7 resultados para Multifocal electroretinogram

em Universidad de Alicante


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background To evaluate the intraocular lens (IOL) position by analyzing the postoperative axis of internal astigmatism as well as the higher-order aberration (HOA) profile after cataract surgery following the implantation of a diffractive multifocal toric IOL. Methods Prospective study including 51 eyes with corneal astigmatism of 1.25D or higher of 29 patients with ages ranging between 20 and 61 years old. All cases underwent uneventful cataract surgery with implantation of the AT LISA 909 M toric IOL (Zeiss). Visual, refractive and corneal topograpy changes were evaluated during a 12-month follow-up. In addition, the axis of internal astigmatism as well as ocular, corneal, and internal HOA (5-mm pupil) were evaluated postoperatively by means of an integrated aberrometer (OPD Scan II, Nidek). Results A significant improvement in uncorrected distance and near visual acuities (p < 0.01) was found, which was consistent with a significant correction of manifest astigmatism (p < 0.01). No significant changes were observed in corneal astigmatism (p = 0.32). With regard to IOL alignment, the difference between the axes of postoperative internal and preoperative corneal astigmatisms was close to perpendicularity (12 months, 87.16° ± 7.14), without significant changes during the first 6 months (p ≥ 0.46). Small but significant changes were detected afterwards (p = 0.01). Additionally, this angular difference correlated with the postoperative magnitude of manifest cylinder (r = 0.31, p = 0.03). Minimal contribution of intraocular optics to the global magnitude of HOA was observed. Conclusions The diffractive multifocal toric IOL evaluated is able to provide a predictable astigmatic correction with apparent excellent levels of optical quality during the first year after implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim was to evaluate the visual performance achieved with a new multifocal hybrid contact lens and to compare it with that obtained with two other currently available multifocal soft contact lenses. Methods: This pilot prospective comparative study comprised a total of 16 presbyopic eyes of eight patients ranging in age from 43 to 58 years. All patients were fitted with three different models of multifocal contact lens: Duette multifocal (SynergEyes), Air Optix AQUA multifocal (Alcon) and Biofinity multifocal (CooperVision). Fittings were performed randomly in each patient according to a random number sequence, with a wash-out period between fittings of seven days. At two weeks post-fitting, visual, photopic contrast sensitivity and ocular aberrometry were evaluated. Results: No statistically significant differences were found in distance and near visual acuity achieved with the three different types of multifocal contact lens (p ≥ 0.05). Likewise, no significant differences between lenses were found in the monocular and binocular defocus curve (p ≥ 0.10). Concerning contrast sensitivity, better monocular contrast sensitivities for 6, 12 and 18 cycles per degree were found with the Duette and Air Optix multifocal compared to Biofinity (p = 0.02). Binocularly, differences between lenses were not significant (p ≥ 0.27). Furthermore, trefoil aberration was significantly higher with Biofinity multifocal (p < 0.01) and Air Optix (p = 0.01) multifocal compared to Duette. Conclusions: The Duette multifocal hybrid contact lens seems to provide similar visual quality outcomes in presbyopic patients with low corneal astigmatism, when compared with other soft multifocal contact lenses. This preliminary result should be confirmed in studies with larger samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Retinal ganglion cell death underlies the pathophysiology of neurodegenerative disorders such as glaucoma or optic nerve trauma. To assess the potential influence of photoreceptor degeneration on retinal ganglion cell survival, and to evaluate functionality, we took advantage of the optic nerve section mouse model. Methods: Surviving retinal ganglion cells were double-stained by exposing both superior colliculi to fluorogold, and by applying dextran-tetramethylrhodamine to the injured optic nerve stump. To assess retinal function in wild-type animals, electroretinograms were recorded on the injured eyes and compared with the contralateral. Similar labelling experiments were carried out on retinal degeneration 1 mice. Surviving retinal ganglion cells were counted 21 days after axotomy and compared with wild-type mice. No functional experiments were performed on retinal degeneration 1 animals because they do not develop normal electroretinographical responses. Results: A significant decrease in retinal ganglion cell density was observed 6 days after axotomy in the wild type. Functional studies revealed that, in scotopic conditions, axotomy induced a significant amplitude decrease in the positive scotopic threshold response component of the electroretinogram. Such decrease paralleled cell loss, suggesting it may be an appropriate technique to evaluate functionality. When comparing retinal ganglion cell densities in wild-type and retinal degeneration 1 mice, a significant greater survival was observed on the latter. Conclusions: After optic nerve section, electroretinographical recordings exhibited a progressive decrease in the amplitude of the positive scotopic threshold response wave, reflecting ganglion cell loss. Interestingly, rod degeneration seemed, at least initially, to protect from axotomy-driven damage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Presbyopia is an age-related physiological condition that causes a gradual loss in the ability to focus on near objects, secondary to changes in zonular fibers, ciliary muscle and crystalline lens. Different surgical approaches are being pursued to surgically compensate presbyopia, such as corneal techniques or implantation of multifocal intraocular lenses (IOLs); however, their inability to restore accommodation has led to the development of single-optic positional accommodative IOLs. The axial shift, with the contraction of the ciliary muscle, of these IOLs increases the refractive power of the eye, improving the level of uncorrected near vision. Single-optic positional accommodative IOLs present few disturbances and larger ocular aberrations that improve near vision. However, reduced amplitudes of accommodation are obtained, little IOL shifts are measured and overall visual outcomes are limited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo del presente estudio ha sido evaluar y analizar resultados tanto clínicos como teóricos para proporcionar un mayor entendimiento del funcionamiento de las lentes intraoculares (LIOs) trifocales. Para ello, se ha realizado una búsqueda bibliográfica, incluyendo tanto artículos de simulaciones en banco óptico como aquellos que muestran resultados clínicos. En la búsqueda se han encontrado artículos sobre tres LIOs trifocales: AT.LISA tri839MP (Carl Zeiss Meditec), FineVision (PhysIOL) y MIOL-Record (Repper-NN). En los estudios teóricos se ha demostrado que las LIOs trifocales presentan una mejora con respecto a las LIOs bifocales en cuanto a visión intermedia pero con una disminución en cuanto a calidad óptica en distancias lejanas y cercanas. Por el contrario, en cuanto a resultados clínicos, las LIOs trifocales proporcionan buenas agudezas visuales en visión lejana y agudezas visuales variables pero siempre aceptables en visión intermedia y cercana. En conclusión, LIOs trifocales ofrecen una opción a aquellos pacientes que necesitan trabajar en visión intermedia y buscan no tener que depender del uso de gafas tras cirugía de catarata.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The P23H rhodopsin mutation is an autosomal dominant cause of retinitis pigmentosa (RP). The degeneration can be tracked using different anatomical and functional methods. In our case, we evaluated the anatomical changes using Spectral-Domain Optical Coherence Tomography (SD-OCT) and correlated the findings with retinal thickness values determined by immunocytochemistry.Methods: Pigmented rats heterozygous for the P23H mutation, with ages between P18 and P180 were studied. Function was assessed by means of optomotor testing and ERGs. Retinal thicknesses measurements, autofluorescence and fluorescein angiography were performed using Spectralis OCT. Retinas were studied by means of immunohistochemistry. Results: Between P30 and P180, visual acuity decreased from 0.500 to 0.182 cycles per degree (cyc/deg) and contrast sensitivity decreased from 54.56 to 2.98 for a spatial frequency of 0.089 cyc/deg. Only cone-driven b-wave responses reached developmental maturity. Flicker fusions were also comparable at P29 (42 Hz). Double flash-isolated rod-driven responses were already affected at P29. Photopic responses revealed deterioration after P29.A reduction in retinal thicknesses and morphological modifications were seen in OCT sections. Statistically significant differences were found in all evaluated thicknesses. Autofluorescence was seen in P23H rats as sparse dots. Immunocytochemistry showed a progressive decrease in the outer nuclear layer (ONL), and morphological changes. Although anatomical thickness measures were significantly lower than OCT values, there was a very strong correlation between the values measured by both techniques.Conclusions: In pigmented P23H rats, a progressive deterioration occurs in both retinal function and anatomy. Anatomical changes can be effectively evaluated using SD-OCT and immunocytochemistry, with a good correlation between their values, thus making SD-OCT an important tool for research in retinal degeneration.