced as the system volume and propose a system thermodynamic theory. It hints at the possibility of adapting the fractal theory by introducing the fractal dimension of the system. Originality/value – This paper is a continuation of other previous papers and developing the theory of DIS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We provide a complete characterization of the astrophysical properties of the σ Ori Aa, Ab, B hierarchical triple system and an improved set of orbital parameters for the highly eccentric σ Ori Aa, Ab spectroscopic binary. We compiled a spectroscopic data set comprising 90 high-resolution spectra covering a total time span of 1963 days. We applied the Lehman-Filhés method for a detailed orbital analysis of the radial velocity curves and performed a combined quantitative spectroscopic analysis of the σ Ori Aa, Ab, B system by means of the stellar atmosphere code FASTWIND. We used our own plus other available information on photometry and distance to the system for measuring the radii, luminosities, and spectroscopic masses of the three components. We also inferred evolutionary masses and stellar ages using the Bayesian code BONNSAI. The orbital analysis of the new radial velocity curves led to a very accurate orbital solution of the σ Ori Aa, Ab pair. We provided indirect arguments indicating that σ Ori B is a fast-rotating early B dwarf. The FASTWIND+BONNSAI analysis showed that the Aa, Ab pair contains the hottest and most massive components of the triple system while σ Ori B is a bit cooler and less massive. The derived stellar ages of the inner pair are intriguingly younger than the one widely accepted for the σ Orionis cluster, at 3 ± 1 Ma. The outcome of this study will be of key importance for a precise determination of the distance to the σ Orionis cluster, the interpretation of the strong X-ray emission detected for σ Ori Aa, Ab, B, and the investigation of the formation and evolution of multiple massive stellar systems and substellar objects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human tremor can be defined as a somewhat rhythmic and quick movement of one or more body parts. In some people, it is a symptom of a neurological disorder. From the mathematical point of view, human tremor can be defined as a weighted contribution of different sinusoidal signals which causes oscillations of some parts of the body. This sinusoidal is repeated over time, but its amplitude and frequency change slowly. This is why amplitude and frequency are considered important factors in the tremor characterization, and thus for its diagnosis. In this paper, a tool for the prediagnosis of the human tremor is presented. This tool uses a low cost device (<$40) and allows to compute the main factors of the human tremor accurately. Real cases have been tested using the algorithms developed in this investigation. The patients suffered from different tremor severities, and the components of amplitude and frequency were computed using a series of tests. These additional measures will help the experts to make better diagnoses allowing them to focus on specific stages of the test or get an overview of these tests. From the experimental, we stated that not all tests are valid for every patient to give a diagnosis. Guided by years of experience, the expert will decide which test or set of tests are the most appropriate for a patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are many models in the literature that have been proposed in the last decades aimed at assessing the reliability, availability and maintainability (RAM) of safety equipment, many of them with a focus on their use to assess the risk level of a technological system or to search for appropriate design and/or surveillance and maintenance policies in order to assure that an optimum level of RAM of safety systems is kept during all the plant operational life. This paper proposes a new approach for RAM modelling that accounts for equipment ageing and maintenance and testing effectiveness of equipment consisting of multiple items in an integrated manner. This model is then used to perform the simultaneous optimization of testing and maintenance for ageing equipment consisting of multiple items. An example of application is provided, which considers a simplified High Pressure Injection System (HPIS) of a typical Power Water Reactor (PWR). Basically, this system consists of motor driven pumps (MDP) and motor operated valves (MOV), where both types of components consists of two items each. These components present different failure and cause modes and behaviours, and they also undertake complex test and maintenance activities depending on the item involved. The results of the example of application demonstrate that the optimization algorithm provide the best solutions when the optimization problem is formulated and solved considering full flexibility in the implementation of testing and maintenance activities taking part of such an integrated RAM model.